Lumicor Point Support Guide
Lumicor Point Support Guide
Lumicor Point Support Guide
Create a timeless impact on any environment with this versatile hardware solution. Stand
Offs bring refinement and style to numerous applications, both vertical and horizontal.
Use standoffs for affixing Lumicor materials to a variety of substrates, including wood,
metal or concrete.
Lumicor offers a variety of Stand Off components, including barrels, caps, and anchors,
which work in unison to create a solid solution for flexibility and ease of installation.
Please refer to this Guide for the number of Stand Offs recommended for a specific
panel size, the hardware required for various substrates, and other important
information or simply call customer care.
01/2013
STAND OFFS
How to Order
WIDTH
Standard Lumicor panels are 4’x8’
and can be cut to desired size.
HEIGHT
2 CHOOSE PANEL GAUGE | Thinner gauges require more Stand Offs to prevent
2
bowing. Please consult the Stand Off Placement Guide on the following pages.
gauge
4 (A) CAP DIAMETER, & (B) BARREL LENGTH | These choices are mostly
4
aesthetic. How prominent do you want the cap to be? How much space
cap & barrel diameter
do you want between the cap and the wall?
Note: Circle is the standard cap shape. Custom cap shapes are available
(low-profile, square, etc.), contact your sales rep. All stand offs are satin silver.
barrel length
A Cap and barrel diameter B Barrel length
*
3/4” 1”
18mm 24mm 1/4” 1/2” 3/4” 1”
6mm 12mm 18mm 24mm
*3/4" diameter is only suitable
for up to .236" gauge
01/2013
STAND OFFS
Overview Page
Use Stand Offs in vertical or horizontal applications. View the examples below for ideas.
All orders are customized to fit your project specifications.
APPLICATION: VERTICAL
Add color, protection, and interest to walls
with Lumicor panels. Panels can be spaced or
overlapped by using different length Stand Offs.
PAGE 3
PAGE 4
PAGE 5
The above illustrations are to be used as guidelines only, as your individual installation may be different from these examples. They also illustrate
general guidelines on mounting options for Lumicor panels based on the weight of the panel itself. For installations requiring load considerations
additional engineering may be required. No safety guarantee is expressed or implied. Recycled glass requires special considerations.
01/2013
STAND OFFS
Quantity & Placement: Vertical
size of sheet
1"
(24mm)
thickness
3/4"
(18mm)
STAND OFF QTY 4 4 4 4 4 6 6 6
1/2”
(12mm)
STAND OFF QTY 4 4 4 6 6 6 6 8
PLEASE NOTE
3/8”
(9mm)
STAND OFF QTY 4 4 6 6 8 8 8 10
1/4”
(6mm)
STAND OFF QTY 4 6 9 9 9 10 12 12
3/16"
(5mm) LIGHT LOAD APPLICATIONS
STAND OFF QTY 4 9 9 12 12 10 15 18
( )
The Stand Off configurations
Lumicor does not recommend these in this guide were created to
support the weight of the panel
options due to the quantity of Stand Offs only. If you plan to use Stand
5/32"
(4mm) required to support the panel. Offs for light load applications,
as shown above, we recommend
STAND OFF QTY 4 9 9 12 12 10 15 18
using extra Stand Offs for
support. Please call us for
more information or refer
1/8" to our Deflection Matrix
(3mm) at www.lumicor.com.
STAND OFF QTY 6 7 12 15 16 14 20 24
The above illustrations are to be used as guidelines only, as your individual installation may be different from these examples. They also illustrate
general guidelines on mounting options for Lumicor panels based on the weight of the panel itself. For installations requiring load considerations
additional engineering may be required. No safety guarantee is expressed or implied. Recycled glass requires special considerations.
01/2013
STAND OFFS
Quantity & Placement: Horizontal
size of sheet
1"
(24mm)
thickness
3/4"
(18mm)
STAND OFF QTY 4 6 8 8 8 12
1/2"
(12mm)
STAND OFF QTY 4 6 12 8 12 12
3/8"
(9mm)
STAND OFF QTY 4 6 12 10 15 15
1/4"
(6mm)
STAND OFF QTY 6 8 15 14 18 28
3/16"
(5mm)
STAND OFF QTY 9 12 15 18 18 28
(
STAND OFF QTY
Lumicor does not recommend these
5/32" options due to the quantity of Stand Offs
(4mm)
required to support the panel.
9 12 20 21 21
) 28
1/8"
(3mm)
STAND OFF QTY 9 12 24 21 28 35
The above illustrations are to be used as guidelines only, as your individual installation may be different from these examples. They also illustrate
general guidelines on mounting options for Lumicor panels based on the weight of the panel itself. For installations requiring load considerations
additional engineering may be required. No safety guarantee is expressed or implied. Recycled glass requires special considerations.
01/2013
STAND OFFS
Quantity & Placement: Work Surfaces
size of sheet
PLEASE NOTE
1"
(24mm)
thickness
3/4"
(18mm)
STAND OFF QTY 4 6 8 8 12 12
1/2"
(12mm)
LIGHT LOAD APPLICATIONS
STAND OFF QTY 5 8 12 11 15 15
The Stand Off configurations in this
guide were created to support the
weight of the panel with a 50 lb point
3/8" load applied at the weakest location
(9mm)
of the panel to maintain a deflection
STAND OFF QTY 4 6 12 10 15 15
under 3/16". If you plan to use stand
offs for any heavy load applications, such
as a transaction top, as shown above,
we recommend using extra Stand Offs
1/4"
(6mm) for support. Please call us for more
information or refer to our Deflection
STAND OFF QTY 6 8 15 14 18 28
Matrix at www.lumicor.com.
3/16"
( )
(5mm)
STAND OFF QTY Lumicor
9 does
12 not recommend
15 18 these 18 28
1/8"
(3mm)
STAND OFF QTY 9 12 24 21 28 35
The above illustrations are to be used as guidelines only, as your individual installation may be different from these examples. They also illustrate
general guidelines on mounting options for Lumicor panels based on the weight of the panel itself. For installations requiring load considerations
additional engineering may be required. No safety guarantee is expressed or implied. Recycled glass requires special considerations.
01/2013
STAND OFFS
Anchor Conditions
CONCRETE
Concrete anchors are used for securing Stand Offs directly into
CONCRETE ANCHOR
concrete. A threaded rod is inserted into the anchor. A Stand
Off barrel is then attached to the rod for a secure mount.
STAND OFF
BARREL
THREADED SCREW
(TOP VIEW)
WOOD
For mounting Stand Offs to wood (or drywall over a wall
DRYWALL
stud) screw a threaded rod directly into the wood. A Stand
Off barrel is then attached to the rod for a secure mount.
THREADED SCREW
(TOP VIEW)
TOGGLE BOLT
(TOP VIEW)
The above illustrations are to be used as guidelines only, as your individual installation may be different from these examples. They also illustrate
general guidelines on mounting options for Lumicor panels based on the weight of the panel itself. For installations requiring load considerations
additional engineering may be required. No safety guarantee is expressed or implied. Recycled glass requires special considerations.
01/2013