0% found this document useful (0 votes)
64 views10 pages

4525 S HSK Ew 010 Series

This document provides notes and specifications for repair works on a roof structure. It includes assumptions about existing rafter dimensions and spacing. It specifies treatments for preservation and fire retardance. Notes indicate additional time and costs may be required to address potential defects found during repair works. Specifications are provided for concrete padstones. Temporary propping of the structure is not shown but will be required during repairs.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
64 views10 pages

4525 S HSK Ew 010 Series

This document provides notes and specifications for repair works on a roof structure. It includes assumptions about existing rafter dimensions and spacing. It specifies treatments for preservation and fire retardance. Notes indicate additional time and costs may be required to address potential defects found during repair works. Specifications are provided for concrete padstones. Temporary propping of the structure is not shown but will be required during repairs.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 10

NOTES

A B 1 DO NOT SCALE FROM THIS DRAWING.


2 ALL DIMENSIONS ARE IN MILLIMETRES (mm) AND ALL LEVEL ARE IN METRES (m)
UNLESS NOTED OTHERWISE.
3 THIS DRAWING IS TO BE PRINTED IN COLOUR.

FOR FULL SECTION SIZES, REFER TO ANNOTATED SKETCHES IN THIS DOCUMENT

PRESERVATIVE TREATMENT: ORGANIC SOLVENT IMPREGNATION TO NBS SECTION Z12


AND WOOD PROTECTION ASSOCIATION COMMODITY SPECIFICATION C8
DESIGN SERVICE LIFE: 60 YEARS.TBC
FIRE RETARDANT TREATMENT: AS PER GENERAL NOTES

ROOF STRUCTURE
RAFTERS ASSUMED AT 0.4m CENTRES, ASSUMED DIMENSION 150x50mm.
RAFTERS ARE SUPPORTED BY THE MASONRY WALL AND A TIMBER WALLPLATE

3 FOR LOADING ALLOWANCES REFER TO 4525 - GENERAL NOTES.

ALL ASSUMED DIMENSIONS TO BE CONFIRMED ON SITE.


REPAIR WORKS TO BE CARRIED OUT ONLY AFTER THE ROT AND INFESTATION SURVEY
(CONDITION SURVEY), IN ORDER TO DEFINE THE EXTENT OF ROT AND TO CONFIRM THE
FEASIBILITY OF THESE REPAIRS.

NOTE THAT THE MASONRY WALLS ARE LIKELY TO REQUIRE TREATMENT TO DRY ROT AND
ASSUMED EXISTING 50 X 150 mm COMMON FINISHES TO BE REMOVED TO PREVENT THE RE-INFECTION OF THE TIMBER ELEMENTS.
RAFTERS TEMPORARY PROPPING TO SUPPORT STRUCTURE WHILST REPAIRS ARE UNDERTAKEN
ARE NOT SHOWN FOR CLARITY.
CONTRACTOR TO ALLOW FOR AN ELEMENT OF ADJUSTING OF TEMPORARY WORKS TO
ALLOW REPAIRS TO BE CARRIED OUT.
ADDITIONAL TIME FRAME IN THE PROGRAMME AND CONTINGENCY IN THE COST PLAN TO
UNIT 603 UNIT 613 RESPOND TO EXPOSED POTENTIAL DEFECTS IN THE EXISTING STRUCTURE AND THE
EXISTING STRUCTURE BEING DIFFERENT THAN ASSUMED AND SHOWN ON THIS DRAWING.

SPECIFICATION FOR CONCRETE PADSTONES

-COMPRESSIVE STRENGTH CLASS (CYLINDER/ CUBE MINIMUM): C25/30


-TARGET DENSITY (OVEN-DRY): NORMAL.
-FIBRES: NOT REQUIRED.
-AGGREGATE SIZE (MAXIMUM): 20MM TYPE/ DENSITY: NORMAL WEIGHT.
-COARSE RECYCLED AGGREGATES: RA NOT PERMITTED, RCA OF LOCAL SUPPLY WITHIN
30KM OF SITE TO BS8500-2-2006 TABLE 2 AND 3, MASS FRACTION NOT EXCEEDING 20% OF
COARSE AGGREGATES PERMISSIBLE.
-ADDITIONAL AGGREGATE REQUIREMENTS: ALL AGGREGATES TO CONFORM TO BS EN
12620.
-DESIGN CHEMICAL CLASS: CLASS DS-1 TO DS-3 AND ACEC AC-1 TO AC-3 OF TABLE C2 OF
4 5 4 BRE SPECIAL DIGEST 1 PART C (2005). ENVIRONMENTAL CLASS: XC1
LIMITING VALUES FOR COMPOSITION:
-WATER:CEMENT RATIO (MAXIMUM): AS DC CLASS.
-CEMENT/ COMBINATION CONTENT (MINIMUM): AS PER ENVIRONMENTAL CLASS.
-CEMENT/ COMBINATION CONTENT (MAXIMUM): AS PER ENVIRONMENTAL CLASS.
-AIR CONTENT IN SITU (MINIMUM): NO REQUIREMENT.
-CONSISTENCE CLASS: CONTRACTOR’S CHOICE.
-PERMITTED CEMENT/ COMBINATIONS: AS PER ENVIRONMENTAL CLASS.
-CHLORIDE CLASS: BIP 2001: GENERALLY CL 0.40.
-COLOUR: NOT REQUIRED.
-ADDITIONAL MIX REQUIREMENTS: WHERE SECONDARY AGGREGATES ARE USED WITH

A B APPROVAL ADDITIONAL AGGREGATE TESTING WILL BE REQUIRED INCLUDING REGULAR


TESTING OF WATER ABSORPTION. FULL REGIME TO BE AGREED SUBJECT TO IDENTIFYING
SUPPLY.

METAL STRAPS,FRAMING ANCHORS, REINFORCED ANGLED BRACKETS AND PROPRIETARY


PLAN VIEW - UNITS 612 TO 614 & 616 TO 617 & 619 TO 621 PRODUCTS

PLAN VIEW - UNITS 602 TO 606 (PLAN TAKEN FROM JHA ANNEXE BUILDING CONTRACT 2 REPORT -MANUFACTURER: SIMPSON, OR SIMILAR APPROVED BY THE STRUCTURAL ENGINEER.
-PRODUCT REFERENCE: REFER TO DETAILS, OR SIMILAR APPROVED BY THE STRUCTURAL
(PLAN TAKEN FROM JHA ANNEXE BUILDING CONTRACT 2 REPORT AND DRAWINGS ENGINEER.
-MATERIAL/ FINISH: MATERIAL/ FINISH: STAINLESS STEEL GRADE 304 TO BS EN 10088-2
AND DRAWINGS -FASTENERS: STAINLESS STEEL
-FIXING: SECURE USING NOT LESS THAN THE NUMBER OF NAILS RECOMMENDED BY
ANCHOR MANUFACTURER.

KEY PLAN: POTENTIAL EXTENT OF ROT NOT VISIBLE BUT MOISTURE CONTENT > THAN 20%
KEY: TIMBER SPECIALIST/CONTRACTOR TO CONFIRM MOISTURE CONTENT IN TIMBER JOISTS AND
EXTENT

REPLACEMENT AND IMPLEMENTATION OF THE GUTTER STRUCTURE REQUIRED. CONNECTION

RAFTER REPAIR/REPLACEMENT AS PER JHA ANNEXE TO EXISTING DOWNPIPES TO BE CONFIRMED BY SERVICES ENGINEERS.

BUILDING CONTRACT 2 REPORT AND DRAWINGS ALLOWANCE FOR NEW TEMPORARY DOWNPIPES TO BE MADE (CURRENTLY DOWNPIPES ARE
LOCATED WITHIN THE CROSS WALLS EVERY TWO UNITS)

EXISTING SARKINGS OMITTED FOR CLARITY.


CONDITION TO BE ESTABLISHED ONCE ROOF SLATES ARE REMOVED.

WALLPLATE REPAIR/REPLACEMENT AS PER JHA ALL REPAIRS REPLACEMENT DETAILS ARE BASED ON LIMITED SURVEY

ANNEXE BUILDING CONTRACT 2 REPORT AND


INFORMATION. THE CONTRACTOR TOGETHER WITH THE TIMBER SPECIALIST IS TO
ESTABLISH THE EXTENT OF ROT BEFORE COMMENCEMENT OF ANY REPAIRS

DRAWINGS
WORKS.

ANY DISCREPANCIES BETWEEN EXISTING STRUCTURE SHOWN ON DRAWING AND


EXISTING STRUCTURE EXPOSED ON SITE TO BE BROUGHT TO THE ATTENTION OF
THE STRUCTURAL ENGINEER.

SALVAGED SOUND TIMBER TO BE


REFER TO DRAWINGS 4525-S-HSK-EW-020 RE-USED WHERE APPROPRIATE
SERIES FOR TEMPORARY PROPPING DETAILS

DETAILS TO BE UPDATED UPON RECEIPT


OF SURVEY INFORMATION PROVIDED BY
THE CONTRACTOR
Units 602 to 606

Units 612 to 614 & 616 to 617


& 619 to 622
MUSEUM OF LONDON CONTRACT 2 - ROOF REPAIRS - UNITS 602 TO 606, 612 TO 614, 616 TO
ANNEXE BUILDING - FISH MARKET 617 AND 619 TO 621 - PLANS - ASSUMED
PROJECT TITLE

T1 23.08.2019 TENDER DO VG DATE JUN 2019 SCALE NTS CAD FILENAME STATUS
TENDER
P2 09.08.2019 TENDER DRAFT DO VG
P1 07.06.2019 FOR COMMENTS MK VG
REV DATE DESCRIPTION BY CHECKED DRAWN MK CHECKED VG PROJECT No.
4525 DRAWING No. 4525-S-HSK-EW-010 REV T1
NOTES
REFER TO DRAWINGS 4525-S-HSK-EW-020 1 DO NOT SCALE FROM THIS DRAWING.
SERIES FOR TEMPORARY PROPPING DETAILS 2 ALL DIMENSIONS ARE IN MILLIMETRES (mm) AND ALL LEVEL ARE IN METRES (m)
UNLESS NOTED OTHERWISE.
3 THIS DRAWING IS TO BE PRINTED IN COLOUR.

FOR FULL SECTION SIZES, REFER TO ANNOTATED SKETCHES IN THIS DOCUMENT

PRESERVATIVE TREATMENT: ORGANIC SOLVENT IMPREGNATION TO NBS SECTION Z12


AND WOOD PROTECTION ASSOCIATION COMMODITY SPECIFICATION C8
DESIGN SERVICE LIFE: 60 YEARS.TBC
FIRE RETARDANT TREATMENT: AS PER GENERAL NOTES

ROOF STRUCTURE
EXISTING 50 X 150 mm RIDGE BEAM (DIMENSIONS ASSUMED) RAFTERS ASSUMED AT 0.4m CENTRES, ASSUMED DIMENSION 150x50mm.
RAFTERS ARE SUPPORTED BY THE MASONRY WALL AND A TIMBER WALLPLATE

FOR LOADING ALLOWANCES REFER TO 4525 - GENERAL NOTES.

ALL ASSUMED DIMENSIONS TO BE CONFIRMED ON SITE.


REPAIR WORKS TO BE CARRIED OUT ONLY AFTER THE ROT AND INFESTATION SURVEY
(CONDITION SURVEY), IN ORDER TO DEFINE THE EXTENT OF ROT AND TO CONFIRM THE
FEASIBILITY OF THESE REPAIRS.

NOTE THAT THE MASONRY WALLS ARE LIKELY TO REQUIRE TREATMENT TO DRY ROT AND
FINISHES TO BE REMOVED TO PREVENT THE RE-INFECTION OF THE TIMBER ELEMENTS.
TEMPORARY PROPPING TO SUPPORT STRUCTURE WHILST REPAIRS ARE UNDERTAKEN
ARE NOT SHOWN FOR CLARITY.
EXISTING 50 X 150 mm TIMBER COMMON CONTRACTOR TO ALLOW FOR AN ELEMENT OF ADJUSTING OF TEMPORARY WORKS TO
RAFTER ALLOW REPAIRS TO BE CARRIED OUT.
ADDITIONAL TIME FRAME IN THE PROGRAMME AND CONTINGENCY IN THE COST PLAN TO
EXISTING 50 X 150 mm TIMBER COMMON RESPOND TO EXPOSED POTENTIAL DEFECTS IN THE EXISTING STRUCTURE AND THE
RAFTER EXISTING STRUCTURE BEING DIFFERENT THAN ASSUMED AND SHOWN ON THIS DRAWING.

