Applications include:
• Pressure testing
• Work holding/power clamping
• Jacking/lifting
• Valve actuator control
• Hydraulic cylinder actuation
• Press safety overload devices
• Roller tensioning
• Metering
• Precision lubrication and
spraying
• Liquefied gas transfer
2 www.haskel.com
Pressure and Flow on Demand Double and Triple Air
This guide will help you to pre-select the pump ideally suited Head Pumps
for your application. If you have specific questions, however, Performance can be extended for the 1.5 hp pumps by stacking
we urge you to provide Haskel with the operational details air pistons without changing the hydraulic piston. Haskel
of your application. We will recommend a model and any multi-head pumps consume less air than competitive single
corresponding accessories. head pumps of the same area, as only one head is pressurized
on the return stroke; e.g., on a 1.5 hp pump additional heads
Output Horsepower Ratings can raise performance to 2 hp.
The pumps are categorized on their horsepower ratings (see Double air head pumps are identified by the last digit 2 in the
pages 6-7). These are approximate and peak at 100 psi (7 pump model number. Thus, a nominal 50:1 ratio pump with two
bar), assuming adequate drive, pressure and volume. Peak air heads is described as a 52. Similarly, a triple air head pump
horsepower is at about 75% nominal ratio x drive pressure, i.e. is identified with a last digit 3. Thus, a 900 ratio pump with three
100:1 pump @ 100 psi air drive peaks at 100 x 100 = 10000 x 0.75 air heads is described as a 903.
psi = 7500 psi (517 bar) hydraulic pressure.
Operation
The pumps automatically reciprocate
on a differential piston principle. A large
piston driven by relatively low pressure
drive acts directly upon a smaller 0.65 sq in (4 sq cm)
hydraulic piston. Therefore, actual ratio = 40:1
The nominal ratio between piston sizes Nominal Ratio = 35:1
is indicated in the model coding and Double Air Head Pump
approximates to the maximum working
Area 25.9 sq in (167 sq cm)
pressure. The actual ratio is about
15% above nominal so that the pump
continues to cycle when drive pressure
equals nominal ratio. Initially, the pump Area 25.2 sq in (163 sq cm)
will cycle at maximum speed acting as a
transfer pump to pressurize downstream.
It will cycle at a slower rate as the
fluid meets resistance until it stalls
at maximum output pressure. When Area .65 sq in (4 sq cm)
a pressure drop downstream occurs, Therefore, actual ratio = 79:1
it will recycle as necessary in an Nominal Ratio = 72:1*
effort to maintain maximum pressure. Triple Air Head Pump
Stall pressure is achieved when
the outlet pressure rises and offers Area 25.9 sq in (167 sq cm)
more resistance to the reciprocating
differential piston assembly. The piston Area 25.2 sq in (163 sq cm)
assembly then stalls when the forces
balance, e.g. when drive pressure x drive Area 25.2 sq in (163 sq cm)
piston area equals outlet (stall) pressure
x driven hydraulic plunger area. The
pump design is sensitive to very small
pressure drops due to the low frictional
resistance of the large diameter drive Area .65 sq in (4 sq cm)
piston and hydraulic piston seals. Therefore, actual ratio = 118:1
Nominal Ratio = 103:1**
Nominal Ratio
* (2) Indicates Double Drive Piston
** (3) Indicates Triple Drive Piston
www.haskel.com 3
1. Drive Anatomy of a Pneumatic Driven Pump
Section
1. Drive Section
The piston, complete with “O” ring seal, operates in an epoxy filled,
fiberglass wound barrel, the diameter of which is constant throughout
a given series of pumps. Drive media forces the piston down on the
compression stroke and raises it on the suction stroke (M series have a
spring return). The piston is pre-lubricated during assembly and therefore
no air line lubricator is necessary.
2. Hydraulic Section/Check Valves
The drive piston is linked and connected to the hydraulic plunger/piston
in the hydraulic section. Outlet flow and pressure are determined by the
area of the hydraulic piston head, its nominal ratio with the drive piston
head, and drive pressure. On the down stroke, liquid in the hydraulic
section is forced under compression through the outlet check valve.
Fresh liquid is induced via the inlet check valve on the return stroke.
2. Hydraulic
Check
These check valves control the flow of liquid through the hydraulic
Valves section. They are spring-loaded and have a very low cracking pressure,
allowing maximum opening on the induction stroke. The pressure of
hydraulic fluid on the down stroke closes the inlet check valve and acts
against the spring to open the outlet check valve.
3. Drive Cycling Valve
This is a pilot-operated, unbalanced, lightweight spool, which directs
drive pressure, first to the top of the drive piston, and then to the
underside to reciprocate the piston (cycle). It actuates via pilot valves at
the top and the bottom of the stroke, which causes the unbalanced spool
to shift and reciprocate the piston.
4. Hydraulic Seal/Check Valves
This is one of the few wear parts. Its function is to allow the hydraulic
piston to reciprocate without passing fluid into the drive section. The liquid,
3. Drive its pressure and its temperature determine seal specification. A distance
Cycling piece can be incorporated between drive and hydraulic sections for
Valve complete contamination-free operation on most Haskel pumps.
