ESP Price List 01 May 2022
ESP Price List 01 May 2022
ESP Price List 01 May 2022
Contactors 03
Accessories 08
Spares 11
Motor Protection Solutions
Thermal Overload Relays 12
Electronic Motor Protection Relays 14
iMMR – Intelligent Motor Management Relay 16
Motor Protection Circuit Breakers 18
Starters
Motor Starters 20
Powergear
Enclosed Automatic Transfer Switch 25
On Load Changeover Switch-Disconnectors 26
CZ Bypass Switch & Switch Disconnectors New 27
Switch-Disconnector-Fuse Units, HRC Fuses & SDs 30
Moulded Case Circuit Breakers 35
Sub - Main Distribution Boards 48
Air Circuit Breakers 52
Energy Management
Power Quality Solutions 65
Protection Relays 73
Metering Devices 75
Energy Management Solution 76
Automation Solution
AC Drives 84
Digital Soft Starters 88
Programmable Logic Controllers (PLC) & Human Machine Interface 93
Final Distribution Products 95
Discontinued Products/Suggested Alternate Products 112
Note:
[Green colour : HSN code]
Current GST 18%, subject to changes as per Govt. notification
Please contact the nearest branch office for
Prices of the following products :
l Rotary Switches
MI Contactors
6-150A, AC-3 Rating
Optimum solution
for your applications
Understanding customer requirements, we make sure that our range of contactors caters to their evolving needs.
Considering the changing expectations of customers and a need for an optimum and reliable solution, we introduce
MI range of contactors for applications upto 150 A AC3 rating.
Features : M.R.P.
• Finger proof terminals upto 40A Type Cat. No. (`)
Per Unit
• Can be used with existing MN Range of thermal overload relays
MI 6 (With 1 NO aux contact) CS90401
• Top mounting add-on blocks possible upto 80A MI 9 (With 1 NO aux contact) CS90402
• Spares available for entire range MI 12 (With 1 NO aux contact) CS90403
• Optimised for AC1/AC3 applications MI 18 (With 1 NO aux contact) CS90404
MI 22 (With 1 NO aux contact) CS90405
Applications : MI 25 CS90406
• Street lighting MI 32 CS90407
Price
• VFD, Soft Starters applications MI 40 CS90408 on
request*
• UPS MI 45 CS90704
* For accessories and more details please contact nearest branch. MI 150 CS90726
Notes:
1) Standard coil voltage: 110V, 220V, 240V and 415V, 50Hz
2) For ordering Suffix, please refer page No. 10
Vacuum Contactors $
[8536]
Notes:
1) # Add-on blocks can be ordered separately 3 Pole Vacuum Contactors - Type MVO
2) For ordering MNX/MO/MVO add-on aux contact blocks, please refer page No. 8 Features
3) For ordering MNX/MO surge suppressor and MNX/MO MIL kit,
l Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1
please refer page No. 9
l Range from 400 – 820A AC-3
4) For ordering Suffix, please refer page No. 10
l With contact erosion indicator
5) Standard coil voltage: MNX/MO - 110V, 220V, 240V and 415V, 50Hz.
l Wide band potted coil with built-in surge suppressor
If using 16 sq mm cable for MO 45 use of spreader link kit is mandatory l Coil on top design
For ordering spreader link kit for MO 45, Please refer page No. 9 l RoHS compliant MVO 820
Universal AC/DC electronic coil version
AC3 AC1 M.R.P. Std.
Rating Rating Type Aux. Pkg.
Cat. No. (`)
(A) (A) Contacts (Nos.)
Per Unit
400 630 MVO 400 2 NO + 2 NC CS90097 190605 1
500 630 MVO 500 2 NO + 2 NC CS90098 247350 1
630 820 MVO 630 2 NO + 2 NC CS90099 314340 1
820 1000 MVO 820 2 NO + 2 NC CS90077 475765 1
MX 06 ML 1.5 ML 3 ML 6 ML 12
AC3 AC1 M.R.P. Std. AC3 AC1 M.R.P. Std.
Rating Rating Type Aux. Pkg. Rating Rating Type Aux. Pkg.
Cat. No. (`) Size Cat. No. (`)
(A) (A) Contact (Nos.) (A) (A) Contacts
Per Unit Per Unit (Nos.)
For AC control (Std. Coil Voltage - 24, 110, 240, 415V, 50Hz) Fr 1 25 25 ML 1.5 2 NO + 2 NC SS91851 4280 1
6A 20A MX 06 1 NO CS94012 1175 10 32 40 ML 2 2 NO + 2 NC SS90701 7945 1
Fr 2
6A 20A MX 06 1 NC CS94013 1175 10 40 45 ML 3 2 NO + 2 NC SS90721 11730 1
9A 20A MX 09 1 NO CS94014 1215 10 70 100 ML 4 2 NO + 2 NC SS90910 19175 1
Fr 3
9A 20A MX 09 1 NC CS94015 1215 10 110 125 ML 6 2 NO + 2 NC SS90921 30270 1
12A 20A MX 12 1 NO CS94016 1325 10 Fr 4 300 400 ML 12 2 NO + 2 NC SS91010 68565 1
12A 20A MX 12 1 NC CS94017 1325 10
For DC control (Std. Coil Voltage - 24, 110, 220V) Notes:
6A 20A MX 06 1 NO CS94021 1840 10 1) For ordering MX add-on aux contact blocks, please refer page No. 8
6A 20A MX 06 1 NC CS94022 1840 10 2) For ordering ML add-on aux contact blocks, please refer page No. 9
3) For ordering MX surge suppressor and MIL kit, please refer page No. 9
9A 20A MX 09 1 NO CS94023 1890 10
4) For Ordering Suffix, please refer page No. 10
9A 20A MX 09 1 NC CS94024 1890 10 5) Standard Coil Voltage : ML 1.5/2/3 - 110V, 240V and 440V, 50 Hz
12A 20A MX 12 1 NO CS94025 2040 10 ML 4/6/12 - 110V, 240V and 415V, 50 Hz
12A 20A MX 12 1 NC CS94026 2040 10
For DC control std. Coil Voltage - 24, 110, 220V Note: 1) 6NC & above combination is not recommended for MO0 AC
2) 5NC & above combination is not recommended for MO0 DC
MX0 40E (4 NO) CS94027 1905 10
AC-15
MX0 31E (3 NO + 1 NC) CS94028 1905 10 DC Control Contactor - MN0 ($)
4A MX0 22E (2 NO + 2 NC) CS94029 1905 10 Rated Description M.R.P. (`) Std. Pkg.
at 415V Cat. No.