SPECIFICATION FOR CONCRETE PADSTONES

-COMPRESSIVE STRENGTH CLASS (CYLINDER/ CUBE MINIMUM): C25/30


-TARGET DENSITY (OVEN-DRY): NORMAL.
-FIBRES: NOT REQUIRED.
-AGGREGATE SIZE (MAXIMUM): 20MM TYPE/ DENSITY: NORMAL WEIGHT.
-COARSE RECYCLED AGGREGATES: RA NOT PERMITTED, RCA OF LOCAL SUPPLY WITHIN
30KM OF SITE TO BS8500-2-2006 TABLE 2 AND 3, MASS FRACTION NOT EXCEEDING 20% OF
COARSE AGGREGATES PERMISSIBLE.
-ADDITIONAL AGGREGATE REQUIREMENTS: ALL AGGREGATES TO CONFORM TO BS EN
12620.
-DESIGN CHEMICAL CLASS: CLASS DS-1 TO DS-3 AND ACEC AC-1 TO AC-3 OF TABLE C2 OF
ASSUMED NON-STRUCTURAL BRE SPECIAL DIGEST 1 PART C (2005). ENVIRONMENTAL CLASS: XC1
TIMBER ELEMENT LIMITING VALUES FOR COMPOSITION:
-WATER:CEMENT RATIO (MAXIMUM): AS DC CLASS.
-CEMENT/ COMBINATION CONTENT (MINIMUM): AS PER ENVIRONMENTAL CLASS.
-CEMENT/ COMBINATION CONTENT (MAXIMUM): AS PER ENVIRONMENTAL CLASS.
-AIR CONTENT IN SITU (MINIMUM): NO REQUIREMENT.
-CONSISTENCE CLASS: CONTRACTOR’S CHOICE.
-PERMITTED CEMENT/ COMBINATIONS: AS PER ENVIRONMENTAL CLASS.
VALLEY GUTTER DETAILS SUBJECT TO
-CHLORIDE CLASS: BIP 2001: GENERALLY CL 0.40.
SURVEYS AND INVESTIGATION WORKS
-COLOUR: NOT REQUIRED.
-ADDITIONAL MIX REQUIREMENTS: WHERE SECONDARY AGGREGATES ARE USED WITH
APPROVAL ADDITIONAL AGGREGATE TESTING WILL BE REQUIRED INCLUDING REGULAR
TESTING OF WATER ABSORPTION. FULL REGIME TO BE AGREED SUBJECT TO IDENTIFYING
SUPPLY.

METAL STRAPS,FRAMING ANCHORS, REINFORCED ANGLED BRACKETS AND PROPRIETARY


EXISTING 50 X 150 mm TIMBER COLLAR TIE PRODUCTS

-MANUFACTURER: SIMPSON, OR SIMILAR APPROVED BY THE STRUCTURAL ENGINEER.


-PRODUCT REFERENCE: REFER TO DETAILS, OR SIMILAR APPROVED BY THE STRUCTURAL
ENGINEER.
-MATERIAL/ FINISH: MATERIAL/ FINISH: STAINLESS STEEL GRADE 304 TO BS EN 10088-2
-FASTENERS: STAINLESS STEEL
-FIXING: SECURE USING NOT LESS THAN THE NUMBER OF NAILS RECOMMENDED BY
ANCHOR MANUFACTURER.

POTENTIAL EXTENT OF ROT NOT VISIBLE BUT MOISTURE CONTENT > THAN 20%
TIMBER SPECIALIST/CONTRACTOR TO CONFIRM MOISTURE CONTENT IN TIMBER JOISTS AND
EXTENT

EXISTING 50 X 130 mm TIMBER BEARING WALL PLATE REPLACEMENT AND IMPLEMENTATION OF THE GUTTER STRUCTURE REQUIRED. CONNECTION
EXISTING 50 X 130 mm TIMBER BEARING WALL PLATE TO EXISTING DOWNPIPES TO BE CONFIRMED BY SERVICES ENGINEERS.

ALLOWANCE FOR NEW TEMPORARY DOWNPIPES TO BE MADE (CURRENTLY DOWNPIPES ARE


LOCATED WITHIN THE CROSS WALLS EVERY TWO UNITS)

EXISTING SARKINGS OMITTED FOR CLARITY.


CONDITION TO BE ESTABLISHED ONCE ROOF SLATES ARE REMOVED.

ALL REPAIRS REPLACEMENT DETAILS ARE BASED ON LIMITED SURVEY


INFORMATION. THE CONTRACTOR TOGETHER WITH THE TIMBER SPECIALIST IS TO
ESTABLISH THE EXTENT OF ROT BEFORE COMMENCEMENT OF ANY REPAIRS
WORKS.

ANY DISCREPANCIES BETWEEN EXISTING STRUCTURE SHOWN ON DRAWING AND

SECTION A - A
EXISTING STRUCTURE EXPOSED ON SITE TO BE BROUGHT TO THE ATTENTION OF
THE STRUCTURAL ENGINEER.

ASSUMED EXISTING SECTION - UNIT 602 & 606


SALVAGED SOUND TIMBER TO BE
RE-USED WHERE APPROPRIATE

DETAILS TO BE UPDATED UPON RECEIPT


OF SURVEY INFORMATION PROVIDED BY
THE CONTRACTOR

MUSEUM OF LONDON CONTRACT 2 - ROOF REPAIRS - UNITS 602 TO 606, 612 TO 614, 616 TO
ANNEXE BUILDING - FISH MARKET 617 AND 619 TO 621 - PRIMARY TIMBER MEMBERS - EXISTING SECTION
PROJECT TITLE ASSUMED - SECTION A-A

T1 23.08.2019 TENDER DO VG DATE JUN 2019 SCALE NTS CAD FILENAME STATUS
TENDER
P2 09.08.2019 TENDER DRAFT DO VG
P1 07.06.2019 FOR COMMENTS MK VG
REV DATE DESCRIPTION BY CHECKED DRAWN MK CHECKED VG PROJECT No.
4525 DRAWING No. 4525-S-HSK-EW-010A REV T1
NOTES

TIMBER WITH NO DECAY DO NOT REFER TO DRAWINGS 4525-S-HSK-EW-020 1 DO NOT SCALE FROM THIS DRAWING.

NEED ANY SERIES FOR TEMPORARY PROPPING DETAILS 2 ALL DIMENSIONS ARE IN MILLIMETRES (mm) AND ALL LEVEL ARE IN METRES (m)
UNLESS NOTED OTHERWISE.
3 THIS DRAWING IS TO BE PRINTED IN COLOUR.
REPAIR/REPLACEMENT
FOR FULL SECTION SIZES, REFER TO ANNOTATED SKETCHES IN THIS DOCUMENT

PRESERVATIVE TREATMENT: ORGANIC SOLVENT IMPREGNATION TO NBS SECTION Z12


EPDM OR SIMILAR ISOLATING AND WOOD PROTECTION ASSOCIATION COMMODITY SPECIFICATION C8
DESIGN SERVICE LIFE: 60 YEARS.TBC
MEMBRANE TO JOIST ENDS AT FIRE RETARDANT TREATMENT: AS PER GENERAL NOTES

WALL CONNECTION ROOF STRUCTURE


RAFTERS ASSUMED AT 0.4m CENTRES, ASSUMED DIMENSION 150x50mm.
RAFTERS ARE SUPPORTED BY THE MASONRY WALL AND A TIMBER WALLPLATE
KEY LEGEND:
FOR LOADING ALLOWANCES REFER TO 4525 - GENERAL NOTES.

TIMBER DECAY OF RAFTER UP TEMPORARY LATERAL PROPS TO BE PROVIDED EXTENT OF VISUAL ROT, ACCORDING TO JHA
ALL ASSUMED DIMENSIONS TO BE CONFIRMED ON SITE.
REPAIR WORKS TO BE CARRIED OUT ONLY AFTER THE ROT AND INFESTATION SURVEY
TO 800mm FROM WALL PLATE TO FOR OVERALL STRUCTURAL STABILITY. REFER TO
DRAWINGS 4525-S-HSK-EW-020 SERIES FOR ANNEXE BUILDING CONTRACT 2 REPORT (CONDITION SURVEY), IN ORDER TO DEFINE THE EXTENT OF ROT AND TO CONFIRM THE
FEASIBILITY OF THESE REPAIRS.
BE TEMPORARY PROPPING DETAILS
AND DRAWINGS
NOTE THAT THE MASONRY WALLS ARE LIKELY TO REQUIRE TREATMENT TO DRY ROT AND
REPAIRED WHERE NEEDED. POTENTIAL ASSUMED EXTENT OF ROT NOT FINISHES TO BE REMOVED TO PREVENT THE RE-INFECTION OF THE TIMBER ELEMENTS.
TEMPORARY PROPPING TO SUPPORT STRUCTURE WHILST REPAIRS ARE UNDERTAKEN
IF DECAY EXCEEDS THIS VALUE VISIBLE BUT MOISTURE CONTENT > THAN 20% ARE NOT SHOWN FOR CLARITY.
CONTRACTOR TO ALLOW FOR AN ELEMENT OF ADJUSTING OF TEMPORARY WORKS TO
REPLACE TIMBER SPECIALIST/CONTRACTOR TO ALLOW REPAIRS TO BE CARRIED OUT.
CONFIRM MOISTURE CONTENT IN TIMBER ADDITIONAL TIME FRAME IN THE PROGRAMME AND CONTINGENCY IN THE COST PLAN TO
FULL TIMBER RAFTER. RAFTERS AND EXTENT
RESPOND TO EXPOSED POTENTIAL DEFECTS IN THE EXISTING STRUCTURE AND THE
EXISTING STRUCTURE BEING DIFFERENT THAN ASSUMED AND SHOWN ON THIS DRAWING.

SPECIFICATION FOR CONCRETE PADSTONES

-COMPRESSIVE STRENGTH CLASS (CYLINDER/ CUBE MINIMUM): C25/30


-TARGET DENSITY (OVEN-DRY): NORMAL.
-FIBRES: NOT REQUIRED.
-AGGREGATE SIZE (MAXIMUM): 20MM TYPE/ DENSITY: NORMAL WEIGHT.
-COARSE RECYCLED AGGREGATES: RA NOT PERMITTED, RCA OF LOCAL SUPPLY WITHIN
30KM OF SITE TO BS8500-2-2006 TABLE 2 AND 3, MASS FRACTION NOT EXCEEDING 20% OF
COARSE AGGREGATES PERMISSIBLE.
-ADDITIONAL AGGREGATE REQUIREMENTS: ALL AGGREGATES TO CONFORM TO BS EN
12620.
-DESIGN CHEMICAL CLASS: CLASS DS-1 TO DS-3 AND ACEC AC-1 TO AC-3 OF TABLE C2 OF
BRE SPECIAL DIGEST 1 PART C (2005). ENVIRONMENTAL CLASS: XC1
LIMITING VALUES FOR COMPOSITION:
-WATER:CEMENT RATIO (MAXIMUM): AS DC CLASS.
-CEMENT/ COMBINATION CONTENT (MINIMUM): AS PER ENVIRONMENTAL CLASS.
-CEMENT/ COMBINATION CONTENT (MAXIMUM): AS PER ENVIRONMENTAL CLASS.
-AIR CONTENT IN SITU (MINIMUM): NO REQUIREMENT.
-CONSISTENCE CLASS: CONTRACTOR’S CHOICE.
-PERMITTED CEMENT/ COMBINATIONS: AS PER ENVIRONMENTAL CLASS.
VALLEY GUTTER DETAILS SUBJECT TO -CHLORIDE CLASS: BIP 2001: GENERALLY CL 0.40.
SURVEYS AND INVESTIGATION WORKS -COLOUR: NOT REQUIRED.
-ADDITIONAL MIX REQUIREMENTS: WHERE SECONDARY AGGREGATES ARE USED WITH
APPROVAL ADDITIONAL AGGREGATE TESTING WILL BE REQUIRED INCLUDING REGULAR
50 TESTING OF WATER ABSORPTION. FULL REGIME TO BE AGREED SUBJECT TO IDENTIFYING
m 0 SUPPLY.
m m
5 00 m METAL STRAPS,FRAMING ANCHORS, REINFORCED ANGLED BRACKETS AND PROPRIETARY
TEMPORARY PROPS FOR PRODUCTS
COLLARS AND RAFTERS
WHILE REPAIR WORKS ARE -MANUFACTURER: SIMPSON, OR SIMILAR APPROVED BY THE STRUCTURAL ENGINEER.
CARRIED OUT - TO BE -PRODUCT REFERENCE: REFER TO DETAILS, OR SIMILAR APPROVED BY THE STRUCTURAL
DETERMINED BY ENGINEER.
CONTRACTOR -MATERIAL/ FINISH: MATERIAL/ FINISH: STAINLESS STEEL GRADE 304 TO BS EN 10088-2
m 57 -FASTENERS: STAINLESS STEEL
REFER TO DRAWINGS 5
m 4525-S-HSK-EW-020 SERIES m -FIXING: SECURE USING NOT LESS THAN THE NUMBER OF NAILS RECOMMENDED BY
5 ANCHOR MANUFACTURER.
57 FOR TEMPORARY PROPPING m
DETAILS

