0% found this document useful (0 votes)
283 views17 pages

DASAN V5824G DataSheet EN

The document is a data sheet for the V5824G GPON OLT system from DASAN Networks. It has 8 GPON ports providing 2.488Gbps downstream and 1.244Gbps upstream data rates. It also includes 8 electrical or optical Gigabit Ethernet ports and 2 10GbE uplink ports. The OLT connects to optical network units via an optical distribution network using passive splitters, providing fiber connectivity for services like broadband internet, IP telephony and video to customers in a cost-effective manner.

Uploaded by

Rafal Z
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
283 views17 pages

DASAN V5824G DataSheet EN

The document is a data sheet for the V5824G GPON OLT system from DASAN Networks. It has 8 GPON ports providing 2.488Gbps downstream and 1.244Gbps upstream data rates. It also includes 8 electrical or optical Gigabit Ethernet ports and 2 10GbE uplink ports. The OLT connects to optical network units via an optical distribution network using passive splitters, providing fiber connectivity for services like broadband internet, IP telephony and video to customers in a cost-effective manner.

Uploaded by

Rafal Z
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 17

DATA SHEET

V5824G

GPON OLT
Data Sheet
V5824G

Issue History
Version Date of Issue Reason for Update
V1.0 11/2013 Initial release

v1.0 Page 2 of 17
Data Sheet
V5824G

1 Product Overview
With increasing internet users in thinly populated regions, the demand of high-bandwidth
and cost-effective systems for connecting to network has been existed in the market these
days. To meet these customer needs, DASAN Networks has launched V5824G GPON (Gi-
gabit Passive Optical Network) OLT system.

The V5824G is a compact sized 1RU GPON Optical Line Terminal (OLT) system. This sys-
tem is suitable for FTTx services to the areas that have a low density of population or a
small number of subscribers with less cost.

The V5824G provides 8 GPON ports on the front panel, each delivering 2.488Gbps down-
stream and 1.244Gbps upstream data rate. Each GPON port supports a pluggable SFP la-
ser module that allows selection of the best speed and power to meet network require-
ments. This OLT provides 8 electrical (RJ45) and optical (SFP) combo GE interfaces. And
two 10GE (SFP+) uplink ports as uplink towards the core network and these interfaces can
be used either to cascade other switches or to connect to a collocated DSLAM. The MGMT
and console interface is located on the most left of the front panel with embedded LED for
LNK/ACT and TX/RX indication respectively. They are for use of equipment management
via remote access or CLI.

It has the ability to support dual module-type PSUs (Power Supply Units) on the rear panel.
Reliable operation and service are guaranteed through power redundancy, which prevents
the system shutting down at the power-related failure.

The GPON technology adds new features and functionality targeted at improving perfor-
mance and interoperability, and adds support for new applications, services, and deploy-
ment scenarios. Among these changes are improvements in data rate and reach perfor-
mance, diagnostics, and stand-by mode, to name a few.

The V5824G introduces a point-to-multipoint concept with the GPON technology, which en-
ables a cost-effective FTTx service. The reason why GPON is considered as a cost-
effective solution is its usage of a passive splitter rather than an active switching system.

The benefits of the passive splitter are as follows:


• No power supply / maintenance is needed.
• The splitter does not need any fiber optic transceiver. The number of fiber optic
transceivers in the network is minimized.

v1.0 Page 3 of 17
Data Sheet
V5824G

1.1 Product Interface

Figure 1 Front View of V5824G

Item Function Connector Type

Operating LED Indicator for system operating status including power, fault detection -
and booting state.
CONSOLE CLI access to configure the functions for system operation RJ45 (RS232)
MGMT Out-of-band TMN-OS Interface RJ45
Subscriber i/f 8 x GPON ports SC/PC
Combo GE i/f 8 x 100/1000Base-X or 10/100/1000Base-T combo type ports SFP or RJ45
Uplink 10GE i/f 2 x 10GBase-R uplink ports SFP+

Table 1 Front Access Interfaces of V5824G

The dual power supply connectors are located on the rear panel.

