Service Manual
Models: GWH09YD-S6DBA2A
GWH12YD-S6DBA2A
(Refrigerant:R32)
Table of Contents
Table of Contents
Service Manual
9. Maintenance.............................................................................................................51
9.1 Error Code List................................................................................................................51
9.2 Procedure of Troubleshooting.........................................................................................58
9.3 Maintenance Method for Normal Malfunction..................................................................73
10. Exploded View and Parts List...............................................................75
10.1 Indoor Unit.....................................................................................................................75
10.2 Outdoor Unit..................................................................................................................78
11. Removal Procedure........................................................................................80
11.1 Removal Procedure of Indoor Unit................................................................................80
11.2 Removal Procedure of Outdoor Unit.............................................................................85
Appendix:.........................................................................................................................91
Appendix 1: Reference Sheet of Celsius and Fahrenheit.....................................................91
Appendix 2: Configuration of Connection Pipe......................................................................91
Appendix 3: Pipe Expanding Method....................................................................................92
Appendix 4: List of Resistance for Temperature Sensor.......................................................93
Table of Contents
Service Manual
GWH09YD-S6DBA2A/I
GWH12YD-S6DBA2A/I
Outdoor Unit:
GWH09YD-S6DBA2A/O
GWH12YD-S6DBA2A/O
Remote Controller:
YAG1FB YAG1FB3(WiFi)
FAN
- +
MODE
ON/OFF
Technical Information 1
Service Manual
2. Specifications
2.1 Specification Sheet
2 Technical Information
Service Manual
The above data is subject to change without notice; please refer to the nameplate of the unit.
Technical Information 3
Service Manual
14 14
12 12
10 10
Current(A)
Current(A)
8 8
6 6
4 4 Condition
Condition
Indoor:DB 20°C
Indoor:DB27°C WB19°C
2 2 Indoor air flow: Super High
Indoor air flow: Super High
Pipe length:5m
Pipe length:5m
0 0
0 20 40 60 80 100 120 0 20 40 60 80 100 120
Cooling Heating
110
120
100
110
100
90
Capacity ratio(%)
90
Capacity ratio(%)
80 80
70
70 Condition
60 Indoor:DB 20°C
Condition Indoor air flow:Super High
Indoor:DB 27°C WB19°C 50 Pipe length:5m
60 Indoor air flow: Super High
Pipe length:5m 40
-30 -4 5 17.6 32 44.6 50
50
21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 Outdoor temp(°C)
4 Technical Information
Service Manual
Heating:
Rated heating Pressure of gas pipe Inlet and outlet pipe
condition(°C) connecting indoor and temperature of heat Fan speed of Fan speed of
Model
(DB/WB) outdoor unit exchanger indoor unit outdoor unit
Indoor Outdoor P (MPa) T1 (°C) T2 (°C)
20/- 7/6 9K 2.8 to 3.0 70 to 35 2 to 4 Super High High
20/- 7/6 12K 2.8 to 3.0 70 to 35 2 to 4 Super High High
Instruction:
T1: Inlet and outlet pipe temperature of evaporator
T2: Inlet and outlet pipe temperature of condenser
P: Pressure at the side of big valve
Connection pipe length: 5m.
60 60
12K 58
50 Heating
Noise dB(A)
56
Noise dB(A)
40 54
Cooling
52
30 50
9K 48
20
46
20 30 40 50 60 70 80 90 100
10
Super Middle Middle Super Compressor frequency(Hz)
High High High Middle Low Low Low
Technical Information 5
Service Manual
W D
H
117 685 194
Φ55 Φ55
38 38
190 140
Unit:mm
Model W H D
09K/12K 996 301 225
6 Technical Information
Service Manual
838 303
596
899 378
550
Unit:mm
354
Technical Information 7
Service Manual
5HIULJHUDQW6\VWHP'LDJUDP
INDOOR UNIT OUTDOOR UNIT
GAS SIDE
3-WAY VALVE
4-Way valve
Discharge
HEAT
EXCHANGE
(EVAPORATOR) Suction Accumlator
COMPRESSOR
D
HEAT
EXCHANGE
(CONDENSER)
LIQUID SIDE Intercooler
COOLING
HEATING
&RQQHFWLRQSLSHVSHFL¿FDWLRQ
Connection pipe specification:
/LTXLGPP*DVPP)RU.7$
Liquid pipe:1/4" (6mm)
/LTXLGPP*DVPP)RU.7%.
Gas pipe: 3/8" (9.52mm)
7HFKQLFDO,QIRUPDWLRQ
8 Technical Information
Service Manual
5. Electrical Part
5.1 Wiring Diagram
●Instruction
Note: Jumper cap is used to determine fan speed and the swing angle of horizontal lover for this model.
● Indoor Unit
237,21$/
52207(03
78%(7(03
:$51,1*
:,5(' 237,21$/ 3OHDVHGRQ
WWRXFKDQ\
5(&(,9(5$1' &21752//(5 :,),02'8/(
6(1625
6(1625
HOHFWURQLFFRPSRQHQWRU
',63/$<%2$5' WHUPLQDOZKHQWKHPDFKLQH
$3 $3 LVUXQQLQJVWRSSLQJRUKDV
$3 EHHQSRZHUHGRIIIRUOHVV
WKDQPLQXWHVWRSUHYHQW
HOHFWULFVKRFN
57 57 &211(&725 &211(&725
7(50,1$/
%/2&.
287'22581,7
Technical Information 9
Service Manual
● Outdoor Unit
GWH12YD-S6DBA2A/O(CB466W00200)
7(036(1625
7(036(1625
7(036(1625
7(036(1625
29(5/2$'
:$51,1*
:$<9$/9(
3527(&725 &203
28778%(
28778%(
2875220
(;+$867
3OHDVHGRQ
WWRXFKDQ\ 8 &203 3(
WHUPLQDOZKHQWKHYROWDJH 6$7
<(*1
RIWHUPLQDO3'&DQG 9 :
1'&DW$3LVKLJKHU 5' 5' %8 <( 5'
WKDQ9WRSUHYHQWWKH 57 57 57 57 ;
3(
0$*1(7,&
ULVNRIHOHFWULFVKRFN <9
5,1*
. . . / / /
:+ %. :+ %8 <( 5'
7(50,1$/ 0$*1(7,& 8%8 9<( :5'
%/2&. 5,1*
7B6(1625 6(1625 :$< 29&B&203
,1'22581,7
%8 /
1 1 %8 1
%. %. /
&20B,11(5 $3
%1 %1 /
<(*1
/ $&B/ 35,17('&,5&8,7%2$5'
<(*1
;7 3( 2)$1 +($7 :$< )$5HG )$:KLWH
%8 3(
1
/ %1%. /
<(*1 0$*1(7,& 5' 5'
5,1* <(*1 0 3(
32:(5 97 97
3( <(*1
(+ (.9 (.9
)$102725 3(
1RWH0RWRUJURXQG %27720 <9 (/(&7521,& (/(&7521,&
60000700051401 RQO\DSSOLHVWRWKH %$1' :$< (;3$16,21 (;3$16,21
LURQVKHOOPRWRU +($7(5 9$/9( 9$/9($ 9$/9(%
GWH09YD-S6DBA2A/O(CB466W00100)
7(036(1625
7(036(1625
7(036(1625
7(036(1625
29(5/2$'
:$51,1*
:$<9$/9(
3527(&725 &203
28778%(
28778%(
2875220
(;+$867
3OHDVHGRQ
WWRXFKDQ\ 8 &203 3(
WHUPLQDOZKHQWKHYROWDJH 6$7
<(*1
ULVNRIHOHFWULFVKRFN
5,1*
%8 / / %8
1 1 1
%. / / %.
&20B,11(5 $3
%1 / / %1
<(*1
/ $&B/ 35,17('&,5&8,7%2$5'
<(*1
;7 3( 2)$1 +($7 :$< )$5HG )$:KLWH
%8 3(
1
/ %1%. /
<(*1 0$*1(7,& 5' 5'
5,1* <(*1 0 3(
32:(5 97 97
3( <(*1
(+ (.9 (.9
)$102725 3(
1RWH0RWRUJURXQG %27720 <9 (/(&7521,& (/(&7521,&
RQO\DSSOLHVWRWKH %$1' :$< (;3$16,21 (;3$16,21
LURQVKHOOPRWRU +($7(5 9$/9( 9$/9($ 9$/9(%
60000700051402
These wiring diagrams are subject to change without notice; please refer to the one supplied with the unit.
10 Technical Information
Service Manual
Technical Information 11
Service Manual
● Outdoor Unit
● Top view
No. Name
2 3 4 5 6 7 8 9 10 1 Terminal of compressor
Overload Terminal of
2
compressor
1 Terminal of temperature
3
sensor
Te r m i n a l o f e l e c t r o n i c
4
expansion valve 1
Te r m i n a l o f e l e c t r o n i c
5
expansion valve 2
Low-temperature cooling
11 6
sensor
7 Terminal of outdoor fan
Terminal of chassis electric
8
heater
9 Terminal of 2-way valve
12 10 Terminal of 4-way valve
Communication wire with
13 11
indoor unit
14 12 Live wire terminal
13 Earthing wire terminal
14 Neutral wire terminal
● Bottom view
12 Technical Information
Service Manual
Fan Swing
Fan Swing ▲
▲ ▲
▲
Fan Swing
Fan Swing
Swing
Swing
Fan Swing
Fan Swing ▲
▲
▲
▲
Fan Swing
Fan Swing
3. FAN button
3. FAN button
This button is used for setting Fan Speed in the sequence that goes from AUTO, , to , then back to Auto.
