DASAN V5816 DataSheet EN
DASAN V5816 DataSheet EN
DASAN V5816 DataSheet EN
Product Overview
Operating Status LEDs
Plug-In Units
Service Scenario
Product Specifications
System features
Capabilities
Physical Specifications
Connector Specifications
Product Overview
V5816 can be used as a GPON Optical Line Termination (OLT) supporting 16-Port GPON
interfaces as well as L3 switch of supporting 4-Port 1/10GBase-R (SFP+) 10 Gigabit Ether-
net and 4-Port 10/100/1000Base-T(RJ45) Gigabit Ethernet service. It terminates the traffic
coming from the subscriber lines and consolidates it on one or more Gigabit Ethernet inter-
faces towards the metropolitan area.
The GPON technology adds new features and functionality targeted at improving perfor-
mance and interoperability, and adds support for new applications, services, and deploy-
ment scenarios. Among these changes are improvements in data rate and reach perfor-
mance, diagnostics, and stand-by mode, to name a few.
The V5816 introduces a point-to-multipoint concept with the GPON technology, which ena-
bles a cost-effective FTTx service. The reason why GPON is considered as a cost-effective
solution is its usage of a passive splitter rather than an active switching system.
The V5816 has two Power Supply Unit (PSU) mounting slots on the front panel. Each PSU
is comprised of single power input. For power redundancy, user can equip dual PSUs into
2-slot.
V1.0 Page 1 of 15
Data Sheet – V5816
The V5816 provides 16 GPON ports on the front panel, each delivering 2.488Gbps down-
stream and 1.244Gbps upstream. Each GPON port supports a pluggable SFP laser module
that allows selection of the best speed and power to meet network requirements. It is com-
prised of 4 optical 10 GE interfaces and 4 optical 1 GE interface as uplink towards the core
network and these interfaces can be used either to cascade other switches. The MGMT and
console interface is located on the most left of the front panel with embedded LED for
LNK/ACT and TX/RX indication respectively. They are for use of equipment management
via remote access or CLI.
① FAN 2 FAN-Module
V1.0 Page 3 of 15
Data Sheet – V5816
The V5816 is equipped with a LED to indicate the status of power. The meaning of the LED
is shown in below table.
The V5816 is equipped with two LEDs to indicate the operating status of the unit. The
meaning of the LEDs is shown in below table.
On the rear panel of the switch, there are two slots for Power Supply Unit (PSU). The
mounting slots can be equipped with DC or AC type PSUs. The different type of PSUs can
be equipped into the switch. The below table shows DC type of power supply modules.
Two PSUs are displayed with two LEDs to indicate the status of the power feeding and error.
The meaning of the LEDs is shown in below table.
Two Fan units are displayed two LEDs to indicate the status of normal operation and Error
situation. The meaning of the LED is shown in below table.
V1.0 Page 5 of 15
Data Sheet – V5816
The V5816 also uses LED to indicate the status of each GPON interface and 1GE interface
and 10GE interface (port 1 to 24). These LEDs are used for link status information such as
link integrity, traffic activity, and transmit rate. The meaning of the LEDs is shown in the be-
low.
L/A Green On The port link is up and the Ethernet transmit rate is 10Gbps.
Blinking A transmit or receive activity is present on the Ethernet port at 10Gbps
transmit rate.
Amber On The port link is up and the Ethernet transmit rate is 1Gbps.
Blinking A transmit or receive activity is present on the Ethernet port at 1Gbps
transmit rate.
- Off The port link is down.
The MGMT interface connector includes two LEDs to indicate the status of the MGMT inter-
face, see the below table. The meaning of the LEDs is shown in below table.
The console interface connector includes two LEDs to indicate the status of the console in-
terface, the meaning of LEDs is shown in below table.
V1.0 Page 7 of 15
Data Sheet – V5816
Plug-In Units
On the front panel of the switch, there are two slots for Power Supply Unit (PSU). The
mounting slots can be equipped with DC or AC type PSUs. The different type of PSUs can
be equipped into the switch. The below shows AC and DC type of power supply modules
Two PSUs, supply power to the switch, are regulated first through the each SMPS or
DC/DC converter. For supplying redundancy, dual PSUs have to be installed at a system.
The power supply unit (PSU) feeds the proper power voltage to the base board of V5816.
Two PSUs are possible to be mounted into front side of the chassis and it can be DC or AC
type of PSU. Therefore, you need to decide to choose proper power supply unit according
to installation environment.
The power connector (AC and DC type) for main power supply is located on the front panel
of the PSU. For redundant power feeding, the second PSU has to be used.
Characteristic V5816
The DC power connector (DC type) or AC power connector (AC type) for main power sup-
ply is located on the front panel of the PSU. For redundant power feeding, the second PSU
has to be used.
FAN Unit
The V5816 provides 2 fan unit slots on the rear panel. This plug-in unit internally consists of
2 fans. User can insert fan unit to a fan slot by slowly adjusting them to fit into the slot guid-
ance. The air flows from the front side inlet to the rear side outlet.
