Classification of Reaction To Fire
Classification of Reaction To Fire
Classification of Reaction To Fire
EFECTIS ERA AVRASYA TEST VE BELGELENDİRME A.Ş.
Fire Test Laboratory
Accredited Body
Nr: AB‐0556‐T
CLASSIFICATION OF REACTION TO FIRE
IN ACCORDANCE WITH EN
13501‐1:2018
Sponsor : HİS YALITIM İZOLASYON İNŞAAT MADENCİLİK SAN. VE
TİC. LTD. ŞTİ.
İncesu O.S.B. Sultansazı Mah. 2. Cad. No: 11, Melikgazi,
Kayseri, TURKEY
Prepared by : EFECTIS ERA AVRASYA TEST VE BELGELENDİRME A.Ş.
DİLOVASI OSB MAH. FIRAT CAD. NO: 18 DİLOVASI,
KOCAELİ, TURKEY
Product name : Terrawool Insulation Boards
:
Classification : ERA – 20 – 219
report No.
Issue Number : 1/2
Date of issue : 26.12.2020
This classification report consists of 5 pages and may only be used or
reproduced in its entirety.
Address: Dilovası OSB Mah. Fırat Cad. No: 18 Dilovası, KOCAELİ, TURKEY
Tel: 0262 6581662 Fax: 0262 6581669 E‐mail: [email protected]
Web: www.efectis.com
REACTION TO FIRE CLASSIFICATION REPORT No. ERA‐20‐219 Page 2
1. INTRODUCTION
This classification report defines the classification assigned to “Terrawool Insulation
Boards” in accordance with the procedures given in EN 13501‐1:2018
2. DETAILS OF CLASSIFIED PRODUCT
2.1. General:
Terrawool Insulation Boards is defined as a “type of classified product“. Its classification
is valid for the following end use application:
EN 14303:2009+A1:2013: Thermal insulation products for building equipment and
industrial installations ‐ Factory made mineral wool (MW) products ‐ Specification
2.2. Description:
Terrawool Insulation Board TW150 and Terrawool Insulation Board TWCT50 are fully
described in the test reports in support of the classification listed in clause 3.
Manufactured Plant: HİS YALITIM İZOLASYON İNŞAAT MADENCİLİK SAN. VE TİC. LTD. ŞTİ.
İncesu O.S.B. Sultansazı Mah. 2. Cad. No: 11, Melikgazi, Kayseri, TURKEY
Tested product types:
Surface coating
Organic
Density Thickness matter Mass per
Product Name Thickness
[kg/m3] [mm] content Type unit area
[kg/m3] [µm]
[g/m2]
TERRAWOOL INSULATION Black glass
50 50 1,5 60 30
BOARD TWCT50 tissue
TERRAWOOL INSULATION
150 50 5,55 Uncoated
BOARD TW150
3. REPORTS AND RESULTS IN SUPPORT OF CLASSIFICATION
3.1. Reports
Test method and date
Name of laboratory Name of sponsor Report ref. no.
Field of application rules and date
FTST20770 EN ISO 1716:2018
EFECTIS ERA HİS YALITIM İZOLASYON EN ISO 1182:2020
FTST20771
AVRASYA TEST VE İNŞAAT MADENCİLİK SAN.
BELGELENDİRME A.Ş. VE TİC. LTD. ŞTİ. FTST20772 EN 13823:2020
FTST20773 EN ISO 1716:2018
REACTION TO FIRE CLASSIFICATION REPORT No. ERA‐20‐219 Page 3
3.2. Results
Results
Number of
Test method Parameter Continuous Compliance
test
parameter mean parameters
FIGRA0,2 MJ (W/s) 3 0,0
(‐)
FIGRA0,4 MJ (W/s) 3 0,0
No
LFS > edge 3 (‐)
(‐)
EN 13823(1) THR600 s (MJ) 3 0,5
SMOGRA (m2/s2) 3 0,0 (‐)
TSP600 s (m2) 3 6,4 (‐)
Flaming droplet(s)/particle (s) 3 None None
PCS (MJ/kg)(a) 3 1,27 (‐)
PCS (MJ/kg) (b) 3 5,68 (‐)
EN ISO 1716(1)
PCS (MJ/m2) (b) 3 0,34 (‐)
PCS (MJ/kg) (c) 3 1,38 (‐)
EN ISO 1716(2) PCS (MJ/kg) 3 1,27 (‐)
T (°C) 5 7,4 (‐)
EN ISO 1182 (1) (2)
m (%) 5 1,70 (‐)
tf (s) 5 0,0 (‐)
(a): Stone wool
(1): Terrawool Insulation Board TWCT50
(‐): Not applicable (b): Black glass tissue
(2): Terrawool Insulation Board TW150
(c): The product as a whole
Test method Parameter Parameter Compliance parameters
FIGRA0,2 MJ [W/s] 0,0 ≤ 20 (A1)
LFS < edge (‐) Yes (A1)
THR600s [MJ] 0,5 ≤ 4 (A1)
EN 13823(1)
SMOGRA [m2/s2] 0,0 ≤ 30 (A1)
TSP600s [m2] 6,4 ≤ 50 (A1)
Flaming droplet(s)/particle (s) None None (A1)
(a)
PCS (MJ/kg) 1,27 ≤ 2 (A1)
(1)
EN ISO 1716 PCS (MJ/m2) (b) 0,34 ≤ 2 (A1)
PCS (MJ/kg) (c) 1,38 ≤ 2 (A1)
EN ISO 1716(2) PCS (MJ/kg) 1,27 ≤ 2 (A1)
T (°C)
7,4 ≤ 30 (A1)
EN ISO 1182 (1) (2)
m (%) 1,70 ≤ 50 (A1)
tf (s) 0,0 = 0 (A1)
(a): Stone wool
(1): Terrawool Insulation Board TWCT50
(‐): Not applicable (b): Black glass tissue
(2): Terrawool Insulation Board TW150
(c): The product as a whole
REACTION TO FIRE CLASSIFICATION REPORT No. ERA‐20‐219 Page 4
4. CLASSIFICATION AND FIELD OF APPLICATION
4.1. Reference of classification
This classification has been carried out in accordance with the clauses 11.8.2 of EN
13501‐1:2018
4.2. Classification
Terrawool Insulation Boards, in relation to its reaction to fire behaviour is classified:
A1
The additional classification in relation to smoke production is:
not classified
The additional classification in relation to flaming droplets / particles is:
not classified
The format of the reaction to fire classification for Terrawool Insulation Boards is:
4.3. Extended field of application
This classification is valid for the following product parameters:
Surface coating
Organic
Density Thickness matter Mass per
Product Name Thickness
[kg/m3] [mm] content Type unit area
[kg/m3] [µm]
[g/m2]
Black glass
≤ 50 ≤ 50 ≤ 1,5 60 30
Terrawool Insulation tissue
Boards
Without Without
≤ 5,55 Uncoated
limitation limitation
REACTION TO FIRE CLASSIFICATION REPORT No. ERA‐20‐219 Page 5
5. LIMITATIONS
5.1. Restrictions
This classification report is valid provided that the technical specifications of product are
within the limits in accordance with the field of application clause 4.3.
5.2. Warning
This classification document does not represent type approval or certification of the
product.
Signed: Approved:
........................................ ........................................
Uğur ÇAVAŞ Ali BAYRAKTAR
Person in the charge of tests Laboratory Manager