0% found this document useful (0 votes)
192 views8 pages

HR A10v

The document summarizes an axial piston pump model HR-A10VO. It lists key features such as flange connections, leakage ports, permissible speed, suction characteristics, noise level, power/weight ratio and service life. It also describes options for size, control devices, series, direction of rotation, seals, shaft ends, mounting flanges, ports, through drive, multiple pumps and notes on fluid selection.

Uploaded by

Michail Armitage
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
192 views8 pages

HR A10v

The document summarizes an axial piston pump model HR-A10VO. It lists key features such as flange connections, leakage ports, permissible speed, suction characteristics, noise level, power/weight ratio and service life. It also describes options for size, control devices, series, direction of rotation, seals, shaft ends, mounting flanges, ports, through drive, multiple pumps and notes on fluid selection.

Uploaded by

Michail Armitage
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

Axial piston pump

HR-A10VO

Features
– Flange connections to SAE-UNC or SAE
metri
– 2 leakage port
– High permissible speed
– Good suction characteristic
– Low noise leve
– High power/weight rati
– Long service lif
– Short control time
– Axial and radial loading of drive shaft possibl
– Wide range of control
– Through drive option for multi-circuit syste
RE 92701/11.95

Ordering code

Fluid
Mineral oil (no short code)
Axial piston unit
Swashplate design, variable A10V ➛
Nominal pressure 280 bar, peak pressure 350 bar ➛
Operational mode ➛
Pump, open loop circuit O

Size

Displacement Vg max (cm3) 28 45 71* 100 140

Control devices 28 45 71 100 140
2-pos. adjustment, direct control DG DG Page 20
Pressure control DR DR Page 22
DR G DRG Page 24
Remote control
Movable pressure control DRT 1 DRT1 Page 26
for when required DRT 2 DRT2 Page 26
i = 18,2 i = 12,4
Pressure and flow control DFR DFR Page 28
DFR 1 DFR1 Page 28
X port closed
Pressure, flow and power control DFLR DFLR Page 30
Pressure, flow and summ. power control DFSR DFSR Page 32
Flow control, pilot pressure-dependent FHD FHD Page 34
with pressure control
Electronic flow control FE1 FE1 Page 36
Electronic pressure and flow control DFE1 DFE1 Page 36

Series
31
Direction of rotation
Viewed on drive shaft clockwise R
anti-clockwise L

= prefered program (with short delivery times)


(type list see page 44)

* With size 71 please note the following when designing: = available


Pressure port B consists of a multiple high pressure port = in preparation
SAE 11/4" standard pressure range, 3000 psi, for pressures of up to 250 bar – = not available
SAE 1" standard pressure range, 5000 psi, for pressures > 250 bar (see page 14).
For new applications high pressure port SAE 1" must be used.

2 Brueninghaus Hydromatik
A10V O / 31 –

➛ Axial piston pump


➛ Operational mode
➛ Size
➛ Adjustment and control devices
➛ Series
➛ Direction of rotation
Seals
NBR (Nitrile rubber to DIN ISO 1629) P
FPM (Fluoro rubber to DIN ISO 1629) V
Shaft end 28 45 71 100 140
Splined shaft SAE 7/8" 1" 1 1/4" 1 1/2" 1 3/4" S
Splined shaft SAE (higher through drive torque) 7/8" 1" 1 1/4" – – R
Splined shaft SAE (not suitable for through drive) – 7/8" – 1 1/4" – U
Mounting flange 28 45 71 100 140
SAE 2-hole – C
SAE 4-hole – – – – D

Port for service lines 28 45 71 100 140


Pressure port B SAE at rear, fixing thread UNC 61
Suction port S
}
}
Pressure port B SAE on opposite sides, 62
Suction port S fixing thread UNC Port pos. 61
and 11 only
Pressure port B
} SAE at rear, metric fixing thread 11 for version
Suction port S without
Pressure port B } SAE on opposite sides, 12 through drive
Suction port S metric fixing thread

Through drive
Without through drive N00
With through drive (port pos. 62, 12) for mounting AKM or ZRP
Mounting flange Shaft/coupling For mounting:
82-2(SAE A) 16-4(SAE A) G2, GC2/GC3-1X K01
82-2(SAE A) 19-4(SAE A-B) A10VSO 18 (shaft S) K52
101-2(SAE B) 22-4(SAE B) A10VO 28 (shaft S), G3 K02
101-2(SAE B) 22-4(SAE B) G4 K68
101-2(SAE B) 25-4(SAE B-B) A10VO 45 (shaft S), GC4-1X – K04
101-2(SAE B) 32-4(SAE C) GC5-1X – K06
127-2(SAE C) 32-4(SAE C) A10VO 71 (shaft S) – – K07
127-2(SAE C) 38-4(SAE C-C) A10VO 100 (shaft S), GC6-1X – – – K24
152-4(SAE D) 44-4(SAE D) A10VO 140 (shaft S) – – – – K17