4. Hydraulic
Seal
4 www.haskel.com
WETTED MATERIALS OF CONSTRUCTION AND SERVICES
WETTED MATERIALS
MODEL SERVICES NON METALLICS
(refer to pg. 17)
PUMP SECTION PLUNGERS
29723 1, 2, 3, 5, 6 Separation - All SS Hard Chrome Plated 15.5PH SS + Dichronite UHMWPE, PTFE, Ryton
MDSTV 1, 2, 3, 4, 5, 6 Stainless Steel and Aluminum 303 Stainless Steel Viton, PTFE
GW 1 Nickel Plated Steel, SS & Bronze Hard chrome plated 15.5PH SS Urethane, Buna N, PTFE
GSF 1, 2 All SS & Bronze Hard chrome plated 15.5PH SS UHMWPE, Viton, PTFE, Ryton
DGSF 1, 2, 3, 5, 6 Separation- All SS & Bronze Hard chrome plated 15.5PH SS UHMWPE, Viton, PTFE, Ryton
DGSTV 1, 2, 3, 4, 5 Separation- All SS & Bronze Hard chrome plated 15.5PH SS Viton, PTFE, Ryton
GWD 1 Nickel Plated Steel & SS 15.5PH SS Hard chrome plate optional Urethane, Buna N, PTFE
6 hp
GSFD 1, 2 All SS & Bronze 15.5PH SS Hard chrome plate optional UHMWPE, Buena N, PTFE, Ryton
DGFD 1, 3, 5 Separation- Nickel Plated Steel & SS 15.5PH SS hard chrome plate optional UHMWPE, Viton, PTFE, Ryton
DGSFD 1, 2, 3, 4, 5, 6 Separation- All SS & Bronze 15.5PH SS Hard chrome plate optional UHMWPE, Viton, PTFE, Ryton
DGSTVD 1, 2, 3. 4, 5 Separation- All SS & Bronze 17.4PH SS Hard chrome plate optional PTFE, Viton
8SFD 1, 2 All SS & Bronze* Hard chrome plated 15.5PH SS UHMWPE, Viton, PTFE, Ryton
8DSFD 1, 2 ,3 ,5, 6 Separation- All SS & Bronze 15.5PH SS Hard chrome UHMWPE, Viton, PTFE, Ryton
8DTVD 1, 2, 3, 4, 5, 6 Separation- All SS & Bronze 15.5PH SS Hard chrome PTFE, Viton
8 hp
D14STD-125 1, 2, 3, 4, 5A All SS & Bronze Hard chrome plated 440C SS PTFE, Viton
D14STD-315 1, 2, 3, 4, 5A All SS & Bronze Hard chrome plated 440C SS PTFE, Viton
10 hp
D14SFD-125 1, 2, 3, 5A, 6 All SS & Bronze Tungston Carbide Coated 15.5PH SS UHMWPE, Viton, PTFE, Ryton
D14SFD-315 1, 2, 3, 5A 6 All SS & Bronze Tungston Carbide Coated 15.5PH SS UHMWPE, Viton, PTFE, Ryton
www.haskel.com 5
Performance and Specification Overview
Maximum Rated Output Pressure
Air Head
Max Air
Displacement/Cycle Maximum Flow
Power
Pump Model Code Ratio Dash Actual Area Continuous Intermittent
no. Ratio
psi bar psi bar cu in ml cu in/min l/min
M, MS, 29723
-71 82 8800 607 8800 607 0.06 1.0 39 0.64
-110 126 13500 931 13500 931 0.039 0.60 25 0.42
M, MS -188 217 15000 1034 15000 1034 0.023 0.40 18 0.29
29723 -188 217 10000 1034 10000 1034 0.023 0.40 18 0.29
MS -220 220 20000 1380 25000 1723 0.021 0.34 14 0.22
0.75 hp
-37 42
Single
1.5 hp
2 hp
-122 138 15000 1034 19000 1310 0.67 11.0 201 3.3
-202 230 30000 2069 33000 2276 0.41 6.7 92 1.5
HF, HSF, DSHF
-302 346 30000 2069 50000 3448 0.27 4.5 61 1.0
-452 520 30000 2069 70000 4828 0.18 3.0 41 0.7
DSXHF
-602 690 30000 2069 75000 5172 0.14 2.3 32 0.5
2 hp
DSXHW -1373 1575 30000 2069 100000 6897 0.086 1.4 12 0.197
AFD-DFD-ASFD-DSFD -B60 69 6500 448 6500 448 1.34 2.2 369 6.0
2.2
-10 11.5 1600 110 1600 110 8.10 133 1823 29.9
-15 17 2400 165 2400 165 5.40 89 1215 19.9
-25 29 4000 276 4000 276 3.24 53.6 729 11.9
150 psi/10.5 bar
GWD, GSFD, DGSFD, DGSTVD -12 14.8 1850 128 4000 276 15.9 260 5009 82.1
-35 40.3 4375 302 4375 302 6.0 98 1890 31.0
Single
8SFD, 8DSFD, 8DSTVD -25 27.5 3575 246 4000 276 14.0 229 2660 43.5
125 psi/8.6 bar
-40 43.5 6000 414 6000 414 8.90 145 1691 28.0
8SFD
-65 73 10000 690 10000 690 5.40 88 1026 17.0
8DSFD -100 112 10000 690 10000 690 3.52 58 669 11.0
8 hp
8HSFD -225 253 25000 1724 25000 1724 1.56 26 296 5.0
-55 55 5500 379 7200 497 14.14 232 1900 31.1
8SFD2 -88 88 8800 607 10000 690 8.84 145 1182 19.36
(Double Air Drive Piston Models)
-224 225 25000 1724 25000 1724 3.53 58 476 7.6
D14STD, D14SFD -125 138 16000 1103 16000 1103 8.80 144.2 704 11.5
10 hp
-315 347 36000 2483 36000 2483 3.50 57.4 280 4.6
6
Typical Performance using 100 psi (7 bar) Air drive
Outlet Pressure Outlet Flow Outlet Pressure Outlet Flow
Pump Selection Information
psi bar cu in/min l/min psi bar cu in/min l/min
All Haskel pumps are identified by letters coding the type of
225 15.5 500 8.20 415 29 249 4.09
300 21 350 5.70 600 41 160 2.6 pump, followed by a number indicating the practical working
700 48 200 3.28 1125 78 100 1.64 ratio of the drive area to the hydraulic plunger area. These
1500 103 90 1.48 2000 138 48.9 0.8 letters are explained in the chart below.