MX0 13E (1 NO + 3 NC) CS94043 1905 10 Current Per Unit (Nos.)
MX0 04E (4 NC) CS94044 1905 10 For DC control std. Coil Voltage - 24, 110, 220V
MN0 40E (4 NO) SS94665 2085 10
Notes:
1) For Ordering Suffix, please refer page No. 10 MN0 31E (3 NO + 1 NC) SS94666 2085 10
AC-15
2) 5 NC & above combinations are not recommended for MX0 DC Control Contactors 4A MN0 22E (2 NO + 2 NC) SS94667 2085 10
3) 1 NO + 3 NC, 4 NC add on block combinations are not recommended for MX0 DC at 415V
Control Contactors. For Example, In MX0 DC control Contactors, 4NO + 4NC MN0 13E (1 NO + 3 NC) SS94668 2085 10
combination can be achieved with 2NO + 2NC aux contactor and 2NO + 2NC MN0 04E (4 NC) SS94669 2085 10
add on block and not with 4NO standalone contactor and 4NC add on block
4) For ordering add-on contact blocks of MX0, MO0 & MN0 please refer page No. 8 $ - Available till stock lasts
Note: Note:
1) Ordering Suffix BOOO - 240V, 50Hz 1) Coil voltages available for MU-2P are 220V, 240V, wide band coil 160-220V
2) For ordering add-on aux. contact block, please refer page No. 9 2) Ordering suffix for wide band coil of MU-2P is NOOO
3) For ordering add-on aux. contact block, please refer page No. 8
Note: 1) Mounting of side add-on aux. contact block is not recommended for mechanically interlocked MCX 11/12/13 contactors
2) Accessories are common for MNX 2P & MNX 3P contactors
Front Mounting
Add-on aux. Contact Block
# For MDX Side add-on and top add-on can not be mounted together
Side Mounting
Add-on aux. Contact Block
MNX/MCX MO/MO C
Side Add-on aux. contact Block Left Add-on aux. contact Block
Suitable for
Side M.R.P. M.R.P. M.R.P. M.R.P.
Mounting Aux MNX 9-40 / MCX MNX 50-80 / MO 9-110/
(`) (`) (`) (`)
Contact MCX 01-04 11-13 MCX 22-23 MO C 3-100
Per Unit Per Unit Per Unit Per Unit
First left 1 NO + 1 NC CS94220^ 635 CS94201^ 680 CS94201^ 680 CS94580^ 635
First Right 1 NO + 1 NC CS94221^ 635 CS94202^ 680 CS94202^ 680 CS94581^ 635
Second Left 1 NO + 1 NC CS94203^ 680 CS94582^ 635
Second right 1 NO + 1 NC CS94204^ 680 CS94583^ 635
Note: Mounting of side add-on aux. contact block is not recommended for mechanically interlocked MCX 11/12/13 contactors
For MO 9-18, only First left and Second left side add-on is allowed.
Side Mounting
Add-on aux. Contact Block
MO MDX
Left Add-on aux. contact Block Side Add-on aux. contact Block
Suitable for
Side M.R.P. M.R.P. M.R.P. M.R.P.
Mounting Aux MNX 95-650/ MO MVO MDX#
(`) (`) (`) (`)
Contact MCX 32-47 140-300 400-820 9-110
Per Unit Per Unit Per Unit Per Unit
First left 1 NO + 1 NC CS94205^ 775 CS95033^ 775 CS91208^ 775
ST94985^ 935
First Right 1 NO + 1 NC CS94206^ 775 CS95034^ 775 CS91209^ 775
Second Left 1 NO + 1 NC CS94207^ 775 CS95035^ 775 CS95035^ 775
Second right 1 NO + 1 NC CS94208^ 775 CS95036^ 775 CS95036^ 775
# For MDX Side add-on and top add-on can not be mounted together
~ Standard Packing is 1 ^Standard Packing is 10 ^^Standard Packing is 20
Note:
1) Ordering Suffix for Mechanical Interlock Kits : OOOO
2) * MO MIL Kit contains inbuilt 2 NC Contacts
3) Mounting of side add-on aux. contact block is not recommended for mechanically interlocked MCX 11/12/13 contactors
4) MIL kit for MNX 50-80 comes with 2 left & 2 right side add-on aux. contact blocks i.e. 4 NO + 4 NC
5) MIL kit for MCX 22/23 comes with 2 left & 2 right side add-on aux. contact blocks i.e. 4 NO + 4 NC
MOG H1/S1 with MO 9-18 CS90396 # 395 10 MOG H1/S1 with MO 9-18 CS90548 # 995 10
MOG H1/S1 with MO 25-45 CS90391 # 395 10 MOG H1/S1 with MO 25-45 CS90546 # 995 10
M.R.P. Std.
Suitable For Cat. No. (`) Pkg.
Per Unit (Nos.)
# Ordering Suffix OOOO
MOG H1/S1 with MO 9-18 CS90549 # 1195 10
For MPCB paralleling link
MOG H1/S1 with MO 25-45 CS90547 # 1195 10 refer page no.19
l Ideal for logical operations MO 9-70A, MO 0 control Mechanical Latch CS90136 2650 10
l Suitable for sites where voltage fluctuation is frequent
l Saves energy as coil supply can be removed once For Ordering Suffix refer below table
contactor is picked up Standard Coil Voltage of Mechanical Latch is 24V AC, 110V AC & 240V AC
MO Contactors
ML 6 SS95313^ 18680
ML 10 SS95315~ 38055 MO 70 CS96389^~ 4845
SS91011 ~ 6785 MO 80 CS96390^~ 6665
ML 12 SS95317~ 41020
MO 95 CS96391^~ 8410 CS96319^ 3090
MR - - CS94102 ^ 665
MO 110 CS96392^~ 12300
MU16-2P CS90217^ 275
MO 140 CS90357~ 14795
MU25-2P CS90218^ 360 CS90793 ^ 365
MO 185 CS90358~ 17700 CS90356~ 7170
MU40-2P CS90219^ 525
MO 225 CS90359~ 20300
MO 0 AC - - CS94841 ^ 475
MO 250 CS94444~ 24395
MN 0 AC - - SS94191 ^ 765 CS94442~ 10685
MO 300 CS94443~ 27545
MN 0 DC - - SS94651 ~ 1420 MO 140 (electronic coil) CS90357~ 14795
MO 185 (electronic coil) CS90358~ 17700 CS90855~ 12935
Note:
1) Coil voltages available for MU-2P are 220V, 240V, wide band coil 160-220V MO 225 (electronic coil) CS90359~ 20300
2) Ordering suffix for wide band coil of MU-2P is NOOO MO 250 (electronic coil) CS94444~ 24395
CS90738~ 13065
MO 300 (electronic coil) CS94443~ 27545
MVO - - CS90174~ 29030
MO C Spare Coils MNX 9 CS94123^ 530
M.R.P. MNX 12 CS94124^ 685
Type Cat. No. (`) MNX 18 CS94125^ 750
Per Unit
MO C3 - 30 CS96317^ 590 MNX 22 CS94269^ 795 CS94105^ 475
MNX 25 CS94127^ 860
MO C40 - 60 CS96318^ 1785
MNX 32 CS94128^ 1950
MO C75 - 100 CS96319^ 3090
MNX 40 CS94147^ 3295
MNX 50 CS94150^ 3370
MNX Contactors
ML 4/ ML 6 ST28735 ~
1990 MCX 13 CS90307^ 5155
MCX 22 CS94331~ 6040
Combination coil with timer ST91291* ~ 1575
MCX 23 CS90078~ 7555
MCX Contactors
M.R.P.