Figure 2 Rear View of V5824G

Name Function Connector Type

Grounding Terminal Grounding the switch to avoid electric shock -


PSU module Mounting AC or DC type power module AC or DC

Table 2 Rear Interfaces of V5824G

v1.0 Page 4 of 17
Data Sheet
V5824G

1.2 Service Scenario


A PON consists of an Optical Line Termination (OLT) located at the Central Office and a set
of Optical Network Units (ONUs) or Optical Network Terminals (ONTs) located at the cus-
tomer’s premises. Between them is the optical distribution network (ODN) comprising of fi-
bers and passive optical splitters or couplers. A splitter is a device that divides an optical
signal into two or more signals. OLT connects the PON to the IP network, controls and
manages the PON clients. ONU (ONT) connects the user specific network to PON. The
ONT can be occupied by a single subscriber and also can be a gateway of the local net-
work.

Data
MDUs

Internet
Voice Passive
Optical Splitter OLT

ONUs
Video

Figure 3 Optical Distribution Network by PON Architecture

The V5824G is a network element, which includes the necessary service adaptation func-
tions to support the delivery of all types multiple services, such as Ethernet, IP telephony,
and video services.

The V5824G GPON OLT system is one element of this end-to-end solution, however Da-
san Networks is able to provide the complete next generation broadband access network
and video integration solution, where full interoperability is ensured. Up to 64 (max.128)
termination points for GPON can be attached to an OLT via passive optical splitter.

There are different possible deployment topologies for GPON networks, which differentiate
from each other basically from the place the optical fiber is terminated. Depending on the
subscriber type and desired topology to the network, the operator may adopt: FTTH (fiber
to the Home), FTTB (fiber to the Building), FTTN (fiber to the neighborhood) or FTTC (fiber
to the Curb). In case of very high bandwidth requirement per user, scenarios without split-
ters offering 2.5Gbps/1.25Gbps (downstream/upstream) data rate can also be deployed by
connecting only the single user on a GPON port.

v1.0 Page 5 of 17
Data Sheet
V5824G

Street Curb or
Cabinet
HDTV

Central Office
VoIP

Shelf-based
DSLAM PC

OLT FTTC / FTTN HDTV

VoIP

L3 Switch OLT ONT


PC

Server FTTH

VoIP

L2 Switch/
PC
MDU

FTTB

Figure 4 FTTx Service Deployments of GPON OLT

v1.0 Page 6 of 17
Data Sheet
V5824G

2 Product Specification

2.1 System Feature


The V5824G supports the following system features:

• 96Gbps switching capacity and 71Mpps throughput


• 8-port GPON subscriber interface:
– 8-port of GPON interfaces (SFP, SC/PC type)
• 8-port GE interface (Combo):
– 100/1000Base-X optical interfaces (SFP) or
– 10/100/1000Base-T electrical interfaces (RJ45)
• 2 uplink interface ports
– 2-port 1G/10GBase-R (SFP+)
• LED indicators
• 64MB Flash memory, 512MB DDR SDRAM
• Console command line interface (CLI) via RS232
• 1 FE interface for out-of-band management
• Redundant and load balanced plug-in Power Supply Unit (PSU)

2.2 SW Capabilities
System Performance

MAC Address

Max. MAC Addresses: 32K

Concurrent VLAN

Max. VLANs: 4K (1~4094) Up to 4K stacked VLANs

IP Scalability

Max. No. of L3 Route Entries IPv4, (IPv6) : 8K(4K)

Equipment Performance

Cold Startup Time: max. 2 min

Ethernet Functions

Ethernet Switching

Switching / Bridging acc. to 802.1D and 802.1Q Packet Format: Ethernet-II and 802.3

Address Learning with Auto Aging Jumbo Frames up to 9k

Configurable Aging Time Automatic and manual Auto-negotiation

Link Aggregation (Uplink)

Link Aggregation (LAG) acc. to 802.3ad No. of LAG Groups: 12

No. of LAG Ports per Group: 8

Link Aggregation Control Protocol (LACP)

MAC Address based LACP IP Packet based (Address based) LACP

VLAN Handling

v1.0 Page 7 of 17
Data Sheet
V5824G

Untagged Port Configuration VLAN can be set by Port

VLAN Tagging VLAN-ID can be set by IP TOS/DSCP

tagged and untagged frames at mixed at uplink port VLAN can be set by MAC Address List
(outgoing)

VLAN Duplication based on IGMP VLAN can be set by IP Source Address / Subnet

VLAN Stripping VLAN can be set by IP Destination Address / Sub-


net

Independent VLAN Learning (IVL) Tagged User Frames

Port Isolation

Hierarchical Functions

VLAN Stacking per port (.1Q in .1Q) Configurable Ethernet type for VLAN
(VLAN can be set by port)
VLAN Stacking (.1Q in .1Q) (single tagging / stripping)

