MELSEC-Q Series: Comprehensive, Risk-Free Upgrade Solutions
MELSEC-Q Series: Comprehensive, Risk-Free Upgrade Solutions
Oct.2017 Edition
From MELSEC-A/QnA Series
MELSEC-Q Series
Supporting
1
Mitsubishi Electric offers a carefully engineered combination of
hardware, software, and support designed to allow you to upgrade
legacy MELSEC-AnS/QnAS Series controller systems to the
current MELSEC-L/Q Series with minimum disruption to your plant
operations.
2
Upgrade Option
Replace with the Q Series while reusing the existing programs P.7
A/QnA -> Q Conversion Support Tool → MELSOFT
Replace the main base unit with the Q Series while keeping
the existing extension base unit P.12
QA conversion adapter →
3
Replace Q4ARCPU redundant system with Q Series P.20
Q Series QCPU redundant system Redundant
system
Support P.32
Global FA Centers Support
4
At-a-glance technical overview
Technical Bulletin
Large type A/QnA Series 〈Date of discontinuation〉〈Technical bulletin No.〉
A/QnA (large type) ●CPU module End of Sep. 2006 T99-0050
●I/O module End of Sep. 2006 T99-0050
●Special function module End of Sep. 2006 T99-0050
●Data link module (MELSECNET(Ⅱ), End of Sep. 2006 T99-0050
●MELSECNET/B module, etc.)
●MELSEC-I/OLINK master module End of Sep. 2006 T99-0050
●MELSECNET/MINI-S3 master module End of Sep. 2008 T99-0050
●Network module (MELSECNET/10) End of Sep. 2014 FA-A-0141
A2C Series
A2C ●CPU module End of Sep. 2006 T99-0050
●A2C I/O module End of Sep. 2008 T99-0070
●Special function module etc. End of Sep. 2008 T99-0070
A0J2(H) Series
A0J2(H) ●CPU module End of Sep. 2008 T99-0069
●Power supply module End of Sep. 2008 T99-0069
●I/O module End of Sep. 2008 T99-0069
●Special function module etc. End of Sep. 2008 T99-0069
Please refer to the Technical Bulletin "Repair acceptance of discontinued models (FA-A-0049)" for the repair acceptance
period of the above discontinued products.
5
In-depth technical documentation resource
Transition Handbook
Transition from MELSEC-A/QnA (Large Type) Series to Q Series Handbook
●Fundamentals L(NA)08043ENG
●Intelligent Function Modules L(NA)08046ENG
● For the products shown in handbooks for transition, catalogs, and transition examples, refer to the manuals for
the relevant products and check the detailed specifications, precautions for use, and restrictions before
replacement.
For the products manufactured by Mitsubishi Electric Engineering Co., Ltd., Mitsubishi Electric System & Service
Co., Ltd., and other companies, refer to the catalog for each product and check the detailed specifications,
precautions for use, and restrictions before use.
The manuals and catalogs for our products, products manufactured by Mitsubishi Electric Engineering Co., Ltd.,
and Mitsubishi Electric System & Service Co., Ltd., are shown in Appendix of each handbook for transition.
● Products shown in this handbook are subject to change without notice.
6
*1
A/QnA -> Q Conversion Support Tool
Enter the configuration information on the existing A/QnA special function modules.
Point
1
●By specifying module names, the
X/Y devices and buffer memory
addresses are converted (when
the programs are compatible)
<Differences highlighted>
9
■Details of unconverted special relays and registers can be displayed, improving conversion
efficiency.
[Example] Special relays and registers which are not converted in the Q program
10
For Large Type A/QnA Series
Q Series
Q Series
Step 1 Step 2
Entire replacement
with the Q Series modules
Q Series
extension cable
QA extension base
Existing large type A Series (QA65B/QA68B)
Existing large type A power supply module, ●Remove the QA extension base unit (QA65B/
I/O modules, and other modules can be QA68B) when all modules have been replaced
utilized; wiring is left as it is. with Q Series equivalents.
●The QA6□B extension base units are compatible with the High Performance model QCPUs, and Universal model
QCPUs*1(including High-speed Universal model QCPUs). Basic model QCPUs, process CPUs, redundant CPUs or
remote I/O stations are not compatible.
●Please refer to the "QA65B/QA68B Extension Base Unit User's Manual (IB(NA)-0800158)" for details of modules
that can be installed onto on the QA6□B extension base units.