Type Cat. No. (`) MCX 32 CS94082^ 11690
~
Per Unit MCX 33 CS94083^ 15120 CS94196 3090
ML 2 SS90650~ 3765 MCX 34 CS94084^ 17140
Note :
MCX 41 CS94295~ 26790
1) Ordering Suffix for Spare Contact kit - OOOO MCX 42 CS94296~ 31465
CS94195
~
10685
2) For Spare Coil Ordering Suffix refer page No. 10 MCX 43 CS94297~ 37750
MCX 44 CS94298~ 46240
~ Standard Packing is 1 MCX 45 CS94299~ 49370
^~ Standard Packing is 5 MCX 46 CS94300~ 57360 CS94193
~
21650
^ Standard Packing is 10 MCX 47 CS90308~ 77540
~~ Standard Packing is 50
* Ordering Suffix for 240V AC - FOOO, 415V AC - ROOO
L&T Electrical & Automation, ESP 01.05.2022 11
Ther mal Overload Relays [8536]
Type MN - Suitable for MNX Contactor Type RTO - Suitable for MO Contactor
Features Features
l Available in 3 frame sizes from 0.2-570 A l Ambient temperature compensated upto 55oC
l Ambient temperature compensated up to 55оC l Built-in Single Phasing protection
l Built-in Single Phasing protection l Manual and auto reset mode
l Manual and auto reset mode l Front access to START and STOP/RESET buttons
l Conforms IS/IEC 60947-4-1 & IEC 60947-4-1 l Sealable in OFF condition
l Conforms IS/IEC 60947-4-1 & IEC 60947-4-1
Type of Mounting Relay Range M.R.P. Std. Type of Mounting Relay Range M.R.P. Std.
Cat. No. (`) Pkg. Cat. No. (`) Pkg.
(Operation) (A) (Nos.) (Operation) (A) (Nos.)
Per Unit Per Unit
MU 2P (2 Pole) MU 2P (2 Pole)
1 - 1.6A CS90207OOMO 695 1 11 - 18A CS90207OOCO 775 1
Direct 1.5 - 2.5A CS90207OOPO 695 1 Direct 13 - 22A CS90207OODO 775 1
Mounting on 2.5 - 4A CS90207OORO 695 1 Mounting on 16 - 26A CS90207OOBO 775 1
MU-2P Contactor 4 - 6.5A CS90207OOTO 695 1 MU-2P Contactor 20 - 32A CS90207OOEO 970 1
6 - 10A CS90207OOVO 695 1 26 - 40A CS90207OOFO 970 1
9 - 14A CS90207OOAO 695 1
Relay Mounting Kit Kit for Mounting MN5 Relay Din Rail Mounting Kit
MN2 Relay 400 mm 650 mm 900 mm 1200 mm
Kit for Mounting MN 5 Relay on MN Relay reset cord - 1200mm SB94210OOOO 935 1
MNX 95 / 110 / 140 contactor SS94638OOOO 345 20
RTO Relay reset cord - 400mm CS90941OOOO 780 1
Kit for Mounting MN 5 Relay on
ML 2 / ML 3 contactor SS94151OOOO 225 20
RTO Relay reset cord - 650mm CS90942OOOO 810 1
Kit for Mounting MN5 Relay on
ML 4 / ML 6 contactor SS94152OOOO 305 20 RTO Relay reset cord - 900mm CS90943OOOO 835 1
DIN Rail Mounting Kit Relay on
MN 2 Relay SS91887OOOO 165 50 RTO Relay reset cord - 1200mm CS90944OOOO 935 1
M.R.P. Std.
Description Cat. No. (`) Pkg.
Per Unit (Nos.)
Separate Mounting Kit for RTO-1 Relay Separate Mounting Kit CS96335OOOO 290 1
RTO Relay RTO-2 Relay Separate Mounting Kit CS96306OOOO 690 1
MPR200nX MPR300
Electronic Motor Protection Relay Electronic Motor Protection Relay
With in-built Earth Fault Protection
• Protections: • Protections:
- Overload - Overload
- Locked Rotor - Earth Fault
- Single Phasing, Current Unbalance, - Locked Rotor
Phase Sequence Reversal - Single Phasing, Current Unbalance,
- Under Current Phase Sequence Reversal
• Inbuilt CT’s (1 A to 88 A)
- Under Current
• Trip indication
• Inbuilt CT’s (1 A to 88 A)
• Test facility
• Trip indication
• Selectable trip class - 10A, 10, 20 and 30
as per IEC 60947-4-1 • Test facility
• Selectable trip class - 10A, 10, 20 and 30
as per IEC 60947-4-1
Note: MPR200nX / MPR300 must sense Line current in case of Star-Delta Starter.
M.R.P.
Model Aux. Supply Thermal Over load range Device Code Cat. No. (`)
Per Unit
3Ø
Motor New
3Ø
MC2 - 30M / MC2 - 30MW
Motor
Accurate Cloud
real time data computing
Display Unit
iMMR - Intelligent Motor
Management Relay
Features
• Comprehensive Current & Voltage based Protections
• 20 nos. of last trip records, 100 event records and 20 IRF Records
are available
M.R.P.