Ethernet Multicast / Broadcast

Ethernet Multicast Configurable Limit for Multicast Traffic on Uplink


(with activation / deactivation possibility)

Block unknown Multicast Flow based on system Basis Configurable Limit for Broadcast Traffic on Uplink
(with activation / deactivation possibility)
Block unknown Multicast Flow based on port Basis

GPON Functions

GPON Basic Functions

ITU-T Rec. G.984.3 AMD 2 ITU-T G.984.4 ONT Management & Control
Interface (OMCI)
G-PON OLT compliant with ITU-T G.984 Automatic ONT ranging
1K of T-CONT ID 4K of GEM Port-ID

4K of MAC Entry Max Splitter Ratio : 128

Max Transmission Distance: 60km T-CONT Type (Type1 ~ Type5)

GPON Advanced Functions

Classification/Tagging per DSCP/COS FEC for Upstream/Downstream

Key-Exchange for Encryption ONU Auto-discovery

ONU Authentication ONU Encryption

ONU Upgrade Remote ONT/ONU management

IP Functions

IP Routing

IPv6 H/W ready IPv4 Routing

IP Forwarding (static routing) OSPF v2

BGP v4 VRRP

OSPF ECMP (equal cost multi-path protocol) Policy-based Routing

IP Multicasting

IGMP v1/v2 Snooping IGMP Filtering (filtering of join and leave messag-
es)
IGMP v1/v2 Snooping with single VLAN tagged IGMP Filtering and Throttling

v1.0 Page 8 of 17
Data Sheet
V5824G

IGMP v3 Snooping IGMP Proxy

IGMP v3 Snooping with single VLAN tagged IGMP Termination

IP Multicast Routing Protocols (PIM-SM) PIM-SSM(Source Specific Multicast)

CoS / QoS Functions

E2E CoS/QoS WRED Congestion Management

802.1p Strict Priority 8 queues per port

WRR HW-based internal Classes of Service (CoS)


DRR Ingress Policer per VLAN & port

QoS Mapping based on ingress Port ingress Policer Per VLAN per CoS

QoS Mapping based on 802.1q (VLAN tag) ingress Policer Per IP SA/DA

QoS Mapping based on 802.1p Priority ingress Policer Per DSCP

QoS Mapping based on IP TOS/DSCP Egress Shaper per Port

QoS Mapping based on IP DA/SA Policing in 128 Kbps, 256 Kbps and 512 Kbps up
to 1 Mbps Bit Rate

QoS Mapping based on L4 Info Minimum granularity at ingress and egress port:
64 kbit/s

CoS/802.1p Marking based on Ethertype Granularity per traffic class: 64 kbit/s

CoS/802.1p Marking based on IP SA Policing in 1 Mbps Steps up to 100 Mpbs Bit Rate

Tagging/Overwriting 802.1p acc. to QoS Mapping Policing in 10 Mbps Steps from 100 Mbps to 1
Gbps Bit Rate

Tagging/Overwriting TOS/DSCP to QoS Mapping Shaping, Policing, Classification, and Prioritization


acc. to IETF Diffserv RFC 2474

Traffic Protection (L2)

Load Sharing inside LAG Group IEEE 802.1s (MSTP)

IEEE 802.1D (STP) IEEE 802.1w (RSTP)

Service Layer

Service Types

Transparent Data Ethernet Services Transparent L2 Protocol Ethernet Services

Service Connectivity

Multiple Services on a single Customer Access Point-to-Multi-Point (via VLAN and SVLAN)

Point-to-Point (EVC) (via VLAN and SVLAN) Any-to-Any (LAN 802.1d bridge) (via VLAN and
SVLAN)
Multiplexed Point-to-Point (via VLAN and SVLAN) Uni- / Bi-directional (via VLAN and SVLAN)

Multipoint to Multipoint (EVC) (via VLAN and SVLAN) Asymmetrical / symmetrical BW Assignment (via
VLAN and SVLAN)
Multiplex Multipoint to Multipoint (EVC) (via VLAN and DHCP Relay Agent Option 82 for User Traffic
SVLAN)
Security Services for Traffic Interfaces

Access Control List (ACL) based on Port Port based Authentication acc. to 802.1x for Traffic
Interfaces