POTENTIAL EXTENT OF ROT NOT VISIBLE BUT MOISTURE CONTENT > THAN 20%
TIMBER SPECIALIST/CONTRACTOR TO CONFIRM MOISTURE CONTENT IN TIMBER JOISTS AND
FULL REPLACEMENT OF TIMBER BASE EXTENT
FULL REPLACEMENT OF TIMBER BASE PLATE
PLATE
REPLACEMENT AND IMPLEMENTATION OF THE GUTTER STRUCTURE REQUIRED. CONNECTION
TO EXISTING DOWNPIPES TO BE CONFIRMED BY SERVICES ENGINEERS.
TEMPORARY LATERAL PROPS TO BE PROVIDED TEMPORARY LATERAL PROPS TO BE PROVIDED
FOR OVERALL STRUCTURAL STABILITY. REFER TO FOR OVERALL STRUCTURAL STABILITY. REFER TO ALLOWANCE FOR NEW TEMPORARY DOWNPIPES TO BE MADE (CURRENTLY DOWNPIPES ARE
DRAWINGS 4525-S-HSK-EW-020 SERIES FOR DRAWINGS 4525-S-HSK-EW-020 SERIES FOR LOCATED WITHIN THE CROSS WALLS EVERY TWO UNITS)
TEMPORARY PROPPING DETAILS TEMPORARY PROPPING DETAILS
EXISTING SARKINGS OMITTED FOR CLARITY.
CONDITION TO BE ESTABLISHED ONCE ROOF SLATES ARE REMOVED.

ALL REPAIRS REPLACEMENT DETAILS ARE BASED ON LIMITED SURVEY


INFORMATION. THE CONTRACTOR TOGETHER WITH THE TIMBER SPECIALIST IS TO
ESTABLISH THE EXTENT OF ROT BEFORE COMMENCEMENT OF ANY REPAIRS
WORKS.

ANY DISCREPANCIES BETWEEN EXISTING STRUCTURE SHOWN ON DRAWING AND


EXISTING STRUCTURE EXPOSED ON SITE TO BE BROUGHT TO THE ATTENTION OF
THE STRUCTURAL ENGINEER.

SECTION A - A
ASSUMED EXISTING CONDITION - UNIT 602 & 606 SALVAGED SOUND TIMBER TO BE
RE-USED WHERE APPROPRIATE

DETAILS TO BE UPDATED UPON RECEIPT


OF SURVEY INFORMATION PROVIDED BY
THE CONTRACTOR

MUSEUM OF LONDON CONTRACT 2 - ROOF REPAIRS - UNITS 602 TO 606, 612 TO 614, 616 TO
ANNEXE BUILDING - FISH MARKET 617 AND 619 TO 621 - PRIMARY TIMBER MEMBERS - EXTENT OF
PROJECT TITLE PROPOSED REPAIRS - SECTION A-A

T1 23.08.2019 TENDER DO VG DATE JUN 2019 SCALE NTS CAD FILENAME STATUS
TENDER
P2 09.08.2019 TENDER DRAFT DO VG
P1 07.06.2019 FOR COMMENTS MK VG
REV DATE DESCRIPTION BY CHECKED DRAWN MK CHECKED VG PROJECT No.
4525 DRAWING No. 4525-S-HSK-EW-010B REV T1
NOTES
REFER TO DRAWINGS 4525-S-HSK-EW-020 1 DO NOT SCALE FROM THIS DRAWING.
SERIES FOR TEMPORARY PROPPING DETAILS 2 ALL DIMENSIONS ARE IN MILLIMETRES (mm) AND ALL LEVEL ARE IN METRES (m)
UNLESS NOTED OTHERWISE.
3 THIS DRAWING IS TO BE PRINTED IN COLOUR.

FOR FULL SECTION SIZES, REFER TO ANNOTATED SKETCHES IN THIS DOCUMENT

PRESERVATIVE TREATMENT: ORGANIC SOLVENT IMPREGNATION TO NBS SECTION Z12


AND WOOD PROTECTION ASSOCIATION COMMODITY SPECIFICATION C8
DESIGN SERVICE LIFE: 60 YEARS.TBC
FIRE RETARDANT TREATMENT: AS PER GENERAL NOTES

ROOF STRUCTURE
EXISTING 50 X 150 mm RIDGE BEAM (DIMENSIONS ASSUMED) RAFTERS ASSUMED AT 0.4m CENTRES, ASSUMED DIMENSION 150x50mm.
RAFTERS ARE SUPPORTED BY THE MASONRY WALL AND A TIMBER WALLPLATE

FOR LOADING ALLOWANCES REFER TO 4525 - GENERAL NOTES.

ALL ASSUMED DIMENSIONS TO BE CONFIRMED ON SITE.


DORMER GEOMETRY ASSUMED AND REQUIRES REPAIR WORKS TO BE CARRIED OUT ONLY AFTER THE ROT AND INFESTATION SURVEY
(CONDITION SURVEY), IN ORDER TO DEFINE THE EXTENT OF ROT AND TO CONFIRM THE
CONFIRMATION. FEASIBILITY OF THESE REPAIRS.
REFER TO 4525-S-HSK-EW-018 SERIES FOR
NOTE THAT THE MASONRY WALLS ARE LIKELY TO REQUIRE TREATMENT TO DRY ROT AND
REPAIR DETAILS. FINISHES TO BE REMOVED TO PREVENT THE RE-INFECTION OF THE TIMBER ELEMENTS.
TEMPORARY PROPPING TO SUPPORT STRUCTURE WHILST REPAIRS ARE UNDERTAKEN
ARE NOT SHOWN FOR CLARITY.
CONTRACTOR TO ALLOW FOR AN ELEMENT OF ADJUSTING OF TEMPORARY WORKS TO
ALLOW REPAIRS TO BE CARRIED OUT.
ADDITIONAL TIME FRAME IN THE PROGRAMME AND CONTINGENCY IN THE COST PLAN TO
RESPOND TO EXPOSED POTENTIAL DEFECTS IN THE EXISTING STRUCTURE AND THE
EXISTING 50 X 150 mm TIMBER COMMON RAFTER EXISTING STRUCTURE BEING DIFFERENT THAN ASSUMED AND SHOWN ON THIS DRAWING.

SPECIFICATION FOR CONCRETE PADSTONES

-COMPRESSIVE STRENGTH CLASS (CYLINDER/ CUBE MINIMUM): C25/30


-TARGET DENSITY (OVEN-DRY): NORMAL.
-FIBRES: NOT REQUIRED.
-AGGREGATE SIZE (MAXIMUM): 20MM TYPE/ DENSITY: NORMAL WEIGHT.
-COARSE RECYCLED AGGREGATES: RA NOT PERMITTED, RCA OF LOCAL SUPPLY WITHIN
30KM OF SITE TO BS8500-2-2006 TABLE 2 AND 3, MASS FRACTION NOT EXCEEDING 20% OF
COARSE AGGREGATES PERMISSIBLE.
-ADDITIONAL AGGREGATE REQUIREMENTS: ALL AGGREGATES TO CONFORM TO BS EN
12620.
-DESIGN CHEMICAL CLASS: CLASS DS-1 TO DS-3 AND ACEC AC-1 TO AC-3 OF TABLE C2 OF
ASSUMED NON-STRUCTURAL BRE SPECIAL DIGEST 1 PART C (2005). ENVIRONMENTAL CLASS: XC1
TIMBER ELEMENT LIMITING VALUES FOR COMPOSITION:
-WATER:CEMENT RATIO (MAXIMUM): AS DC CLASS.
-CEMENT/ COMBINATION CONTENT (MINIMUM): AS PER ENVIRONMENTAL CLASS.
-CEMENT/ COMBINATION CONTENT (MAXIMUM): AS PER ENVIRONMENTAL CLASS.
-AIR CONTENT IN SITU (MINIMUM): NO REQUIREMENT.
-CONSISTENCE CLASS: CONTRACTOR’S CHOICE.
VALLEY GUTTER DETAILS SUBJECT TO -PERMITTED CEMENT/ COMBINATIONS: AS PER ENVIRONMENTAL CLASS.
SURVEYS AND INVESTIGATION WORKS -CHLORIDE CLASS: BIP 2001: GENERALLY CL 0.40.
-COLOUR: NOT REQUIRED.
-ADDITIONAL MIX REQUIREMENTS: WHERE SECONDARY AGGREGATES ARE USED WITH
APPROVAL ADDITIONAL AGGREGATE TESTING WILL BE REQUIRED INCLUDING REGULAR
TESTING OF WATER ABSORPTION. FULL REGIME TO BE AGREED SUBJECT TO IDENTIFYING
SUPPLY.
EXISTING 50 X 150 mm TIMBER COLLAR TIE METAL STRAPS,FRAMING ANCHORS, REINFORCED ANGLED BRACKETS AND PROPRIETARY
PRODUCTS

-MANUFACTURER: SIMPSON, OR SIMILAR APPROVED BY THE STRUCTURAL ENGINEER.


-PRODUCT REFERENCE: REFER TO DETAILS, OR SIMILAR APPROVED BY THE STRUCTURAL
ENGINEER.
-MATERIAL/ FINISH: MATERIAL/ FINISH: STAINLESS STEEL GRADE 304 TO BS EN 10088-2
-FASTENERS: STAINLESS STEEL
-FIXING: SECURE USING NOT LESS THAN THE NUMBER OF NAILS RECOMMENDED BY
ANCHOR MANUFACTURER.

POTENTIAL EXTENT OF ROT NOT VISIBLE BUT MOISTURE CONTENT > THAN 20%
TIMBER SPECIALIST/CONTRACTOR TO CONFIRM MOISTURE CONTENT IN TIMBER JOISTS AND
EXTENT
EXISTING 50 X 130 mm TIMBER BEARING WALL PLATE EXISTING 50 X 130 mm TIMBER BEARING WALL PLATE
REPLACEMENT AND IMPLEMENTATION OF THE GUTTER STRUCTURE REQUIRED. CONNECTION
TO EXISTING DOWNPIPES TO BE CONFIRMED BY SERVICES ENGINEERS.

ALLOWANCE FOR NEW TEMPORARY DOWNPIPES TO BE MADE (CURRENTLY DOWNPIPES ARE


LOCATED WITHIN THE CROSS WALLS EVERY TWO UNITS)

EXISTING SARKINGS OMITTED FOR CLARITY.


CONDITION TO BE ESTABLISHED ONCE ROOF SLATES ARE REMOVED.

ALL REPAIRS REPLACEMENT DETAILS ARE BASED ON LIMITED SURVEY


INFORMATION. THE CONTRACTOR TOGETHER WITH THE TIMBER SPECIALIST IS TO
ESTABLISH THE EXTENT OF ROT BEFORE COMMENCEMENT OF ANY REPAIRS
WORKS.

ANY DISCREPANCIES BETWEEN EXISTING STRUCTURE SHOWN ON DRAWING AND

SECTION B-B
EXISTING STRUCTURE EXPOSED ON SITE TO BE BROUGHT TO THE ATTENTION OF
THE STRUCTURAL ENGINEER.

