Pre Assessment COMMON
Pre Assessment COMMON
Pre Assessment COMMON
Region V
DIVISION OF NAGA CITY
CAMARINES SUR NATIONAL HIGH SCHOOL
Penafrancia Avenue, Naga City
1. This refers to a wiring accessory that is used to hold the conduit firmly.
2. This refers to the box which is used as termination point and for joining different run of raceway or cable.
3. It is used to protect and route electrical wiring in a building or structure.
4. An electric safety device that automatically trips off and breaks the flow or current when there’s an overload or short
circuit.
5. An electrical device that disconnects or connects the conducting path in an electrical circuit, interrupting the electric
current or diverting it from one conductor to another
6. It is a component of an electrical distribution system which divides an electrical power feed into branch circuits,
while providing a protective circuit breaker or fuse for each circuit, in a common enclosure
7. It is used to drive and loose cross – slotted – head screw.
8. It is used to scrape surfaces of conductors and to remove big cables’ insulation.
9. It is a pipe bending tool with handles of several sizes and lengths.
10. It is commonly used to make terminal loops on copper wire and can each tight places.
11. It is used to drive and to pull out nails.
12. Used for cutting medium or fine wires and bending small pieces of soft metal.
13. Used for cutting big cables and twisting, holding wires together.
14. Used for skinning insulated electrical conductors.
15. A tool intended to cut PVC conduit only.
16. Used for both guiding and testing the work to a vertical or horizontal position.
17. Used to layout distances. It can measure in two measuring systems. English and Metric.
18. What is the total voltage if you have 20watts and 6Ω?
a. 120V b. 3.33V c. 1.82V d. 10.95V
19. What is the resistance if you have 8 amperes and 600 watts?
a. 9.37Ω b. 4,800 Ω c. 75 Ω d. 69.28Ω
20. What is the power if you have 25 amperes and 10Ω?
a. 250 watts b. 15.81 watts c. 6,250 watts d. 2.5 watts
21. What is the total current if you have 1,000 watts and 30Ω?
a. 30,000A b 5.77A c. 173.2A d. 6.77A
22. A load has a resistance of 8Ω with a voltage of 250V. If the current of the load is 31.25 amperes, what is the power of the
load?
a. 7,812.5 watts b. 7,812.5 V c. 7,912.5 watts d. 7,812.0 watts
23. A load with a 50V supply consumes 150 watts of power. How many amperes does this load consume?
a. 450A b. 3A c. 1.70A d. 3.1A
24. The minimum size of conductor for lighting circuit according to the Philippine Electrical Code.
a. 2.0mm2 b. 3.5mm2 c. 5.5mm2 d. 2.5mm2
25. The ampacity of the connected load shall not exceed how many percent of the ampacity of the wire and over current
protective device (OCPD)?
a.125% b. 250% c. 80% d. 75%
26. What is the total load of 6 lighting outlet in a 230V source?
a. 1080 watts b. 600A c. 2.60A d. 469 watts
27. What is the ampacity rating of a TW 3.5mm2 conductor?
a. 20 A b. 20 watts c. 15 A d. 25 A
28. S2 is the symbol for _______
a. Single pole switch b. Single pole double throw switch c. Two gang switch d. Two way switch
29. What is the allowable maximum load for each household lighting outlet according toPhilippine Electrical Code (PEC)?
30. The minimum size of conductor for lighting circuit according to the Philippine Electrical Code (PEC).
31. What is the mounting height of a convenience outlet?
32. In sizing the branch circuit conductor supplying an Air conditioning unit or motor, the wire shall be rated________
a. At least 250% of FLA motor rating c. At least 125% of FLA motor rating
b. At least 80% of FLA motor rating d. At least 135% of the total connected load
33. The ampacity of the connected load shall not exceed how many percent of the ampacity of the wire and overcurrent protective
device (OCPD)?
34. What is the minimum size of conductor used for service entrance?
47. The following are safety tips in handling energized parts using a multitester (VOM) EXCEPT
a. Use an attendant if necessary
b. Isolate the area from all traffic
c. Turn off all power sources
d. Post signs & barricades
48. When measuring unknown AC voltage using a multitester, you should_____
a. Set the selector knob to the highest voltage range.
b. Set the selector knob to 250V to get the AC voltage.
c. Set the zero ohm adjuster to have an exact measurement of the unknown voltage.
d. Set the selector know to AC and get the measurement.
49. In measuring the voltage of a branch circuit, what should be the position of the test probe?
a. In series with the load and the source
b. Across the supply or load
c. The knob must be in the resistance range and the probe is parallel to the source or load
d. In series with the power supply
50. When measuring unknown AC voltage using a multitester, you should_______________________
51-53. Illustrate how you will measure a voltage using a multitester
54-56 Illustrate how you will measure the amperage of a circuit using multitester
57-59When can you say that there is continuity in the circuit? (using multitester)
INTERPRET TECHNICAL DRAWING
PERFORMANCE:
36-40. Draw the schematic diagram of two(2) single pole switch located in different locations each controlling two(2) bulbs.
41-45. Draw the pictorial diagram of a duplex convenience outlet with grounding
- Correct connection of electrical devices and grounding
- Show how OCPDs are connected (fr. Main to its branch circuit)
46-50. Find the total load in amperes of a single family dwelling with 230 Volt service, Single phase – 3 wire 60Hz in line to line service
(Show your solution)
A. Lighting Load:
Ckt 1 – 900 Watts
Ckt 2 – 800 Watts
Ckt 3 – 600 Watts
B. Small Appliances:
Ckt 4 – 1800 Watts
Ckt 5 – 1440 Watts
C. Other Loads:
Ckt 6 – 8KW (Range)
Ckt 7 – 4500 Watts (Water Heater)
Cuts away rough edges or burrs inside pipe after it has been cut with a pipe cutter. It is used with an auger brace.
- Pipe burring Reamer
A pipe bending tool made in various sizes and handle lengths, depending upon the diameter of the pipe to be
bent – Hickey
Another important tool used to cut pipe and has three small round cutters. It is made of hardened steel. The pipe
is slipped over tongue where the cut is to made. The cutters are gradually pressed against the pipe and rotated
until it is severed. – Pipe cutter
Shaft or spindle use to hold a revolving cutting tool or the work cut. – Hole saws and Arbor
62. What is the allowable maximum load for each household lighting outlet according toPhilippine Electrical Code (PEC)?
63. The minimum size of conductor for lighting circuit according to the Philippine Electrical Code (PEC).
64. What is the mounting height of a convenience outlet?
65. In sizing the branch circuit conductor supplying an Air conditioning unit or motor, the wire shall be rated________
c. At least 250% of FLA motor rating c. At least 125% of FLA motor rating
d. At least 80% of FLA motor rating d. At least 135% of the total connected load
66. The ampacity of the connected load shall not exceed how many percent of the ampacity of the wire and overcurrent protective
device (OCPD)?
67. What is the minimum size of conductor used for service entrance?