ACL based on MAC Addresses MAC based Authentication acc. to 802.1x for Traf-
fic Interfaces
ACL based on Ether Type Anti-spoofing Mechanism

v1.0 Page 9 of 17
Data Sheet
V5824G

ACL based on IP SA/DA Storm Control

ACL (for IGMP) based on IP Multicast Address (mul- DHCP Filtering


ticast filtering)

ACL based on L4 Check IP/MAC Address provided by DHCP Relay


Agent

Blocking of STP BPDUs at ingress Suppression of Broadcast & Multicast Frames

Limit Number of MAC Addresses per any Kind of Port

Management & Control

TMN Embedding

Element Management by CLI

Management Interfaces - Layer 1 - 4

Out-of-band RS232 with 9600 Baud Rate DHCP Server

Loopback IP Address per Switch DHCP Option82

Dynamic ARP DHCP Simplified Option82

Static Routing Table DHCP Snoop

Support of static IP Addresses DHCP Simplified Relay Agent

DHCP Client DHCP Relay Agent

Management Interfaces - Layer 5 - 7

CLI ICMP RFC 792

SNMP v1/v2 Telnet Server

SNMP v3 SNTP Client V3 RFC 2030

GUI-based Management

Security

Disable / Enable in-band Management Traffic for a SSH and SNMPv3


given Port
Password Management for NE User Password must be stored in an encrypted
Mode

3 Levels of Access privileged 2 Levels of Community Strings

2 Levels of Access privileged SSH v1/v2

MIBs

Same Set of Standard MIBs for all NE DASAN IGMP SNOOPING MIB

Configuration Database / Log

Current Configuration File Manual Reset of Configuration Log

Retrieval of all historical Configuration Log Entries Restore of Database Backup File

Accuracy of Event Processing

Time Stamping Accuracy of 1s

Fault Monitoring & Handling

Alarm level: Alarm information:


- Critical Alarm - Name of the Object
- Major Alarm - Severity
- Minor Alarm - Day and Hour of the Event
- Alarm of Information - Description of the Event
- State of the Event

v1.0 Page 10 of 17
Data Sheet
V5824G

Monitoring acc. to the related MIBs for each Technol-


ogy (Excluding RPR)

Performance & Traffic Related Alarms

Link State up/down Resource Threshold

Alarm Event Filtering

Filter outgoing alarms acc. to precedence

Alarm Thresholds

Threshold for Traffic Counters and Resource Status

Equipment Related Fault Types

Temperature of the Chassis Threshold Fan Failure

Fault Log

Retrieval of all current Transmission / Equipment Log Files for Events and Alarms
Alarm Entries (Using syslog)
Alarm Log Size of (at least) 500 Entries using FIFO Manual Reset of entire historical Alarm Log
Principle
Retrieval of all historical Alarm Log Entries

Performance Monitoring & Handling

24 Hour Interval Counters 15 min Data Information polled by TMN

15 min Interval Counters 15 Min Data Storage for 24H

Free-running Counters 24 Data Storage for 2 days

Ethernet Performance Monitoring

Packet Counting No. of Bytes per Port

Packets per Port Errors acc. to MIB (CRC, truncated, etc)

Drop Packets per Port/CoS

Maintenance, Supervision & Diagnostics

Transmission Diagnostics - Monitor Points

Port Mirroring Service Mirroring

Transmission Diagnostics - LEDs Supervision

LED Indication of Power Status LED Indication of Port Activity per Port

LED Indication of Equipment Failure Status (e.g. fan) Temperature Sensor

Transmission Diagnostics - Self Monitoring / Diagnostic Functions

Power up Self Test Watch Dog Function for autonomous SW Reset

Equipment Diagnostics

Error messages must be easy to read and self- HW Fault Indication down to individual in-field
explanatory. exchangeable Module / card
Monitoring of CPU, Memory and Overload

Equipment Inventory

Factory Module Label in non-volatile Memory Automatic Detection of SFPs capability

Standard Compliance

Layer 2 - Switching

IEEE 802.1d. Local and Metropolitan Area Networks - IEEE 802.1x (Authentication)
Media Access Control (MAC) Bridges

v1.0 Page 11 of 17
Data Sheet
V5824G

IEEE 802.1q IEEE 802.3

RFC 826 ARP IEEE 802.3x Flow Control

IEEE 802.1v (VLAN Classification by protocol and


port)