Multiple pumps
1. If a second Brueninghaus Hydromatik pump is to be factory-mounted, then both ordering codes are to be
specified, combined with a "+" . Ordering code 1st pump + Ordering code 2nd pump
Ordering example: A10VO 100DR/31R-PSC62K07 + A10VO 71DR/31R-PSC62N00
2. If a gear pump is to be factory-mounted please contact us (RE 90139 in preparation)

Brueninghaus Hydromatik 3
Fluid

Prior to project design, please see our data sheets RE 90220 Notes on the selection of fluid
(mineral oil) and RE 90221 (ecologically acceptable fluids) for For correct selection of the fluid it is assumed that the operating
detailed information on fluids and application conditions. temperature in the tank is known (open loop circuits), in relation
When using ecologically acceptable fluids attention must be to the ambient temperature.
paid to possible limitations of the technical data. If necessary The fluid should be selected so that, within the operating
please contact us. temperature range, the operating viscosity lies within the
optimum range (νopt), (see shaded section of selection diagram).
Operating viscosity range We recommend that the higher viscosity grade is selected in
For optimum efficiency and service life we recommend that the each case.
operating viscosity (at operating temperature) be selected in the Example: At an ambient temperature of X° C the operating
range temperature in the tank will be 60° C. In the optimum operating
viscosity range (νopt; shaded section) this corresponds to
ν opt = opt. operating viscosity 16...36 mm2/s
viscosity grade VG 46 or VG 68; VG 68 should be selected.
referred to tank temperature (open loop circuit). Important: The leakage oil temperature is influenced by
pressure and speed and is always higher than the tank
Limits of viscosity range temperature. At no point in the system, however, may the
The following values are valid for extreme operating conditions: temperature be higher than 90° C.
νmin = 10 mm2/s If it is not possible to comply with the above conditions because
for short periods at max. leakage oil temperature of extreme operating parameters or a high ambient temperature,
of 90° C. please consult us.
νmax = 1000 mm2/s
for short periods upon cold start. Filtration
In order to ensure reliable operation of the axial piston unit, the
Temperature range (see selection diagram) operating fluid must be maintained to a cleanliness class of at
tmin = –25° C least 9 to NAS 1638
tmax = +90° C 6 to SAE
18/15 to ISO/DIS 4406.
This may be achieved, for example, with filter elements
type...D 020...(see RE 31278).
Selection diagram This gives the following degree of separation:

- 20° 0° 20° 40° 60° 80° 100° β20 ≥ 100


1000 1000
600
400
VG

VG

VG

200
VG
VG 8
22

32

46

6
10
0

100
80
60
ty υ (mm / s)
2

40
36
υ opt
Viskosität

20
Viscosi

15 16

10 10
- 25° - 10° 10° 30° 50° 70° 90° Temperature
Temperatur
t (° C)
Fluid temperature range
t min = - 25° C Druckflüssigkeitstemperaturbereich t max = + 90° C

4 Brueninghaus Hydromatik
RE 92701/11.95

Technical data
Inlet operating pressure range
Absolute pressure at port S (A) Determination of inlet pressure pabs at suction port S, or
pabs min ........................................................................... 0,8 bar reduction in flow for increasing speed.
pabs max ........................................................................... 30 bar
1,2
Outlet operating pressure range 1,6
Pressure at port B

Inlet pressure pabs [bar]


Nominal pressure pN .................................................. 280 bar 1,4

Speed n/ nmax
Peak pressure pmax ..................................................... 350 bar 1,1
(Pressure data to DIN 24312) 1,2
Applications with intermittent operating pressures of up to 315
bar at 10% duty cycle are permitted.
1,0 1,0

Case drain pressure 0,9


Maximum pressure of leakage fluid (at ports L, L 1):maximum 0,5
bar higher than input pressure at port S, but not exceeding 2 bar 0,9 0,8
absolute. 0,7 0,8 0,9 1,0
Displacement Vg /Vgmax
Direction of flow
S to B

