Introduction
The purpose of this guide is to help users to link Aspen Dynamic with Matlab Simulink;
“Aspen Plus Dynamics is Aspentech easy-to-use dynamic modeling tool for plant
operations and process design. It enables users to study and understand the dynamics
of real plant operations, thereby achieving increased operability, safety and
productivity.”
Thus by combining both software, users able to develop/simulate complex chemical processes inside
Aspen Plus Dynamics and further analyzed them in terms of sensitivity, control, optimization, safety and
operability using Matlab Simulink.
Compatibility issue
Please note that MATLAB uses 64-bit in releases starting with R2016 and Aspen Plus Dynamics only uses
64-bit starting with V11. As a result, Aspen Plus Dynamics prior to V11 will not work with MATLAB R2016
and above. Thus, for Aspen Plus Dynamics V10 and earlier, the latest version that can work is MATLAB
R2015b.
Step by step guide
This tutorial procedure is created based on the author experience (I am using Aspen Plus V11 and Matlab
R2017b). Thus, there are maybe better ways to performed it.
Figure 1
4. After copying the file, double click the block. A menu for Aspen Modeler Input file will popup and
browse for the targeted Aspen Dynamic file (refer Figure 2). Select the Aspen Dynamic model file
and click open. Here, I am using the Aspen Dynamics model from my research work [1].
[1] Muhammad, D., Z. Ahmad, and N. Aziz, Low density polyethylene tubular reactor control using state space model predictive
control. Chemical Engineering Communications, 2019: p. 1-17.
Figure 2
5. This action should opened up the Aspen Dynamics model and AMSimulation block menu (refer
Figure 3). In the author’s experience, untick the “Only show Input/Output variables on the browse
lists”. This will make all the available variables in the Aspen Dynamics model will appeared in the
list.
Figure 3
6. Click the Variable column in the configure menu and select the desired variables (from a list of
variables) as the Model Input. Click Add button to add another input. Switch to the next tab to
select the variables as the Model Output. The Port column represents the number of
Input/Output that have been selected. Click OK button after finished selecting the model inputs
and outputs. *for control study, Input represents the manipulated variable (MV) or controller
output (CO), while Output represent the control variable (CV) or process variable (CV).
7. By right the number of AMSimulation block input/output port will equivalent to the number of
inputs/outputs that had been selected in the configuration menu. In this example, I am simulating
a single input and single output process. A step change is introduced to the process and the output
result is observed from the Scope block. After finished arrange the related block, click Run button
in the Simulink to start the simulation.
Figure 4
8. By right, both of the software will run simultaneously as shown in Figure 5. Based on the figure,
the Step change input is entering the AMSimulation block (represent the Aspen Dynamics model),
which has resulted the output temperature to drop. This conclude the tutorial.
Figure 5
Additional notes
1. Based on my experience, I would recommend to run these programs (as administrator);
am_task_server.exe and sim_server.exe inside the Aspen Plus installation folder (C:\Program
Files\AspenTech\AMSystem V11.0\Bin) before the linking process.
2. If there are some problems during the linking, running the AMFixUtility.exe inside the same folder.
It probably can help. If not, try to reopen the both software and or restart the computer.