This button is used for setting Fan Speed in the sequence that goes from AUTO, , to , then back to Auto.
Auto
Auto
Introduction
4.▲ /
▲
▲
button
for Icons on Display Screen
4.▲ / button
Press ▲ / button to increase/decreaseset temperature.In AUTO mode,set temperature is not adjustable.
▲
Press ▲ / button to increase/decreaseset temperature.In AUTO mode,set temperature is not adjustable.
▲
▲
▲
▲
▲
When setting Timer On or Timer Off, press ▲ or ▼ button to adjust the time. (See TIMER Button for setting details)
When setting Timer On or Timer Off, press ▲ or ▼ button to adjust the time. (See TIMER Button for setting details)
5. SWING button
5. SWING button
Press this button to set up & down swing angle.
Press this button to set up & down swing angle.
no display
no display
(horizontal louvers
(horizontalstops at current position)
louvers
stops at current position)
ATUO
Technical Information 13
ATUO
Service Manual
2. FAN button
Low
Press this button, Auto, Low, fan Medium-low
Medium-low, fan Medium
Medium, Medium-high, High fan
speed canMedium-high fan
be circularly selected. High
After fan
powered on, Auto fan speed
is default. Under DRY mode, Low fan speed only can be set up.
ATUO
Note: It’s Low fan speed
under Dry mode.
Low fan Medium-low fan Medium fan Medium-high fan High fan
3. MODE button
Press this button, Auto, Cool, Dry, Fan, Heat mode can be selected circularly. Auto mode is default while power on. Under Auto mode, the
temperature will not be displayed;Under Heat mode, the initial value is 28°C( 82°F);Under other modes, the initial value is 25°C(77°F).
OFF OFF
OFF
OFF
7. button
Press this button to set swing angle,which circularly changes as below:
OFF OFF
OFF
OFF
This remote controller is universal. If it receives threes kinds of following
OFF status,the swing angle will remain origial.
OFF
OFF
If guide louver is stopped when it is swinging up and down,it will remain its present position.
OFF OFF
indicates guide louver swings back and forth in the five places,as shown in the figure.
8. CLOCK button
Press this button, the clock can be set up,signal blink and display.Within
OFF 5OFF
seconds, the value can be adjusted by pressing + or - button,
if continuously press this button for 2 seconds above,in every 0.5 seconds, the value on ten place of Minute will be increased 1.During
blinking,repress the Clock button or Confirm button,signal will be constantlyOFF
displayed and it denotes the setting succeeded. After
OFF
powered on, 12:00 is defaulted to display and signal will be displayed.OFF
If there is signal be displayed thatOFF
denotes the current time
value is Clock value, otherwise is Timer value.
9. TIMER ON/TIMER OFF button
● Timer On setting: Signal “ON”will blink and display,signal will conceal,the numerical
OFF section will become the timer on setting status.
During 5 seconds blink,by pressing + or - button to adjust the time value of numerical section,every press of that button,the value will be
increased or decreased 1 minute.Hold pressing + or - button,2 seconds later,it quickly change,the way of change is: During the initial 2.5
seconds,ten numbers change in the one place of minute,then the one place is constant,ten numbers change in the ten splace of minute at
2.5 seconds speed and carry. During 5s blink,press the Timer button,the timer setting succeeds.The Timer On has been set up,repress the
timer button,theTimer On will be canceled. Before setting theTimer,please adjust the Clock to the current actual time.
● One press this key to enter into TIMER OFF setup, in which case the TIMER OFF icon will blink. The method of setting is the sameas for
TIMER ON.
14 Technical Information
Service Manual
When selecting " " with remote controller or no display, temperature indicator on indoor unit displays set temperature; When selecting
" " with remote controller,temperature indicator on indoor unit displays indoor ambient temperature; When selecting " " with remote
controller, temperature indicator on indoor unit displays outdoor ambient temperature. 3s later it will return to the setting temprature or it
depends on the other received signal within 3s.
Attention: When displaying the outdoor ambient, the displaying range is 32-99°F and 0-60°C.When it goes beyond the range, it keeps the
threshold data (the smallest—0°C or 32°F and the largest 99°F or 60°C).
Warm tips: When operating buttons on the cover please make sure the cover is closed completely.
11. / button(This function is only available for some models)
Press this button to achieve the on and off of healthy and scavenging functions in operation status.Press this button for the first
time to start scavenging function;LCD displays“ ”.Press the button for the second time to start healthy and scavenging functions
simultaneously;LCD displays“ ”and “ ” .Press this button for the third time to quit healthy and scavenging functions simultaneously.
Press the button for the fourth time to start healthy function; LCD display“ ” .Press this button again to repeat the operation above.
12. I FEEL button
Press this button once, to turn on the I FEEL function, then the figure of "I FEEL" will be displayed, after every press of other function
button, every 200ms to send I FEEL once, after this function started,the remote control will send temperature to the main un it in every 10
minutes.When repress this button, this function will be turned off.
13. LIGHT button
Press this button at unit On or Off status,Light On and Light Off can be set up.After powered on, Light On is defaulted.
14. X-FAN button
Pressing X-FAN button in COOL or DRY mode,the icon is displayed and the indoor fan will continue operation for 2 minutes in order
to dry the indoor unit even though you have turned off the unit.After energization, X-FAN OFF is defaulted.X-FAN is not available in
AUTO,FAN or HEAT mode.
15. QUIET button
Press this button,the Quiet status is under the Auto Quiet mode (display" " and “Auto”signal ) and Quiet mode(display " " singal) and
Quiet OFF(there is no signal of " " displayed),after powered on,the Quiet OFF is defaulted. Under the Quiet mode (Display " "signal),
the fan speed is not available.
16. SLEEP button
●Press this button, can select Sleep 1 ( ), Sleep 2 ( ),Sleep 3 ( ) and cancel the Sleep, circulate between these, after
electrified, Sleep Cancel is defaulted.
●Sleep 1 is Sleep mode 1, in Cool, Dehumidify modes: sleep status after run for one hour, the main unit setting temperature will increase
1°C(1ºF~2ºF), 2 hours,setting temperature increased 2°C(3ºF~4ºF), the unit will run at this setting temperature; In Heat mode: sleep status
after run for one hour, the setting temperature will decrease 1°C(1ºF~2ºF), 2 hours, setting temperature will decrease 2°C(3ºF~4ºF), then
the unit will run at this setting temperature.
●Sleep 2 is sleep mode 2, that is air conditioner will run according to the presetting a group of sleep temperature curve.
In Cool mode:
(1) When setting the initial temperature 16~23°C(61ºF~74ºF), after turned on Sleep function, the temperature will be increased 1°C(1ºF~2ºF)
in every hour,after 3°C(5ºF~6ºF) the temperature will be maintained, after 7hours,the temperature will be decreased 1°C(1ºF~2ºF), after
that the unit will keep on running under this temperature;
(2) When setting the initial temperature 24~27°C(75ºF~81ºF), after turned on Sleep function, the temperature will be increased 1°C(1ºF~2ºF)
in every hour,after 2°C(3ºF~4ºF) the temperature will be maintained, after 7hours,the temperature will be decreased 1°C(1ºF~2ºF) , after
that the unit will keep on running under this temperature;
(3) When setting the initial temperature 28~29°C(82ºF~85ºF), after turned on Sleep function, the temperature will be increased 1°C(1ºF~2ºF)
in every hour, after 1°C(1ºF~2ºF) the temperature will be maintained, after 7hours,the temperature will be decreased 1°C(1ºF~2ºF) , after
that the unit will keep on running under this temperature;
(4) When setting the initial temperature 30°C(86ºF), under this temperature setting, after 7hours, the temperature will be decreased
1°C(1ºF~2ºF), after that the unit will keep on running under this temperature;
In Heat mode:
(1) Under the initial presetting temperature 16°C(61ºF), it will run under this setting temperature all along.
(2) Under the initial presetting temperature17~20°C(62ºF~68ºF), after Sleep function started up, the temperature will decrease 1°C(1ºF~2ºF)
in every hour, after 1°C(1ºF~2ºF) decreased, this temperature will be maintained.
(3) Under the initial presetting temperature 21~27°C(69ºF~81ºF), after Sleep function started up, the temperature will decrease
1°C(1ºF~2ºF) in every hour,after 2°C(3ºF~4ºF) decreased, this temperature will be maintained.
(4) Under the initial presetting temperature 28~30°C(82ºF~86ºF), after Sleep function started up, the temperature will decrease
1°C(1ºF~2ºF) in every hour, after 3°C(5ºF~6ºF) decreased, this temperature will be maintained.
Technical Information 15
Service Manual
16 Technical Information
Service Manual
1
28.WIFI Function
Press "MODE" and "TURBO" button simultaneously to turn on or turn off WIFI function. When WIFI function is turned on, the
" " icon will be displayed on remote controller; Long press "MODE" and "TURBO" buttons simultaneously for 10s, remote 4
controller will send WIFI reset code and then the WIFI function will be turned on. WIFI function is defaulted ON after1 energization 2
of the remote controller.(This function only applicable for some models. )
3
Operation Guide 5
4
1 2
1. General operation
3
(1)After powered on, press ON/OFF button, the unit will start to run. (Note: When it is powered on, the
guide louver of main unit will close automatically.) 5
(2)Press MODE button, select desired running mode.