ASSUMED EXISTING SECTION - UNIT 612 TO 614 & 616 TO 617


SALVAGED SOUND TIMBER TO BE
RE-USED WHERE APPROPRIATE

DETAILS TO BE UPDATED UPON RECEIPT


OF SURVEY INFORMATION PROVIDED BY
THE CONTRACTOR

MUSEUM OF LONDON CONTRACT 2 - ROOF REPAIRS - UNITS 602 TO 606, 612 TO 614, 616 TO
ANNEXE BUILDING - FISH MARKET 617 AND 619 TO 621 - PRIMARY TIMBER MEMBERS - EXISTING SECTION
PROJECT TITLE ASSUMED - SECTION B-B

T1 23.08.2019 TENDER DO VG DATE JUN 2019 SCALE NTS CAD FILENAME TENDER
STATUS
P2 09.08.2019 TENDER DRAFT DO VG
P1 07.06.2019 FOR COMMENTS MK VG
REV DATE DESCRIPTION BY CHECKED DRAWN MK CHECKED VG PROJECT No.
4525 DRAWING No. 4525-S-HSK-EW-010C REV T1
TIMBER WITH NO DECAY DO NOT EPDM OR SIMILAR ISOLATING NOTES
NEED ANY MEMBRANE TO JOIST ENDS AT REFER TO DRAWINGS 4525-S-HSK-EW-020 1 DO NOT SCALE FROM THIS DRAWING.
REPAIR/REPLACEMENT WALL CONNECTION SERIES FOR TEMPORARY PROPPING DETAILS 2 ALL DIMENSIONS ARE IN MILLIMETRES (mm) AND ALL LEVEL ARE IN METRES (m)
UNLESS NOTED OTHERWISE.
3 THIS DRAWING IS TO BE PRINTED IN COLOUR.

TIMBER DECAY OF RAFTER UP FOR FULL SECTION SIZES, REFER TO ANNOTATED SKETCHES IN THIS DOCUMENT

TO 800mm FROM WALL PLATE TO PRESERVATIVE TREATMENT: ORGANIC SOLVENT IMPREGNATION TO NBS SECTION Z12
AND WOOD PROTECTION ASSOCIATION COMMODITY SPECIFICATION C8
BE DESIGN SERVICE LIFE: 60 YEARS.TBC
FIRE RETARDANT TREATMENT: AS PER GENERAL NOTES
REPAIRED WHERE NEEDED. ROOF STRUCTURE
IF DECAY EXCEEDS THIS VALUE RAFTERS ASSUMED AT 0.4m CENTRES, ASSUMED DIMENSION 150x50mm.
RAFTERS ARE SUPPORTED BY THE MASONRY WALL AND A TIMBER WALLPLATE
KEY LEGEND:
REPLACE FOR LOADING ALLOWANCES REFER TO 4525 - GENERAL NOTES.
TEMPORARY LATERAL PROPS TO BE PROVIDED FULL TIMBER RAFTER. ALL ASSUMED DIMENSIONS TO BE CONFIRMED ON SITE.
FOR OVERALL STRUCTURAL STABILITY. REFER TO
DRAWINGS 4525-S-HSK-EW-020 SERIES FOR
EXTENT OF VISUAL ROT, ACCORDING TO JHA REPAIR WORKS TO BE CARRIED OUT ONLY AFTER THE ROT AND INFESTATION SURVEY
TEMPORARY PROPPING DETAILS ANNEXE BUILDING CONTRACT 2 REPORT (CONDITION SURVEY), IN ORDER TO DEFINE THE EXTENT OF ROT AND TO CONFIRM THE
FEASIBILITY OF THESE REPAIRS.
AND DRAWINGS
FOR DORMER REPAIR DETAILS, NOTE THAT THE MASONRY WALLS ARE LIKELY TO REQUIRE TREATMENT TO DRY ROT AND
REFER TO 4525-S-HSK-EW-018
SERIES
POTENTIAL ASSUMED EXTENT OF ROT NOT FINISHES TO BE REMOVED TO PREVENT THE RE-INFECTION OF THE TIMBER ELEMENTS.
TEMPORARY PROPPING TO SUPPORT STRUCTURE WHILST REPAIRS ARE UNDERTAKEN
VISIBLE BUT MOISTURE CONTENT > THAN 20% ARE NOT SHOWN FOR CLARITY.
CONTRACTOR TO ALLOW FOR AN ELEMENT OF ADJUSTING OF TEMPORARY WORKS TO
TIMBER SPECIALIST/CONTRACTOR TO ALLOW REPAIRS TO BE CARRIED OUT.
CONFIRM MOISTURE CONTENT IN TIMBER ADDITIONAL TIME FRAME IN THE PROGRAMME AND CONTINGENCY IN THE COST PLAN TO
RESPOND TO EXPOSED POTENTIAL DEFECTS IN THE EXISTING STRUCTURE AND THE
RAFTERS AND EXTENT EXISTING STRUCTURE BEING DIFFERENT THAN ASSUMED AND SHOWN ON THIS DRAWING.

SPECIFICATION FOR CONCRETE PADSTONES

-COMPRESSIVE STRENGTH CLASS (CYLINDER/ CUBE MINIMUM): C25/30


-TARGET DENSITY (OVEN-DRY): NORMAL.
-FIBRES: NOT REQUIRED.
-AGGREGATE SIZE (MAXIMUM): 20MM TYPE/ DENSITY: NORMAL WEIGHT.
TEMPORARY PROPS TO BE
-COARSE RECYCLED AGGREGATES: RA NOT PERMITTED, RCA OF LOCAL SUPPLY WITHIN
PROVIDED TO DORMER IF IN
30KM OF SITE TO BS8500-2-2006 TABLE 2 AND 3, MASS FRACTION NOT EXCEEDING 20% OF
SOUND CONDITION.
COARSE AGGREGATES PERMISSIBLE.
REFER TO DRAWINGS
-ADDITIONAL AGGREGATE REQUIREMENTS: ALL AGGREGATES TO CONFORM TO BS EN
4525-S-HSK-EW-020 SERIES
12620.
FOR TEMPORARY PROPPING
-DESIGN CHEMICAL CLASS: CLASS DS-1 TO DS-3 AND ACEC AC-1 TO AC-3 OF TABLE C2 OF
DETAILS
BRE SPECIAL DIGEST 1 PART C (2005). ENVIRONMENTAL CLASS: XC1
LIMITING VALUES FOR COMPOSITION:
-WATER:CEMENT RATIO (MAXIMUM): AS DC CLASS.
-CEMENT/ COMBINATION CONTENT (MINIMUM): AS PER ENVIRONMENTAL CLASS.
-CEMENT/ COMBINATION CONTENT (MAXIMUM): AS PER ENVIRONMENTAL CLASS.
-AIR CONTENT IN SITU (MINIMUM): NO REQUIREMENT.
-CONSISTENCE CLASS: CONTRACTOR’S CHOICE.
-PERMITTED CEMENT/ COMBINATIONS: AS PER ENVIRONMENTAL CLASS.
VALLEY GUTTER DETAILS SUBJECT TO -CHLORIDE CLASS: BIP 2001: GENERALLY CL 0.40.
SURVEYS AND INVESTIGATION WORKS -COLOUR: NOT REQUIRED.
-ADDITIONAL MIX REQUIREMENTS: WHERE SECONDARY AGGREGATES ARE USED WITH
APPROVAL ADDITIONAL AGGREGATE TESTING WILL BE REQUIRED INCLUDING REGULAR
m TESTING OF WATER ABSORPTION. FULL REGIME TO BE AGREED SUBJECT TO IDENTIFYING
m SUPPLY.
0 50
50 0
m METAL STRAPS,FRAMING ANCHORS, REINFORCED ANGLED BRACKETS AND PROPRIETARY
m PRODUCTS
TEMPORARY PROPS FOR
COLLARS AND RAFTERS WHILE -MANUFACTURER: SIMPSON, OR SIMILAR APPROVED BY THE STRUCTURAL ENGINEER.
REPAIR WORKS ARE CARRIED -PRODUCT REFERENCE: REFER TO DETAILS, OR SIMILAR APPROVED BY THE STRUCTURAL
OUT - TO BE DETERMINED BY ENGINEER.
CONTRACTOR. -MATERIAL/ FINISH: MATERIAL/ FINISH: STAINLESS STEEL GRADE 304 TO BS EN 10088-2
m REFER TO DRAWINGS 50 -FASTENERS: STAINLESS STEEL
m 4525-S-HSK-EW-020 SERIES
5 0 -FIXING: SECURE USING NOT LESS THAN THE NUMBER OF NAILS RECOMMENDED BY
62 FOR TEMPORARY PROPPING
DETAILS
m
m ANCHOR MANUFACTURER.

POTENTIAL EXTENT OF ROT NOT VISIBLE BUT MOISTURE CONTENT > THAN 20%
TIMBER SPECIALIST/CONTRACTOR TO CONFIRM MOISTURE CONTENT IN TIMBER JOISTS AND
FULL REPLACEMENT OF TIMBER BASE EXTENT
FULL REPLACEMENT OF TIMBER BASE PLATE
PLATE
REPLACEMENT AND IMPLEMENTATION OF THE GUTTER STRUCTURE REQUIRED. CONNECTION
TO EXISTING DOWNPIPES TO BE CONFIRMED BY SERVICES ENGINEERS.
TEMPORARY LATERAL PROPS TO BE PROVIDED TEMPORARY LATERAL PROPS TO BE PROVIDED
FOR OVERALL STRUCTURAL STABILITY. REFER TO FOR OVERALL STRUCTURAL STABILITY. REFER TO ALLOWANCE FOR NEW TEMPORARY DOWNPIPES TO BE MADE (CURRENTLY DOWNPIPES ARE
DRAWINGS 4525-S-HSK-EW-020 SERIES FOR DRAWINGS 4525-S-HSK-EW-020 SERIES FOR LOCATED WITHIN THE CROSS WALLS EVERY TWO UNITS)
TEMPORARY PROPPING DETAILS TEMPORARY PROPPING DETAILS
EXISTING SARKINGS OMITTED FOR CLARITY.
CONDITION TO BE ESTABLISHED ONCE ROOF SLATES ARE REMOVED.

ALL REPAIRS REPLACEMENT DETAILS ARE BASED ON LIMITED SURVEY


INFORMATION. THE CONTRACTOR TOGETHER WITH THE TIMBER SPECIALIST IS TO
ESTABLISH THE EXTENT OF ROT BEFORE COMMENCEMENT OF ANY REPAIRS
WORKS.

ANY DISCREPANCIES BETWEEN EXISTING STRUCTURE SHOWN ON DRAWING AND


EXISTING STRUCTURE EXPOSED ON SITE TO BE BROUGHT TO THE ATTENTION OF
THE STRUCTURAL ENGINEER.

SECTION B-B
ASSUMED EXISTING CONDITION - UNIT 612 TO 614 & 616 TO 617 SALVAGED SOUND TIMBER TO BE
RE-USED WHERE APPROPRIATE

DETAILS TO BE UPDATED UPON RECEIPT


OF SURVEY INFORMATION PROVIDED BY
THE CONTRACTOR

MUSEUM OF LONDON CONTRACT 2 - ROOF REPAIRS - UNITS 602 TO 606, 612 TO 614, 616 TO
ANNEXE BUILDING - FISH MARKET 617 AND 619 TO 621 - PRIMARY TIMBER MEMBERS - EXTENT OF
PROJECT TITLE PROPOSED REPAIRS - SECTION B-B

T1 23.08.2019 TENDER DO VG DATE JUN 2019 SCALE NTS CAD FILENAME STATUS
TENDER
P2 09.08.2019 TENDER DRAFT DO VG
P1 07.06.2019 FOR COMMENTS MK VG
REV DATE DESCRIPTION BY CHECKED DRAWN MK CHECKED VG PROJECT No.
4525 DRAWING No. 4525-S-HSK-EW-010D REV T1
NOTES
REFER TO DRAWINGS 4525-S-HSK-EW-020 1 DO NOT SCALE FROM THIS DRAWING.
SERIES FOR TEMPORARY PROPPING DETAILS 2 ALL DIMENSIONS ARE IN MILLIMETRES (mm) AND ALL LEVEL ARE IN METRES (m)
UNLESS NOTED OTHERWISE.
3 THIS DRAWING IS TO BE PRINTED IN COLOUR.