1700 117 70 1.15 3100 214 39.6 0.65
2450 169 tbd tbd 4500 310 tbd tbd
Pump Model Letter Coding
3000 207 40 0.64 6000 414 19 0.31
7500 517 20 0.33 10000 690 8.5 0.14 M .875” stroke .33 hp miniature pump series
5000 345 18 0.30 10000 690 14 0.23 S Stainless steel hydraulic piston and body
5000 345 18 0.30 10000 690 14 0.23 29723 .33 hp Chemical Pump
7500 517 15 0.24 15000 1034 12 0.2
D (Prefix) Pump incorporates a Distance Piece
700 48 400 6.55 1450 100 61 1.00 D (Suffix) Double Acting pump
1500 103 200 3.28 3000 207 62 1.00 4B 1” stroke .75 hp pump series (bottom inlet only)
1750 121 170 2.78 3500 241 82 1.33 A 2” stroke 1.5 + 2 hp pump series
2000 138 110 1.80 5000 345 66 1.08 H 2” stroke 1.5 + 2 hp High Pressure pump series
5000 345 57 0.93 10000 690 26 0.43
XH 2” stroke 1.5 + 2 hp Extreme High Pressure pump series
G 4.5” stroke 6 hp pump series
50 3 5000 81.9 150 10 1000 16.4
B 4.5” stroke 8 hp pump or booster series
100 7 1953 32 400 28 750 12.3
400 28 1000 16.4 990 68 500 8.19 14 4” stroke 10 hp pump series
750 52 598 9.8 1600 110 200 3.28 W Polyurethane U-cup dynamic seal
1000 69 403 6.6 2500 172 195 3.2 F UHMWPE (Ultra-high Molecular Weight Polyethylene Dynamic Seal
2000 138 350 4.1 3600 248 98 1.6 T Reinforced Teflon® dynamic seal
3000 207 152 2.5 6200 427 50 0.82
V Viton® o-ring static seal
4000 276 100 1.64 10000 690 24.4 0.4
7000 483 59.7 0.98 15000 1034 29.9 0.49
7000 483 59.7 0.98 15000 1034 29.9 0.49
7500 517 39.6 0.65 24000 1655 9.8 0.16
15000 1034 29.9 0.49 27000 1862 20.1 0.33
36000 2483 14.6 0.24 45000 3103 9.2 0.15
www.haskel.com 7
.33 hp (.25 kW) M Series Pump Models
*Note: 29723 series rated to 10,000 psi (690 bar) maximum (ratios -110 and -188)
Key Features
• Choice of 6 models, 9 ratios, • Pressures to 25,000 psi
27 possible combinations (1724 bar) For service codes, see page 17.
• Flows to 2 gpm (7.5 l/min) • All Hydraulic fluids, water For weights and dimensions, see page 18.
Optional Modifications
Number Description
-HP Hand pump attachment (with handle). Provides manual operation of pump for
precision pressure control or use without air power
26220-2 Hand pump attachment kit.
29002 Viton air drive.
51331 EPR seals for liquid section for 29723-XX ratio pumps.
51788 Piped exhaust – standard. Provides connection ports for drive and pilot exhausts.
Enables under tank top mounting and/or natural gas drive.
51794 Piped exhaust – sour gas. With hand pump (HP).
51794-2 Piped exhaust – sour gas. Without hand pump (HP).
53175 Level II cleaning.
53304 High pressure outlet port. Fits ¼” O.D. high pressure threaded and coned tube.
53935 Low temperature drive. Enables operation down to 5°F. Some sacrifice of seal life at
normal temperature. M or MS series.
57905 No return spring. Provides improved fill on suction stroke pumping liquefied gases
by utilizing the inlet pressure. Only available on M and MS series.
59888 Cycle timer installed.
80103 Noise reduction kit fitted.
82367 SS trim for 1⁄3 hp drive
8 www.haskel.com
.75 hp (.56 kW) Pump Models
Key Features
• One model available • Choice of wetted materials
in 5 ratios • Single air head
• Output pressures to • Drive pressure 3 psi to
10,000 psi (690 bar) 100 psi (.2 to 7 bar)
• Flows to 1.5 gpm (5.7 l/min)
Optional Modifications
Number Description
57639 Low drive air pressure. Allows user to regulate drive air to as low as 3 psi (.2 bar).
59354 Noise reduction kit fitted.
81575 Changes the “F” seal to a “W” seal. Recommend for use with water.
82104 Viton air drive.
www.haskel.com 9
1.5 hp (1.12 kW) Pump Models
Key Features
AW, ASF, -100 16500 psi (1138 bar) .4 cu in (6.7 ml)
• Choice of 10 models, • Choice of wetted materials
13 ratios, 50 possible DSF, -150 20000 psi (1375 bar) .28 cu in (4.5 ml)
• Single air head DSTV
combinations
• Drive pressure 3 to 150 ps
• Output pressures to (.2 to 10 bar) HF, HSF, -151 25000 psi (1724 bar) .28 cu in (4.5 ml)
50,000 psi (3448 bar)
DSHF -225 37000 psi (2551 bar) .18 cu in (3.0 ml)
• Flows to 22 gpm (83.0 l/min) -300 50000 psi (3448 bar) .14 cu in (2.3 ml)
Optional Modifications
Number Description
16821 Low air pressure control feature. For operating at air pressures as low as 3 to 4 psi (1) These series are “Lift” pumps and maximum outlet
(.2 to .3 bar). Includes 28881 modification. 45 psi minimum pilot air required. pressure is (air drive x pump ratio) + inlet pressure
(2) DTV has poppet checks
16831 Low temperature modification. For special sealing in air drive for operating
temperatures from as low as -20°F up to normal +120°F.
