0% found this document useful (0 votes)
75 views

Flyer Wellhead Data Recorder

Spartek Systems specializes in providing oil and gas companies with data monitoring solutions, including their SS6100 Wellhead Data Recorder. The SS6100 can monitor up to three pressure or temperature sensors independently, store over 4 million samples of data with its lithium battery for over one year, and transfer data via USB interface. It is intrinsically safe, has a wide operating temperature range, and provides reliable monitoring of wells.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
75 views

Flyer Wellhead Data Recorder

Spartek Systems specializes in providing oil and gas companies with data monitoring solutions, including their SS6100 Wellhead Data Recorder. The SS6100 can monitor up to three pressure or temperature sensors independently, store over 4 million samples of data with its lithium battery for over one year, and transfer data via USB interface. It is intrinsically safe, has a wide operating temperature range, and provides reliable monitoring of wells.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

ELECTRONIC MEMORY RECORDERS

Wellhead Data Recorder

Spartek Systems specializes in providing the oil and gas industry with high quality data to monitor well per-
formance and diagnose poten al problems. Founded in 1994, Spartek Systems leads the industry in providing
cost effec ve solu ons for acquiring reliable well informa on.

Product Overview
The SS6100 Wellhead Data Recorders (WHDR) pro-
vide a cost effec ve solu on for monitoring well
pressures and temperature. The system can be con-
figured to measure up to three independent pres-
sure or temperature sensors. Each “smart stem” is
independently calibrated from the main body. Both
Quartz and Sapphire pressure sensors are available.
This allows the user to reconfigure the system as
needed or use back up “smart stems” when calibra-
ons are required.
The system u lizes an intelligent, primary lithium,
non-restricted-for-transport ba ery pack (a lithium-
ion rechargeable pack with accompanying charger
are also available). This power system provides the
user with the necessary feedback to ensure that sufficient power is available for the dura on of the survey.
With memory capable of storing 4 million samples, when fully charged, this low power WHDR has the capability
of acquiring data for over one year.

Primary Features
 Approved for Intrinsically Safe, Ex ia IIB T3 Ga
 Independently Calibrated “Smart Stems”
 Superior data quality / stability
 Wide opera ng temperature range
 Available in a several pressure ranges to op mize
results (750 psi to 15,000 psi)
 Programmable sample rates (1 sample/sec max)
 4 million sample memory capacity
 Intelligent primary lithium ba ery pack
 Low power consump on
 LCD character display (magne c switch ac va-
on)
 Lightweight & compact in size makes for easy
installa on and handling
 High speed data transfer interface (USB 2.0)
 Field maintainable
 Windows OS: 10/8/7/Vista/XP

SPARTEK SYSTEMS
Providing Our Customers With “Best In Class” Technology

Email: [email protected] h p://www.sparteksystems.com


Rev: 08/17/2017

Specifications:
MODEL SS6100
Input channels 1-3 Channels (see Sensor Types) Operating Range -40oC to 70oC (-40oF to 158oF)
Pressure Sensor Temperature Sensor
Sensor type Sapphire (piezo-resistive) Sensor Type Remote fast response RTD
Available ranges 750, 1500, 3k, 6k, 10k or 15k Probe Housing 17-4 PH Stainless
(psi) Probe Sheath 316 Stainless
0.3 psi or 0.03% Full Scale Remote Distance Standard 10m (optional up to
Accuracy1,2 0.0003% Full Scale Range 30m)
Resolution Accuracy 177oC (350oF)
Resolution +/- 0.4oC (0.7oF)
Sensor type Quartz 0.005oC (0.009oF)
Available ranges 5k, 10k or 15k (psi)
Accuracy 0.020% Full Scale
Resolution 0.0002% Full Scale

Stem Housing 17-4 PH Stainless or Inconel-718

Calibration < 3 psi drift per year Data Acquisition


(Recommend re-calibration every 9 Total Sample Capacity 4,000,000 samples
-12 months) Maximum Sample Rate 1 sample/second
Programmable Sample Up to 15 different intervals
Modes
Power Primary Lithium dedicated I.S. Safety Approved for Intrinsically Safe
Battery Ex ia IIB T3 Ga
(Operating -40oC to 70oC) (with IS Battery)

Lithium-Ion Rechargeable
[Non I.S.]
(Operating -20oC to 60oC )

Software OS Windows 10/8/7/Vista/XP Communications Full speed USB 2.0

Notes:
1. Accuracy is larger of the two stated values over the temperature range of -15 oC to 70 oC. This includes the combined
effects of hysteresis, repeatability, and the corrected linearity over the calibrated temperature range. At temperatures
below -15 oC, the actual error may be as high as 0.05% of Full Scale. Typically, the accuracy will be within the stated
specifications.
2. Accuracy can be improved by limiting the range of the calibration (pressure and/or temperature). Consult your Spartek
representative for specifications at other calibrated pressure and temperature ranges.

Specifications subject to change without notice

For More Information, Pricing, and Technical Support Contact:

#1 Thevenaz Industrial Trail


Sylvan Lake, Alberta
Canada,T4S 2J6

Tel: (403) 887-2443


Fax: (403) 887-4050

Providing Our Customers With “Best In Class” Technology

Email: [email protected] h p://www.sparteksystems.com

You might also like