*1: Universal model QCPU, whose first 5-digit serial number is 13102 or later, is compatible with the base unit.
QY41P
QX41
QX41
0 1 2 3 4
AJ61BT11
AJ71LP21
A3NCPU
AY41
AX41
modules (A to Q) modules
QA6□B or A6□B
(with QA conversion adapter)
5 6 7 8 9
Empty
Empty
AX41
AY41
AX41
■Install a QA conversion adapter to use the existing A/QnA Series extension base units
with a Q Series CPU.
Q Series
main base system
A/QnA Series
main base system
QA6ADP
Notes
●The QA6ADP adapter cannot be connected to a QA1S extension base unit, which is being used to hold small type AnS/Q2AS Series modules.
●The QA6ADP adapter is compatible with High Performance model QCPUs only. Basic model QCPUs, process CPUs, redundant CPUs, safety
CPUs, Universal model QCPUs*1(including High-speed Universal model QCPUs), and remote I/O stations are not compatible.
●Modules which can be installed to the extension base unit (A6□B) are the same as when QA6□B is used.
●An adapter module mounting bracket is required to install the QA6ADP adapter. Follow the instructions in the user's manual for the installation procedure.
●When an AC input module is installed on the "A5□B" extension base unit (without power supply) using the QA6ADP, either the "A6□B with
QA6ADP" or "QA6□B" extension base unit (with power supply) is required in the system.
*1: Universal model QCPU, whose first 5-digit serial number is 13102 or later, is compatible with Adapter.
Note: Assign the I/O numbers in the following order: Q Series to A Series or A Series to Q Series.
When the order is mixed (i.e., Q Series → A Series → Q Series), an error will occur in the CPU.
12
Q Series Large Type Base Unit,
Q68BL
I/O Module ( Q35BL Q65BL ・ QG69L )
QY11AL
Q38BL
・ ・ QX11L
QX21L
・ QY13L
QY23L
Q55BL QY51PL
■Minimize wiring modifications by reusing the existing A Series 32-point I/O wiring.
■No need to make new installation holes. The hole size and pitch of the Q Series large type
base units are the same as those of A/QnA Series.
FUSE
0
L
A 1
2
3
4
5
Detach the
6
7
wired terminal
8
QX40 1
L 9
A 2
3
B
block or
4
C 5
D
QY23L 6
E 7
F
connector
QX11L 8
U 9
Q12HCP
FUSE 0
QY13L 10
MODE 0 L 11
POW
ER
RUN B 1
L
I/O module.
1 3
L 3 5 6 16
A 1
2 4 17
2 4 6 7
1 3 5
3 5 7 18
4 6 19
4 2 6 7 8
3 5
7 8 L 9 20
5 21
4 6 L 8
6 9
5COM 7 9 A
22
7 8 A 10 B 23
PULL 6 8
7 9 9 B 11 C
24
USB 8
8
A 10
C 12 D 25
L 9 9 B 11 D 13
E 26
PULL A C 12 E 14 F 27
10 15
B 11 D 13 F 28
2 C E 14 16 29
RS-23 12
15 17
D 13 F 0 30
L 18 31
E 14 COM B16 17 1 19
F 15 0 2 32
18 20 TRIAC /240V QY23L 33
B16 17 1 19
3 21 AC100
0 2 4 0.6A 34
L 20 22 35
18
B 1
19
3 21 5 23
2 4 6 36
22 24 37
20
3 21 5 23 7 25 38
4 6
22 24 26
5 23 7 25 8 27
L
6 COM 26
9 28
24 29
7 25 8 27 A
9 28 B 30
26 31
8 27 A 29 C
L 9 B D 32
28 30
29 C 31 33
manufactured by Mitsubishi
D 32 F 34
33 35 37
E 38
F 34 M 36
35CO 37
Install directly.
DC24V
power supply 2
1
terminal block
4
5
Q Series
6
I/O module.
12
13
14
15
16
17
18
19
20
21
22
Q Series
23
24
25
26
module
27
28
29
30
31
32
33
36
37
・Q Series power supply and CPU modules can be used without any modification (Q Series large type blank
cover is not necessary).
・Q Series large type I/O modules can be used with Q Series modules. (Some modules, such as the ones that
occupy two slots, cannot be installed. For details, please refer to Q Series Large Type Base Unit User's
Manual (IB-0800408).)
