HLG 600 R Spec Report

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Report No: L072011001P

8165 E Kaiser Blvd. Anaheim, CA 92808


www.lightlaboratory.com

Report No: L072011001P Issue Date: 7/22/2020

Report Prepared For: Horticulture Lighting Group


752 North State St, #208, Westerville, OH 43082

Model Number: HLG 600 Rspec

Test: Photosynthetically active radiation (PAR) & Electrical measurement

Standards Used: Appropriate part or all test guidelines were used for test performed:
IESNA LM79: 2008 Approved Methods for Electrical and Photometric Measurements of Solid-State Lighting Products
ANSI NEMA ANSLG C78.377: 2008 Specification of the Chromaticity of Solid State Lighting Products
ANSI C82.77:2002: Harmonic Emission Limits-Related Quality Requirements for Lighting Equipment

Description of Sample: Client submitted the sample. Received in working and undamaged condition. No
modifications were necessary.

Special Test Condition: Fixture is tested with no special conditions.

Sample Arrival Date: 7/17/20

Date of Tests: 7/17/20 - 7/22/20

Seasoning of Sample: No seasoning was performed in accordance with IESNA LM-79.

Equipment List
Equipment Used Model No Stock No Calibration Due Date
Chroma Programmable AC Source 61604 PS-AC02 --
Yokogawa Digital Power Meter WT210 MT-EL06-S4 1/9/21
BK PRECISION 1747 PS-DC04 1/10/21
Fluke Digital Thermometer 52K/J MT-TP05 1/10/21
LLI Type C Goniophotometer System RMG-C-MKII CD-LL04-GC --
LLI 2M Sphere 2MR97 CD-SN03-S2 --
LLI Spectroradiometer SPR-3000 MT-SC01-S2 Before Use

Page 1 of 4
Report No: L072011001P

8165 E Kaiser Blvd. Anaheim, CA 92808


www.lightlaboratory.com

General Information
Manufacturer: Horticulture Lighting Group
Model Number: HLG 600 Rspec
Driver Model Number: INVENTRONICS EUD-600S280DT

Photometric, PPF & Electrical Test Results


Total PPF (µmol/s): 1521.98 * 380 - 780nm range
Total PPF (µmol/s): 1479.48 * 400 - 700nm range
Total Radiant Flux(W): 313.55 * 380 - 780nm range
Total Lumens (lm): 93787.55 * 380 - 780nm range
PPF Efficacy (µmol/Joule): 2.55 * 380 - 780nm range
PPF Efficacy (µmol/Joule): 2.48 * 400 - 700nm range
Luminous Efficacy (lm/W): 157.15
Input Voltage (VAC/60Hz): 220.09
Input Current (Amp): 2.7183
Input Power (W): 596.80
Input Power Factor: 0.9976
Current ATHD (%): 4.3%

Test Condition
Ambient Temperature (oC): 25.0
Stabilization Time (Hours): 1:30
Total Operating Time (Hours): 2:30

FIG. 1 LUMINAIRE

Page 2 of 4
Report No: L072011001P

8165 E Kaiser Blvd. Anaheim, CA 92808


www.lightlaboratory.com

Colorimetry Test Results

Spectral Power Distribution


1.0
0.9
0.8
Nomalized Power

0.7
0.6
0.5
0.4
0.3
0.2
0.1
0.0
380 400 420 440 460 480 500 520 540 560 580 600 620 640 660 680 700 720 740 760 780
Wavelength(nm)

CRI & CCT


x 0.4142 CIE 1931 Chromaticity Diagram
0.9
Y
y 0.3834
u' 0.2446 520
v' 0.5095 0.8 530

CRI 89.40 510 540

CCT 3248 0.7 550


Duv -0.00502
R Values 0.6
560

R1 88.78 570
500
R2 94.81
0.5
R3 96.70 580

R4 87.79 590

R5 89.48 0.4
600
R6 92.58 0.4142, 0.3834 610
620
R7 88.51 0.3 490 630
640
650
R8 76.22 700

R9 48.22 0.2
R10 88.25
480
R11 88.00 0.1
R12 78.65 470
460
R13 90.47 440
0 430
X
R14 98.64 0 0.1
380
0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
R15 85.86

Page 3 of 4
Report No: L072011001P

8165 E Kaiser Blvd. Anaheim, CA 92808


www.lightlaboratory.com

Test Methods
Spectral Measurements - Integrating Sphere
A Sensing Spectroradiometer SPR-3000, in conjunction with Light Laboratory 2 meter integrating sphere was used to
measure chromaticity coordinates, correlated color temperature(CCT) and the color rendering index(CRI) for each
sample.

Ambient temperature is set to 25oC and is measured from the center of the fixture, within 1ft from the outside of the
fixture. Temperature is maintained at 25oC throughout the testing process and the sample is stabilized for at least 30mins
and longer as necessary for the sample to achieve stabilization.

Electrical measurements are measured using the listed equipment.

Disclaimers:
This report must not be used by the customer to claim product certification, approval or endorsement by NVLAP, NIST or
any agency of Federal Government.

Report Prepared by : Keyur Patel

Test Report Reviewed by:

Steve Kang
Quality Assurance

Page 4 of 4