(3)Pressing + or - button, to set the desired temperature (It is unnecessary to set the temp. at AUTO
mode.)
(4)Pressing FAN button, set fan speed, can select AUTO FAN,LOW, MEDIUM-LOW, MEDIUM, MEDIUM-
4
HIGH and HIGH.
(5)Pressing and button, to select the swing.
3
2. Optional operation 4
2
(1)Press SLEEP button, to set sleep.
4
(2)Press TIMER ON and TIMER OFF button, can set the scheduled timer on or timer off. 2
(3)Press LIGHT button, to control the on and off of the displaying part of the unit (This function may be not 3 1
available for some units). 3 1
(4)Press TURBO button, can realize the ON and OFF of TURBO function.
Technical Information 17
Service Manual
YAG1FB3(WiFi)
1 ON/OFF button
2 FAN button
3 MODE button
4 +/- button
5 TURBO button
2
2 6 button
5 6
4 7 button
4 11
7
3
3 9
8 8 CLOCK button
10 12
1 13 WiFi
1 9 TIMER ON/
14 16
15 TIMER OFF button
10 TEMP button
11 / button
(before opening cover (after opening cover
12 I FEEL button
1 ON/OFF button 13 LIGHT button
2 FAN button 14 WiFi button
3 MODE button 15 QUIET button
4 +/- button 16 SLEEP button
● This is a general use remote controller, it could be used for the air conditioners with multifunction; For some function, which the
model doesn't have, if press the corresponding button on the remote controller that the unit will keep the original running status.
18 Technical Information
Service Manual
ATUO
Low fan Medium-low fan Medium fan Medium-high fan High fan
Note:
● It’s Low fan speed under Dry mode.
● X-FAN function:Hold fan speed button for 2s in COOL or DRY mode, the icon “ ” is displayed and the indoor fan will continue
operation for a few minutes in order to dry the indoor unit even though you have turned off the unit. After energization, X-FAN OFF is
defaulted. X-FAN is not available in AUTO, FAN or HEAT mode.
This function indicates that moisture on evaporator of indoor unit will be blowed after the unit is stopped to avoid mould.
● Having set X-FAN function on: After turning off the unit by pressing ON/OFF button indoor fan will continue running for a few minutes. at
low speed. In this period, Hold fan speed button for 2s to stop indoor fan directly.
● Having set X-FAN function off: After turning off the unit by pressing ON/OFF button, the complete unit will be off directly.
Press " + " or " - " button once increase or decrease set temperature 1°C(°F). Holding " + " or " - " button, set temperature on remote
controller will change quickly. On releasing button after setting is finished, temperature indicator on indoor unit will change accordingly.
When setting TIMER ON, TIMER OFF or CLOCK, press " + " or " - " button to adjust time. (Refer to CLOCK, TIMER ON, TIMER OFF
buttons) When setting TIMER ON, TIMER OFF or CLOCK, press " + " or " - " button to adjust time. (Refer to CLOCK, TIMER ON,
TIMER OFF buttons)
OFF
OFF
Technical Information 19
Service Manual
Note:
Outdoor temperature display is not available for some models. At that time, indoor unit receives " " signal, while it displays indoor
set temperature.
Press this button once, to turn on the I FEEL function, then the figure of "I FEEL"will be displayed, after every press of other function button,
every 200ms to sendI FEEL once, after this function started, the remote controller will send temperatureto the main un it in every 10 minutes.
When repress this button, this function will beturned off. When I FEEL function is turned on, the remote controller should be put within the
area where indoor unit can receive the signal sent by the remote controller.
WiFi button
Press " WiFi " button to turn on or turn off WiFi function. When WiFi function is turned on, the " WiFi " icon will be displayed on remote
controller; Under status of remote controller off, press "MODE" and " WiFi " buttons simultaneously for 1s, WiFi module will restore to
factory default setting.
● This function is only available for some models.
Press this button, the Quiet status is under the Auto Quiet mode (display" "and "Auto" signal) and Quiet mode (display " " singal)
and Quiet OFF (there is no signal of " " displayed), after powered on, the Quiet OFF is defaulted.Under the Quiet mode (Display " "
signal).
The Quiet function is only available for some models.
Press this button, can select Sleep 1 ( ), Sleep 2 ( ), Sleep 3 ( ) andcancel the Sleep, circulate between these, after electrified,
Sleep Cancel is de-faulted.
Sleep 1 is Sleep mode 1, in Cool modes: sleep status after run for one hour, the main unit setting temperature will increase 1℃, 2 hours,
setting temperatureincreased 2℃, the unit will run at this setting temperature; In Heat mode:sleep status after run for one hour, the setting
temperature will decrease 1℃, 2 hours, setting temperature will decrease 2℃, then the unit will run at this settingtemperature.
Sleep 2 is sleep mode 2, that is air conditioner will run according to the presettinga group of sleep temperature curve.
In Cool mode:
(1) When setting the initial temperature 16℃-23℃, after turned on Sleep function,the temperature will be increased 1℃ in every hour,
after 3℃ the temperaturewill be maintained, after 7hours, the temperature will be decreased 1℃, afterthat the unit will keep on running
under this temperature;
(2) When setting the initial temperature 24℃-27℃, after turned on Sleep function,the temperature will be increased 1℃ in every hour,
after 2℃ the temperaturewill be maintained, after 7hours, the temperature will be decreased 1℃, afterthat the unit will keep on running
under this temperature;
(3) When setting the initial temperature 28℃-29℃, after turned on Sleep function,the temperature will be increased 1℃ in every hour,
after 1℃ the temperature will be maintained, after 7hours, the temperature will be decreased 1℃, afterthat the unit will keep on running
under this temperature;
20 Technical Information
Service Manual
(4) When setting the initial temperature 30℃, under this temperature setting, after 7hours, the temperature will be decreased 1℃, after
that the unit will keep onrunning under this temperature;
In Heat mode:
(1) Under the initial presetting temperature 16℃, it will run under this setting temperature all along.
(2) Under the initial presetting temperature17℃-20℃, after Sleep function started up, the temperature will decrease 1℃ in every hour,
after 1℃ decreased, thistemperature will be maintained.
(3) Under the initial presetting temperature 21℃-27℃, after Sleep function started up, the temperature will decrease 1℃ in every hour,
after 2℃ decreased, thistemperature will be maintained.
(4) Under the initial presetting temperature 28℃-30℃, after Sleep function started up, the temperature will decrease 1℃ in every hour,
after 3℃ decreased, thistemperature will be maintained.
Sleep 3 - the sleep curve setting under Sleep mode by DIY:
(1) Under Sleep 3 mode, press "Turbo" button for a long time, remote controller enters into user individuation sleep setting status, at this
time, the time of remotecontroller will display "1hour", the setting temperature "88" will display the corr-esponding temperature of last setting
sleep curve and blink (The first enteringwill display according to the initial curve setting value of original factory);
2) Adjust "+" and "-" button, could change the corresponding setting temperature,after adjusted, press "Trubo" button for confirmation;
(3) At this time, 1hour will be automatically increased at the timer postion on the remote controller, (that are "2hours" or "3hours" or "8hours"),
the place of setting temperature "88" will display the corresponding temperature of last settingsleep curve and blink;
(4) Repeat the above step (2)~(3) operation, until 8hours temperature setting finished,sleep curve setting finished, at this time, the remote
controller will resume theoriginal timer display; temperature display will resume to original setting temperature.
Sleep3 - the sleep curve setting under Sleep mode by DIY could be inquired:The user could accord to sleep curve setting method to inquire
the presetting sleepcurve, enter into user individuation sleep setting status, but do not change the temperature, press "Turbo" button directly
for confirmation.
Note: In the above presetting or enquiry procedure, if continuously within10s, thereis no button pressed, the sleep curve setting status will
be automatically quitand resume to display the original displaying. In the presetting or enquiry pr-ocedure, press "ON/OFF" button, "Mode"
button, "Timer" button or "Sleep" button, the sleep curve setting or enquiry status will quit similarly.
Technical Information 21
Service Manual
3
1. After powered on, press ON/OFF button, the unit will start 5
2
to run. (Note: When it is powered on, the guide louver of
main unit will close automatically.) 1
2. Press MODE button, select desired running mode. WiFi
battery
1. Press the back side of remote controller marked
reinstall
the cover of battery box along the arrow direction.
2. Replace two 7# (AAA 1.5V) dry batteries, and remove
make sure the position of "+" polar and "-" polar
are correct.
3. Reinstall the cover of battery box.
● During operation, point the remote control signal sender at the receiving
window on indoor unit.
● The distance between signal sender and receiving window should be no
more than 8m, and there should be no obstacles between them.
● Signal may be interfered easily in the room where there is fluorescent lamp
or wireless telephone; remote controller should be close to indoor unit during
operation.
● Replace new batteries of the same model when replacement is required.
● When you don’t use remote controller for a long time, please take out the
batteries.
● If the display on remote controller is fuzzy or there’s no display, please
replace batteries.
22 Technical Information
Service Manual
Internet
Gree Cloud
Gree
intelligent Home Wi-Fi Cellular/
home Other Wi-FI
appliances
Home wireless router
Home Wi-Fi
GREE+ APP
Operating Systems
Scan the QR code or search "GREE+" in the application market to download and install it. When "GREE+" App is installed, register the
account and add the device to achieve long-distance control and LAN control of Gree smart home appliances.