Notes
●Through the use of Upgrade Tool (manufactured by Mitsubishi Electric Engineering Co., Ltd., refer to page 15),
terminal block modules that are not compatible with the Q Series large type I/O modules can be installed
without rewiring.
●For compatibility of Q Series large type base unit and upgrade tool, refer to page 16.
13
■Q Series large type base units
Type Model Outline
32 points; 100 to 120 V AC; rated input current: 10 mA (100 V AC, 60 Hz);
AX11 QX11L response time: 15 ms or less (OFF to ON), 25 ms or less (ON to OFF);
32 points/common; 38-point terminal block
Input module
32 points; 200 to 240 V AC input; rated input current: 10 mA (220 V AC, 60 Hz);
AX21 QX21L response time: 15 ms or less (OFF to ON), 25 ms or less (ON to OFF);
32 points/common; 38-point terminal block
32-point triac output, 100 to 240 V AC, 0.6 A/point, 2.4 A/common,
AY23 QY23L
8 points/common, 38-point terminal block
AY51 32-point transistor output (Sink), 12/24 V DC, 0.5 A/point, 4 A/common,
QY51PL
AY51-S1 16 points/common, 38-point terminal block
Q Series large Blank cover for installing the existing Q Series module on the Q Series large
type blank cover ̶ QG69L
type base unit
Note
●The Q Series large type base units and I/O modules are compatible with High Performance model QCPUs,
Universal model QCPUs*1(including High-speed Universal model QCPUs), and MELSECNET/H remote I/O stations.
The following CPUs and system are not compatible:
・Basic model QCPUs, process CPUs, redundant CPUs, and safety CPUs
・Q00UJCPU
*1: Universal model QCPU, whose first 5-digit serial number is 13102 or later, is compatible
14
A/Q Upgrade Tool/FA Goods
(manufactured by Mitsubishi Electric Engineering Co., Ltd.)
■Upgrade tool
The upgrade tool consists of three components: a conversion adapter, which modifies the existing wiring of the
A/QnA Series input/output/analog/high-speed counter modules to correspond to the Q Series modules; a conversion
adapter support flange, which supports the conversion adapters from the bottom, and a base adapter, which allows
the Q Series base unit to be installed using the installation holes of the A/QnA Series base unit. (The upgrade tool
does not include the Q Series base unit. Please prepare it separately.)
●Remove the large type A/QnA Series programmable controllers along with the base unit, install the base adapter in
the same position, and install Q Series modules. (New installation holes are unnecessary when installing the base
adapter)
●Remove the terminal blocks from the existing large type A/QnA Series modules and attach them to the conversion
adapters. (The existing wiring can be used without modification.)
●FA goods may be used for an I/O module that is not available in the Q Series.
■FA goods
FA goods are useful for system configuration with the Q Series modules. These goods consist of connector/terminal
conversion module, terminal module, and positioning module cable, etc. FA goods can be used when a module
replacement is not available because of the module's specification, etc.
Upgrade tool
(Base adapter)
Upgrade tool
(Support flange for
Conversion adapter)
Upgrade tool
(Conversion adapter)
Y0 to YF
Terminal module
(FA-TH16YRA20)
Same width as the large type Same width as Q Series base unit
Slot width of base unit*3
A Series base unit (37.5 mm) (27.4 mm)
Power supply module Q Series power supply module ○ ○
Basic model QCPU × ○
High Performance model QCPU ○ ○
CPU module
Installable Process CPU × ○
module Universal model QCPU ○*4 ○
○: Applicable (installable) △: Applicable with restrictions (installable) ×: Not Applicable (Not installable)
*1:Q Series large type base units can be used with Q *8:High Performance model QCPUs and Universal model
Series base units. QCPUsNote (include High-speed Universal model QCPUs)
*2:The base adapter manufactured by Mitsubishi Electric can be connected to the QA/QA1S extension base unit.
Engineering Co., Ltd. is to be installed to the Q Series *9:If the size of cable connected to the terminal block is
base unit. larger than 1.25 mm2, ERNT-AQTX41, AQTY41,
*3:Check the installation conditions before using the AQTX81, AQTY81, AQT68AD, AQT68ADN, AQT68DA,
upgrade tool, because wiring space is reduced due to and AQTD61 modules may have a difficulty in installation.
a decrease in the module's width. In this case, secure wiring space by leaving empty slots
in between modules. For example, install modules on slot
A/QnA Series module Q Series module No. 0, 2, 4, 6, 8, and leave slot No. 1, 3, 5, 7 empty. If the
number of slots is insufficient, consider using the Q
Series large type base unit.