V1.0 Page 9 of 15
Data Sheet – V5816
Service Scenario
A PON consists of an Optical Line Termination (OLT) located at the Central Office and a set
of Optical Network Units (ONUs) or Optical Network Terminals (ONTs) located at the cus-
tomer’s premises. Between them is the optical distribution network (ODN) comprising of fi-
bers and passive optical splitters or couplers. A splitter is a device that divides an optical
signal into two or more signals. OLT connects the PON to the IP network, controls and
manages the PON clients. ONU (ONT) connects the user specific network to PON. The
ONT can be occupied by a single subscriber and also can be a gateway of the local net-
work.
The V5816 is a network element, which includes the necessary service adaptation functions
to support the delivery of all types multiple services, such as Ethernet, IP telephony, and
video services.
The V5816 GPON OLT system is one element of this end-to-end solution, however DASAN
Network Solutions is able to provide the complete next generation broadband access net-
work and video integration solution, where full interoperability is ensured. Up to 128 termi-
nation points for GPON can be attached to an OLT via passive optical splitter.
There are different possible deployment topologies for GPON networks, which differentiate
from each other basically from the place the optical fiber is terminated. Depending on the
subscriber type and desired topology to the network, the operator may adopt: FTTH (fiber to
the Home), FTTB (fiber to the Building), FTTN (fiber to the neighborhood) or FTTC (fiber to
the Curb). In case of very high bandwidth requirement per user, scenarios without splitters
offering 2.5Gbps/1.25Gbps (downstream/upstream) data rate can also be deployed by con-
necting only the single user on a GPON port.
Data Sheet – V5816
Product Specifications
System features
The V5816 supports the following system features:
Capabilities
The V5816 provides the following functionalities:
GPON
• Supports 4K port-ID
• Supports 1K alloc-ID
• Supports ITU-T G.984.4 OMCI
• Supports ITU-T G.984.3. amd2
Layer 2
• VLAN 4K
• Double IEEE802.1Q for stacking
• Spanning tree (PVRSTP, MSTP, STP/PVSTP+ compatible)
• Jumbo frame of up to 9KB
• Link Aggregation (Static and LACP)
Layer 3
Multicast
• IGMPv1/v2/v3 Snooping
• IGMPv1/v2 Proxy
• MLD snooping, MLD proxy
V1.0 Page 11 of 15
Data Sheet – V5816
ERPS
• G.8032
• Y.1731
• HW based CCM
QoS
Security
Management
• Serial/Telnet (CLI)
• SNMPv1/v2/v3
• RADIUS/TACACS authentication
• SSH
• Syslog (volatile, non-volatile, remote)
Data Sheet – V5816
Physical Specifications
V5816
Power Supply
Operating Indicators
Operating Indicators
V1.0 Page 13 of 15
Data Sheet – V5816
Connector Specifications
The V5816 provides standardized interfaces, thus facilitating rapid and trouble-free integra-
tion into the existing network infrastructures.
Service Interfaces
The V5816 contains 16 GPON interface ports for SFP modules and blow table is available
GPON module list.
Network Interfaces
The V5816 contains 4 optical interface ports for SFP/SFP+ modules and blow table is avail-
able SFP/SFP+ module list.
SFP-GE-SX SFP GE SX
- Wavelength: 850 nm / Distance: 550 m / Mode: multi-mode
- Connector: LC / Data rate: 1.25Gbit/s / Core type: Dual Core
- Operating Temperature: 0 °C - 70 °C
SFP-GE-LX5 SFP GE LX5
-. Wavelength: 1310nm / Distance: 5km / Mode: single-mode
-. Connector: LC / Data rate: 1.25Gbit/s / Core type: Dual Core
-. Operating Temperature : 0 °C – 70 °C
SFP-GE-LX10 SFP GE LX10
- Wavelength: 1310 nm / Distance: 10 km / Mode: single-mode
- Connector: LC / Data rate: 1.25 Gbit/s / Core type: Dual Core
- Operating Temperature: 0 °C – 70 °C
SFP-GE-LX15 SFP GE LX15
- Wavelength: 1310 nm / Distance: 15 km / Mode: single-mode
- Connector: LC / Data rate: 1.25 Gbit/s / Core type: Dual Core
- Operating Temperature: 0 °C – 70 °C
SFP-GE-LX20 SFP GE LX20
- Wavelength: 1310 nm / Distance: 20 km / Mode: single-mode
- Connector: LC / Data rate: 1.25 Gbit/s / Core type: Dual Core
- Operating Temperature: 0 °C - 70 °C
SFP-GE-LX40 SFP GE LX40
- Wavelength: 1310 nm / Distance: 40 km / Mode: single-mode
- Connector: LC / Data rate: 1.25 Gbit/s / Core type: Dual Core
Data Sheet – V5816
- Operating Temperature: 0 °C - 70 °C
V1.0 Page 15 of 15