Tabulated data (theoretical values, without considering ηmh and ηv; approximate values)
Size 28 45 71 100 140
Displacement Vg max cm3 28 45 71 100 140
Max. speed1) at Vg max no max rpm 3000 2600 2200 2000 1800
Max. flow at no max Qo max L/min 84 117 156 200 252
at nE = 1500 rpm L/min 42 68 107 150 210
Max. power (∆p = 280 bar) at no max Po max kW 39 55 73 93 118
at nE = 1500 rpm kW 20 32 50 70 98
Max. torque (∆p = 280 bar) at Vg max Tmax Nm 125 200 316 445 623
Torque (∆p = 100 bar) bei Vg max T Nm 45 72 113 159 223
Moment of inertia at drive axis J kgm2 0,0017 0,0033 0,0083 0,0167 0,0242
Filling capacity L 0,7 1,0 1,6 2,2 3,0
Weight (without fluid) m kg 15 21 33 45 60
Permissible loading of drive shaft:
Max. axial force Fax max N 1000 1500 2400 4000 4800
2
Max. radial force ) Fq max N 1200 1500 1900 2300 2800

1
) Values shown are valid for an absolute pressure of 1 bar at Forces Fq
suction port S.
If the flow is reduced or if the inlet pressure is increased the
speed may be increased according to the diagram. ± Fax
2
) Please consult us for higher radial forces.
X/2 X/2

X
Determination of size
Vg • n • ηv
Flow Q= [L/min]
1000 Vg = geometric displacement [cm3] per rev.
1,59 • Vg • ∆ p ∆p = differential pressure [bar]
Drive torque T= [Nm] n = speed [rpm]
100 • ηmh ηv = volumetric efficiency
ηmh = mechanical-hydraulic efficiency
2π • T • n T•n Q•∆p
Drive power P= = = [kW] ηt = total efficiency (ηt = ηv • ηmh )
60000 9549 600 • ηt

Brueninghaus Hydromatik 5
RE 92701/11.95

Unit dimensions, size 28


Service ports on side, no through drive;
Model 62 N00

View W View V

deep deep

Service ports at rear, no through drive;


Model 11 N00
View Z
deep

Ports
deep
L Case drain port M18x1,5

Service ports on side, no through drive;


Model 12 N00

View W View V

deep deep

Ports
L Case drain port M18x1,5

Brueninghaus Hydromatik 11
DR Pressure control
The pressure control serves to maintain a constant pressure in
the hydraulic system, within the control range of the pump. The
pump therefore supplies only the amount of hydraulic fluid
required by the actuators. Pressure may be smoothly set at the
pilot valve.

Static characteristic
(at n1 = 1500 rpm; toil = 50° C)
Hysteresis and pressure increase ∆p
Flow Q

Setting range

20 280
Operating pressure p [bar]
Dynamic characteristics Ports
The curves show average measured values under test B Pressure port
conditions, with the unit within the tank. S Suction port
Conditions: n = 1500 rpm L, L1 Case drain ports (L1 sealed)
toil = 50° C
Pressure cut-off at 350 bar
Stepped loading by suddenly opening or closing the pressure
line using a pressure relief valve set at 1m downstream from the
axial piston unit.
350

300
Operating pressure p [bar]

250 Control data


Hysteresis and repetitive accuracy ∆p ................... max. 3 bar
200 Max. pressure increase
Size 28 45 71 100 140
150 ∆p bar 4 6 8 10 12
Pilot oil consumption ............................. max. approx. 3 L/min
100
Flow loss at Qmax see pages 8 and 9.
50

0
Vgmax
(Swivel angle)
Displacement

tSA (ms) tSA (ms) tSE (ms)


Size
against 50 bar against 220 bar zero stroke 280 bar
28 60 30 20
V gmin 45 80 40 20
71 100 50 25
Control time t 100 125 90 30
140 130 110 30
Settling time tSA Settling time tSE

22 Brueninghaus Hydromatik
Unit dimensions DR
Service ports at rear; Models 61N00 and 11N00
Sizes 28 to 100 View Z

Mounting of pilot valve Mounting of pilot valve for


for clockwise direction of anti-clockwise direction of
rotation rotation

Size 140 View Z

Unit dimensions DR
Service ports on sides; Models 62 and 12
Sizes 28 to 100 Mounting of pilot valve Mounting of pilot valve for
for anti-clockwise clockwise direction of rotation
direction of rotation

Size 140

Size A1 A2 A3 A4
28 109 225 136 106
45 106 244 146 106
For sizes 28 to 100 the DFR valve
71 106 278 160 106
is used, whereby the flow control
100 106 344 165 106 is sealed in the factory and not
140 127 339 169 127 tested.

Brueninghaus Hydromatik 23

You might also like