0 0
0 1 2 3 4 5 6 7 8
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
A A 0 0 0 0 0
B B 1 1 1 1 1
C C 2 2 2 2 2
D D 3
4
3
4
3
4
3
4
3
4
E E 5 5 5 5 5
F F 6 6 6 6 6
7 7 7 7 7
8 8 8 8 8
9 9 9 9 9
A A A A A
B B B B B
C C C C C
D D D D D
E E E E E
F F F F F
37.5 27.4
*4:Q00UJCPU is not compatible. *10:When using two Q Series modules with the existing
*5:The common terminal arrangement and electrical specifications wiring terminals using conversion adapters.
are same as that of large type A Series I/O module. For example, when replacing an A616AD module with
*6:Since the conversion adapters are to be installed onto the two Q68ADV(I) modules.
Q Series modules, the specifications and functions are
same as that of the Q Series modules. (Please check the
Q68ADV(I)
transition handbook, since the specifications and functions
are different from that of large type A Series module)
*7:Q Series large type blank cover (QG69L) is required.
Some modules are not compatible. (Some exceeds 98
mm height.) For details, please refer to the Q Series
Large Type Blank Cover User's Manual (IB-0800408). Conversion
adapter
Note: Universal model QCPU, whose first 5-digit serial number
Existing A616AD terminal block
is 13102 or later, is compatible with the base units.
16
Module for Easy Replacement
20 Y20
Blank to 32 points
3F Y3F
Same I/O numbers are used for input and output Sequential I/O numbers are used for input and output
Control station Normal station Normal station Normal station Normal station Normal station
Model Outline
A1 A1 Q1
A2 A5 Q2 A5 Q2 Q5
MELSECNET MELSECNET MELSECNET
/10 /10 /H(10)
A3 A4 Q3 A4 Q3 Q4
【Before transition】 【Transitional step】 【Transition completed】
A/QnA
Step-by-step replacement from AnS/QnAS modules to Q Series *1*2 An Series system Qn Q Series system
18
MELSECNET/10 Network Module
(production continued)
■Step-by-step transition from the A/QnA Series and Q Series combined system to the Q Series system.
MELSECNET(Ⅱ) system can be replaced with the MELSECNET/10 system while reusing the existing cable installations.
Following the network replacement, A/QnA Series systems are replaced with Q Series stations as needed in a
step-by-step manner.
Note that in the MELSECNET/H system, the PLC-to-PLC network stations and the remote I/O network stations
cannot be mixed. For the transition, use the normal stations (local stations) only instead of remote I/O stations.
Furthermore, the step-by-step transition is not possible if the network includes a combination of A/QnA Series and
Q Series stations, because A/QnA Series system does not support MELSECNET/H twisted bus network system.
A1 A1 Q1 Q1
A2 A5 A2 A5 A2 A5 Q2 Q5
MELSECNET MELSECNET MELSECNET MELSECNET
(Ⅱ) /10 /10 /H(10)
A3 A4 A3 A4 Q3 A4 Q3 Q4
Qn Q Series system
Model
Type
Control/normal station
*1: The production was discontinued in September 2014. For the details, please refer to Technical Bulletin No.FA-A-0141.
19
Q Series Redundant System
Select the best Q Series redundant system
configuration for the application
■Easily replace the existing Q4ARCPU redundant system to the QCPU redundant system.
A61RP
A4UCPU
Control system Standby system
Redundant CPU Redundant CPU
A4UCPU
A61RP
Extension cable
PLC to PLC
network Redundant power extension base unit
Q25HCPU
POWER QJ71LP21-25
QX42-S1 Q25HCPU
MODE
QX42-S1 POWER Q12HCPU
RUN QY42P QJ71LP21-25
ERR QY42P
MODE
MODE
QX42-S1
USER
RUN QY42P
BAT
ERR RUN
QY42P
USER ERR
BOOT
BAT USER
BOOT BAT
BOOT
PULL
PULL
PULL
PULL
PULL
USB
USB
USB
RS-232
RS-232
RS-232
■Network modules of MELSECNET/H PLC to PLC network and remote I/O network can be installed to the Q Series
redundant CPU main base. (They can be used together.)