For more information, please refer to "Help" in App.
Technical Information 23
Service Manual
Internet
Cloud
Operating Systems
Scan the QR code or search "Ewpe Smart" in the application market to download and install it. When "Ewpe Smart" App is installed,
register the account and add the device to achieve long-distance control and LAN control of smart home appliances.
For more information, please refer to "Help" in App.
24 Technical Information
Service Manual
Tpreset –2 ˚C
Stop cooling
≥ 6 min. ≥ 3 min. ≥ 6 min.
Outdoor fan
Compressor 3 min
30S
Outdoor fan
Indoor fan Preset speed
Run Stop
(2) Dehumidifying Mode
① Working conditions and process of dehumidifying
If Tamb.>Tpreset, the unit will enter cooling and dehumidifying mode, in which case the compressor and the outdoor fan will operate and the indoor
fan will run at low speed.
If Tpreset-2°C(3.6°F)≤Tamb.≤Tpreset, the compressor remains at its original operation state.
If Tamb.< Tpreset-2°C(3.6°F), the compressor will stop, the outdoor fan will stop with a time lag of 30s, and the indoor fan will operate at low speed.
② Protection function
Protection is the same as that under the cooling mode.
(3) Heating Mode
① The condition and process of heating
If Tamb.≤Tpreset+2°C(3.6°F), heating mode will act, the compressor, outdoor fan and reversal valve will run, the indoor fan will delay 3min to stop at
the latest
If Tpreset +2°C(3.6°F)<Tamb.<Tpreset +5°C(9°F),the unit will keep running in the original mode.
If Tamb.≥Tpreset+5°C(9°F), the compressor will stop, the outdoor fan will delay 30s to stop and indoor fan will blow 60s at low speed, the fan speed
cannot be shifted within blow residual heat.
◆ In this mode, the temperature setting range is 16 ~30°C(68~86°F).
◆ The air conditioner will adjust the running frequency of the compressor automatically according to the change of ambient temperature.
◆ When the unit is turned off in heating mode, or switched to other mode from heating mode, the four-way valve will be powered off after the
compressor stops.
Stop heating
Tpreset+5
Original operating status
Tpreset+2
Tamb.
6min. 3min. 6min. Start heating
Outdoor fan
60s 60s
Indoor fan <2 min. preset <2 min. preset
wind wind
Reversing valve
Run Stop
c.For heating and cooling unit, when 22°C(71.6°F)<Tindoor ambient<26°C(78.8°F) (for cooling only unit, 22°C(71.6°F)<Tindoor
ambient<26°C)(78.8°F), it will keep the original running mode. If the unit is energized for the first time, it will run in fan mode.
② Protection
a. In cooling operation, protection is the same as that under the cooling mode;
b. In heating operation, protection is the same as that under the heating mode;
c. When ambient temperature changes, operation mode will be converted preferentially. Once started, the compressor willremain
unchanged for at least 6 minutes.
(7)Common Protection Functions and Fault Display under COOL, HEAT, DRY and AUTO Modes
① Overload protection
Ttube: measured temperature of outdoor heat exchanger under cooling mode; and measured temperature of indoor heat exchanger under
heating mode.
1) Cooling overload
a.If T tube≤52°C(125.6°F), the unit will return to its original operation state.
b.If T tube≥55°C(131°F), frequency rise is not allowed.
c.If T tube≥58°C(136.4°F), the compressor will run at reduced frequency.
d.If T tube≥62°C(143.6°F), the compressor will stop and the indoor fan will run at preset speed.
2) Heating overload
a.If T tube≤50°C(122°F), the unit will return to its original operation state.
b.If T tube≥53°C(127.4°F), frequency rise is not allowed.
c.If T tube≥56°C(132.8°F), the compressor will run at reduced frequency.
d.If T tube≥60°C(140°F), the compressor will stop and the indoor fan will blow residue heat and then stop.
② Exhaust temperature protection of compressor
If exhaust temperature≥98°C(208.4°F), frequency is not allowed to rise.
If exhaust temperature≥103°C(217.4°F), the compressor will run at reduced frequency.
If exhaust temperature≥110°C(230°F),, the compressor will stop.
If exhaust temperature≤90°C(194°F), and the compressor has stayed at stop for at least 3 minutes, the compressor will resume its operation.
③ Communication fault
If the unit fails to receive correct signals for durative 3 minutes, communication fault can be justified and the whole system will stop.
④ Module protection
Under module protection mode, the compressor will stop. When the compressor remains at stop for at least 3 minutes, the compressor will
resume its operation. If module protection occurs six times in succession, the compressor will not be started again.
⑤ Overload protection
If temperature sensed by the overload sensor is over 115 , the compressor will stop and the outdoor fan will stop with a time lag of 30
seconds. If temperature is below 95 , the overload protection will be relieved.
⑥ DC bus voltage protection
If voltage on the DC bus is below 150V or over 420V, the compressor will stop and the outdoor fan will stop with a time lag of 30 seconds.
When voltage on the DC bus returns to its normal value and the compressor has stayed at stop for at least 3 minutes, the compressor will
resume its operation.
⑦ Faults of temperature sensors
Designation of sensors Faults
Indoor ambient temperature The sensor is detected to be open-circuited or short-circuited for successive 5 seconds
Indoor tube temperature The sensor is detected to be open-circuited or short-circuited for successive 5 seconds
Outdoor ambient temperature The sensor is detected to be open-circuited or short-circuited for successive 30 seconds
The sensor is detected to be open-circuited or short-circuited for successive 30 seconds, and no
Outdoor tube temperature
detection is performed within 10 minutes after defrost begins.
After the compressor has operated for 3 minutes, the sensor is detected to be open-circuited or
Exhaust
short-circuited for successive 30 seconds.
After the compressor has operated for 3 minutes, the sensor is detected to be open-circuited or
Overload
short-circuited for successive 30 seconds.
3. Other Controls
(1) ON/OFF
Press the remote button ON/OFF: the on-off state will be changed once each time you press the button.
(2) Mode Selection:
Press the remote button MODE, then select and show in the following ways: AUTO, COOL, DRY, FAN, HEAT, AUTO.
(3) Temperature Setting Option Button
Each time you press the remote button TEMP+ or TEMP-, the setting temperature will be up or down by 1°C(1.8°F). Regulating Range:
16(60.8°F)~30°C(86°F), the button is useless under the AUTO mode.
(4) Time Switch
You should start and stop the machine according to the setting time by remote control.
(5) SLEEP State Control
1. In cooling mode:
1.1 When the initial set temperature is16-23°C(60.8~73.4°F),the temperature will rise 1°C(1.8°F) by every hour after sleep function is set;the
temperature will not change after rising 3°C(5.4°F) ;after running for 7hours,the temperature will decrease1°C(1.8°F) and it will not change
after that.
1.2 When the initial set temperature is 24-27°C(75.2~80.6°F),the temperature will rise 1°C(1.8°F) by every hour after sleep function is set; the
temperature will not change after rising 2°C(3.6°F) ;after running for 7 hours, the temperature will decrease 1°C(1.8°F) and it will not change
after that.
1.3 When the initial set temperature is 28-29°C(82.4~84.2°F),the temperature will rise 1°C(1.8°F) by every hour after sleep function is set; the
temperature will not change after rising 1°C(1.8°F) ; after running for 7 hours, the temperature will decrease 1°C(1.8°F) and it will not change
after that.
1.4 When the initial set temperature is 30°C(86°F) , the unit will keep on running at this temperature; after running for 7 hours, the temperature
will decrease 1°C(1.8°F) and it will not change after that.
Relationship between set temperature and running time:
2. In heating mode:
2.1 When the initial set temperature is 16°C(60.8°F), the unit will keep on running at this temperature;
2.2 When the initial set temperature is 17-20°C(62.6~68°F), the temperature will decrease 1°C(1.8°F) by every hour after sleep function is set;
the temperature will not change after decreasing 1°C(1.8°F);
2.3 When the initial set temperature is 21-27°C(69.8~80.6°F), the temperature will decrease 1°C(1.8°F) by every hour after sleep function is
set; the temperature will not change after decreasing 2°C(3.6°F);
2.4 When the initial set temperature is 28-30°C(82.4~86°F), the temperature will decrease 1°C(1.8°F) by every hour after sleep function is set;
the temperature will not change after decreasing 3°C(5.4°F);
Relationship between set temperature and running time:
Initial Temp. Running time(T)
0(start) 1 2 3 4 5 6 7 8
16 16 16 16 16 16 16 16 16
17 16 16 16 16 16 16 16 16
18 17 17 17 17 17 17 17 17
19 18 18 18 18 18 18 18 18
20 19 19 19 19 19 19 19 19
21 20 19 19 19 19 19 19 19
22 21 20 20 20 20 20 20 20
23 22 21 21 21 21 21 21 21
24 23 22 22 22 22 22 22 22
25 24 23 23 23 23 23 23 23
26 25 24 24 24 24 24 24 24
27 26 25 25 25 25 25 25 25
28 27 26 25 25 25 25 25 25
29 28 27 26 26 26 26 26 26
30 29 28 27 27 27 27 27 27
(6) Indoor Fan Control
Indoor fan could be set at ultra-high, high, medium, low speed by wireless remote controller and operated as that speed.