FOR FULL SECTION SIZES, REFER TO ANNOTATED SKETCHES IN THIS DOCUMENT

PRESERVATIVE TREATMENT: ORGANIC SOLVENT IMPREGNATION TO NBS SECTION Z12


AND WOOD PROTECTION ASSOCIATION COMMODITY SPECIFICATION C8
DESIGN SERVICE LIFE: 60 YEARS.TBC
FIRE RETARDANT TREATMENT: AS PER GENERAL NOTES

ROOF STRUCTURE
RAFTERS ASSUMED AT 0.4m CENTRES, ASSUMED DIMENSION 150x50mm.
RAFTERS ARE SUPPORTED BY THE MASONRY WALL AND A TIMBER WALLPLATE

FOR LOADING ALLOWANCES REFER TO 4525 - GENERAL NOTES.


DETAIL 4 ALL ASSUMED DIMENSIONS TO BE CONFIRMED ON SITE.
REPAIR WORKS TO BE CARRIED OUT ONLY AFTER THE ROT AND INFESTATION SURVEY
(CONDITION SURVEY), IN ORDER TO DEFINE THE EXTENT OF ROT AND TO CONFIRM THE
FEASIBILITY OF THESE REPAIRS.

NOTE THAT THE MASONRY WALLS ARE LIKELY TO REQUIRE TREATMENT TO DRY ROT AND
FINISHES TO BE REMOVED TO PREVENT THE RE-INFECTION OF THE TIMBER ELEMENTS.
TEMPORARY PROPPING TO SUPPORT STRUCTURE WHILST REPAIRS ARE UNDERTAKEN
ARE NOT SHOWN FOR CLARITY.
CONTRACTOR TO ALLOW FOR AN ELEMENT OF ADJUSTING OF TEMPORARY WORKS TO
ALLOW REPAIRS TO BE CARRIED OUT.
ADDITIONAL TIME FRAME IN THE PROGRAMME AND CONTINGENCY IN THE COST PLAN TO
RESPOND TO EXPOSED POTENTIAL DEFECTS IN THE EXISTING STRUCTURE AND THE
EXISTING STRUCTURE BEING DIFFERENT THAN ASSUMED AND SHOWN ON THIS DRAWING.

SPECIFICATION FOR CONCRETE PADSTONES

-COMPRESSIVE STRENGTH CLASS (CYLINDER/ CUBE MINIMUM): C25/30


-TARGET DENSITY (OVEN-DRY): NORMAL.
-FIBRES: NOT REQUIRED.
-AGGREGATE SIZE (MAXIMUM): 20MM TYPE/ DENSITY: NORMAL WEIGHT.
-COARSE RECYCLED AGGREGATES: RA NOT PERMITTED, RCA OF LOCAL SUPPLY WITHIN
30KM OF SITE TO BS8500-2-2006 TABLE 2 AND 3, MASS FRACTION NOT EXCEEDING 20% OF
COARSE AGGREGATES PERMISSIBLE.
-ADDITIONAL AGGREGATE REQUIREMENTS: ALL AGGREGATES TO CONFORM TO BS EN
12620.
-DESIGN CHEMICAL CLASS: CLASS DS-1 TO DS-3 AND ACEC AC-1 TO AC-3 OF TABLE C2 OF
BRE SPECIAL DIGEST 1 PART C (2005). ENVIRONMENTAL CLASS: XC1
LIMITING VALUES FOR COMPOSITION:
-WATER:CEMENT RATIO (MAXIMUM): AS DC CLASS.
-CEMENT/ COMBINATION CONTENT (MINIMUM): AS PER ENVIRONMENTAL CLASS.
-CEMENT/ COMBINATION CONTENT (MAXIMUM): AS PER ENVIRONMENTAL CLASS.
-AIR CONTENT IN SITU (MINIMUM): NO REQUIREMENT.
-CONSISTENCE CLASS: CONTRACTOR’S CHOICE.
-PERMITTED CEMENT/ COMBINATIONS: AS PER ENVIRONMENTAL CLASS.
-CHLORIDE CLASS: BIP 2001: GENERALLY CL 0.40.
-COLOUR: NOT REQUIRED.
-ADDITIONAL MIX REQUIREMENTS: WHERE SECONDARY AGGREGATES ARE USED WITH
APPROVAL ADDITIONAL AGGREGATE TESTING WILL BE REQUIRED INCLUDING REGULAR
DETAIL 3 (MIRRORED) DETAIL 3
TESTING OF WATER ABSORPTION. FULL REGIME TO BE AGREED SUBJECT TO IDENTIFYING
SUPPLY.

METAL STRAPS,FRAMING ANCHORS, REINFORCED ANGLED BRACKETS AND PROPRIETARY


PRODUCTS

-MANUFACTURER: SIMPSON, OR SIMILAR APPROVED BY THE STRUCTURAL ENGINEER.


-PRODUCT REFERENCE: REFER TO DETAILS, OR SIMILAR APPROVED BY THE STRUCTURAL
ENGINEER.
-MATERIAL/ FINISH: MATERIAL/ FINISH: STAINLESS STEEL GRADE 304 TO BS EN 10088-2
-FASTENERS: STAINLESS STEEL
-FIXING: SECURE USING NOT LESS THAN THE NUMBER OF NAILS RECOMMENDED BY
ANCHOR MANUFACTURER.

POTENTIAL EXTENT OF ROT NOT VISIBLE BUT MOISTURE CONTENT > THAN 20%
TIMBER SPECIALIST/CONTRACTOR TO CONFIRM MOISTURE CONTENT IN TIMBER JOISTS AND
EXTENT

DETAIL 1 DETAIL 2 REPLACEMENT AND IMPLEMENTATION OF THE GUTTER STRUCTURE REQUIRED. CONNECTION
TO EXISTING DOWNPIPES TO BE CONFIRMED BY SERVICES ENGINEERS.

ALLOWANCE FOR NEW TEMPORARY DOWNPIPES TO BE MADE (CURRENTLY DOWNPIPES ARE


LOCATED WITHIN THE CROSS WALLS EVERY TWO UNITS)

EXISTING SARKINGS OMITTED FOR CLARITY.


CONDITION TO BE ESTABLISHED ONCE ROOF SLATES ARE REMOVED.

ALL REPAIRS REPLACEMENT DETAILS ARE BASED ON LIMITED SURVEY


INFORMATION. THE CONTRACTOR TOGETHER WITH THE TIMBER SPECIALIST IS TO
ESTABLISH THE EXTENT OF ROT BEFORE COMMENCEMENT OF ANY REPAIRS
WORKS.

ANY DISCREPANCIES BETWEEN EXISTING STRUCTURE SHOWN ON DRAWING AND

SECTION A - A
EXISTING STRUCTURE EXPOSED ON SITE TO BE BROUGHT TO THE ATTENTION OF
THE STRUCTURAL ENGINEER.

KEY REPAIRS
SALVAGED SOUND TIMBER TO BE
RE-USED WHERE APPROPRIATE

DETAILS TO BE UPDATED UPON RECEIPT


OF SURVEY INFORMATION PROVIDED BY
THE CONTRACTOR

MUSEUM OF LONDON CONTRACT 2 - ROOF REPAIRS - UNITS 602 TO 606, 612 TO 614, 616 TO
ANNEXE BUILDING - FISH MARKET 617 AND 619 TO 621 - KEY SECTIONS FOR TYPICAL DETAILS
PROJECT TITLE

T1 23.08.2019 TENDER DO VG DATE JUN 2019 SCALE NTS CAD FILENAME STATUS
TENDER
P2 09.08.2019 TENDER DRAFT DO VG
P1 07.06.2019 FOR COMMENTS MK VG
REV DATE DESCRIPTION BY CHECKED DRAWN MK CHECKED VG PROJECT No.
4525 DRAWING No. 4525-S-HSK-EW-010E REV T1
NOTES

1 DO NOT SCALE FROM THIS DRAWING.


EXISTING TIMBER 2 ALL DIMENSIONS ARE IN MILLIMETRES (mm) AND ALL LEVEL ARE IN METRES (m)
COMMON RAFTER UNLESS NOTED OTHERWISE.
3 THIS DRAWING IS TO BE PRINTED IN COLOUR.

FOR FULL SECTION SIZES, REFER TO ANNOTATED SKETCHES IN THIS DOCUMENT


R TEMPORARY PROP - REFER
BE K
TIM TAC TO DRAWINGS PRESERVATIVE TREATMENT: ORGANIC SOLVENT IMPREGNATION TO NBS SECTION Z12
HE L AT N LIST 0 4525-S-HSK-EW-020 SERIES AND WOOD PROTECTION ASSOCIATION COMMODITY SPECIFICATION C8
T O 15
OF SUA CTI CIA FOR TEMPORARY PROPPING DESIGN SERVICE LIFE: 60 YEARS.TBC
NT VI FE PE 0 FIRE RETARDANT TREATMENT: AS PER GENERAL NOTES
ME NY -IN R S EY 5No. M10 8.8 BOLTS 10 DETAILS
A CE OF A RE MBE URV
PL IT OID TI S 10
0
ROOF STRUCTURE
RE LIM AV HE ION
ER E TO Y T DIT 0 RAFTERS ASSUMED AT 0.4m CENTRES, ASSUMED DIMENSION 150x50mm.
RTH D TH ER D B ON 10 RAFTERS ARE SUPPORTED BY THE MASONRY WALL AND A TIMBER WALLPLATE

=
FU YON ORD IRME HE C 0
BE IN ONF ER T 10

=
C FT FOR LOADING ALLOWANCES REFER TO 4525 - GENERAL NOTES.
BE A 15
0
TO ALL ASSUMED DIMENSIONS TO BE CONFIRMED ON SITE.
REPAIR WORKS TO BE CARRIED OUT ONLY AFTER THE ROT AND INFESTATION SURVEY
ALLOW FOR 2 No. SIMPSON (CONDITION SURVEY), IN ORDER TO DEFINE THE EXTENT OF ROT AND TO CONFIRM THE
C

REINFORCED ANGLED BRACKETS FEASIBILITY OF THESE REPAIRS.


E5/2C50 OR SIMILAR FOR CONNECTION
A

BETWEEN BEARING PLATE AND NOTE THAT THE MASONRY WALLS ARE LIKELY TO REQUIRE TREATMENT TO DRY ROT AND
COMMON RAFTERS FINISHES TO BE REMOVED TO PREVENT THE RE-INFECTION OF THE TIMBER ELEMENTS.
B

NEW TIMBER COMMON RAFTER


E5/2C50
SIZE TO MATCH EXISTING TEMPORARY PROPPING TO SUPPORT STRUCTURE WHILST REPAIRS ARE UNDERTAKEN
ARE NOT SHOWN FOR CLARITY.
CONTRACTOR TO ALLOW FOR AN ELEMENT OF ADJUSTING OF TEMPORARY WORKS TO
APPROXIMATELY EXTENT OF ALLOW REPAIRS TO BE CARRIED OUT.
ROTTEN 150 mm DEEP X 50mm WIDE ADDITIONAL TIME FRAME IN THE PROGRAMME AND CONTINGENCY IN THE COST PLAN TO
COMMON RAFTERS RESPOND TO EXPOSED POTENTIAL DEFECTS IN THE EXISTING STRUCTURE AND THE
EXISTING STRUCTURE BEING DIFFERENT THAN ASSUMED AND SHOWN ON THIS DRAWING.

