CONTROL VALVE SIZING CALCULATIONS for Natural Gas

MAXIMUM FLOW M3/HR 2000


SP. GRAVITY Air = 1 0.7
TEMPERATURE Deg C 70
Inlet PRESSURE Kg/cm2 16
Outlet PRESSURE Kg/cm2 15
.
18.77704 Cv = 18.777
7.306083

CONTROL VALVE SIZE = 2"