Auto fan speed could be set as well, indoor fan will operate under auto fan speed as following:
1. Under heating mode: auto speed under heating or auto heating mode:
a. When Tamb.≤Tpreset+1°C(1.8°F), indoor fan will operate at high speed;
b. When Tpreset+1°C(1.8°F)<Tamb.<Tpreset+3°C(5.4°F), indoor fan will operate at medium speed;
c. When Tamb.≥Tpreset+3°C(5.4°F), indoor fan will operate at low speed;
There should be at least 180s operation time during switchover of each speed.
2. Under cooling mode: auto speed under cooling or auto cooling mode:
a. When Tamb.≥Tpreset+2°C(3.6°F), indoor fan will operate at high speed;
b. When Tpreset<Tamb.<Tpreset+2°C(3.6°F), indoor fan will operate at medium speed;
c. When Tamb.≤Tpreset, indoor fan will operate at low speed
There should be at least 210s operation time during switchover of each speed.
(7) Buzzer Control
The buzzer will send a “Di” sound when the air conditioner is powered up or received the information sent by the remote control or there is
a button input, the single tube cooler doesn’t receive the remote control ON signal under the mode of heating mode.
(8) Auto button
If the controller is on, it will stop by pressing the button, and if the controller is off, it will be automatic running state by pressing the button,
swing on and light on, and the main unit will run based on the remote control if there is remote control order.
(9) Up-and-Down Swinging Control
Heating angle O(0°) Cooling angle Heating angle O(0°) Coolin
When power on, the up-and-down motor will firstly move the air
O(0°)
deflector to o counter-clockwise, close the air outlet.
After starting the machine, if you don’t set the swinging functi on, L1
heating mode and auto-heating mode, the up-and-down air deflector L A1 L
will move to D clockwise; under other modes, the up-and-down A air B1 A
deflector will move to L1. If you set the swinging function whenB you start C1 B
the machine, then the wind blade will swing between L and D.CThe air D1 C
deflector has 7 swinging states: Location L, Location A, Location D B, Location C, D
Location D, Location L to Location D, stop at any location between L-D (the included angle between L~D is the same).
The air deflector will be closed at 0 Location, and the swinging is effectual only on condition that setting the swinging order and the inner
fan is running. The indoor fan and compressor may get the power when air deflector is on the default location.
(10) Display
① Operation pattern and mode pattern display
All the display patterns will display for a time when the power on, the operation indication pattern will display in red under standby status.
When the machine is start by remote control, the indication pattern will light and display the current operation mode (the mode light in-
cludes: Cooling, heating and dehumidify). If you close the light key, all the display patterns will close.
② Double-8 display
According to the different setting of remote control, the nixie light may display the current temperature (the temperature scope is from 16°C
(60.8°F)to 30°C(86°F)) and indoor ambient temperature. The set temperature displayed in auto cooling and fan mode is 25°C(77°F) and
the set temperature displayed in auto heating mode is 20°C(68°F). Under heating mode, nixie tube displays H1 or heating indicator is off 0.5s
and blinks 10s in defrosting.(If you set the fahrenheit temperature display, the nixie light will display according to fahrenheit temperature)(11)
Protection function and failure display
E2: Freeze-proofing protection E4: Exhausting protecti on E5: Overcurrent protection E6: Communication failure
F1: Indoor ambient sensor start and short circuit (continuously measured failure in 5s)
F2: Indoor evaporator sensor start and short circuit (continuously measured failure in 5s)
F3: Outdoor ambient sensor start and short circuit (continuously measured failure in 30s)
F4: Outdoor condenser sensor start and short circuit (continuously measured failure in 30s, and don’t measure within 10 minutes after
defrosted)
F5: Outdoor exhausting sensor start and short circuit (continuously measured failure in 30s after the compressor operated 3 minutes)
H3: Overload protection of compressor H5: Module protection PH: High-voltage protection PL: Low-voltage protection
P1: Nominal cooling and heating test P2: Maximum cooling and heating test
P3: Medium cooling and heating test P0: Minimum cooling and heating test
(12) Drying Function
You may start or stop the drying function under the modes of cooling and dehumidify at the starting status (The modes of automatism,
heating and air supply do not have drying function). When you start the drying function, after stop the machine by pressing the switch
button, you should keep running the inner fans for 2 minutes under low air damper (The swing will operate as the D1 status within 2
minutes, and other load is stopped), then stop the entire machine; When you stop the drying function, press the switch button will stop the
machine directly.When you start the drying function, operating the drying button will stop the inner fans and close the guide louver.
(13) Memory Function
When interrupting the power supply memory content: mode, swing function, light, set temperature and wind speed.
After interrupted the power supply, the machine will start when recovering the power according to the memory content automatically.
Warnings
cient fixing bolt must be installed; make sure the installation
support is firm.
4. Ware safety belt if the height of working is above 2m.
5. Use equipped components or appointed components dur-
ing installation.
Electrical Safety Precautions: 6. Make sure no foreign objects are left in the unit after fin-
ishing installation.
1. Cut off the power supply of air conditioner before
checking and maintenance. Refrigerant Safety Precautions:
2. The air condition must apply specialized circuit and
prohibit share the same circuit with other appliances. 1. Avoid contact between refrigerant and fire as it generates
3. The air conditioner should be installed in suitable poisonous gas; Prohibit prolong the connection pipe by
location and ensure the power plug is touchable. welding.
4. Make sure each wiring terminal is connected firmly 2. Apply specified refrigerant only. Never have it mixed with
during installation and maintenance. any other refrigerant. Never have air remain in the refrigerant
5. Have the unit adequately grounded. The grounding line as it may lead to rupture or other hazards.
wire cant be used for other purposes. 3. Make sure no refrigerant gas is leaking out when
6. Must apply protective accessories such as protective installation is completed.
boards, cable-cross loop and wire clip. 4. If there is refrigerant leakage, please take sufficient
7. The live wire, neutral wire and grounding wire of measure to minimize the density of refrigerant.
power supply must be corresponding to the live wire, 5. Never touch the refrigerant piping or compressor without
neutral wire and grounding wire of the air conditioner. wearing glove to avoid scald or frostbite.
8. The power cord and power connection wires cant be
pressed by hard objects. Improper installation may lead to fire hazard, explosion,
9. If power cord or connection wire is broken, it must be electric shock or injury.
replaced by a qualified person.
Warnings
1. When installing or relocating the unit, be sure to keep the refrigerant circuit free from air or substances other than the
specified refrigerant.
Any presence of air or other foreign substance in the refrigerant circuit will cause system pressure rise or compressor rupture, resulting in
injury.
2.When installing or moving this unit, do not charge the refrigerant which is not comply with that on the nameplate or
unqualified refrigerant.
Otherwise, it may cause abnormal operation, wrong action, mechanical malfunction or even series safety accident.
3.When refrigerant needs to be recovered during relocating or repairing the unit, be sure that the unit is running in cooling
mode.Then, fully close the valve at high pressure side (liquid valve).About 30-40 seconds later, fully close the valve at low
pressure side (gas valve), immediately stop the unit and disconnect power. Please note that the time for refrigerant recovery
should not exceed 1 minute.
If refrigerant recovery takes too much time, air may be sucked in and cause pressure rise or compressor rupture, resulting in injury.
4.During refrigerant recovery, make sure that liquid valve and gas valve are fully closed and power is disconnected before
detaching the connection pipe.
If compressor starts running when stop valve is open and connection pipe is not yet connected, air will be sucked in and cause pressure
rise or compressor rupture, resulting in injury.
5.When installing the unit, make sure that connection pipe is securely connected before the compressor starts running.
If compressor starts running when stop valve is open and connection pipe is not yet connected, air will be sucked in and cause pressure
rise or compressor rupture, resulting in injury.
6.Prohibit installing the unit at the place where there may be leaked corrosive gas or flammable gas.
If there leaked gas around the unit, it may cause explosion and other accidents.
7.Do not use extension cords for electrical connections. If the electric wire is not long enough, please contact a local service
center authorized and ask for a proper electric wire.
Poor connections may lead to electric shock or fire.
8.Use the specified types of wires for electrical connections between the indoor and outdoor units. Firmly clamp the wires so
that their terminals receive no external stresses.
Electric wires with insufficient capacity, wrong wire connections and insecure wire terminals may cause electric shock or fire.
WARNING:
●Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacture.
Should repair be necessary,contact your nearest authorized Service Centre. Any repairs carried out by unqualified
personnel may be dangerous. The appliance shall be stored in a room without continuously operating ignition sources. (for
example:open flames , an operating gas appliance or an operating electric heater.)
●Do not pierce or burn.
●Appliance shall be installed, operated and stored in a room with a floor area larger than 4m (or 6m ).
●Appliance filled with flammable gas R32. For repairs, strictly follow manufacturers instructions only.Be aware that refrigrants
not contain odour.
●Read specialists manual.
Installation notes
●The air conditioner is not allowed to use in a room that has running fire (such as fire source,working coal gas ware,
operating heater).
●It is not allowed to drill hole or burn the connection pipe.
●The air conditioner must be installed in a room that is larger than the minimum room area.
The minimum room area is shown on the nameplate or following table a.
●Leak test is a must after installation.
table a - Minimum room area(m2)
Maintenance notes
●Check whether the maintenance area or the room area meet the requirement of the nameplate.
— Its only allowed to be operated in the rooms that meet the requirement of the nameplate.
●Check whether the maintenance area is well-ventilated.
— The continuous ventilation status should be kept during the operation process.
●Check whether there is fire source or potential fire source in the maintenance area.