ALLOW FOR LES OR L-STRAPS SPECIFICATION FOR CONCRETE PADSTONES


TO WALL PLATE AND MASONRY.
SPACING AT 400 mm ALTERNATE -COMPRESSIVE STRENGTH CLASS (CYLINDER/ CUBE MINIMUM): C25/30
WALL STRAPS TO BE
TO TIMBER RAFTERS -TARGET DENSITY (OVEN-DRY): NORMAL.
PROVIDED AT ALTERNATE
-FIBRES: NOT REQUIRED.
RAFTER LOCATION
-AGGREGATE SIZE (MAXIMUM): 20MM TYPE/ DENSITY: NORMAL WEIGHT.
-COARSE RECYCLED AGGREGATES: RA NOT PERMITTED, RCA OF LOCAL SUPPLY WITHIN
TEMPORARY LATERAL PROPS TO BE PROVIDED 30KM OF SITE TO BS8500-2-2006 TABLE 2 AND 3, MASS FRACTION NOT EXCEEDING 20% OF
FOR OVERALL STRUCTURAL STABILITY. REFER TO COARSE AGGREGATES PERMISSIBLE.
DRAWINGS 4525-S-HSK-EW-020 SERIES FOR -ADDITIONAL AGGREGATE REQUIREMENTS: ALL AGGREGATES TO CONFORM TO BS EN
TEMPORARY PROPPING DETAILS 12620.
-DESIGN CHEMICAL CLASS: CLASS DS-1 TO DS-3 AND ACEC AC-1 TO AC-3 OF TABLE C2 OF
BRE SPECIAL DIGEST 1 PART C (2005). ENVIRONMENTAL CLASS: XC1
LIMITING VALUES FOR COMPOSITION:
-WATER:CEMENT RATIO (MAXIMUM): AS DC CLASS.
EXISTING -CEMENT/ COMBINATION CONTENT (MINIMUM): AS PER ENVIRONMENTAL CLASS.
MASONRY WALL FULL REPLACEMENT OF FIRST THREE COURSES.
DETAIL 1 ROTTEN COMMON RAFTER AT CONNECTION TO
-CEMENT/ COMBINATION CONTENT (MAXIMUM): AS PER ENVIRONMENTAL CLASS.
NEW BRICKS TO BE CROSS BONDED TO EXISTING. -AIR CONTENT IN SITU (MINIMUM): NO REQUIREMENT.
BRICKS AND MORTAR TO MATCH EXISTING.
MASONRY WALL - ASSUMED
-CONSISTENCE CLASS: CONTRACTOR’S CHOICE.
-PERMITTED CEMENT/ COMBINATIONS: AS PER ENVIRONMENTAL CLASS.
-CHLORIDE CLASS: BIP 2001: GENERALLY CL 0.40.
-COLOUR: NOT REQUIRED.
-ADDITIONAL MIX REQUIREMENTS: WHERE SECONDARY AGGREGATES ARE USED WITH
APPROVAL ADDITIONAL AGGREGATE TESTING WILL BE REQUIRED INCLUDING REGULAR
DETAIL 1 - PROPOSED REMEDIAL WORKS SECTION DETAIL TESTING OF WATER ABSORPTION. FULL REGIME TO BE AGREED SUBJECT TO IDENTIFYING
SUPPLY.

KEY LEGEND: METAL STRAPS,FRAMING ANCHORS, REINFORCED ANGLED BRACKETS AND PROPRIETARY
PRODUCTS

-MANUFACTURER: SIMPSON, OR SIMILAR APPROVED BY THE STRUCTURAL ENGINEER.


TIMBER ELEMENT TO BE MAINTAINED -PRODUCT REFERENCE: REFER TO DETAILS, OR SIMILAR APPROVED BY THE STRUCTURAL
ENGINEER.
-MATERIAL/ FINISH: MATERIAL/ FINISH: STAINLESS STEEL GRADE 304 TO BS EN 10088-2
-FASTENERS: STAINLESS STEEL
-FIXING: SECURE USING NOT LESS THAN THE NUMBER OF NAILS RECOMMENDED BY
NEW TIMBER ELEMENT ANCHOR MANUFACTURER.

POTENTIAL EXTENT OF ROT NOT VISIBLE BUT MOISTURE CONTENT > THAN 20%
BRICKWORK WALL TIMBER SPECIALIST/CONTRACTOR TO CONFIRM MOISTURE CONTENT IN TIMBER JOISTS AND
EXTENT

REPLACEMENT AND IMPLEMENTATION OF THE GUTTER STRUCTURE REQUIRED. CONNECTION


TO EXISTING DOWNPIPES TO BE CONFIRMED BY SERVICES ENGINEERS.

ALLOWANCE FOR NEW TEMPORARY DOWNPIPES TO BE MADE (CURRENTLY DOWNPIPES ARE


ALLOW FOR 2 No. SIMPSON LOCATED WITHIN THE CROSS WALLS EVERY TWO UNITS)
NEW TIMBER RAFTER
REINFORCED ANGLED BRACKETS
EPDM OR SIMILAR ISOLATING E5/2C50 OR SIMILAR FOR
CONNECTION BETWEEN BEARING 50mm
EXISTING SARKINGS OMITTED FOR CLARITY.
CONDITION TO BE ESTABLISHED ONCE ROOF SLATES ARE REMOVED.
MEMBRANE TO JOIST ENDS AT PLATE AND COMMON RAFTERS 35mm
ALL REPAIRS REPLACEMENT DETAILS ARE BASED ON LIMITED SURVEY
WALL CONNECTION INFORMATION. THE CONTRACTOR TOGETHER WITH THE TIMBER SPECIALIST IS TO
ESTABLISH THE EXTENT OF ROT BEFORE COMMENCEMENT OF ANY REPAIRS
WORKS.
50mm
35mm ANY DISCREPANCIES BETWEEN EXISTING STRUCTURE SHOWN ON DRAWING AND
REPAIRS WORKS TO VALLEY EXISTING STRUCTURE EXPOSED ON SITE TO BE BROUGHT TO THE ATTENTION OF
THE STRUCTURAL ENGINEER.
GUTTER FOR THE FUTURE USE EXISTING TIMBER COMMON RAFTER 15mm
NOTCH AT CONNECTION - MINIMUM WIDTH
SCHEME SUBJECT TO FURTHER OF TIMBER TO BE 35mm FOR SPLICE DETAIL

COORDINATION FOLLOWING SALVAGED SOUND TIMBER TO BE


DESIGN DEVELOPMENT OF RE-USED WHERE APPROPRIATE
BUYERS WALK ARCHES
DETAIL 1 - PROPOSED REMEDIAL WORKS PLAN DETAILS
DETAILS TO BE UPDATED UPON RECEIPT
OF SURVEY INFORMATION PROVIDED BY
REFER TO DRAWINGS 4525-S-HSK-EW-020 THE CONTRACTOR
SERIES FOR TEMPORARY PROPPING DETAILS

MUSEUM OF LONDON CONTRACT 2 - ROOF REPAIRS - UNITS 602 TO 606, 612 TO 614, 616 TO
ANNEXE BUILDING - FISH MARKET 617 AND 619 TO 621 - REMEDIAL WORKS DETAIL 1 - ROTTEN COMMON
PROJECT TITLE RAFTER AT CONNECTION TO MASONRY WALL

T1 23.08.2019 TENDER DO VG DATE JUN 2019 SCALE NTS CAD FILENAME STATUS
TENDER
P2 09.08.2019 TENDER DRAFT DO VG
P1 07.06.2019 FOR COMMENTS MK VG
REV DATE DESCRIPTION BY CHECKED DRAWN MK CHECKED VG PROJECT No.
4525 DRAWING No. 4525-S-HSK-EW-010F REV T1
NOTES

1 DO NOT SCALE FROM THIS DRAWING.


2 ALL DIMENSIONS ARE IN MILLIMETRES (mm) AND ALL LEVEL ARE IN METRES (m)
EXISTING TIMBER UNLESS NOTED OTHERWISE.
COMMON RAFTER 3 THIS DRAWING IS TO BE PRINTED IN COLOUR.

F
BE URT FOR FULL SECTION SIZES, REFER TO ANNOTATED SKETCHES IN THIS DOCUMENT
YO HE
TO N R
BE IN O D TH REP PRESERVATIVE TREATMENT: ORGANIC SOLVENT IMPREGNATION TO NBS SECTION Z12
CO RD E L LAC
I TEMPORARY PROP - REFER AND WOOD PROTECTION ASSOCIATION COMMODITY SPECIFICATION C8
AF NFIR ER T MIT EME 5No. M10 8.8 BOLTS
TE ME O OF NT TO DRAWINGS DESIGN SERVICE LIFE: 60 YEARS.TBC
R T D AV AN O 4525-S-HSK-EW-020 SERIES 15 FIRE RETARDANT TREATMENT: AS PER GENERAL NOTES
HE BY OID Y V F T 0
CO THE RE ISU HE FOR TEMPORARY PROPPING
ND T -IN AL TIM DETAILS 10
0 ROOF STRUCTURE
ITI IMB FEC AT BE
ON ER T TA R 10 RAFTERS ASSUMED AT 0.4m CENTRES, ASSUMED DIMENSION 150x50mm.
SU SP ION CK 0
RV EC RAFTERS ARE SUPPORTED BY THE MASONRY WALL AND A TIMBER WALLPLATE
EY IAL 10
IST 0
FOR LOADING ALLOWANCES REFER TO 4525 - GENERAL NOTES.

=
10
0

=
15 ALL ASSUMED DIMENSIONS TO BE CONFIRMED ON SITE.
0 REPAIR WORKS TO BE CARRIED OUT ONLY AFTER THE ROT AND INFESTATION SURVEY
VALLEY GUTTER DETAILS (CONDITION SURVEY), IN ORDER TO DEFINE THE EXTENT OF ROT AND TO CONFIRM THE
SUBJECT TO SURVEYS FEASIBILITY OF THESE REPAIRS.
AND INVESTIGATION ALLOW FOR 2 No. SIMPSON C

WORKS REINFORCED ANGLED NOTE THAT THE MASONRY WALLS ARE LIKELY TO REQUIRE TREATMENT TO DRY ROT AND
BRACKETS E5/2C50 OR SIMILAR A
FINISHES TO BE REMOVED TO PREVENT THE RE-INFECTION OF THE TIMBER ELEMENTS.
FOR CONNECTION BETWEEN TEMPORARY PROPPING TO SUPPORT STRUCTURE WHILST REPAIRS ARE UNDERTAKEN
NEW TIMBER COMMON RAFTER BEARING PLATE AND COMMON ARE NOT SHOWN FOR CLARITY.
APPROXIMATELY EXTENT OF
B

SIZE TO MATCH EXISTING RAFTERS CONTRACTOR TO ALLOW FOR AN ELEMENT OF ADJUSTING OF TEMPORARY WORKS TO
ROTTEN 150mm DEEP X 50mm WIDE E5/2C50
ALLOW REPAIRS TO BE CARRIED OUT.
COMMON RAFTERS ADDITIONAL TIME FRAME IN THE PROGRAMME AND CONTINGENCY IN THE COST PLAN TO
RESPOND TO EXPOSED POTENTIAL DEFECTS IN THE EXISTING STRUCTURE AND THE
EXISTING STRUCTURE BEING DIFFERENT THAN ASSUMED AND SHOWN ON THIS DRAWING.

SPECIFICATION FOR CONCRETE PADSTONES

-COMPRESSIVE STRENGTH CLASS (CYLINDER/ CUBE MINIMUM): C25/30


-TARGET DENSITY (OVEN-DRY): NORMAL.
WALL STRAPS TO BE -FIBRES: NOT REQUIRED.
PROVIDED AT ALTERNATE ALLOW FOR LES OR L-STRAPS -AGGREGATE SIZE (MAXIMUM): 20MM TYPE/ DENSITY: NORMAL WEIGHT.
JOIST LOCATION TO WALL PLATE AAND MASONRY. -COARSE RECYCLED AGGREGATES: RA NOT PERMITTED, RCA OF LOCAL SUPPLY WITHIN
SPACING AT 400 mm ALTERNATE 30KM OF SITE TO BS8500-2-2006 TABLE 2 AND 3, MASS FRACTION NOT EXCEEDING 20% OF
TO TIMBER RAFTERS COARSE AGGREGATES PERMISSIBLE.
TEMPORARY LATERAL PROPS TO BE PROVIDED -ADDITIONAL AGGREGATE REQUIREMENTS: ALL AGGREGATES TO CONFORM TO BS EN
FOR OVERALL STRUCTURAL STABILITY. REFER TO 12620.
DRAWINGS 4525-S-HSK-EW-020 SERIES FOR -DESIGN CHEMICAL CLASS: CLASS DS-1 TO DS-3 AND ACEC AC-1 TO AC-3 OF TABLE C2 OF
TEMPORARY PROPPING DETAILS BRE SPECIAL DIGEST 1 PART C (2005). ENVIRONMENTAL CLASS: XC1
LIMITING VALUES FOR COMPOSITION:
-WATER:CEMENT RATIO (MAXIMUM): AS DC CLASS.
-CEMENT/ COMBINATION CONTENT (MINIMUM): AS PER ENVIRONMENTAL CLASS.
FULL REPLACEMENT OF FIRST THREE COURSES.
DETAIL 2 ROTTEN COMMON RAFTER AT CONNECTION TO
-CEMENT/ COMBINATION CONTENT (MAXIMUM): AS PER ENVIRONMENTAL CLASS.
NEW BRICKS TO BE CROSS BONDED TO EXISTING. -AIR CONTENT IN SITU (MINIMUM): NO REQUIREMENT.
BRICKS AND MORTAR TO MATCH EXISTING.
MASONRY WALL - ASSUMED
-CONSISTENCE CLASS: CONTRACTOR’S CHOICE.
EXISTING MASONRY
-PERMITTED CEMENT/ COMBINATIONS: AS PER ENVIRONMENTAL CLASS.
WALL
-CHLORIDE CLASS: BIP 2001: GENERALLY CL 0.40.
-COLOUR: NOT REQUIRED.
-ADDITIONAL MIX REQUIREMENTS: WHERE SECONDARY AGGREGATES ARE USED WITH
APPROVAL ADDITIONAL AGGREGATE TESTING WILL BE REQUIRED INCLUDING REGULAR
TESTING OF WATER ABSORPTION. FULL REGIME TO BE AGREED SUBJECT TO IDENTIFYING

DETAIL 2 - PROPOSED REMEDIAL WORKS SECTION DETAIL


SUPPLY.