Product Description Cat. No. (`)
Per Unit
Selection Guide
Rocker type and Rotary Type Motor Protection Circuit Breaker conforms to IEC 60947-4-1 & 60947-2
R
Y
B
Breaking capacity: Icu = 100kA upto 10A, Icu = 50kA for 13A & Breaking capacity: Icu = 100kA upto 13A & Icu = 50kA from 16A - 32A
Icu = 25kA for 16-32A
Type MOG-H1M (Rotary Type) - Frame 1 Type MOG-H2 (Rotary Type) - Frame 2
With short circuit protection only With short circuit & overload protection
Short Circuit Auxiliary + Alarm Extended Shunt Trip MPCBs with bus bar Connecting 3 Phase Feed
Alarm Rotary Handle connection Busbar link in terminal
M.R.P. Std.
Mounting M.R.P. Std. Description Cat. No. (`) Pkg.
Position Description Cat. No. (`) Pkg. Per Unit (Nos.)
* Per Unit (Nos.)
Connecting Busbar link
F1/F2 Auxiliary Contact Front mtg. 1NO ST41942OOOO 500 10 2 MPCB 45 mm width w/o acc ST41957OOOO 580 5
F1/F2 Auxiliary Contact Front mtg. 1NC ST41943OOOO 500 10 3 MPCB 45 mm width w/o acc ST41958OOOO 640 5
L Auxiliary Contact Left side mtg. 2NO ST41944OOOO 695 1 4 MPCB 45 mm width w/o acc ST41959OOOO 690 5
Auxiliary Contact Left side mtg. 5 MPCB 45 mm width w/o acc ST41960OOOO 880 5
L ST41945OOOO 695 1
1NO + 1NC 2 MPCB 45 mm width with one acc 9 mm ST41961OOOO 680 5
L Auxiliary Contact Left side mtg. 2NC ST41946OOOO 695 1 3 MPCB 45 mm width with one acc 9 mm ST41962OOOO 735 5
F2 Trip Alarm Contact Front mtg. 1NO ST41947OOOO 895 10 4 MPCB 45 mm width with one acc 9 mm ST41963OOOO 790 5
F2 Trip Alarm Contact Front mtg. 1NC ST41948OOOO 895 10 5 MPCB 45 mm width with one acc 9 mm ST41964OOOO 845 5
L Auxiliary + Alarm Left side mtg. 2NO ST41949OOOO 955 1 2 MPCB 55 mm width w/o acc ST41966OOOO 1060 1
Short circuit alarm Left side mtg. 3 MPCB 55 mm width w/o acc ST41967OOOO 1210 1
L ST41950OOOO 955 1
1NO + 1NC 4 MPCB 55 mm width w/o acc ST41968OOOO 1450 1
R Shunt trip 24V DC ST41951OOOO 1830 1 2 MPCB 55 mm width with one acc 9 mm ST41969OOOO 1155 1
R Shunt trip 110V, 50Hz ST41952OOOO 1930 1 3 MPCB 55 mm width with one acc 9 mm ST41970OOOO 1305 1
R Shunt trip 230V, 50Hz ST42952OOOO 1930 1 4 MPCB 55 mm width with one acc 9 mm ST41971OOOO 1545 1
R Under Voltage release, 110V, 50Hz ST41953OOOO 1930 1 2 MPCB 55 mm width with two acc 18 mm ST41972OOOO 1350 1
R Under Voltage release, 415V, 50Hz ST41954OOOO 1930 1 4 MPCB 55 mm width with two acc 18 mm ST41973OOOO 1500 1
External operating handle, Feed in terminal for 45 mm width Busbar ST41965OOOO 680 1
- ST41955OOOO 1110 1
(Black) Frame 1 Feed in terminal for 55 mm width Busbar ST41974OOOO 1175 1
External operating handle, Bus bar safety cover 45 mm width Busbar ST41975OOOO 295 10
- ST41956OOOO 1110 1
(Black) Frame 2 Bus bar safety cover 55 mm width Busbar ST41976OOOO 315 10
* F1- Front left slot F2- Front right slot L- Left side R- Right side acc: Accessories
MN 16 MN 45 ML 3
Max. Motor Relay
M.R.P. Std.
Output at Max.
Description Cat. No. (`) Pkg.
415V, 3-Ph Range (Nos.)
Per Unit
HP kW (A)
10.0
15.0
7.5
11.0
9 - 15
14 - 23
MN 16 DOL
MN 25 DOL
SS94351
SS94352
4815
7360
1
1
Timers
20.0 15.0 20 - 33 MN 32 DOL SS94353 11875 1
30.0 22.5 30 - 50 MN 45 DOL SS94017 20315 1 Electronic Timers Type ST 100 [9107]
45.0 33.5 45 - 75 MN 65 DOL SS94018 27815 1
30.0 22.5 28 - 42 ML 3 DOL SS90722 24960 1
MN 16F ST 100
40.0 30.0 20 - 33 MN 32 FASD SS94366 29830 1 Note: ST 100 supplied with Mounting Kit, suitable for ET 100 replacement.
For Complete range of Timing Devices, please refer the Panel Accessories Price List.
50.0 37.5 30 - 50 MN 45 FASD SS94021 47910 1
All our type 2 charts are available on Knowledge Portal & ProductWhiz.
Charts available at Iq of
• 50kA
• 65kA
• 80kA
• 100kA
MCCB charts are available with
Microprocessor Releases too
Switch to ATS
Now, experience seamless transfer between two power sources…
Convenience Flexibility
• Ample Space for Cable Termination • Priority Source Selection
• Ease of Generator Control(ON-OFF, Cooling • Adjustable Time Delay(0.1sec to 3 hours)
Cycle Self-Test) • Suitable for 3-Phase as well as 1-Phase Sources
• Cyclic Event Logger: Logs 100 Events
Performance Safety
• Wide range: 125A to 630A, 415V ac. • Protections: UV/OV, Phase Sequence, Single Phasing,
• Double-Break Contact System offering High Frequency
Short-time Withstand (Icw) • Authorized Access Control through Password
• High Mechanical and Electrical Life: Double than Protection
requirement of IS/IEC standard • Terminal Shrouds, Phase Barriers & Source Separator
• Suitable for Aluminum Termination
Auxiliary Operating Handle Flip-able Handle Castell AST Controller with AuXC-2000 Controller Illuminated Push
Contact (63A to 200A) (250A to 2000A) Type Lock wire harness with wire harness Button assembly
M.R.P. Std. M.R.P. Std.