51345 Sour gas drive provision to N.A.C.E. specifications. 1.5 hp to 2.2 hp distance piece
pumps only, single air head and double air head.
10 www.haskel.com
1 . 5 1h
. 5p h( 1
p. 1
(12. 1
k2Wk
)WH )i gHhi gOhu O
t puuttp u t Mounting Brackets
F l oFwl oPwu m Pupms ps All series mounting brackets have 7/16” holes (slots) for 3/8”
All series mounting brackets have 7/16” holes (slots) for 3/8”
Available in a choice of 4 models, these high output, low bolts. Upper mounting brackets are not furnished as standard
bolts. Upper mounting brackets are not furnished as standard
Available in a choice of 4 models, these high output, low ratio
ratio pumps are capable of pressures to 1200 psi (82 bar) and
pumps are capable of pressures to 1200 psi (82 bar) and flow on single air head non-distance piece units.
flow rates of up to 22 gpm (83 l/min). These are “lift” pumps
rates of up to 22 gpm (83 l/min). These are “lift” pumps whereby
whereby the outlet pressure equals the air drive x the pump
the outlet pressure equals the air drive x the pump ratio plus the D
D ii m
meen
nssi o n a l D a t a Mounting B
B rr a
acck
kee tt s
s
ratio plus the inlet pressure.
inlet pressure.
Model DSTV-1.5 has a maximum air drive of 150 psi (10 bar)
Model DSTV-1.5 has a maximum air drive of 150 psi (10 bar) and
and is capable of pressures up to 160 psi (11 bar). The model
is capable of pressures up to 160 psi (11 bar). The model ATV,
ATV, DTN-4 and DTV-4 work on a maximum air drive of 150 psi
DTN-4 and DTV-4 work on a maximum air drive of 150 psi (10 bar)
(10 bar) and have a maximum intermittent pressure rating of
and have a maximum intermittent pressure rating of 1200 psi (83
1200 psi (83 bar). A noise reduction modification is available
bar). A noise reduction modification is available for applications
wherefornoise
applications where
level is an issue.noise level is an issue.
D i sD
tai sntcaen c
Pei eP
ciee c
(Se e(p
Saerpaat ri o
a tni)o n )
Pumps with prefix “D” in the model number have aluminum
Pumps with prefix “D” in the model number have aluminum Optional Pump Inlets for Tank Mounting
distance piece between the air drive and pump section
distance piece between the air drive and pump section (except
(except DSTV-1.5).
DSTV-1.5). Vent holes can be threaded ½” NPT female at extra To specify ratios To specify ratios
-10, -15, -22 or -32, -25 through -903,
cost. Specify modification number 28000. Horizontal mounting is add “BR” between add “B” between
the model number the model number
recommended for non-exchange of contaminants. and the ratio, e.g. and the ratio, e.g.
AW-BR10. AW-B25.
Inlet externally Inlet on the bottom
threaded 1 ¼” and externally
NPT male threaded
Internally threaded 1” NPT male
1” NPT female Internally threaded
½” NPT female
Drive inlet and exhaust are ½” NPT female. Drive inlet also includes a ½” NPT male x ½” NPSM female
(straight pipe thread) swivel adapter (connecting male nipple should include 30° inside bevel for proper fit).
www.haskel.com 11
2 & 2.2 hp (1.49 & 1.64 kW) Pump Models
2 hp
DSXHF -452 70000 psi (4827 bar) .18 cu in (3.0 ml)
-602 75000 psi (5171 bar) .14 cu in (2.3 ml)
Key Features
DSXHF -683 70000 psi (4827 bar) .18 cu in (3.0 ml)
• Choice of 16 models, • Flows to 5 gpm (15 l/min)
-903 75000 psi (5171 bar) .14 cu in (2.3 ml)
13 ratios, 46 possible • Choice of wetted materials
combinations
• Double and triple air heads DSXHW -1373 100000 psi (6895 bar) .09 cu in (1.4 ml)
• Output pressures to
100000 psi (7000 bar) • Drive pressure 3 to
100 psi (.2 to 7 bar) AFD, DSFD, -B60 6500 psi (448 bar) 1.3 cu in (22 ml)
2.2 hp
DFD, ASFD
When using high pressure ratio pumps the reliability of the XH models
(-452 through -1373) will be improved with an air driven supercharge
pump, not only to simplify priming but to reduce fatigue stresses. The
higher the supercharge, the better the results. Also install a relief valve
to protect the lower pressure pump from potential back pressure.
Supercharging of the -1373 model is recommended. This approach will For service codes, see page 17.
ensure a reasonable life for the seals and other wear components. For weights and dimensions, see page 20.
12 www.haskel.com
Optional Modifications (for 2 hp, 2.2 hp and 3 hp pump models)
Number Description
16821 Assures reliable drive operation with pressures low as 3 psi as long as 20 psi or 55516 Polyurethane (“W”) seal. For F or TV series pumps, except high output models.
more is provided to the separate 1⁄8” NPT port.
59353 Noise reduction kit fitted. Not available on AFD, DFD, ASFD or DSFD.
16831 Low temperature modification. For special sealing in air drive for operating 55465 Ceramic Plunger -60 Ratio.
temperatures from as low as -20°F up to normal +120°F.
55516 Polyurethane “W” seal in “F” series pumps-except high output models.
16834 Exhaust adapter. With back pressure balance piston. 59353 Noise reduction kit fitted. Not available on AFD, DFD, ASFD or DSFD.
29376 Three-way cycling spool. For 1.5 hp and 2 hp single acting pumps. 59888 Cycle timer installed.
51050 Extreme service cycling modification. Not recommended for long stall periods. 82460 HNBR Seals in air drive section.