KEY LEGEND: METAL STRAPS,FRAMING ANCHORS, REINFORCED ANGLED BRACKETS AND PROPRIETARY
PRODUCTS

-MANUFACTURER: SIMPSON, OR SIMILAR APPROVED BY THE STRUCTURAL ENGINEER.


TIMBER ELEMENT TO BE MAINTAINED -PRODUCT REFERENCE: REFER TO DETAILS, OR SIMILAR APPROVED BY THE STRUCTURAL
ENGINEER.
-MATERIAL/ FINISH: MATERIAL/ FINISH: STAINLESS STEEL GRADE 304 TO BS EN 10088-2
-FASTENERS: STAINLESS STEEL
-FIXING: SECURE USING NOT LESS THAN THE NUMBER OF NAILS RECOMMENDED BY
NEW TIMBER ELEMENT ANCHOR MANUFACTURER.
ALLOW FOR 2 No. SIMPSON REINFORCED ANGLED
BRACKETS E5/2C50 OR SIMILAR FOR CONNECTION
BETWEEN BEARING PLATE AND COMMON RAFTERS POTENTIAL EXTENT OF ROT NOT VISIBLE BUT MOISTURE CONTENT > THAN 20%
BRICKWORK WALL TIMBER SPECIALIST/CONTRACTOR TO CONFIRM MOISTURE CONTENT IN TIMBER JOISTS AND
EXTENT

REPLACEMENT AND IMPLEMENTATION OF THE GUTTER STRUCTURE REQUIRED. CONNECTION


TO EXISTING DOWNPIPES TO BE CONFIRMED BY SERVICES ENGINEERS.

ALLOWANCE FOR NEW TEMPORARY DOWNPIPES TO BE MADE (CURRENTLY DOWNPIPES ARE


LOCATED WITHIN THE CROSS WALLS EVERY TWO UNITS)

EPDM OR SIMILAR ISOLATING NEW TIMBER RAFTER


EXISTING SARKINGS OMITTED FOR CLARITY.
CONDITION TO BE ESTABLISHED ONCE ROOF SLATES ARE REMOVED.
MEMBRANE TO JOIST ENDS AT ALL REPAIRS REPLACEMENT DETAILS ARE BASED ON LIMITED SURVEY
WALL CONNECTION 50mm 35mm INFORMATION. THE CONTRACTOR TOGETHER WITH THE TIMBER SPECIALIST IS TO
ESTABLISH THE EXTENT OF ROT BEFORE COMMENCEMENT OF ANY REPAIRS
WORKS.

ANY DISCREPANCIES BETWEEN EXISTING STRUCTURE SHOWN ON DRAWING AND


REPAIRS WORKS TO VALLEY 50mm
EXISTING STRUCTURE EXPOSED ON SITE TO BE BROUGHT TO THE ATTENTION OF
THE STRUCTURAL ENGINEER.
GUTTER FOR THE FUTURE USE 35mm

SCHEME SUBJECT TO FURTHER


COORDINATION FOLLOWING
EXISTING TIMBER COMMON RAFTER 15mm
NOTCH AT CONNECTION - MINIMUM WIDTH SALVAGED SOUND TIMBER TO BE
DESIGN DEVELOPMENT OF
OF TIMBER TO BE 35mm
RE-USED WHERE APPROPRIATE
BUYERS WALK ARCHES

DETAILS TO BE UPDATED UPON RECEIPT


DETAIL 2 - PROPOSED REMEDIAL WORKS PLAN DETAILS OF SURVEY INFORMATION PROVIDED BY
REFER TO DRAWINGS 4525-S-HSK-EW-020 THE CONTRACTOR
SERIES FOR TEMPORARY PROPPING DETAILS

MUSEUM OF LONDON CONTRACT 2 - ROOF REPAIRS - UNITS 602 TO 606, 612 TO 614, 616 TO
ANNEXE BUILDING - FISH MARKET 617 AND 619 TO 621 - REMEDIAL WORKS DETAIL 2 - ROTTEN COMMON
PROJECT TITLE RAFTER AT CONNECTION TO MASONRY WALL

T1 23.08.2019 TENDER DO VG DATE JUN 2019 SCALE NTS CAD FILENAME STATUS
TENDER
P2 09.08.2019 TENDER DRAFT DO VG
P1 07.06.2019 FOR COMMENTS MK VG
REV DATE DESCRIPTION BY CHECKED DRAWN MK CHECKED VG PROJECT No.
4525 DRAWING No. 4525-S-HSK-EW-010G REV T1
NOTES
INSPECTION OF EXISTING CONNECTION REFER TO DRAWINGS 4525-S-HSK-EW-020 1 DO NOT SCALE FROM THIS DRAWING.
REQUIRED TO ASSESS CONDITION OF SERIES FOR TEMPORARY PROPPING DETAILS 2 ALL DIMENSIONS ARE IN MILLIMETRES (mm) AND ALL LEVEL ARE IN METRES (m)
UNLESS NOTED OTHERWISE.
TIMBER AND NAILS 3 THIS DRAWING IS TO BE PRINTED IN COLOUR.

FOR FULL SECTION SIZES, REFER TO ANNOTATED SKETCHES IN THIS DOCUMENT

PRESERVATIVE TREATMENT: ORGANIC SOLVENT IMPREGNATION TO NBS SECTION Z12


AND WOOD PROTECTION ASSOCIATION COMMODITY SPECIFICATION C8
DESIGN SERVICE LIFE: 60 YEARS.TBC
FIRE RETARDANT TREATMENT: AS PER GENERAL NOTES

EXISTING RUSTED NAILS ROOF STRUCTURE


RAFTERS ASSUMED AT 0.4m CENTRES, ASSUMED DIMENSION 150x50mm.
RAFTERS ARE SUPPORTED BY THE MASONRY WALL AND A TIMBER WALLPLATE

FOR LOADING ALLOWANCES REFER TO 4525 - GENERAL NOTES.

ALL ASSUMED DIMENSIONS TO BE CONFIRMED ON SITE.


REPAIR WORKS TO BE CARRIED OUT ONLY AFTER THE ROT AND INFESTATION SURVEY
EXISTING TIMBER RAFTER (CONDITION SURVEY), IN ORDER TO DEFINE THE EXTENT OF ROT AND TO CONFIRM THE
KEY LEGEND: FEASIBILITY OF THESE REPAIRS.

NOTE THAT THE MASONRY WALLS ARE LIKELY TO REQUIRE TREATMENT TO DRY ROT AND
FINISHES TO BE REMOVED TO PREVENT THE RE-INFECTION OF THE TIMBER ELEMENTS.
TEMPORARY PROPPING TO SUPPORT STRUCTURE WHILST REPAIRS ARE UNDERTAKEN
TIMBER ELEMENT TO BE MAINTAINED ARE NOT SHOWN FOR CLARITY.
CONTRACTOR TO ALLOW FOR AN ELEMENT OF ADJUSTING OF TEMPORARY WORKS TO
ALLOW REPAIRS TO BE CARRIED OUT.
ADDITIONAL TIME FRAME IN THE PROGRAMME AND CONTINGENCY IN THE COST PLAN TO
EXISTING TIMBER COLLAR TIE NEW TIMBER ELEMENT RESPOND TO EXPOSED POTENTIAL DEFECTS IN THE EXISTING STRUCTURE AND THE
EXISTING STRUCTURE BEING DIFFERENT THAN ASSUMED AND SHOWN ON THIS DRAWING.

SPECIFICATION FOR CONCRETE PADSTONES

-COMPRESSIVE STRENGTH CLASS (CYLINDER/ CUBE MINIMUM): C25/30


-TARGET DENSITY (OVEN-DRY): NORMAL.
-FIBRES: NOT REQUIRED.
-AGGREGATE SIZE (MAXIMUM): 20MM TYPE/ DENSITY: NORMAL WEIGHT.
-COARSE RECYCLED AGGREGATES: RA NOT PERMITTED, RCA OF LOCAL SUPPLY WITHIN
30KM OF SITE TO BS8500-2-2006 TABLE 2 AND 3, MASS FRACTION NOT EXCEEDING 20% OF
COARSE AGGREGATES PERMISSIBLE.
-ADDITIONAL AGGREGATE REQUIREMENTS: ALL AGGREGATES TO CONFORM TO BS EN
12620.
-DESIGN CHEMICAL CLASS: CLASS DS-1 TO DS-3 AND ACEC AC-1 TO AC-3 OF TABLE C2 OF
BRE SPECIAL DIGEST 1 PART C (2005). ENVIRONMENTAL CLASS: XC1
LIMITING VALUES FOR COMPOSITION:
-WATER:CEMENT RATIO (MAXIMUM): AS DC CLASS.
DETAIL 3 ROTTEN COMMON RAFTER AT CONNECTION TO COLLAR TIE - ASSUMED -CEMENT/ COMBINATION CONTENT (MINIMUM): AS PER ENVIRONMENTAL CLASS.
-CEMENT/ COMBINATION CONTENT (MAXIMUM): AS PER ENVIRONMENTAL CLASS.
-AIR CONTENT IN SITU (MINIMUM): NO REQUIREMENT.
-CONSISTENCE CLASS: CONTRACTOR’S CHOICE.
-PERMITTED CEMENT/ COMBINATIONS: AS PER ENVIRONMENTAL CLASS.
-CHLORIDE CLASS: BIP 2001: GENERALLY CL 0.40.
-COLOUR: NOT REQUIRED.
-ADDITIONAL MIX REQUIREMENTS: WHERE SECONDARY AGGREGATES ARE USED WITH
APPROVAL ADDITIONAL AGGREGATE TESTING WILL BE REQUIRED INCLUDING REGULAR
TESTING OF WATER ABSORPTION. FULL REGIME TO BE AGREED SUBJECT TO IDENTIFYING
SUPPLY.

METAL STRAPS,FRAMING ANCHORS, REINFORCED ANGLED BRACKETS AND PROPRIETARY


ALLOW FOR 2 No. SIMPSON REINFORCED ALLOW FOR 2 No. SIMPSON REINFORCED PRODUCTS
ANGLED BRACKETS E5/2C50 OR SIMILAR ANGLED BRACKETS E5/2C50 OR SIMILAR
FOR CONNECTION BETWEEN BEARING FOR CONNECTION BETWEEN BEARING -MANUFACTURER: SIMPSON, OR SIMILAR APPROVED BY THE STRUCTURAL ENGINEER.
PLATE AND COMMON RAFTERS PLATE AND COMMON RAFTERS -PRODUCT REFERENCE: REFER TO DETAILS, OR SIMILAR APPROVED BY THE STRUCTURAL
ENGINEER.
-MATERIAL/ FINISH: MATERIAL/ FINISH: STAINLESS STEEL GRADE 304 TO BS EN 10088-2
-FASTENERS: STAINLESS STEEL
-FIXING: SECURE USING NOT LESS THAN THE NUMBER OF NAILS RECOMMENDED BY
ANCHOR MANUFACTURER.