Layer 3 - Routing

RFC 2328 OSPF v2 (including MDS authentication) RFC 1587 OSPF NSSA Option

RFC 1765 OSPF Database Overflow RFC 2370 OSPF Opaque LSA Option

RFC 1771 Border Gateway Protocol 4 RFC 1965 Autonomous System Confederations
for BGP

RFC 1966 BGP Route Reflection RFC 1997 BGP Communities Attribute

RFC 1745 BGP/OSPF Interaction RFC 2385 TCP MDS Authentication for BGP v4

IP Multicast

RFC 1112 IGMP v1 RFC 1591 DNS (client operation)

RFC 2236 IGMP v2 RFC 1122 Host Requirements

IGMP v3 RFC 768 UDP

IGMP Termination RFC 791 IP

IGMP Monitoring (in meaning of IGMP querier, same RFC 792 ICMP
features as 3089)

RFC 783 TFTP RFC 793 TCP

RFC 951, 1542 BootP RFC 826 ARP

Management - SNMP & MIBs & Others

RFC 1155 Structure of MGMT Information (SMI v1) RFC 1901 - 1907 SNMP Version 2c, SMIv2 and
Revised MIB-II
RFC 1493 Bridge-MIB (D-Bridge) RFC 1354 IP v4 Forwarding Table MIB

RFC 1757 RMON 4 Groups: Stats, History, Alarms, RFC 2922 Physical Topology MIB
and Events
Siemens Enterprise MIB (SLE) RFC 2934 PIM MIB

RFC 1157 SNMP v1/v2c RFC 854 Telnet

RFC-1212, RFC-1213, RFC-1215 MIP-II & TRAPs RFC 2030 Simple Network Time Protocol v4
(SNTP)
Security

RFC 1492 TACACS+ Radius Client

RFC 2138 RADIUS Authentication RFC 2267 Network Ingress Filtering

v1.0 Page 12 of 17
Data Sheet
V5824G

2.3 Physical Specification

Mechanics

Dimensions (W x H x D) 432 x 43 x 320 mm (17.0 x 1.7 x 12.6 in)


Operating Temperature -4~140° F (-20 ~ 60°C)
Storage Temperature -40~176° F (-40 ~ 80°C)
Operating Humidity Range 0% to 90% Non-condensing

Power Supply

DC power voltage (Dual DC) -48/60VDC


AC power voltage (Dual AC) 100-240VAC, 50/60Hz
Power Consumption 70W

Operating Indicators

System LEDs RUN / DIAG / PWR A / PWR B


PON i/f LEDs L/A
Combo type GE i/f LEDs L/A, SPD
10GbE i/f LEDs L/A, SPD
Console RX / TX
MGMT LNK / ACT

Interface Parameter

PON i/f 8 x GPON (SFP)


Combo type Gigabit Ethernet i/f 8 x 10/100/1000Base-T (RJ45) or
100/1000Base-X (SFP)

1/10Gigabit Ethernet uplink i/f 2 x 10GbE (SFP+)

Ethernet i/f for local management 10/100Base-TX (RJ45)


Serial i/f, Console 1-Port (RS232)

v1.0 Page 13 of 17
Data Sheet
V5824G

3 Component Options for V5824G

3.1 SFP+ Options


The following different optical SFP+ modules are available and can be inserted into the
dedicated modules.

SFP Module Description

SFPP-10GE-SR SFP+ 10GE SR


- Wavelength: 850 nm / Distance: 300 m / Mode: multi-mode
- Connector: LC / Data rate: 103125 Gbit/s / Core type: Dual Core
- Operating Temperature: 0 °C ~ 70 °C
- 10GBASE-SR(10G)
SFPP-1GE10GE-SR SFP+ 1GE/10GE SR
- Wavelength: 850nm / Distance: 300m / Mode: multi-mode
- Connector: LC / Data rate: 103125 Gbit/s / Core type: Dual Core
- Operating Temperature: 0 °C ~ 70 °C
- 1000BASE-SX(1G), 10GBASE-SR(10G)
SFPP-10GE-LR SFP+ 10GE LR
- Wavelength: 1310 nm / Distance: 10 km / Mode: single-mode
- Connector: LC / Data rate: 103125 Gbit/s / Core type: Dual Core
- Operating Temperature: 0 °C ~ 70 °C
- 10GBASE-LR(10G)
SFPP-10GE-ER SFP 10GE ER
- Wavelength: 1550 nm / Distance: 40 km / Mode: single-mode
- Connector: LC / Data rate: 103125 Gbit/s / Core type: Dual Core
- Operating Temperature: 0 °C ~ 70 °C
- 10GBASE-ER(10G)
SFPP-10GE-ZR SFP+ 10GE ZR
- Wavelength: 1550 nm / Distance: 80 km / Mode: single-mode
- Connector: LC / Data rate: 103125 Gbit/s / Core type: Dual Core
- Operating Temperature: 0°C ~ 70 °C
- 10GBASE-ZR(10G)

