0% found this document useful (0 votes)
42 views

DB String Monitoring Unit 2422 en

The String Monitoring Unit (SMU 2422) monitors up to 24 DC current inputs and 1 DC voltage input from 0-1500V to identify defects in photovoltaic (PV) systems. It measures string currents, temperature, has 4 digital and 2 analog inputs, and communicates via RS485 and Modbus RTU protocol. Setup includes setting the Modbus address via DIP switches and selecting baud rate, protocol, and parity via software.

Uploaded by

risqi rotbi
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
42 views

DB String Monitoring Unit 2422 en

The String Monitoring Unit (SMU 2422) monitors up to 24 DC current inputs and 1 DC voltage input from 0-1500V to identify defects in photovoltaic (PV) systems. It measures string currents, temperature, has 4 digital and 2 analog inputs, and communicates via RS485 and Modbus RTU protocol. Setup includes setting the Modbus address via DIP switches and selecting baud rate, protocol, and parity via software.

Uploaded by

risqi rotbi
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

STRING MONITORING

UNIT 2422 (SMU 2422)


Item No.: 421.928 Picture may differ from original product

DESCRIPTION OF FUNCTIONS The String Monitoring Unit was specially developed for multiple channel measurement of string
currents in PV systems. Regardless of the inverter used, the measurement unit monitors the
DC voltage sided strings of PV systems and enables quick identification of defects and
troubleshooting.

TECHNICAL DATA
Input current: Number: 24
Measuring range: 0 … 22 A DC
Precision: ≤ 0.5 %

Input voltage: Number: 1


Measuring range: 0 … 1,500 V DC
Precision: < 1.5 %

Input temperature: Number: 1


Type: PT100 as 3-wire circuit
Measuring range: 0 … 300 °C
Precision: < 1.5 %

Digital input: Number: 4


Type: PNP digital input, 24 V DC
Maximum input current: 24 V DC

Analog current input: Number: 1


Type: Current input
Measuring range: 0 … 20 mA
Precision: < 1.5 %

Analog voltage input: Number: 1


Type: Voltage input
Measuring range: 0 … 10 V

Supply: Supply voltage: 22 … 27 V DC


Power consumption: <3W

Communication interface: Standard: RS485


Data format: 8N1 (factory setting), 8E1, 8O1
Adjustable via Modbus
Protocols: Modbus RTU
Baud rate: 2.400 bps, 4.800 bps, 9.600 bps(factory setting), 19.200 bps
Bus address: Defined by DIP-switches

Information subject to change, errors and omissions excepted / As at 05-2016 1|2


Ambient conditions: Operating temperature: -20 °C … +80 °C
Working atmosphere: Without corrosive gas

Housing: Dimensions (W x H x D): 326 x 108 x 52 mm


Type of installation: DIN EN mounting rail
Weight: 880 g

SETTING OF MODBUS ADDRESS

Protocol = Modbus
Parity = none
Baud rate = 19200
Address = 2

Protocol = Modbus
Parity = none
Baud rate = 9600
Address = 55

meteocontrol GmbH | Spicherer Straße 48 | 86157 Augsburg | Germany | Telephone +49 (0)821 34666 - 0 | Fax +49 (0)821 34666 - 11
E-Mail [email protected] | Web www.meteocontrol.com

Information subject to change, errors and omissions excepted / As at 05-2016 2|2