Main features:
• Drive forces up to 264N for upper axis • One flat cable per axis for
and 603N for lower axis all connections
• Mechanical stroke up to 308mm • Optical measurement system
• Speed up to 1,5m/s with integrated limit switches
• Acceleration up to 30m/s2 • Precision cross roller rail guides
• Ironless linear motor: with patented Anti cage Creeping
no attraction forces, System (ACS)
no cogging forces • Available in aluminum and cast iron
• Moving magnets for easier cabling • Ideal suited for wafer processing
(no moving cables to top part) and measurement applications

Dynamical and electrical parameters

Stroke mm (1) 92 164 236 308


Motor Motor Moving mass AI (GG25)
upper lower
axis axis
Fp Fn Ip In Up
Kg (4) N (2) Aeff Vp (2)
TLM300 .72 4,7 (11) 5,1 (11) 5,6 (12) 66 23 3,7 1,3 49
.144 5,6 (12) 5,6 (12) 6,0 (12) 133 46 5,7 2,0 63
.216 6,0 (12) 6,0 (12) 6,4 (13) 199 96 5,7 2,0 95
.072 8,3 (20) 8,3 (20) 8,7 (20) 66 23 3,7 1,3 49
.144 8,9 (20) 8,9 (20) 9,3 (21) 133 46 5,7 2,0 63
.216 9,4 (21) 9,4 (21) 9,8 (21) 199 96 5,7 2,0 95

TLM400 .144 10 (25) 11 (25) 11 (26) 133 46 5,7 2,0 63


.216 11 (25) 11 (26) 12 (26) 199 69 5,7 2,0 95
.288 11 (26) 12 (26) 12 (27) 264 92 5,7 2,0 126
.144 15 (37) 16 (38) 16 (38) 307 65 7,6 2,6 101
.216 16 (38) 16 (38) 17 (39) 460 97 11,4 3,9 100
.288 17 (38) 17 (39) 17 (39) 603 124 11,5 4,0 127
Note:
1. The indicated value is the mechanical
stroke. The electrical stroke = mechanical
stroke – 2x10mm. The electrical stroke is
set with optical limit switches, integrated
in the length measurement system. The
linear motors have reduced propulsion
forces when operating between the end
switches and the end stop.
2. The displayed peak force, peak current
and DC link voltage values should be
multiplied by 1,2 to allow sufficient
amplifier headroom. The displayed voltage
U (DC link voltage) is valid for a speed of
1m/s at a force Fp.
3. GG25 is cast iron, to be used when
maximum running accuracy and tempera-
ture stability is required (see also table
below). To get the real moving mass of the
lower axis, the top axis value should be
added to the lower axis value.
4. The indicated value is the mechanical
stroke. The electrical. Valid for the largest
possible stroke, with the upper and lower
axis both in centre position.
5. Valid for 100mm stroke. For 200mm Position feedback and limit switches switches have a galvanic isolated PNP/NC
stroke Tz +1 (1) and Ty +0,5 (0,25). The optical length measurement system (standard) or NPN/ NC output signal. The
has standard a pitch of 20µm and an limit switch supply voltage is 10 - 30V DC.
output signal of 1Vpp. A TTL output signal The limit switch position, as well as the
with a resolution up to 0,1µm is available measurement system status are indicated
upon request. The standard accuracy class on the system by 3 LEDs per axis.
is 3µm. The integrated optical limit

Mechanical parameters

Model Weight bottom Stage Min. outer Max. outer Through hole Height Height/ Side Perpen-
part Al (GG25) dimensions dimensions dimensions dimensions accuracy dicularity
Al (GG25)
B1 x B2 D1 x D2 H Tz / Ty
Kg mm (5) µm(6) mrad
TLM300 6 (16) 300 x 300 338 x 357 432 x 432 208 x 208 109 6 / 5 (5 / 4) 0,03
TLM400 13 (34) 400 x 401 438 x 468 576 x 576 275 x 255 145 6 / 5 (5 / 4) 0,03

SKF Linearsysteme GmbH ® SKF is a registered trademark of the SKF Group.


DE-97424 Schweinfurt, Germany
E-mail [email protected] © SKF 2005
The contents of this publication are the copyright of the publisher and may not be reproduced
(even extracts) unless prior written permission is granted. Every care has been taken to ensure
the accuracy of the information contained in this publication but no liability can be accepted for
any loss or damage whether direct, indirect or consequential arising out of the use of the
Publication Lf29EN 2/0505 information contained herein.

You might also like