A wide variety of system is constructed to suit the needs of the control target.
■Realizes local I/O system equivalent to Q4ARCPU using the redundant type extension base
unit.
■Up to 63 modules can be installed using the redundant type extension base unit.
■Fast system switching time at approx. 50 ms in the redundant local I/O system, remarkable
improvement compared to the Q4ARCPU redundant system (300 ms + 1 scan time).
20
A0J2 Renewal Tool
(manufactured by Mitsubishi Electric System & Service Co., Ltd.)
【After upgrade】
On-board installation
Suitable when there is enough
depth. Stack the programmable
controller on the existing panel
face.
Adjacent installation
Suitable when there is enough
space above existing modules.
Install the programmable
controller above the interface
module(s).
Note: Space of 92 mm or
more from the top of the
existing modules is
required.
For detailed specifications, precautions, and restrictions of the A0J2 renewal tool, please refer to the brochure
(X900904-165) and user's manual. For further information, please contact your local Mitsubishi Electric sales
office or sales representative.
21
■Structure
[Example] 2-level on-board installation
■Basic configuration
【Before upgrade】 【After upgrade】
Q Series programmable controller A0J2 renewal tool*2
A0J2(H) Series programmable controller
・Main base unit(Q33B) ・Interface module
・CPU module +
・Power supply module(Q62P)*1 ・Programmable controller fixing frame set*3
・I/O module
・CPU module ・Programmable controller connection cable
・I/O module
*1: The interface modules except for some models require 24 V DC power supply. If the Q62P is not used, provide a
separate external power supply.
*2: See the following list for the applicable interface module.
*3: Includes a base adapter, mounting plate, mounting frame, terminal block, and power supply cable.
Discontinued model Replacement interface module Discontinued model Replacement interface module
A0J2-E28DR SC-A0JQIF-28DR
1. When upgrading to the Q Series module, programs do not need to be modified if the I/O combined module "QX41Y41P
(32-point input for the first half and 32-point output for the second half)" is used. (Refer to page 17)
2. The A0J2 renewal tool can be used to replace MELSECNET/MINI compact type I/O modules
(AJ35PTF-□ (such as 28AR and 56DR)) with CC-Link modules.
3. For products that are not described (such as connection cables for programmable controller), please contact your local
Mitsubishi sales office or representative
22
A2C Shape CC-Link Remote I/O Module
Replace A2CCPU and NET/MINI-S3 I/O modules with
CC-Link modules using the existing NET/MINI-S3 wiring
After replacing
the module,
attach the wired
terminal block.*1
Alternative model
Discontinued model
Model Outline
AX41C Terminal block type, 24 V DC input, 32 points,
AJ65DBTB1-32D
AX81C positive/negative common shared
AY51C AJ65DBTB1-32T1 Terminal block type, 0.5 A transistor output, 32 points, sink
23
MELSECNET/MINI-S3 I/O Module
Wiring Conversion Adapter
Replace NET/MINI-S3 system with CC-Link network
system while reusing the existing NET/MINI-S3 wiring
Wiring
conversion
adapter
No modification is necessary
for I/O wiring since the
Rewire the CC-Link cables
existing terminal block of the
and power cables only.
MELSECNET/MINI-S3 I/O
module can be used.
Model
Type Model Remarks (restrictions)
Alternative module Conversion adapter
Wiring conversion adapter *1: The overall size is increased
AJ35TB1-16D AJ65BTB1-16D for 26-point terminal block*1 due to addition of the adapter
A6ADP-1MC16D to the alternative module.
Input module
Wiring conversion adapter *2: Additional wiring to CTL+
AJ35TB2-16D AJ65BTB2-16D for 34-point terminal block*1 (External power supply for
A6ADP-2MC16D output) is required.
Wiring conversion adapter
Output module AJ35TB1-16T AJ65BTB1-16T for 26-point terminal block*1, *2
A6ADP-1MC16T
24
For Large Type A/QnA Series
Small type AnS/QnAS Series I/O module, special function module, etc.
■For a system with free I/O points and slots Large type A/QnA Series base unit
A-A1S module
conversion adapter
A module in the existing system needs to be (A1ADP-□)
removed to install a CC-Link system master/local
station when there are no free slots or I/O points.