51056 Exhaust/pilot vent combination.
51331 EPR (Ethylene propylene) static seals in wetted section. Applies to distance piece
pumps only.
51345 Sour gas drive provision to N.A.C.E. specifications. 1.5 hp to 2.2 hp distance
piece pumps only, single air head and double air head.
52788 Viton seals. Air drive only – 1.5 hp to 2.2 hp pumps only.
53925-4 Severe Arctic low temperature service. -10, -15, -22, -32
54885 Rotate pump body 90° from standard. Except 3 hp pump.
54935 SS trim for 5/3 air drive.
www.haskel.com 13
6 hp (4.47 kW) Pump Models
GW, GSF, -35 4375 psi (302 bar) 6.0 cu in (98 ml)
DGSF, -60 7500 psi (517 bar) 3.5 cu in (57 ml)
DGSTV -100 10000 psi (690 bar) 2.1 cu in (34.5 ml)
14 www.haskel.com
10 hp (7.46 kW) Pump Models
10 hp (7.46 kW) Pump Models
www.haskel.com 15
www.haskel.com 15
P o w e rr S
Syysstteem
m SSppeecci iaal li s
i st s
ts Quuaalliittyy a
Q an nd
World safety standards
standards and andquality
qualitydemands
demandsarearerising.
rising. Afftteerr--S
A Saall e
e Service
Component manufacturers
manufacturers are arerequired
requiredto
toprovide
providetest
test Haskelmeets
Haskel meetsthetherequirements
requirementsofofinternational
certification and
and product
product quality
qualityassurance
assurancewhich
whichcan canonly
onlybebe international
quality quality
assurance ISOassurance
9001. BuildISO 9001.is
quality
determined using
using the
the types
typesof
ofsystems
systemswhich
whichHaskel
Haskelcan canprovide.
provide. Build quality
matched by anisinnovative
matched by an innovative
design and problem
Typically, we have
have built
built systems
systemsfor
forproduction
productionand
andfield
fieldtesting
testing design andability
solving problem solving
which stemsability
from which
years of stems
yearsfrom years of
of experience.
the proof, leak,
leak, and
and burst
burstaspects
aspectsofofhoses,
hoses,cylinders,
cylinders,andandvalves.
valves. years
Our of experience. Our
representatives representatives
around the world are around the world
carefully chosenareand
These systems can can be
be portable,
portable,mobile,
mobile,or
orstatic
statictest
testrigs.
rigs.We
We also carefully
trained chosen
to help and
you trained
arrive atto
a help you
correct arrive
product at a correct
choice, and to offer
also
offeroffer a range
a range of standard
of standard pressure
pressure packs
packs usedused for power
for power jacking, product
a choice,
maintenance and
andto offer
parts a maintenance
service that is and
second parts
to service
none.
jacking,
clamping,clamping,
and other and other applications
applications where reliable
where reliable power is needed. that is second to none.
power
is needed.
Selecting Your Accessories
Haskel can either provide accessories separately or supply them fitted to form a complete
package suited to your application. Additionally, Haskel can customer nominated
accessories. Our accessories catalog is available and our technical support team is always
ready to advise you on the most suitable choice of accessories for your application.
• Air pilot switches • High pressure valves, fittings and • Stainless steel check valves
• Air pilot valves tubing Intensifiers with integral checks for
• Regulating relief valves • Plenum chambers cycling
• Directional control and release valves • Port adapters • Capillary type gauge snubbers
• Hydraulic accumulators, gas receivers • Gauge snubbers Please ask for your copy of our latest
and storage cylinders • Filters accessories brochure.
16 www.haskel.com
Liquids Compatible with Services
Services
Haskel Pumps hphp Model
Model 1 1 2 2 3 3 4 4 5 5 66
www.haskel.com 17
NB. Plan view of
M-Pump is common to
all M-Series pumps.
1.91 mm
(.075”)
Weights and
Dimensions 206 mm
(8”)
.33 hp (.25 kW) M Series Pump Models M-7, M-12 MS-7, MS-12
approx. weight 9 lbs (4 kg) approx. weight
9 lbs (4 kg)
Net weight 4 kg
Boxed weight 4.25 kg
Box size 23 x 18 x 12 cm
Net weight 6 kg
Boxed weight 6.5 kg
Box size 30 x 20 x 15 cm
MS-21, MS-36, MS-71, M-21, M-36, M-71, M-110, MS-220 approx. weight M-5 approx. weight 9 lbs (4 kg)
MS-110, MS-188, approx. M-188 approx. weight 6 lbs 6 lbs (2.7 kg)
weight 6 lbs (2.7 kg) (2.7 kg)
18 www.haskel.com
29723-21, 29723-36, 29723-71, 29723-110 MDSTV-5 , MDTV
approx. weight
29723-21,
29723-21, 6.529723-36,
29723-21,
29723-36,lbs29723-71,
29723-36, (329723-71,
kg)
29723-71,
29723-110
29723-110
29723-110 Approx
MDSTV-5weight
MDSTV-5
MDSTV-5
, MDTV ,15
, MDTV 1/2 lbs (7 kg)
MDTV
approx.
approx.
approx.