EXISTING TIMBER RAFTER NEW TIMBER RAFTER


POTENTIAL EXTENT OF ROT NOT VISIBLE BUT MOISTURE CONTENT > THAN 20%
TIMBER SPECIALIST/CONTRACTOR TO CONFIRM MOISTURE CONTENT IN TIMBER JOISTS AND
EXTENT

REPLACEMENT AND IMPLEMENTATION OF THE GUTTER STRUCTURE REQUIRED. CONNECTION


TO EXISTING DOWNPIPES TO BE CONFIRMED BY SERVICES ENGINEERS.

ALLOWANCE FOR NEW TEMPORARY DOWNPIPES TO BE MADE (CURRENTLY DOWNPIPES ARE


LOCATED WITHIN THE CROSS WALLS EVERY TWO UNITS)

EXISTING TIMBER RAFTER EXISTING TIMBER RAFTER EXISTING SARKINGS OMITTED FOR CLARITY.
CONDITION TO BE ESTABLISHED ONCE ROOF SLATES ARE REMOVED.
2No. M12 GRADE 8.8 BOLTS 2No. M12 GRADE 8.8 BOLTS
ALL REPAIRS REPLACEMENT DETAILS ARE BASED ON LIMITED SURVEY
INFORMATION. THE CONTRACTOR TOGETHER WITH THE TIMBER SPECIALIST IS TO
ESTABLISH THE EXTENT OF ROT BEFORE COMMENCEMENT OF ANY REPAIRS
WORKS.

ANY DISCREPANCIES BETWEEN EXISTING STRUCTURE SHOWN ON DRAWING AND


EXISTING STRUCTURE EXPOSED ON SITE TO BE BROUGHT TO THE ATTENTION OF
THE STRUCTURAL ENGINEER.

DETAIL 3 - PROPOSED REMEDIAL WORKS SECTION DETAIL DETAIL 3 - PROPOSED REMEDIAL WORKS SECTION DETAIL
(SCENARIO 1 - EXISTING RAFTER AND COLLAR TIE) (SCENARIO 2 - NEW RAFTER AND COLLAR TIE) SALVAGED SOUND TIMBER TO BE
RE-USED WHERE APPROPRIATE

DETAILS TO BE UPDATED UPON RECEIPT


OF SURVEY INFORMATION PROVIDED BY
THE CONTRACTOR

MUSEUM OF LONDON CONTRACT 2 - ROOF REPAIRS - UNITS 602 TO 606, 612 TO 614, 616 TO
ANNEXE BUILDING - FISH MARKET 617 AND 619 TO 621 - REMEDIAL WORKS DETAIL 3 - ROTTEN COMMON
PROJECT TITLE RAFTER AT CONNECTION TO COLLAR TIE

T1 23.08.2019 TENDER DO VG DATE JUN 2019 SCALE NTS CAD FILENAME STATUS
TENDER
P2 09.08.2019 TENDER DRAFT DO VG
P1 07.06.2019 FOR COMMENTS MK VG
REV DATE DESCRIPTION BY CHECKED DRAWN MK CHECKED VG PROJECT No.
4525 DRAWING No. 4525-S-HSK-EW-010H REV T1
NOTES
REFER TO DRAWINGS 4525-S-HSK-EW-020 1 DO NOT SCALE FROM THIS DRAWING.
SERIES FOR TEMPORARY PROPPING DETAILS 2 ALL DIMENSIONS ARE IN MILLIMETRES (mm) AND ALL LEVEL ARE IN METRES (m)
UNLESS NOTED OTHERWISE.
3 THIS DRAWING IS TO BE PRINTED IN COLOUR.

FOR FULL SECTION SIZES, REFER TO ANNOTATED SKETCHES IN THIS DOCUMENT

PRESERVATIVE TREATMENT: ORGANIC SOLVENT IMPREGNATION TO NBS SECTION Z12


AND WOOD PROTECTION ASSOCIATION COMMODITY SPECIFICATION C8
DESIGN SERVICE LIFE: 60 YEARS.TBC
TYPICAL:
FIRE RETARDANT TREATMENT: AS PER GENERAL NOTES
ALLOW FOR SPR TIMBER
JOIST HANGER SLOPE
ROOF STRUCTURE
ADJUSTABLE

MPANY INC.
RAFTERS ASSUMED AT 0.4m CENTRES, ASSUMED DIMENSION 150x50mm.
RAFTERS ARE SUPPORTED BY THE MASONRY WALL AND A TIMBER WALLPLATE
COMMON RAFTERS AT 400 mm
COMMON RAFTERS AT 400 mm CENTRES CENTRES - CONDITION UNKNOWN. FOR LOADING ALLOWANCES REFER TO 4525 - GENERAL NOTES.
- CONDITION UNKNOWN. ASSUME ASSUME SPLICE DETAIL AS PER
SPLICE DETAIL AS PER DETAIL 1 DETAIL 2 ALL ASSUMED DIMENSIONS TO BE CONFIRMED ON SITE.
REPAIR WORKS TO BE CARRIED OUT ONLY AFTER THE ROT AND INFESTATION SURVEY
(CONDITION SURVEY), IN ORDER TO DEFINE THE EXTENT OF ROT AND TO CONFIRM THE
FEASIBILITY OF THESE REPAIRS.

NOTE THAT THE MASONRY WALLS ARE LIKELY TO REQUIRE TREATMENT TO DRY ROT AND
FINISHES TO BE REMOVED TO PREVENT THE RE-INFECTION OF THE TIMBER ELEMENTS.
ALLOW FOR STRAPS AT TEMPORARY PROPPING TO SUPPORT STRUCTURE WHILST REPAIRS ARE UNDERTAKEN
ALTERNATE LOCATION ARE NOT SHOWN FOR CLARITY.
BETWEEN COMMON RAFTERS CONTRACTOR TO ALLOW FOR AN ELEMENT OF ADJUSTING OF TEMPORARY WORKS TO
ALLOW REPAIRS TO BE CARRIED OUT.
ADDITIONAL TIME FRAME IN THE PROGRAMME AND CONTINGENCY IN THE COST PLAN TO
RESPOND TO EXPOSED POTENTIAL DEFECTS IN THE EXISTING STRUCTURE AND THE
EXISTING STRUCTURE BEING DIFFERENT THAN ASSUMED AND SHOWN ON THIS DRAWING.

SPECIFICATION FOR CONCRETE PADSTONES

-COMPRESSIVE STRENGTH CLASS (CYLINDER/ CUBE MINIMUM): C25/30


-TARGET DENSITY (OVEN-DRY): NORMAL.
-FIBRES: NOT REQUIRED.
-AGGREGATE SIZE (MAXIMUM): 20MM TYPE/ DENSITY: NORMAL WEIGHT.
DETAIL 4: ENHANCEMENT OF EXISTING CONNECTION BETWEEN -COARSE RECYCLED AGGREGATES: RA NOT PERMITTED, RCA OF LOCAL SUPPLY WITHIN
30KM OF SITE TO BS8500-2-2006 TABLE 2 AND 3, MASS FRACTION NOT EXCEEDING 20% OF
COMMON RAFTERS AND TOP MEMBER COARSE AGGREGATES PERMISSIBLE.
-ADDITIONAL AGGREGATE REQUIREMENTS: ALL AGGREGATES TO CONFORM TO BS EN
12620.
-DESIGN CHEMICAL CLASS: CLASS DS-1 TO DS-3 AND ACEC AC-1 TO AC-3 OF TABLE C2 OF
BRE SPECIAL DIGEST 1 PART C (2005). ENVIRONMENTAL CLASS: XC1
LIMITING VALUES FOR COMPOSITION:
-WATER:CEMENT RATIO (MAXIMUM): AS DC CLASS.
-CEMENT/ COMBINATION CONTENT (MINIMUM): AS PER ENVIRONMENTAL CLASS.
-CEMENT/ COMBINATION CONTENT (MAXIMUM): AS PER ENVIRONMENTAL CLASS.
DETAIL 4 SHOWN, ASSUME -AIR CONTENT IN SITU (MINIMUM): NO REQUIREMENT.
-CONSISTENCE CLASS: CONTRACTOR’S CHOICE.
DRY LINING IN FUTURE USE -PERMITTED CEMENT/ COMBINATIONS: AS PER ENVIRONMENTAL CLASS.
-CHLORIDE CLASS: BIP 2001: GENERALLY CL 0.40.
SCHEME -COLOUR: NOT REQUIRED.
-ADDITIONAL MIX REQUIREMENTS: WHERE SECONDARY AGGREGATES ARE USED WITH
APPROVAL ADDITIONAL AGGREGATE TESTING WILL BE REQUIRED INCLUDING REGULAR
TESTING OF WATER ABSORPTION. FULL REGIME TO BE AGREED SUBJECT TO IDENTIFYING
SUPPLY.

METAL STRAPS,FRAMING ANCHORS, REINFORCED ANGLED BRACKETS AND PROPRIETARY


PRODUCTS

-MANUFACTURER: SIMPSON, OR SIMILAR APPROVED BY THE STRUCTURAL ENGINEER.


-PRODUCT REFERENCE: REFER TO DETAILS, OR SIMILAR APPROVED BY THE STRUCTURAL
ENGINEER.
-MATERIAL/ FINISH: MATERIAL/ FINISH: STAINLESS STEEL GRADE 304 TO BS EN 10088-2
-FASTENERS: STAINLESS STEEL
-FIXING: SECURE USING NOT LESS THAN THE NUMBER OF NAILS RECOMMENDED BY
ANCHOR MANUFACTURER.

POTENTIAL EXTENT OF ROT NOT VISIBLE BUT MOISTURE CONTENT > THAN 20%
TIMBER SPECIALIST/CONTRACTOR TO CONFIRM MOISTURE CONTENT IN TIMBER JOISTS AND
EXTENT

REPLACEMENT AND IMPLEMENTATION OF THE GUTTER STRUCTURE REQUIRED. CONNECTION


TO EXISTING DOWNPIPES TO BE CONFIRMED BY SERVICES ENGINEERS.

ALLOWANCE FOR NEW TEMPORARY DOWNPIPES TO BE MADE (CURRENTLY DOWNPIPES ARE


LOCATED WITHIN THE CROSS WALLS EVERY TWO UNITS)

EXISTING SARKINGS OMITTED FOR CLARITY.


CONDITION TO BE ESTABLISHED ONCE ROOF SLATES ARE REMOVED.

ALL REPAIRS REPLACEMENT DETAILS ARE BASED ON LIMITED SURVEY


INFORMATION. THE CONTRACTOR TOGETHER WITH THE TIMBER SPECIALIST IS TO
ESTABLISH THE EXTENT OF ROT BEFORE COMMENCEMENT OF ANY REPAIRS
WORKS.

ANY DISCREPANCIES BETWEEN EXISTING STRUCTURE SHOWN ON DRAWING AND


EXISTING STRUCTURE EXPOSED ON SITE TO BE BROUGHT TO THE ATTENTION OF
THE STRUCTURAL ENGINEER.

SALVAGED SOUND TIMBER TO BE


RE-USED WHERE APPROPRIATE

DETAILS TO BE UPDATED UPON RECEIPT


OF SURVEY INFORMATION PROVIDED BY
THE CONTRACTOR

MUSEUM OF LONDON CONTRACT 2 - ROOF REPAIRS - UNITS 602 TO 606, 612 TO 614, 616 TO
ANNEXE BUILDING - FISH MARKET 617 AND 619 TO 621 - DETAIL 4 - ENHANCEMENT OF EXISTING
PROJECT TITLE CONNECTION BETWEEN COMMON RAFTERS AND TOP MEMBER

T1 23.08.2019 TENDER DO VG DATE JUN 2019 SCALE NTS CAD FILENAME STATUS
TENDER
P2 09.08.2019 TENDER DRAFT DO VG
P1 07.06.2019 FOR COMMENTS MK VG
REV DATE DESCRIPTION BY CHECKED DRAWN MK CHECKED VG PROJECT No.
4525 DRAWING No. 4525-S-HSK-EW-010I REV T1

You might also like