Table 3 SFP+ Modules

Other types of SFP+ module can be also available upon customer request.
i

v1.0 Page 14 of 17
Data Sheet
V5824G

3.2 SFP Options


The following different optical SFP modules are available and can be inserted into the dedi-
cated slots. Each SFP module contains one port.

SFP Module Description

SFP-GE-SX SFP GE SX
- Wavelength: 850 nm / Distance: 550 m / Mode: multi-mode
- Connector: LC / Data rate: 1.25Gbit/s / Core type: Dual Core
- Operating Temperature: 0 °C - 70 °C
SFP-GE-LX5 SFP GE LX5
- Wavelength : 1310nm / Distance : 5km / Mode : Singlemode
- Connector : LC / Data rate : 125Gbit/s / Core type : Dual Core
- Operating Temperature : 0 °C ~ 70 °C
SFP-GE-LX10 SFP GE LX10
- Wavelength: 1310 nm / Distance: 10 km / Mode: single-mode
- Connector: LC / Data rate: 1.25 Gbit/s / Core type: Dual Core
- Operating Temperature: 0 °C - 70 °C
SFP-GE-LX15 SFP GE LX15
- Wavelength : 1310nm / Distance : 15km / Mode : Singlemode
- Connector : LC / Data rate : 125Gbit/s / Core type : Dual Core
- Operating Temperature : 0 °C ~ 70 °C
SFP-GE-LX20 SFP GE LX20
- Wavelength: 1310 nm / Distance: 20 km / Mode: single-mode
- Connector: LC / Data rate: 1.25 Gbit/s / Core type: Dual Core
- Operating Temperature: 0 °C - 70 °C
SFP-GE-LX40 SFP GE LX40
- Wavelength: 1310 nm / Distance: 40 km / Mode: single-mode
- Connector: LC / Data rate: 1.25 Gbit/s / Core type: Dual Core
- Operating Temperature: 0 °C - 70 °C

Table 4 SFP Modules

SFP Module Description

SFP-GPON-OLT20 SFP GPON OLT


-. Wavelength: 1490nm/1310nm / Distance: 20km / Mode: singlemode
-. Connector: SC/PC / Data rate: 2.488Gbit/s (Up), 1.25Gbit/s (Down)
-. Core type : Single Core / Operating Temperature : -40 °C ~ 85 °C

Table 5 SFP Modules for GPON

Other types of SFP module can be also available upon customer request.
i

v1.0 Page 15 of 17
Data Sheet
V5824G

3.3 Power Options


Name Description Maximum
quantity

PSU_AC AC_power supply unit for V5824G 2


PSU_DC DC_power supply unit for V5824G 2
PSU_blank panel Blank panel for power supply unit 2

Table 6 Power Options

v1.0 Page 16 of 17
Data Sheet
V5824G

4 Ordering Information
Bases

V5824G
8-Ports GPON SFP, 8-Ports Combo type GbE(10/100/1000Base-T or 100/1000Base-X SFP), 2-Ports
1GE/10GE SFP+, 2 Blank Power Supply Module Slot

SFP+ Options

SFPP-10GE-SR, SFPP-1GE10GE-SR, SFPP-10GE-LR, SFPP-10GE-ER, SFPP-10GE-ZR

SFP Options

SFP-GE-SX, SFP-GE-LX5, SFP-GE-LX10, SFP-GE-LX15, SFP-LX20, SFP-GE-LX40

Power Options

PSU_DC, PSU_AC, PSU blank panel

DASAN Networks HQ
DASAN Tower, 49, Daewangpangyo-ro644Beon-gil, Bundang-gu, Seongnam-si, Gyeonggi-do, 463-400, KOREA Tel +82-70-7010-1000
www.dasannetworks.com

DASAN Networks USA, Inc.


5000 Research Court Suite 700, Suwanee, GA 30024 (Tel:770-674-0302)
www.dasannetworksus.com

v1.0 Page 17 of 17

You might also like