weight
weight
weight
6.5 lbs
6.56.5
lbs
(3 lbs
kg)
(3 (3
kg)kg) Approx
Approx
Approx
weight
weight
weight
15 1/2
1515
lbs
1/21/2
lbs
(7 lbs
kg)
(7 (7
kg)kg)
.75 h . 7p5 ( h
. 5p6 (k . 5W6) kPWu )mPpuMmopd M
e losd e l s
. 7.57. 75h5phh
p( p
.5
( .(65. 5
6k6W
kkW
)WP
) )u
PmP
uum
pmpM
pMoM
doe
o
dldese
l sl s
Model 4B-14,
ModelModel
Model 4B-21,
4B-14,4B-14,
4B-14, 4B-25
4B-21,and 4B-30
4B-21,
4B-21,
4B-25 4B-25
4B-25
andand
4B-30
and
and
4B-30 4B-30
4B-30
Model Model
Model
4B-55 4B-55
4B-55
andandand
Model 4B-55 and
4B-75 4B-75
4B-75
4B-75
www.haskel.com
www.haskel.com
www.haskel.com19 19
www.haskel.com
www.haskel.com 19 19
1.5 hp, 2 & 2.2 hp (1.12, 1.49 & 1.64 kW) Pump Models
DSFD-B60
Net weight 18 kg
Boxed weight 20 kg
Box size 68 x 42 x 50 cm
Net weight 10 kg
Boxed weight 11 kg
Box size 37 x 37 x 38 cm
25.4 mm = 1 inch
Net weight 14 kg
Boxed weight 15 kg
Box size 52 x 40 x 40 cm
1
⁄4 HP port (-202, -302)
ModelModel
4B-37 4B-37
approx.
approx. weightweight
10 lbs 10
(4.5lbs
kg)(4.5 kg)
ModelModel
4B-1004B-100
4B-100 & 4B-150
& 4B-150
approx.
approx.
approx. weightweight
weight 11 lbs(511
11lbs lbs (5 kg)
(5kg)
kg)
1 . 51 h
. 5p
1 ,.h52
p&, p
h 2 .,&22
2 2h. 2p
& 2 .h(21
p .h1
(p
12.,(111
2..,142
19,. 4&
19. 1
4&.9614
&. 6k14W
. 6k Wu
)4P k) m
Pu
W p
)PmM
upm
oM
dpeoM
ldso
e ldse l s
DSFD-B60
DSFD-B60
www.haskel.com21
www.haskel.com
511.h.5
15
p. h
,5hp
2p
h,&
,p2
2,2&
.&
22&
2.h.2
22
p. h
2h
(p1p
h.(p
1(11
2.(.,1
112
.12
1,.,2
41,1
9. .4
14
&9
.9
41&
9&
. 6&
11
4. .6
16
k4
.4
W
6k4)kW
P
Wku
)W
)P
mP)up
u
Pmm
uM
ppoM
m pd
MoeM
od
ld
s
oee
dl(ls
cslo(s(c
e nco
(to
.n)n
c ot tn
. .)t) . )
Net weight 18 kg
Net weight 18 kg
Net weight 18 kg
Boxed weight 20 kg
Boxed weight 20 kg
Boxed weight 20 kg
Box size 68 x 42 x 50 cm
Box size 68 x 42 x 50 cm
Box size 68 x 42 x 50 cm
Net weight 10 kg
Net weight 10 kg
Net weight 10 kg
Boxed weight 11 kg
Boxed weight 11 kg
Boxed weight 11 kg
Box size 37 x 37 x 38 cm
Box size 37 x 37 x 38 cm
Box size 37 x 37 x 38 cm
1.5 and
1.5
1.5
2and
hp
and
low
2 2hphp
ratio
low
lowpumps;
ratio
ratiopumps;
pumps;
-B10 and
-B10
-B10
-B15
and
andratios
-B15
-B15ratios
ratios
Net weight 14 kg
Net weight 14 kg
Net weight 14 kg
Boxed weight 15 kg
Boxed weight 15 kg
Boxed weight 15 kg 25.4 mm
25.4
25.4
=mm
1
mminch
==1 1inch
inch
Box size 52 x 40 x 40 cm
Box size 52 x 40 x 40 cm
Box size 52 x 40 x 40 cm
2 2hphpratio
2 hp high high ratio
ratiopumps;
highpumps; pumps;
-683
-683 and
-683 and
-903
and-903
-903ratios
ratios ratios
1
⁄2” NPT
⁄2”⁄2”(-52,
1 1
NPT
NPT-72,
(-52,
(-52,
122)
-72,
-72,122)
122)
LiquidLiquid
Liquid
Outlet Outlet
Outlet 394 mm 394394 mm mm Breathers
Breathers
Breathers
(15 1/2”) (15 1/2”)
(15 1/2”)
1
⁄4 HP1port
⁄41⁄HP
4 HP (-202,
port
port(-202,
-302)
(-202,-302)
-302)
Air DriveAir
Inlet
Air
Drive
Drive
Inlet
Inlet
1/2” NPT1/2” NPT
1/2” NPT
1.5 and
1.5
1.5
2and
hp
andmedium
2 2hphpmedium
medium
ratio pumps;
ratio
ratiopumps;
pumps;
-52, -72,
-52,
-52,
-122,
-72,
-72,-202
-122,
-122,
and
-202
-202
-302
and
andratios
-302
-302ratios
ratios
Liquid Inlet
Liquid
Liquid
Inlet
Inlet Liquid Outlet
Liquid
Liquid
Outlet
Outlet
Air Exhaust
Air Exhaust
Air Exhaust 1/2” NPT1/2” NPT
1/2” NPT 3/4” HP Port
3/4” HP Port
3/4” HP Port
1/2” NPT1/2” NPT
1/2” NPT
Net weight 18 kg
Net weight 18 kg
Net weight 18 kg
Boxed weight 19 kg
Boxed weight 19 kg
Boxed weight 19 kg
Box size 45 x 37 x 44 cm
Box size 45 x 37 x 44 cm
Box size 45 x 37 x 44 cm
ATV-4ATV-4
pumps;
ATV-4pumps;
pumps;
double
double
double
acting,
acting,
acting,
high output
high
highoutput
output
Note: For model DTV-4,
Note: For model DTV-4,
Note: For model DTV-4,
add distance
add
add
distance
piece
distance
dimension
piece
piece
dimension
dimension
from page
from
from
11.page
page
11.11.