Small type AnS/QnAS
The functionalities of the removed module can be
Series CC-Link
compensated by adding CC-Link remote modules.
master/local module
(A1SJ61(Q)BT11)
CC-Link remote
I/O module
●Up to three A-A1S module conversion adapters can be used per base unit.
●A-A1S module conversion adapters are compatible with the QA extension base unit and the large type A Series
extension base unit (when QA conversion adapter (QA6ADP) is install).
●For details of applicable CPU modules, installable modules, and supported adapters for each module, refer to
the following manual.
・Product manual: A-A1S Module Conversion Adapter User’ s Manual (IB-0800352-E or later version)
25 ●The production of the AnS/QnAS (small type) Series was discontinued at the end of September 2014 (except
few models including the AnS/QnAS Series CC-Link master/local module).
Product List
QA1S51B 1 slot, for AnS Series modules (power supply module not required)
QA1S65B 5 slots, for AnS Series modules
QA(1S) extension
QA1S68B 8 slots, for AnS Series modules
base unit
QA65B 5 slots, for A Series modules
QA68B 8 slots, for A Series modules
QA conversion adapter
Type Model Outline
QA conversion Adapter for connecting large type A/QnA extension base unit as QCPU
QA6ADP
adapter extension base unit
8 slots, 1 power supply module required, for the Q Series large type I/O
Q38BL
modules
Main base unit
5 slots, 1 power supply module required, for the Q Series large type I/O
Q35BL
modules
8 slots, 1 power supply module required, for the Q Series large type I/O
Q68BL
modules
Extension 5 slots, 1 power supply module required, for the Q Series large type I/O
Q65BL
base unit modules
5 slots, power supply module not required, for the Q Series large type I/O
Q55BL
modules
26
Product List
32 points, 100 to 120 V AC, rated input current: 10 mA (100 V AC, 60 Hz),
QX11L response time: 15 ms or less (OFF to ON), 25 ms or less (ON to OFF),
32 points/common, 38-point terminal block
Input module
32 points, 200 to 240 V AC, rated input current: 10 mA (220 V AC, 60 Hz),
QX21L response time: 15 ms or less (OFF to ON), 25 ms or less (ON to OFF),
32 points/common, 38-point terminal block
16-point contact output, 24 V DC/240 V AC, 2 A/point, 16 A/all points,
QY11AL all points independent, 38-point terminal block,
surge suppressor (varistor 387 to 473 V)
32-point contact output, 24 V DC/240 V AC, 2 A/point, 5 A/common,
QY13L
8 points/common, 38-point terminal block
Output module
32-point triac output, 100 to 240 V AC, 0.6 A/point, 2.4 A/common,
QY23L 8 points/common, 38-point terminal block
32-point transistor output (Sink), 12/24 V DC, 0.5 A/point, 4 A/common,
QY51PL 16 points/common, 38-point terminal block
Q Series large Blank cover for installing the existing Q Series module on the
QG69L
type blank cover Q Series large type base unit
DC input module
Type Model Outline
32 points, 24 V DC, rated input current: approximately 6 mA, positive common type,
32 points/common, response time: 1 ms/5 ms/10 ms/20 ms/70 ms or less
QX41-S2
(Set by the CPU parameter at the initial setting of 10 ms for both ON to OFF
and OFF to ON)
DC input module
32 points, 24 V DC, rated input current: approximately 6 mA, negative common type,
32 points/common, response time: 1 ms/5 ms/10 ms/20 ms/70 ms or less
QX81-S2
(Set by the CPU parameter at the initial setting of 10 ms for both ON to OFF
and OFF to ON)
27
High-speed counter module
Type Model Outline
High-speed counter module for replacing the AD61
QD62-H01 (with the same input filtering system and counting speed)
High-speed
counter module High-speed counter module for replacing the AD61-S1
QD62-H02 (with the same input filtering system and counting speed)
28
Product List
29
Models in continuous production
The production of the A/QnA Series products except the following modules has been discontinued since September 2006.
Note: In accordance with the continuation of production, model names may be changed.
A61PN*
1
Battery
Type Model
Battery A6BAT
Only some models of the MELSEC-A/QnA (Large Type) Series are still in limited production. However, the
EN61131-2:2003 certification has expired, so the CE Declaration for models still in production has been withdrawn.