— The naked flame is prohibited in the maintenance area; and the “no smoking” warning board should be hanged.
●Check whether the appliance mark is in good condition.
— Replace the vague or damaged warning mark.
Welding
●If you should cut or weld the refrigerant system pipes in the process of maintaining, please follow the steps as below:
a. Shut down the unit and cut power supply
b. Eliminate the refrigerant
c. Vacuuming
d. Clean it with N2 gas
e. Cutting or welding
f. Carry back to the service spot for welding
●Make sure that there isnt any naked flame near the outlet of the vacuum pump and its well-ventilated.
●The refrigerant should be recycled into the specialized storage tank.
10. Pipe pliers, pipe cutter 11. Pipe expander, pipe bender 12. Soldering appliance, refrigerant container
8. Installation
8.1 Installation Dimension Diagram
At least 5 7/8
At least 98 7/16
A t stru
ob
he
ot
et
ac
Sp
n
ctio
s tru
ob 16
he 13/
t ot 11
c e st
Sp a lea
ac Sp At
et
ot
At he
lea wa
st 1 ll
11
3/1
6
o
cti Drainage pipe
s tru /8
ob 85
he t7
tot as Sp
ac
ce le
pa At At
et
ot
S lea he
st 1 ob
91 str
1/1 uc
6 tio
n
Installation procedures
Start installation
Finish installation
Note: this flow is only for reference; please find the more detailed installation steps in this section.
Left Right
Φ55mm Φ55mm
Rear piping hole Rear piping hole
Fig.1
Insulating pipe Fig.7
(2) Open a piping hole with the diameter of Φ70mm on the
selected outlet pipe position.In order to drain smoothly, slant Refer to the following table for wrench moment of force:
the piping hole on the wall slightly downward to the outdoor
side with the gradient of 5-10°.(As show in Fig.2) Hex nut diameter(mm) Tightening torque(N.m)
Φ6 15~20
Indoor Outdoor Φ9.52 30~40
Φ12 45~55
Φ16 60~65
Φ19 70~75
Φ55mm
5-10°
6. Install Drain Hose
(1) Connect the drain hose to the outlet pipe of indoor unit.(As
show in Fig.8)
Fig.2 (2) Bind the joint with tape.(As show in Fig.9)
Note:
(1) Pay attention to dust prevention and take relevant safety
measures when opening the hole.
Fig.8 Drain hose
(2) The plastic expansion particles are not provided and should
be bought locally. Outlet pipe
(2) Make the power connection wire go through the cable-cross Indoor and
hole at the back of indoor unit and then pull it out from the front Indoor unit
outdoor power cord
Gas
side.(As show in Fig.12) pipe
Power connection
wire
Connection pipe Drain hose
Band
Fig.12
(3) Remove the wire clip; connect the power connection wire
and signal control wire to the wiring terminal according to the
Fig.15
color; tighten the screw and then fix them with wire clip.(As
Indoor power cord
show in Fig.13)
Note:
N(1) 2 3
(1) The power cord and control wire can't be crossed or
blue black brown yellow- winding.
green
(2) The drain hose should be bound at the bottom.
Note:
Indoor Outdoor
(1) All wires of indoor unit and outdoor unit should be
Wall pipe Fig.17
connected by a professional. Sealing gum Upper hook
(2) If the length of power connection wire is insufficient, please
contact the supplier for a new one. Avoid extending the wire by
yourself.
(3) For the air conditioner with plug, the plug should be
reachable after finishing installation.
(4) For the air conditioner without plug, an air switch must be Fig.16 Lower hook of
wall-mounting frame
installed in the line. The air switch should be all-pole parting
and the contact parting distance should be more than 3mm. Note:
Do not bend the drain hose too excessively in order to prevent
blocking.
8.6 Installation of Outdoor Unit (3) Pretightening the union nut with hand.
(4) Tighten the union nut with torque wrench .
1. Fix the Support of Outdoor Unit(Select it according to
Refer to the following table for wrench moment of force:
the actual installation situation)
(1) Select installation location according to the house structure.
Hex nut diameter(mm) Tightening torque(N.m)
(2) Fix the support of outdoor unit on the selected location with
Φ6 15~20
expansion screws.
Φ9.52 30~40
Note: Φ12 45~55
(1) Take sufficient protective measures when installing the Φ16 60~65
outdoor unit. Φ19 70~75
(2) Make sure the support can withstand at least four times the
unit weight. 5. Connect Outdoor Electric Wire
(3) The outdoor unit should be installed at least 3cm above the (1) Remove the wire clip; connect the power connection wire
floor in order to install drain joint.(As show in Fig.18) and signal control wire (only for cooling and heating unit) to the
(4) For the unit with cooling capacity of 2300W~5000W, 6 wiring terminal according to the color; fix them with screws.(As
expansion screws are needed; for the unit with cooling capacity show in Fig.23)
of 6000W~8000W, 8 expansion screws are needed; for the Handle
unit with cooling capacity of 10000W~16000W, 10 expansion 1
screws are needed. Fig.23 1 /
%1
<(*1 %. <(*1
%8 %. %1 %8
32:(5
,1'22581,7 1 /
Drain vent Chassis Note: the wiring connect is for reference only,
Outdoor drain joint please refer to the actual one.
Drain hose
At least 3cm above the floor
Fig.18 Fig.19
(2) Fix the power connection wire and signal control wire with
2. Install Drain Joint(Only for cooling and heating unit) wire clip.
(1) Connect the outdoor drain joint into the hole on the chassis.
Note:
(2) Connect the drain hose into the drain vent.
(As show in Fig.19) (1) After tightening the screw, pull the power cord slightly to
check if it is firm.
3. Fix Outdoor Unit (2) Never cut the power connection wire to prolong or shorten
(1) Place the outdoor unit on the support. the distance.
(2) Fix the foot holes of outdoor unit with bolts. (As show in
Fig.20) 6. Neaten the Pipes
(1) The pipes should be placed along the wall, bent reasonably
Foot holes Handle and hidden possibly. Min. semidiameter of bending the pipe is
10cm.
(2) If the outdoor unit is higher than the wall hole, you must set
a U-shaped curve in the pipe before pipe goes into the room,
in order to prevent rain from getting into the room.(As show in
Foot holes Fig.24)
Fig.21 Valve cover
Fig.20
The drain hos
4. Connect Indoor and Outdoor Pipes can't raise
upwards
(1) Remove the screw on the handle and valve cover of outdoor
unit and then remove the handle and valve cover.(As show in
Fig.21) Wall
(2) Remove the screw cap of valve and aim the pipe joint at the
bellmouth of pipe.(As show in Fig.22) Fig.25
U-shaped curve
Fig.24
Liquid pipe Pipe joint
Drain hose
Liquid gas pipe
valve
Union nut
gas valve
Fig.22
1 Swing function
2 Air exchange function (this function is yet unavailable for this unit)
3 Sleep function (Only sleep 1)
4 Each kind of running mode of indoor unit (auto mode)
5 Cooling mode
6 Dry mode
7 Fan mode
8 Heating mode
9 Defrosting function for the outdoor unit
10 Gate-control function (this function is yet unavailable for this unit)
11 Lock function
Shield functions (Button operation, temperature setting, On/Off operation,Mode setting are
12 SHIELD
disabled by the remote monitoring system.)
13 TURBO Turbo function state
Memory function (The indoor unit resumes the original setting state after power failure and
14 MEMORY
then power recovery)
15 It blinks under on state of the unit without operation of any button
16 SAVE Energy-saving function
17 Ambient/setting temperature value
18 E-HEATER Electric auxiliary heating function(this function is yet unavailable for this unit)
19 BLOW Blow function
20 Timing value
21 QUIET Quiet function (two types: quiet and auto quiet)(this function is yet unavailable for this unit).
2 Buttons
2.1 Layout of Buttons
3 Operation Instructions
3.1 On/Off
Press On/Off to turn on the unit and turn it off by another press.
Note: The state shown in Fig.3.1.1 indicates the “Off” state of the unit after power on. The state shown in Fig.3.1.2 indicates the “On”
state of the unit after power on.
3.3 Temperature Setting
Press ▲or ▼ to increase/decrease the preset temperature. If pressing either of them continuously, the temperature will be increased or
decreased by 1°C every 0.5s,as shown in Fig.3.3.1.
In the Cooling, Dry, Fan or Heating mode, the temperature setting range is 16~30°C(61~86°F).
In the Auto mode, the setting temperature is unadjustable.
Fig.3.3.1 Fig.3.4.1
3.4 Fan Setting
Under the “On” state of the unit, press Fan and then fan speed of the indoor unit will change circularly as shown in Fig.3.4.1.
Low Middle High
Turn on the unit,without Timer Press Timer repeatedly unitll go Press ▲/▼ to adjust the time
activated to the setting status
Press Timer to cancel this setting Press Enter/Cancel to confirm this setting
Fig.3.5.1 Timer off Setting under the “On” State of the Unit
Timer on setting under the “Off” state of the unit is shown as Fig.3.5.2.
Turn off the unit,without Timer Press Timer repeatedly unitll go Press ▲/▼ to adjust the time
activated to the setting status
Press Timer to cancel this setting Press Enter/Cancel to confirm this setting
Fig.3.5.2 Timer on Setting under the “Off” State of the Unit
Timer range: 0.5-24hr. Every press of ▲or ▼ will make the set time increased or decreased by 0.5hr. If either of them is pressed
continuously, the set time will increase/ decrease by 0.5hr every 0.5s.