Interconnecting
Interconnecting
Interconnecting
inlet andinlet
outlet
inlet
andand
port
outlet
outlet
tubing
port
port
shown.
tubing
tubing
shown.
shown.
DSTV-1.5
DSTV-1.5
DSTV-1.5
pump;pump;
single
pump;single
single
www.haskel.com
acting,
acting,
acting,
high output
high
highoutput
output
www.haskel.com
222 22 www.haskel.com
www.haskel.com
Net weight 9.5 kg
Net weight 9.5 kg
Boxed weight 10 kg
Boxed weight 10 kg (9 7/8”)(9 7/8”)
11 mm 11 mm 76 mm 76 mm Mounting 119 mm119 mm
Mounting
Box size 25 x 26 x 22 cm
Box size 25 x 26 x 22 cm BracketBracket (4 11/16”)
(4 11/16”)
(7/16”) (7/16”)
(TYP) (TYP) (3”) (3”) (2 places)
(2 places)
HandleHandle
1
⁄2” NPT
1
⁄2” NPT 279 mm279 mm
LiquidLiquid (11”) (11”)
64 mm 64 mm
413 mm413 mmAir Drive Air Drive Air Drive
AirInlet
DrivePort
Inlet Port
Outlet*
Outlet* (15 1/4”)(15 1/4”)ExhaustExhaust
Port Port (2 1/2”)(2 1/2”) 1/2” NPT1/2” NPT
1/2” NPT
1/2” NPT
154 mm154 mm
17 mm 17(6mm1/16”)(6 1/16”) 105 mm105 mm
(11/16”)(11/16”) (4 5/32”)(4(TYP)
5/32”) (TYP)
1.5 and
1.5 2and
hp 2medium
hp medium
and high
and high
ratios;
ratios;
-25 -25 Hydraulic
Hydraulic
Outlet Port
Outlet Port Hydraulic
Hydraulic
Inlet Port
Inlet Port
1/2” NPT
1/2” NPT 144 mm144 mm 1/2” NPT
1/2” NPT
through
through
-150,-150,
-151*,
-151*,
-225*,
-225*,
-300*-300*
and -450*
and -450*
ratios
ratios (2 places,
(2 places,
this side)
this side) (5 11/16”)
(5 11/16”) (2 places,
(2 places,
this side)
this side)
102 mm102 mm
(4”) (4”)
*1⁄4” Super
*1⁄4” Super
Pressure
Pressure
Outlet
Outlet
Port Port 209 mm209 mm
(8 1/4”)(8 1/4”)
ATV-8
ATV-8
pumps
pumps
AFD AFD
or ASFD,
or ASFD,
-B60,-B60,
-B100-B100
pumps;
pumps;
double
double
acting,
acting,
highhigh
output
output
3 h
3 ph3(p2h.( p
2
24 . 22k
4W k4)WP ) uPmup
muMpmoMdoeM
dl se ldse l s
h p( 2( .22.(4
3 3h p 2 4.k2W
kW ) k)PWu)m
P P
ump pMMopd
oed leo
sl s
AIR DRIVE
AIR DRIVE
INLET INLET
PORT PORT
1/2” NPT
1/2” NPT
}}} }
ASFD-15
ASFD-15 ASFD-100
ASFD-100
ASFD-100
ASFD-100 3 3⁄83" med.
3
⁄8" med.
⁄8" med.
⁄8" med.
ASFD-150
ASFD-150
ASFD-60ASFD-150
ASFD-150 pressure
pressure pressure
pressure
1/2” NPT
ASFD-10
ASFD-10
ASFD-10
ASFD-10
OUTLETOUTLET
PORT PORT
ASFD-202
ASFD-202
1/2” NPT
1/2” NPT
ASFD-202
ASFD-202
www.haskel.com
www.haskel.com
www.haskel.com2323
6 hp (4.47 kW) Pump Models
Models DGSFD,
DGFD, DGSFD,
DGSTV DGSTVD nominal
nominal ratio 12:1 ratio 12:1
24 www.haskel.com
88 hhp
8p (h(5p
5. .99
(757.k9kW
7W)k) P
WPu)um
m
Ppu
pmM
MpoodM
dee
ol ls
dse l s
9.65 9.65
[245 [245
mm] mm]
27.6627.66
5.21 5.21 [703 [703
mm] mm]
[132 [132
mm] mm]
AIR DRIVE
AIR DRIVE INLETINLET 22.9322.93
PORTPORT
3/4" 3/4"
NPTNPT [582 [582
mm]mm]
(130(130
PSIGPSIG
MAX)MAX)
CYCLING
CYCLING SPOOL
SPOOL ACCESS
ACCESS
2X LIQUID
2X LIQUID
INLET
INLET
PORTPORT
3/8" 3/8"
HIGHHIGH
PRESSURE
PRESSURE
(25,000
(25,000
PSIGPSIG
MAX)MAX)
10.9610.96
[278 [278
mm] mm]
10.1710.17
2X DRIVE/SEAL
2X AIR AIR DRIVE/SEAL SECTION
SECTION [258 [258
mm] mm]
VENTVENT
PORTPORT
1/4" 1/4"
NPTNPT
4.88 4.88
[124 [124
mm] mm]
2X LIQUID OUTLET
2X LIQUID PORT
OUTLET PORT
3/8" 3/8"
HIGHHIGH
PRESSURE
PRESSURE
(25,000 PSIGPSIG
(25,000 MAX)MAX)
7.00 7.00
[178 [178
mm] mm] 5.78 5.78 11.3611.36
[147 [147
mm] mm] [288 [288
mm] mm] 4X MOUNTING HOLES
4X MOUNTING HOLES
8.25 8.25 n 9/16"
n 9/16"
[210 [210
mm] mm]
Model
Models8HSFD-25
Models 8HSFD-25,
8HSFD-25,8FD-25,
8FD-25,8SFD-25
8SFD-25
Inlet,
Inlet,Outlet