Description Type Cat. No. (`) Pkg. Description Type Cat. No. (`) Pkg.
Per Unit (Nos.) Per Unit (Nos.)
CO1-(63-125A) CX10002OOOO 450 1 Automatic AST Controller with wire harness CK90192OOOO 18880 1
Transfer b
CO2-(125-200A) CX20002OOOO 850 1 Controllers AuXC - 2000 Controller AuXC - 2000 ATC2000OOOO 30100 1
Auxiliary with wire harness
CO3-(250-315A) CX30002OOOO 1210 wire harness CK90099OOOO 3850 1
Contact Kit 1
(2 sets of Control Illuminated Push Button
CO4-(400-630A) CX40002OOOO 1290 1 CK90195OOOO 3840 1
C/O contact) Accessories assembly with Wire harness
CO5-(630-1000A) CX50002OOOO 1460 1
b Chapter ID [9032]
CO6-(1250-2000A) CX60002OOOO 1620 1
CO1-(63-125A) CX10001OOOO 740 1
Operating
Handle Kit
CO2-(125-200A) CX30001OOOO 1510 1
Fuse Mounting Kit [8538]
(handle + shaft + CO3-(250-315A) CK90392OOOO 1610 1
center bush +
bush clip) CO4-(400-630A) CX40001OOOO 1650 1
M.R.P. Std.
CO5-(630-1000A) CX50001OOOO 1770 1 Suitable Pkg.
Description Type Cat. No. (`)
fuse-link
Operating Handle CO6-(1250-2000A) Per Unit (Nos.)
CX60001OOOO 2010 1
HF 14x51 CO1-63 CX10630OOCO 2380 1
Castell Type CO-(125-1000A) CX40004OOOO 2660 1
HN Size 000 CO2-125 CX21250OODO 4650 1
Lock$ CO6-(1250-2000A) CX60004OOOO 2660 1
HN Size 00 CO2-160 CX21600OODO 6600 1
Output CO1-(63-125A) Top Side CX10005OOOT 780 1 HN Size 1 CO3-250 CX32500OODO 9030 1
shorting link Fuse
CO1-(63-125A) Bottom Side CX10005OOOB 780 1 Mounting HN Size 1 CO3-315 CX33150OODO 9450 1
C/O Frame 2 & 3 (125-315A) CK90374OOOO 1410 1 Kit HN Size 2 CO4-400 CX44000OODO 13570
Operating Handle 1
for Motorised C/O Frame 4 & 5 (400-1000A) CK90378OOOO 1770 1 HN Size 3 CO5-630 CX56300OODO 27320 1
Changeover HN Size 3 CO5-800 CX58000OODO 31080 1
C/O Frame 6 (1250-2000A CK90645OOOO 4400 1
$ Chapter ID [8301]
4P, Open Execution with extended handle Accessories for CZ Bypass switch
Rating M.R.P. Std. M.R.P. Std.
Frame 440Vac, Cat No. (`) Pkg. Frame Description Cat No. (`) Pkg.
AC 23A Per Unit (Nos.) Per Unit (Nos.)
CZ1 125A CK90813OOOO 17000 1 Auxiliary
CZ1/ Contact Kit*
CZ1 160A CK90814OOOO 17750 1 CK90805OOOO 485 1
CZ2 (1 C/O contact)
CZ1 200A CK90815OOOO 20250 1
Chapter ID [8538]
CZ1 250A CK90816OOOO 27000 1
* Upto 2 C/O contacts can be installed for status / indication
CZ1 315A CK90817OOOO 33000 1
Compact 2P, 3P & 4P configurations Extra assurance with visible contact system
1250Vac Insulation Voltage High electrical and mechanical life (double than
AC-23A @ 690Vac without derating requirement in IS/IEC standards)
Suitable for 50OC ambient temperature Terminal shrouds and phase barriers are provided as
standard offering along with the product
Direct termination without the need of any
extended links Higher ground clearance ensure safety at all times
Switching of Switching of VFD panels for switching Isolation in String Inverter Battery Charging
feeders in power Machinery/Motors and isolation of VFD as well as Central Inverter
distribution network (AC as well DC) Solar Systems
4P AC Switch Disconnector 4P AC Switch Disconnector in SS enclosure (with extended handle)
Rating M.R.P. (`) Std. Pkg. Rating M.R.P. (`) Std. Pkg.
Frame Handle Type CAT No. Frame CAT No.
690V, AC 23A Per Unit (Nos.) 690V, AC 23A Per Unit (Nos.)
CZ1 125A Extended CK90769OOOO 7400 1 CZ1 125A CK90819OOOO 13320 1
CZ1 160A Extended CK90770OOOO 9350 1 CZ1 160A CK90820OOOO 15430 1
CZ1 200A Extended CK90771OOOO 10890 1 CZ1 200A CK90821OOOO 17420 1
CZ1 250A Extended CK90772OOOO 12840 1 CZ1 250A CK90822OOOO 19900 1
CZ1 315A Extended CK90773OOOO 13600 1 CZ1 315A CK90823OOOO 21080 1
CZ2 315A Extended CK90857OOOO 15090 1 CZ2 315A CK90878OOOO 24900 1
CZ2 400A Extended CK90858OOOO 19310 1 CZ2 400A CK90879OOOO 29160 1
CZ2 630A Extended CK90859OOOO 24200 1 CZ2 630A CK90880OOOO 34120 1
CZ1 125A Direct CK90799OOOO 7100 1 Chapter ID [8536]
CZ1 160A Direct CK90800OOOO 8930 1
Accessories for CZ Switch Disconnector
CZ1 200A Direct CK90801OOOO 10350 1
Description M.R.P. (`) Std. Pkg.
CZ1 250A Direct CK90802OOOO 12200 1 Frame CAT No.
Per Unit (Nos.)