Turn off the unit,without Swing Press Function repeatedly unitll Press Enter/Cancel to activated the Swing
function activated go to the Swing setting status function
Notes:
(1)Sleep, Turbo or Blow setting is the same as the Swing setting.
(2)After the setting has been done, it has to press the key “Enter/Cancel” to back to the setting status or quit automatically five seconds
later.
Turn off the unit,without Sleep Press Function repeatedly unitll Press Enter/Cancel to activated the Sleep
function activated go to the Sleep setting status function
Turn off the unit,without Turbo Press Function repeatedly unitll Press Enter/Cancel to activated the Turbo
function activated go to the Turbo setting status function
Turn off the unit,without E-heater Press Function repeatedly unitll Press Enter/Cancel to activated the E-heater
function activated go to the E-heater setting status function
Turn off the unit,without Blow Press Function repeatedly unitll Press Enter/Cancel to activated the Blow
function activated go to the Blow setting status function
Notes:
(1)When the Blow function is activated, if turning off the unit by pressing On/Off or by the remote controller, the indoor fan will run at the
low fan speed for 2 min, with “BLOW” displayed on the LCD. While, if the Blow function is deactivated, the indoor fan will be turned off
directly.
(2)Blow function is unavailable in the Fan or Heating mode.
PVC Pipe
1 2 3 4 5
No. 1 2 3 4 5
Socket box embedded Soleplate of the Wired Front Panel of the
Name Screw M4X25 Screw ST 2.9X6
in the wall Controller Wired Controller
1 2 3 4
6 5
7
Fig.4.2
8 9 10
Fig.4.2
Fig.4.2 shows the installation steps of the wired controller, but there are some issues that need your attention.
(1) Prior to the installation, please firstly cut off the power supply of the wire buried in the installation hole, that is, no operation is allowed
with electricity during the whole installation.
(2) Pull out the four-core twisted pair line from the installation holes and then let it go through the rectangular hole behind the soleplate of
the wired controller.
(3) Stick the soleplate of the wire controller to the wall over the installation hole and then fix it with screws M4X25.
(4) Insert the four-core twisted pair line into the slot of the wired controller and then buckle the front panel and the soleplate of the wired
controller together.
(5) Finally, fix the front panel and the soleplate of the wired controller tightly by screws ST2.9X6.
CAUTION!
Please pay special attention to the followings during the connection to avoid the malfunction of the air conditioning unit due to
electromagnetic interference.
(1) Separate the signal and communication lines of the wired controller from the power cord and connection lines between the indoor and
outdoor unit, with a minimum interval of 20cm, otherwise the communication of the unit will probably work abnormally.
(2) If the air conditioning unit is installed where is vulnerable to electromagnetic interference,then the signal and communication lines of
the wired controller must be the shielding twisted pair lines.
5 Errors Display
If there is an error occurring during the operation of the system, the error code will be displayed on the LCD, as show in Fig.5.1. If multi
errors occur at the same time, their codes will be displayed circularly.
Note: In event of any error, please turn off the unit and contact the professionally skilled personnel.
Fig.5.1
9. Maintenance
9.1 Error Code List
Display Method of Indoor Unit
Compressor
Min Showing during min. cooling or
23 P0
frequence in min. heating test
test state
Compresso r
rated Showing during nominal cooling or
24 P1
frequenc e in nominal heating test
test state
Compressor
maximum Showing during max. cooling or
25 P2
frequence in max. heating test
test state
Compressor
intermediate Showing during middle cooling or
26 P3
frequence in middle heating test
test state
Static
32 dedusting H2
protection
Indoor unit
compressor and Outdoor fan Indoor unit and outdoor unit doesn't
and outdoor LP
motor can’t work match
41 unit doesn't
match
During cooling and drying
operation, compressor will stop
Failure start- while indoor fan will operate;
42 LC Refer to the malfunction analysis
up During heating operation, the
complete unit will stop
operation.
Frequency
48 limiting
(power)
49 Compressor
running
The
temperature
50 for turning
on the unit is
reached
Frequency
limiting
51
(module
temperature)
Normal
52 communica-
tion
Malfunction
of zero-cross 1.Power supply is abnormal;
54 detection U8 The complete unit stops 2.Detection circuit of indoor
circuit control mainboard is abnormal.
Malfunction
55 of detecting JF
plate(WIFI )
No
No Is malfunction
eliminated
No
No Is malfunction Yes
eliminated
Replace it with a
temperature sensor with
the same model
Yes
No Is malfunction
eliminated
Yes
End
Start
Turn unit on
Yes to check whether the
No malfunction is
eliminated.
Turn unit on
No No to check whether the Yes
malfunction is
eliminated.
Connect power and restart the unit. It's the malfunction of main board.
Test whether the voltage between terminal 1 and terminal 2 No Replace a new main board that is
of motor interface is within 280~310VDC. of the same model.
Yes
Yes
Then check whether the voltage It's the malfunction of main board.
between terminal 2 and terminal 3 No Replace a new main board that is
of the same model.
of the motor interface is 15VDC.
Yes
Then check whether there is voltage It's the malfunction of main board.
between terminal 2 and terminal 4 No Replace a new main board that is
of the motor interface. of the same model.
Yes
Start
No Appearance of the
Is there jumper cap on the mainboard?
jumper cap
No Is malfunction
eliminated
No Is malfunction Yes
eliminated
Is malfunction Yes
eliminated
Yes
No
End
Start
No No
Is the supply voltage too low Yes Adjust the supply voltage to maintain it Is malfunction Yes
with overload? within normal range eliminated
No No
Is the indoor / outdoor Yes Clean the indoor and outdoor heat Is malfunction Yes
heat exchanger dirty,or are the air inlet exchangers and remove the blockage eliminated
and outlet blocked? of air inlet and outlet
No
No
The fan is abnormal? Fan Yes Check the motor and reinstall the Is malfunction Yes
speed is too low or fan doesn’t rotate motor to have the fan run normally eliminated
No No
Yes No
Is there blockage inside the system? Yes Flush the heat exchangers with high
(Filth blockage, ice plug, greasy Is malfunction Yes
blockage, the cut off valve hasn’t been pressure nitrogen eliminated
opened completely)
No No
No
End
5. Communication Malfunction E6
Start
Yes
No
Yes
No
Replace
Communication cord is damaged? Yes communication Malfunction eliminated? Yes
cord
No
No
Replace IDU's
main board
Yes
Replace ODU's
Malfunction eliminated? No
main board.
Yes
End
Start
Yes
End
Start
Yes
Is malfunction
eliminated
The end
Outdoor Unit
1. Capacity charging malfunction (outdoor unit malfunction) (AP1 below means control board of outdoor unit)
Main detection points:
● Detect if the voltage of L and N terminal of XT wiring board is between 210VAC-240VAC by alternating voltage meter;
● Is reactor (L) well connected? Is connection wire loosened or pulled out? Is reactor (L) damaged?
Malfunction of
Voltage higher Replace outdoor
Y the outdoor
than 200V? mainboard
mainboard AP1
Power supply is
abnormal; repair
Voltage within the power supply Power on and
N Is the Vmalfunction Y
180VAC~260VAC? to restore the range restart the unit
eliminated?
between 180VAC
~260VAC
Y
Connect the
If the wiring of connection Power on and
N Is the Vmalfunction Y
reactor L is normal? wire of reactor restart the unit
eliminated?
L correctly
Replace outdoor
mainboard AP1 N
End
2. IPM protection(H5), desynchronizing malfunction(H7), overcurrent of compressor phase current (P5) (AP1 below means
control board of outdoor unit)
Main detection points:
● Is voltage input within the normal range
● If the control board AP1 is well connected with compressor COMP? If they are loosened? If the connection sequence is correct?
● Heat exchange of unit is not good (heat exchanger is dirty and unit radiating environment is bad);
● If the system pressure is too high?
● If the refrigerant charging amount is appropriate?
● If coil resistance of compressor is normal? Is compressor coil insulating to copper pipe well?
● If the work load of unit is heavy? If radiating of unit is good?
Malfunction diagnosis process:
H5, H7 or P5 is
displayed after
turning on the unit
Y
N
Y
N
N
N
Replace compressor
End
3. High temperature and overload protection (E8)(AP1 below means control board of outdoor unit)
Main detection points:
● If the outdoor ambient temperature is in normal range;
● If the indoor and outdoor fan are running normally;
● If the radiating environment of indoor and outdoor unit is good.
E8 is displayed
N N
N
N
Y
Y
Replace Fan
Fan capacitor is broken? Y
capacitor
Replace outdoor
mainboard
N
Replace mainboard
End
4. Start-up failure (LC) (AP1 below means control board of outdoor unit)
Main detection points:
● If the compressor wiring is correct?
● If the stop time of compressor is sufficient?
● If the compressor is damaged?
● If the refrigerant charging amount is too much?
Replace outdoor
mainboard AP1
Is the malfunction
eliminated?
Replace the
compressor
End
H3 or E4 is displayed
No
Yes
Yes
Connect wire
If the wiring terminal FA of electronic according to wiring
No
expansion valve is well connected? diagram
No
Yes
No
No
No
Heat exchange of unit is not good (heat exchanger
is dirty and unit radiating environment is bad); Is the malfunction Y
Yes
improve the radiating environment and clean the eliminated?
heat exchanger
No
No
Replace outdoor
mainboard AP1
End
start
No
No
No
Replace outdoor
N
No
mainboard AP1
End
E6
No
No
Yes
Yes
Yes End
15
35 36 37 39 14
34
13
12
FAN
16
MODE
ON/OFF
11 17
10 18
9
8
7
6
5
19
4
3 20
2 21
24
1 22
25
26
27
28
23 29
30
38
31
32
33
The component picture is only for reference; please refer to the actual product.