Inlet, Outletports
Outlet ports3/8’’
ports 3/8’’HP
3/8” HP
Models8DSFD-25
Models 8DSFD-25&&8DSTVD-25
8DSTVD-25
Model
Model8SFD-40
8SFD-40
Model
Model8SFD-65
8SFD-65
www.haskel.com
www.haskel.com
www.haskel.com25 2
8 h8p h( 5
p. 9
(57. 9
k7Wk
)WPu
) m
Pup mMpo d
Meold
s e(lc
so(ncto. )n t . )
2X HYDRAULIC2XOUTLET
HYDRAULIC OUTLET
1" NPT PORT 1" NPT PORT
11.10 in [282 mm]
11.10 in [282 mm]
10.17 in [258 mm]
10.17 in [258 mm]
ModelModel
8SFD2-55
8SFD2-55
2X HYDRAULIC2XOUTLET
HYDRAULIC OUTLET
1" NPT PORT 1" NPT PORT
11.10 in [282 mm]
11.10 in [282 mm]
10.17 in [258 mm]
10.17 in [258 mm]
ModelModel
8SFD2-88
8SFD2-88
www.haskel.com
26 www.haskel.com
HYDRAULIC
HYDRAULIC
HYDRAULIC
OUTLET
OUTLET
OUTLET HYDRAULIC
HYDRAULIC
HYDRAULIC OUTLETOUTLET
OUTLET
3/8
3/8HP
HP
3/8PORT
PORT
HP PORT 3/8 3/8PORT
3/8HP
HP HP PORT
PORT
(MAWP:
(MAWP:
(MAWP:
29,000
29,000
29,000
PSI)
PSI) PSI) (MAWP:
(MAWP:
(MAWP: 29,00029,000
29,000 PSI) PSI)
PSI)
HYDRAULIC OUTLET HYDRAULIC OUTLET
3/8 HP PORT 3/8 HP PORT
(MAWP: 29,000 PSI) (MAWP: 29,000 PSI)
HYDRAULIC
HYDRAULIC
HYDRAULIC INTLETINTLET
INTLET HYDRAULIC
HYDRAULIC
HYDRAULIC INLET
INLETINLET
1/2 1/2 PORT
1/2NPT
NPT NPT
PORTPORT 1/2 1/2 PORT
1/2NPT
NPT NPT
PORT PORT
(MAWP:
(MAWP:
(MAWP: 10,00010,000
10,000 PSI) PSI)
PSI) (MAWP:
(MAWP:
(MAWP: 10,00010,000
10,000 PSI) PSI)
PSI)
HYDRAULIC INTLET 88XX .85.X
533inin.[51[1333inmm[m1m]3] mm] HYDRAULIC INLET
1/2 NPT PORT (MOUNTING
(MOUNTING
(MOUNTING HOLES)
HOLES) HOLES) 1/2 NPT PORT 9.65
9.65in9.65
in[245inmm]
[245 [245
mm] mm]
(MAWP: 10,000 PSI) (MAWP: 10,000 PSI)
8X .53 in [13 mm]
(MOUNTING HOLES) 9.65 in [245 mm] AIR
AIRDRIVE
AIR DRIVE
DRIVE INLETINLET
INLET
3/4
3/4NPT
3/4 NPT
NPT
AIR DRIVE INLET
3/4 NPT
11.10
11.1011.10
inin[282inmm]
[282 [282
mm] mm]
10.1710.17
10.17 inin[258inmm]
[258 [258
mm] mm]
11.10 in [282 mm]
10.17 in [258 mm]
4.88
4.88in4.88
in[124inmm]
[124 [124
mm] mm]
18.11
18.1118.11
inin[460inmm]
[460 [460
mm] mm] 4.25
4.25in4.25
in[108inmm]
[108 [108
mm] mm]
18.11 in [460 mm] 4.25 in [108 mm]
19.55 inin[496
19.5519.55 inmm]
[496 mm] mm]
[496 7.00in7.00
7.00 in[178inmm]
[178 [178
mm] mm]
19.55 in [496
35.78
35.78 mm]
inin[909
35.78 inmm]
[909 mm] mm]
[909 7.00 in [178 mm]
35.78 in [909 mm]
8.25
8.25in8.25
in[210inmm]
[210 [210
mm] mm]
37.78
37.7837.78
inin[960inmm]
[960 [960
mm] mm] 8.25 in [210 mm]
37.78 in [960 mm]
Model
Model
Model8SFD2-224
8SFD2-224
8SFD2-224
Model 8SFD2-224
111
0001hh
h0p
pph(( p
7
(7
7 .. 4
4
(. 7
4
6.64
6 k6
k k
WW
W )k) W
)P
PuP
)um
u
m
Pmu
ppm
pM
MpM
oodo
ded
M e
ole
ldsl e
s sl s
Model
Model
Model
ModelD14STD-125
D14STD-125
D14STD-125
D14STD-125
Model D14STD-315
www.haskel.com 27
Model
Model
ModelD14STD-315
D14STD-315
D14STD-315
www.haskel.com
www.haskel.com
www.haskel.com
www.haskel.com
27
For more information on our high-pressure products,
visit Haskel.com or contact your local Haskel representative.
is part of Ingersoll Rand. Ingersoll Rand (NYSE:IR) advances the quality of life by creating
comfortable, sustainable and efficient environments. Our people and our family of brands— including
Club Car®, Ingersoll Rand®, Thermo King® and Trane®—work together to enhance the quality and
comfort of air in homes and buildings; transport and protect food and perishables; and increase
industrial productivity and efficiency. We are committed to a world of sustainable progress and
enduring results.