(Technical Bulletin No. FA-A-0071)
Discontinued products
Date of
Discontinued products
discontinuation
●CPU module ●I/O module ●Special function module
Large type A Series/ ●Data link module (MELSECNET(Ⅱ), MELSECNET/B module, etc.) End of Sep. 2006
Large type QnA Series ●MELSECNET/MINI-S3 master module
●MELSECNET/10 network module ●MELSEC-I/OLINK master module End of Sep. 2014
Network interface
●MELSECNET(Ⅱ), MELSECNET/B interface board End of Sep. 2008
board
Note: The production of the AnS/QnAS Series was also discontinued at the end of September 2014.
30
Product List
Products
Service Service availability period (7 years)
discontinued
availability
at the end of
period*1
Sep. 2008 Production discontinued End of service
(Sep. 2008) (Sep. 2015)
Products
Service Service availability period (7 years)
discontinued
availability
at the end of
period*3
Sep. 2014 Production discontinued End of service
(Sep. 2014) (Sep. 2021)
*1: For details of the service availability period of discontinued products, refer to Technical Bulletin No.FA-A-0049.
*2: Production of selected products , which were discontinued at the end of September 2006
(Technical Bulletin No.T99-0050), were extended until end of September 2008 as spare. However, its continued
production has ended as of the end of September 2008.
*3: For details of the service availability period of discontinued products, refer to Technical Bulletin No. FA-A-0141 and
No. FA-A-0142.
31
Responding to the amenable running of FA systems
through an enhanced support system
Global FA Centers
"Mitsubishi Electric Global FA centers" have been established in various countries around the world to cover the Americas, Europe, and Asia.
FA centers help to ensure compliance with the certifications and regulations of different regions, initiate product development in response to
local demands, and provide full-time, professional customer service.
32
33
Precautions before use
This publication explains the typical features and functions of the products herein and To use the products given in this publication properly, always read the relevant manuals before use.
does not provide restrictions and other information related to usage and module The products have been manufactured as general-purpose parts for general industries, and have not
combinations. Before using the products, always read the product user manuals. been designed or manufactured to be incorporated in a device or system used in purposes related to
human life.
Mitsubishi Electric will not be held liable for damage caused by factors found not to be
Before using the products for special purposes such as nuclear power, electric power, aerospace,
the cause of Mitsubishi Electric; opportunity loss or lost profits caused by faults in
medicine or passenger movement vehicles, consult with Mitsubishi.
Mitsubishi Electric products; damage, secondary damage, or accident compensation, The products have been manufactured under strict quality control. However, when installing the
whether foreseeable or not, caused by special factors; damage to products other than products where major accidents or losses could occur if the products fail, install appropriate backup
Mitsubishi Electric products; and to other duties. or fail-safe functions in the system.
34
Mitsubishi Programmable Controllers
MELSEC-A/QnA Series Transition Guide
Country/Region Sales office Tel/Fax
USA Mitsubishi Electric Automation, lnc. Tel : +1-847-478-2100
500 Corporate Woods Parkway, Vernon Hills, IL 60061, USA Fax : +1-847-478-2253
Mexico Mitsubishi Electric Automation, lnc. Mexico Branch Tel : +52-55-3067-7500
Mariano Escobedo #69, Col. Zona Industrial, Tlalnepantla Edo, C.P.54030, Mexico
Brazil Mitsubishi Electric do Brasil Comércio e Serviços Ltda. Tel : +55-11-4689-3000