CZ1 315A Direct CK90803OOOO 12920 1 Auxiliary
CZ1/CZ2 Contact Kit CK90805OOOO 485 1
CZ2 315A Direct CK90872OOOO 14340 1 (1 C/O contact)
CZ2 400A Direct CK90873OOOO 18340 1 Chapter ID [8538]
CZ2 630A Direct CK90874OOOO 22990 1 Notes:
• 2P and 3P versions are also available. Please contact our nearest
Chapter ID [8536]
branch office for further details
• Separate versions suitable for DC applications (1000Vdc and 1500Vdc)
also available. Please contact our nearest branch office for further details
• Please refer next page for details on offerings for Solar applications
New
CZ Switch Disconnectors
• Designed for tough conditions at solar sites
• Separate versions for 800Vac string inverter systems and
upto 1500Vdc for central inverter systems
• Suitable for Aluminum termination of double the size recommended by IEC standards
• 1250Vac Rated Insulation Voltage
• Direct termination without the need of any extended links
• Terminal shrouds and phase barriers are provided as standard offering along with the product
AC SD DC SD
Operational Voltage Operational Voltage
upto 800Vac 1000Vdc & 1500Vdc
l Terminal Shrouds on both sides and l Terminal Shrouds on both sides and
Phase Barriers included Phase Barriers included
l Telescopic shaft for depth adjustment l Telescopic shaft for depth adjustment
l Door interlock & padlock facility l Door interlock & padlock facility
l FNX 4-Pole with in-built Neutral Link FNX TPN S-D-F FNX 4P S-D-F
Open Execution Type FNX (TPN) S-D-F Open Execution Type FNX (4P) S-D-F
Rated suitable for DIN fuse-link suitable for DIN fuse-link Std.
Suitable Range
Size Current M.R.P. Std. M.R.P. Pkg.
fuse-link type (A)
(A) Type Cat. No. (`) Pkg. Type Cat. No. (`) (Nos.)
Per Unit (Nos.) Per Unit
32 HF Size 14x51 2 to 32 FNX 32 TPN / FP SK96903 * 1 FNX 32 TPN / FP SK96903 * 1
Fr 1
63 HF Size 14x51 2 to 63 FNX 63 TPN / FP SK96904 * 1 FNX 63 TPN / FP SK96904 * 1
Fr 2 100 HN Size 000 63 to 100 FNX 100 TPN / FP SK96906 * 1 FNX 100 TPN / FP SK96906 * 1
125 HN Size 000/00 63 to 125 FNX 125 TPN SK95806 * 1 FNX 125 FP SK95814 * 1
Fr 3
160 HN Size 000/00 63 to 160 FNX 160 TPN SK95807 * 1 FNX 160 FP SK95815 * 1
200 HN Size 0 80 to 200 FNX 200 TPN SK95808 * 1 FNX 200 FP SK95816 * 1
Fr 4
250 HN Size 1 125 to 250 FNX 250 TPN SK95809 * 1 FNX 250 FP SK95817 * 1
315 HN Size 1 125 to 315 FNX 315 TPN SK95810 * 1 FNX 315 FP SK95818 * 1
Fr 5
400 HN Size 2 200 to 400 FNX 400 TPN SK95811 * 1 FNX 400 FP SK95819 * 1
630 HN Size 3 315 to 630 FNX 630 TPN SK95812 * 1 FNX 630 FP SK95820 * 1
Fr 6
800 HN Size 3 315 to 800 FNX 800 TPN SK95813 * 1 FNX 800 FP SK95821 * 1
* Available on request
Notes : 1) For 690V AC application, please contact nearest branch office.
2) The prices for S-D-F range are without HRC fuses
l Type: Cylindrical (2A to 63A), DIN (63A to 800A) & Bolted (2A to 630A)
l High breaking capacity: 100kA for type HN and 80kA for type HF/HG/HQ
Fuse holders & Fuse bases suitable for Cylindrical / DIN fuse-links
Rated Suitable fuse-link M.R.P. Std.
Current Type Description Cat. No. (`) Pkg.
Type Range (A)
(A) Per Unit (Nos.)
32 HCO 32 Fuse holder HF 2-32 SK91314 275 10
63 HC 63 Fuse holder HF 2-63 SK91043 310 10
160 HB 160 Fuse base HN-Size 000 & 00 63-160 SK90405 420 12
250 HB 250 Fuse base HN-Size 0 & 1 80-250 SK90406 920 3
800 HB 800 Fuse base HN-Size 2 & 3 200-800 SK91051 1795 3
HB HCO
Castell Type DIN Rail Auxiliary Handle Handle Earthing Switched Auxiliary Castell Type
Lock Assembly Contact Kit Assembly Assembly Link Neutral Kit Contact Kit Lock
M.R.P. Std. M.R.P. Std.
Description Type Cat. No. (`) Pkg. Description Type Cat. No. (`) Pkg.
Per Unit (Nos.) Per Unit (Nos.)
Rating (A)
16 20 25 32 40 50 63 80 100 125 160 200 250 320 400
Icu (kA)
10 DY125U
18 DU100D DU125D
25 DU250C
30 DU100H DU125H
36 DU250
50 DU400N
DY125U MCCBs
Auxiliary/Trip Alarm Contact Shunt Release Spreader Terminals Direct ROM Extended ROM
Internal External
Note: 2 Pole in 3 pole frame size DIN rail kit available as an accessory. Please refer DU100H/DU125H accessories table.
Auxiliary Contact ATAC Shunt Release UV Release Spreader Terminals Direct ROM Extended ROM
Internal External
Description
Cat. No. M.R.P. (`) Std. Pkg. Description M.R.P. Std.
Per Unit (Nos.) Cat. No. (`) Pkg.
Auxiliary Contact Per Unit (Nos.)
1 C/O - Right CM97886OOOO 1000 1 Spreader Terminals
2 C/O - Right CM97887OOOO 1775 1 DU100H - 2 Pole CM97785OOO2 260 Set of 4
Trip Alarm Contact DU125H - 2 Pole CM91199OOLO 335 Set of 4
1 C/O - Right CM97888OOOO 1000 1 DU100D/DU100H - 3 Pole CM97785OOOO 395 Set of 6
2 C/O - Right CM97889OOOO 1775 1 DU125D/DU125H - 3 Pole CM90687OOLO 515 Set of 6
Auxiliary + Trip Alarm Contact DU100D/DU100H - 4 Pole CM97921OOOO 625 Set of 8
1 C/O + 1C/O - Right CM97890OOOO 1705 1 DU125D/DU125H - 4 Pole CM90688OOLO 745 Set of 8
Shunt Release Rotary Handle
24V DC - Left CM91402O4OO 1825 1 DU100D/DU125D/ Direct ROM CM97895OOOO 1280 1
110V AC - Left CM97883OAOO 1825 1 DU100H/DU125H Extended ROM CM97896OOOO 1650 1
240/415V AC - Left CM97883OMOO 1980 1 DIN rail kit
Under Voltage Release DU100D/DU125D/DU100H/DU125H CM90944OOOO 145 1
240V AC - Left CM97892BOOO 3295 1 SS Enclosure
Size I Enclosure CM90996OOOO 2285 1
Note: Phase Barriers are supplied along with all MCCBs
Auxiliary Contact ATAC Shunt Release UV Release Spreader Terminals Direct ROM Extended ROM
Internal External
Description
Cat. No. M.R.P. (`) Std. Pkg. Description M.R.P. Std.