Part Code
Description
No. GWH09YD-S6DBA2A/I GWH12YD-S6DBA2A/I Qty
Product Code CB466N00100 CB466N00200
1 Front Panel 00000300008303 00000300008303 1
2 Filter Sub-Assy 11122089 11122089 2
3 Front Case Sub-Assy 00000200060 00000200060 1
4 Axile Bush 10542036 10542036 2
5 Guide Louver 10512501 10512501 1
6 Ring of Bearing 26152025 26152025 1
7 O-Gasket of Cross Fan Bearing 76512203 76512203 1
8 Cross Flow Fan 10352060 10352060 1
9 Air Louver(Manual) 10512501 10512501 1
10 Helicoid Tongue 26112512 26112512 1
11 Rear Case assy 00000100177 00000100177 1
12 Evaporator Support 24212177 24212177 1
13 Evaporator Assy 011001000472 011001000472 1
14 Wall Mounting Frame 01362026 01362026 1
15 Drainage Hose 05230014 05230014 1
16 Cold Plasma Generator 1114001602 1114001602 1
17 Rubber Plug (Water Tray) 76712012 76712012 1
18 Connecting pipe clamp 2611218801 2611218801 1
19 Crank 73012005 73012005 1
20 Stepping Motor 1521240212/1521210704 1521240212/1521210704 1
21 Motor Press Plate 26112511 26112511 1
22 Fan Motor 15012136 15012136 1
23 Screw Cover 2425201726 2425201726 3
24 Electric Box Assy 100002000983 100002000983 1
25 Electric Box 2011221102 2011221102 1
26 Lower Shield of Electric Box 01592139 01592139 1
27 Shield Cover of Electric Box 01592176 01592176 1
28 Display Board 300001000095 300001000095 1
29 Main Board 300002000101 300002000101 1
30 Terminal Board 42011233 42011233 1
31 Electric Box Cover 20112209 20112209 1
32 Electric Box Cover2 20112210 20112210 1
33 Shield Cover of Electric Box Cover 2 01202000099 01202000099 1
34 Connecting Cable 4002052317 4002052317 0
35 Connecting Cable / / /
36 Temperature Sensor 3900031302 3900031302 1
37 Remote Controller 30510137 30510137 1
38 Jumper 4202021911 4202021911 1
39 Detecting Plate 000409000001 000409000001 1
Part Code
Description
No. GWH09YD-S6DBA2A/I Qty
Product Code CB466N00102
1 Front Panel 00000300008303 1
2 Filter Sub-Assy 11122089 2
3 Front Case Sub-Assy 00000200060 1
4 Axile Bush 10542036 2
5 Guide Louver 10512501 1
6 Ring of Bearing 26152025 1
7 O-Gasket of Cross Fan Bearing 76512203 1
8 Cross Flow Fan 10352060 1
9 Air Louver(Manual) 10512501 1
10 Helicoid Tongue 26112512 1
11 Rear Case assy 00000100177 1
12 Evaporator Support 24212177 1
13 Evaporator Assy 011001000472 1
14 Wall Mounting Frame 01362026 1
15 Drainage Hose 05230014 1
16 Cold Plasma Generator 1114001602 1
17 Rubber Plug (Water Tray) 76712012 1
18 Connecting pipe clamp 2611218801 1
19 Crank 73012005 1
20 Stepping Motor 1521240212 1
21 Motor Press Plate 26112511 1
22 Fan Motor 15012136 1
23 Screw Cover 2425201726 3
24 Electric Box Assy 100002004024 1
25 Electric Box 2011221102 1
26 Lower Shield of Electric Box 01592139 1
27 Shield Cover of Electric Box 01592176 1
28 Display Board 300001000095 1
29 Main Board 300002000858 1
30 Terminal Board 42011233 1
31 Electric Box Cover 20112209 1
32 Electric Box Cover2 20112210 1
33 Shield Cover of Electric Box Cover 2 01202000099 1
34 Connecting Cable 4002052317 0
35 Connecting Cable / /
36 Temperature Sensor 3900031302 1
37 Remote Controller 305001000139 1
38 Jumper 4202021911 1
39 Detecting Plate 000409000001 1
The component picture is only for reference; please refer to the actual product.
Part Code
Description
No. GWH09YD-S6DBA2A/O GWH12YD-S6DBA2A/O Qty
Product Code CB466W00100 CB466W00200
1 Front Grill 22413046 22413046 1
2 Cabinet 01433034P 01433034P 1
3 Axial Flow Fan 10333011 10333011 /
4 Brushless DC Motor 1501308511 1501308511 1
5 Clapboard Sub-Assy 01235094 01235094 1
6 Left Side Plate 01303169P 01303169P 1
7 Valve Cover 22243005 22243005 1
8 Main Board 300027000056 300027000056 1
9 Electric Box Assy 100002000997 100002000997 2
10 Coping 01253034P 01253034P 1
11 Rear Grill 01475022 01475022 1
12 Condenser Assy 011002000422 011002000422 1
13 Compressor and Fittings 00900100022901 00900100022901 1
14 4-Way Valve Assy 030152000214 030152000214 1
15 Cut off Valve 07130239 07130239 1
16 Cut off Valve 071302391 071302391 1
17 Drainage Joint 26113009 26113009 1
18 Big Handle 2623343106 2623343106 1
19 Valve Support Sub-Assy 01710400005P 01710400005P 1
Step Procedure
1.Remove filter
Horizontal louver
Step Procedure
Groove
Screw
Vertical louver
Loosen the connection clasps between
vertical louver and bottom case to
remove vertical louver.
Clasps
Step Procedure
Wiring terminal
Pull out the wiring terminal of motor and
of motor
wiring terminal of step motor from the
mainboard.
Note:
When pulling out the wiring terminal,
pay attention to loose the clasp and don’t
pull it so hard. Wiring terminal
of step motor
Step Procedure
Screw
Connection pipe
Screws
Step motor
Step Procedure
Motor clamp
a. Remove the screws fixing motor clamp Screws
and then remove the motor clamp.
Screw Motor
Cross flow
Holder sub-assy
1. Before disassembly
3. Remove handle
handle
panel
grille
valve cover
electric
reactor
motor support
motor
mid-isolation board
compressor
Remove the three feet screw nuts fixing compressor,
to remove the compressor.
big valve
condenser assy
Appendix:
Appendix 1: Reference Sheet of Celsius and Fahrenheit
Conversion formula for Fahrenheit degree and Celsius degree: Tf=Tcx1.8+32
Set temperature
Fahrenheit Fahrenheit Fahrenheit
display Fahrenheit display Fahrenheit display Fahrenheit
Celsius(°C) Celsius(°C) Celsius(°C)
temperature (°F) temperature (°F) temperature (°F)
(°F) (°F) (°F)
61 60.8 16 69/70 69.8 21 78/79 78.8 26
62/63 62.6 17 71/72 71.6 22 80/81 80.6 27
64/65 64.4 18 73/74 73.4 23 82/83 82.4 28
66/67 66.2 19 75/76 75.2 24 84/85 84.2 29
68 68 20 77 77 25 86 86 30
Ambient temperature
Fahrenheit Fahrenheit Fahrenheit
display Fahrenheit display Fahrenheit display Fahrenheit
Celsius(°C) Celsius(°C) Celsius(°C)
temperature (°F) temperature (°F) temperature (°F)
(°F) (°F) (°F)
32/33 32 0 55/56 55.4 13 79/80 78.8 26
34/35 33.8 1 57/58 57.2 14 81 80.6 27
36 35.6 2 59/60 59 15 82/83 82.4 28
37/38 37.4 3 61/62 60.8 16 84/85 84.2 29
39/40 39.2 4 63 62.6 17 86/87 86 30
41/42 41 5 64/65 64.4 18 88/89 87.8 31
43/44 42.8 6 66/67 66.2 19 90 89.6 32
45 44.6 7 68/69 68 20 91/92 91.4 33
46/47 46.4 8 70/71 69.8 21 93/94 93.2 34
48/49 48.2 9 72 71.6 22 95/96 95 35
50/51 50 10 73/74 73.4 23 97/98 96.8 36
52/53 51.8 11 75/76 75.2 24 99 98.6 37
54 53.6 12 77/78 77 25
Note: The additional refrigerant charging amount in Sheet 2 is recommendedvalue, not compulsory.
Improper pipe expanding is the main cause of refrigerant leakage.Please Pipe cutter
expand the pipe according to the following steps:
Leaning Uneven Burr
A:Cut the pip
● Confirm the pipe length according to the distance of indoor unit and outdoor unit.
● Cut the required pipe with pipe cutter.
● Remove the burrs with shaper and prevent the burrs from getting into the pipe. Shaper
Downwards
C:Put on suitable insulating pipe
Smooth surface
F:Inspection
● Check the quality of expanding port. If there is any blemish, expand the
Improper expanding
port again according to the steps above.
Resistance Table of Ambient Temperature Sensor for Indoor and Outdoor (15K)
Resistance Table of Tube Temperature Sensors for Indoor and Outdoor (20K)