Rua Jussara, 1750- Bloco B Anexo, Jardim Santa Cecilia, CEP 06465-070, Barueri, San Paulo, Brazil Fax : +55-11-4689-3016
Germany Mitsubishi Electric Europe B.V. German Branch Tel : +49-2102-486-0
Gothaer Strasse 8, D-40880 Ratingen, Germany Fax : +49-2102-486-1120
UK Mitsubishi Electric Europe B.V. UK Branch Tel : +44-1707-28-8780
Travellers Lane, Hatfield, Hertfordshire, AL10 8XB, U.K. Fax : +44-1707-27-8695
Ireland Mitsubishi Electric Europe B.V. Irish Branch Tel : +353-1-4198800
Westgate Business Park, Ballymount, IRL-Dublin 24, Ireland Fax : +353-1-4198890
Italy Mitsubishi Electric Europe B.V. Italian Branch Tel : +39-039-60531
Centro Direzionale Colleoni - Palazzo Sirio Viale Colleoni 7, 20864 Agrate Brianza(Milano) Italy Fax : +39-039-6053-312
Spain Mitsubishi Electric Europe B.V. Spanish Branch Tel : +34-93-565-3131
Carretera de Rubí, 76-80-Apdo. 420, 08173 Sant Cugat del Vallés (Barcelona), Spain Fax : +34-93-589-1579
France Mitsubishi Electric Europe B.V. French Branch Tel : +33-1-5568-5568
25, Boulevard des Bouvets, F-92741 Nanterre Cedex, France Fax : +33-1-5568-5757
Czech Republic Mitsubishi Electric Europe B.V. Czech Branch Tel : +420-251-551-470
Avenir Business Park, Radlicka 751/113e, 158 00 Praha5, Czech Republic Fax : +420-251-551-471
Poland Mitsubishi Electric Europe B.V. Polish Branch Tel : +48-12-630-47-00
ul. Krakowska 50, 32-083 Balice, Poland Fax : +48-12-630-47-01
Sweden Mitsubishi Electric Europe B.V. (Scandinavia) Tel : +46-8-625-10-00
Fjelievägen 8, SE-22736 Lund, Sweden Fax : +46-46-39-70-18
Russia Mitsubishi Electric Europe B.V. Russian Branch St. Petersburg Office Tel : +7-812-633-3497
Piskarevsky pr. 2, bld 2, lit “Sch”, BC “Benua”, office 720; 195027, St. Petersburg, Russia Fax : +7-812-633-3499
Turkey Mitsubishi Electric Turkey A.Ş Ümraniye Branch Tel : +90-216-526-3990
Serifali Mahallesi Nutuk Sokak No:5, TR-34775 Umraniye, Istanbul, Turkey Fax : +90 -216-526-3995
Dubai Mitsubishi Electric Europe B.V. Dubai Branch Tel : +971-4-3724716
Dubai Silicon Oasis, P.O.BOX 341241, Dubai, U.A.E. Fax : +971-4-3724721
South Africa Adroit Technologies 20 Waterford Office Park 189 Witkoppen Road Fourways Johannesburg Tel : +27-11 658-8100
South Africa Fax : +27-11 658-8101
China Mitsubishi Electric Automation (China) Ltd. Tel : +86-21-2322-3030
No.1386 Hongqiao Road, Mitsubishi Electric Automation Center, Shanghai, China Fax : +86-21-2322-3000
Taiwan Setsuyo Enterprise Co., Ltd. Tel : +886-2-2299-2499
6F., No.105, Wugong 3rd Road, Wugu District, New Taipei City 24889, Taiwan, R.O.C. Fax : +886-2-2299-2509
Korea Mitsubishi Electric Automation Korea Co., Ltd. Tel : +82-2-3660-9530
1480-6, Gayang-Dong, Gangseo-Gu, Seoul, 157-200, Korea Fax : +82-2-3664-8372
Singapore Mitsubishi Electric Asia Pte. Ltd. Tel : +65-6470-2308
307, Alexandra Road, Mitsubishi Electric Building, Singapore, 159943 Fax : +65-6476-7439
Thailand Mitsubishi Electric Factory Automation (Thailand) Co., Ltd. Tel : +66-2682-6522
12th Floor, SV.City Building, Office Tower 1, No. 896/19 and 20 Rama 3 Road, Fax : +66-2682-6020
Kwaeng Bangpongpang, Khet Yannawa, Bangkok 10120, Thailand
Vietnam Mitsubishi Electric Vietnam Company Limited Hanoi Branch Tel : +84-4-3937-8075
Suite 9-05, 9th Floor, Hanoi Central Office Building 44B Ly Thuong Kiet District, Hanoi City, Vietnam Fax : +84-4-3937-8076
Indonesia PT. Mitsubishi Electric Indonesia Tel : +62-21-3192-6461
Gedung Jaya 11th Floor, JL. MH. Thamrin No.12, Jakarta Pusat 10340, Indonesia Fax : +62-21-3192-3942
India Mitsubishi Electric India Pvt. Ltd. Tel : +91-20-2710-2000
Emerald House, EL-3, J Block, M.I.D.C., Bhosari, Pune, 411026, Maharashtra State, India Fax : +91-20-2710-2100
Australia Mitsubishi Electric Australia Pty. Ltd. Tel : +61-2-9684-7777
348 Victoria Road, P.O. Box 11, Rydalmere, N.S.W 2116, Australia Fax : +61-2-9684-7245