Per Unit (Nos.) Cat. No. (`) Pkg.
Auxiliary Contact Per Unit (Nos.)
Auxiliary Contact TAC Shunt Release UV Release Spreader Terminals Direct ROM Extended ROM
Internal External
Description M.R.P. (`) Std. Pkg.
Cat. No. Description M.R.P. Std.
Per Unit (Nos.) Cat. No. (`) Pkg.
Auxiliary Contact Per Unit (Nos.)
1 C/O CM99801OOOO 1160 1 Spreader Terminals
2 C/O CM99802OOOO 2250 1 2 Pole CM90964OOOO 2085 Set of 4
Trip Alarm Contact 3 Pole ST98065OOOO 3310 Set of 6
1 C/O - Right CM99803OOOO 1230 1 4 Pole ST98066OOOO 4745 Set of 8
Auxiliary + Trip Alarm Contact Rotary Handle
1 C/O + 1C/O - Right CM99804OOOO 2255 1 Direct ROM CM99860OOOO 2120 1
Shunt Release Extended ROM CM99861OOOO 3485 1
110/240/415V AC, 220V DC CM99805OOOO 2925@ 1 Note: Phase Barriers are supplied along with all MCCBs
24V DC CM98976O4OO 2740@ 1 All internal accessories & ROMs are common for 2P MCCBs
Under Voltage Release @ - ‘NO’ of control contactor to be connected in series for DC control supply
M.R.P. Std.
Description Cat. No. (`) Pkg.
Per Unit (Nos.)
Size I Enclosure for DU100H/DU125H/
CM90996OOOO 2285 1
DU100D/DU125D/DN0/DY125U
Size II Enclosure for
CM91003OOOO 5250 1
DU250C/DU250/DN1
Rating (A)
16 20 25 32 40 50 63 80 100 125 160 200 250 320 400 500 630
Icu=Ics (kA)*
25 DN0-100C DN1-C
36 DN0-100D/125D DN3B
36/50 DZ1
Note:
Breaking Capacity : C = 25kA, D = 36kA, N = 50kA, S = 70kA
@ Motorised version available for DN2 and DN3 frames (please refer page No. 46)
* DN0-100D/125D : Ics= 50% Icu
** For DN0, DN1, DN3B-Short Circuit Setting: 9In
For DN1-250N (50kA) please contact nearest branch office
*** From 16A to 50A, Fixed Magnetic setting (375A)
* Price on request Note: Add suffix as "OOOO"to all DZ1 cat. nos.
General Information
l Use of phase barriers is mandatory. These are supplied along with MCCBs
l It is recommended to use spreader terminals for enhancing termination capacity
l Spreader terminals are available as accessories, unless otherwise specified against cat. nos.
Special Applications
l dsine/DU/DY MCCBs with TM release can be used for DC application (2P/3P/4P)
l dsine/DU MCCBs can be used for Capacitor back-up protection
l For Motor back-up protection, use ‘M’ series of MCCBs such as DN0-M, DZ1-N, DN1-M, DN2-M, DN3-M
l For isolator applications, use SD version (without protection release)
l Adjustable overload setting from 0.4 to 1.0 x In l Adjustable overload setting from 0.25 to 1.0 x In
l Adjustable short-circuit setting from 1.5 to 8 x Ir l Adjustable short-circuit setting from 1.5 to 10 x Ir
l Inbuilt ground fault protection from 20%-50% of In l Inbuilt ground fault protection from 20%-70% of In
l Adjustable neutral overload protection from 50% to 150% of Ir l Adjustable neutral overload protection from 50%
l Panel mounted display for current metering & trip record l Individual fault indication LEDs
l Manual, Rotary and Motorised versions available@ l Transparent sealable release cover
0.5
1.0
1.5
0.3
l Suitable for Isolation MTX 3.0
l Adjustable Over Load from 0.4 - 1.0 x In
l Adjustable Short Circuit from 1.5 - 8 x Ir with selectable time delay
l Instantaneous protection with fine settings
l Inbuilt ground fault protection from 10% - 50% of In
l Adjustable neutral overload protection available : 50% to 150% of Ir
l Advanced Current, Voltage, Frequency & Power based protections
l Other Protections like Maximum Demand, Phase Sequence, THD etc.
l Comprehensive Current, Power, Energy, PF, MD, THD metering
l Provision of Thermal Memory : ON/OFF
l Variable trip class at 1.5 Ir,6 Ir & 7.2 Ir
l Front LED indication of Over Load, short circuit & earth fault
l Panel mounted display available for advanced protections & metering
l Communication capable release
l Manual, Rotary or Motorised versions available @
l For 3 phase 4 wire system, External neutral CTs available for 3P MCCBs
l Wide Range of snap fit Internal and External Accessories
Breaking 3 Pole 4 Pole
Release Capacity Icu Std.
Type Range M.R.P. M.R.P. Pkg.
(A) at 415V AC, Cat. No. (`) Cat. No. (`) (Nos.)
50Hz. (kA) Per Unit Per Unit
16 - 40 CM92063OOOOBG CM92155OOOOBG 1
25 - 63 CM92071OOOOBG CM92154OOOOBG 1
DN2-250D 40 - 100 CM92051OOOOBG CM92153OOOOBG 1
63 - 160 36 CM92074OOOOBG CM92152OOOOBG 1
100 - 250 CM92054OOOOBG CM92151OOOOBG 1
DN3-400D 160 - 400 CM93001OOOOBG CM93003OOOOBG 1
DN3-630D 250 - 630 CM93005OOOOBG CM93007OOOOBG 1
16 - 40 CM92064OOOOBG CM92160OOOOBG 1
25 - 63 CM92072OOOOBG CM92159OOOOBG 1
DN2-250N 40 - 100 CM92052OOOOBG CM92158OOOOBG 1
63 - 160 CM92075OOOOBG CM92157OOOOBG 1
100 - 250 CM92055OOOOBG CM92156OOOOBG 1
50
DN3-400N 160 - 400 CM93002OOOOBG CM93004OOOOBG 1
DN3-630N 250 - 630 CM93006OOOOBG CM93008OOOOBG 1
320 - 800 CM96021OOOOBG CM96111OOOOBG 1
DN4-1250N 400 - 1000 CM96022OOOOBG CM96112OOOOBG 1
500 - 1250 CM96023OOOOBG CM96113OOOOBG 1
16 - 40 CM92065OOOOBG CM92165OOOOBG 1
25 - 63 CM92073OOOOBG CM92164OOOOBG 1
DN2-250S 40 - 100 CM92059OOOOBG CM92163OOOOBG 1
63 - 160 CM92076OOOOBG CM92162OOOOBG 1
100 - 250 CM92056OOOOBG CM92161OOOOBG 1
70
DN3-400S 160 - 400 CM94053OOOOBG CM94153OOOOBG 1
DN3-630S 250 - 630 CM94079OOOOBG CM94179OOOOBG 1
320 - 800 CM96025OOOOBG CM96115OOOOBG 1
DN4-1250S 400 - 1000 CM96026OOOOBG CM96116OOOOBG 1
500 - 1250 CM96027OOOOBG CM96117OOOOBG 1
Note: Please contact nearest branch office for fuseless type 2 co-ordination selection chart
For lower HP motors, Please select MPCB. Details are given on page no. 18
Add suffix as "OOOO" to all DZ1 cat. nos.
Cost Effective
dsine-M range
3 Pole 4 Pole
Current Std. CB-3 CB-4
Type Rating M.R.P. M.R.P. Pkg.
(A) Cat. No. (`) Cat. No. (`) (Nos.)
Per Unit Per Unit
32 CM90716OOEO 6280 CM90717OOEO 8520 1
63 CM90716OOHO 6280 CM90717OOHO 8520 1
DN0-160SD 100 CM90716OOKO 7500 CM90717OOKO 9910 1
MCC
125 CM90716OOLO 8290 CM90717OOLO 11040 1
160 CM90716OOMO 8970 CM90717OOMO 11760 1 MCCB-6 as Isolator
Total Set
Frame Accessories Remarks
M.R.P. (`)
Add MRPs of Similar 2 MCCBs of DN2 of
DN2 103355 desired no. of Poles, Breaking Cap. &
2 Nos : SEOMs with Aux + Trip Alarm Contact Release to arrive at ASTS Solution.
+
DN3-400 1 No. : MIL 122650
Add MRPs of Similar 2 MCCBs of DN3 of
+ desired no. of Poles, Breaking Cap. &
Release to arrive at ASTS Solution.
1 No. : AuXC2000
DN3-630 123420
Note: Picture shown is for representation purpose only, MCCB + EOM + ATAC combination, MIL kit & AuXC-2000 to be purchased separately & assembled at site.
DN0, DU100D & DU100H MCCBs are suitable as outgoing devices up to 100 A
DN1-250N, DU250 & DU250C MCCBs are suitable as outgoing devices up to 250 A
SMDB M.R.P.
Description Cat. No. (`)
Type
Per Unit
Note:
- Ammeter, voltmeter, selector switch and indicating lights have to be ordered separately.
- Mounting base to be used without bottom cabling box.
- 12
CM91120OOHO 17380 CM91121OOHO 17380
- 16
2 10
CM91120OOHO 17380 CM91121OOHO 17380
2 14
S : 65kA
H : 80kA
UW1-08 UW1-10 UW1-12 UW1-16 UW1-20 UW1-25
N : 50kA
Frame-2
S : 65kA
H : 80kA
UW2-08 UW2-10 UW2-12 UW2-16 UW2-20 UW2-25 UW2-32 UW2-40
H : 80kA
Frame-3
V : 100kA
UW3-08 UW3-10 UW3-12 UW3-16 UW3-20 UW3-25 UW3-32 UW3-40 UW3-50 UW3-63
Note: 400A & 630A ACBs are also available on request. # Please contact the nearest branch office for more details of 1000V AC ACBs
(5)
For system requiring 690V metering, kindly order separate 4 Pole 50% N (in Fr-III only) H
Power Metering module with MTX 3.5 (refer page 58) 4 Pole 200% N (upto 2500A) D
# Please contact the nearest branch office for more details of 1000V AC ACBs
3 Pole ACBs upto 690V AC with UW-MTX1G (LSING - BCD Switches) [8536]
* Available on request
$ Chapter ID [8538]
* Available on request
Frame-2 4000A S/H (Vertical) CL60420OOOO Frame-2 400-2500A N/S (Vertical / Horizontal) CL60122OOOO
Frame-2 4000A S/H (Horizontal) CL60316OOOO Frame-2 400-3200A H, 3200A N/S (Vertical / Horizontal) CL60977OOOO *
*
Frame-3 400-4000A H/V (Vertical) # CL60128OOOO Frame-2 4000A S/H (Vertical) CL60417OOOO
Frame-3 400-4000A H/V (Horizontal-Long) CL60073OOOO Frame-3 400-4000A H/V (Vertical)# CL60418OOOO
Frame-3 5000A H/V (Horizontal-Long) CL60966OOOO Frame-3 5000A H/V (Vertical)# CL60347OOOO
Frame-3 5000A H/V (Vertical)# CL60067OOOO Frame-3 400-5000A H/V (Horizontal-Long) CL60373OOOO
Frame-3 6300A H/V (Vertical) # CL60965OOOO # : Please consider 4 terminal adaptors per phase.
# : Please consider 4 terminal adaptors per phase.
3P 4P
Breaking
Current Capacity Fix Draw-out Fix Draw-out
Rating Frame
@ M.R.P. M.R.P. M.R.P. M.R.P.
800V AC Cat. No. (`) Cat. No. (`) Cat. No. (`) Cat. No. (`)
Per Unit Per Unit Per Unit Per Unit
800A UW108NXF0180ZM UW108NXD0180ZM UW108NFF0180ZM UW108NFD0180ZM
1000A UW110NXF0180ZM UW110NXD0180ZM UW110NFF0180ZM UW110NFD0180ZM
1250A 1 50kA UW112NXF0180ZM UW112NXD0180ZM UW112NFF0180ZM UW112NFD0180ZM
* * * *
1600A UW116NXF0180ZM UW116NXD0180ZM UW116NFF0180ZM UW116NFD0180ZM
2000A UW120NXF0180ZM UW120NXD0180ZM UW120NFF0180ZM UW120NFD0180ZM
2000A UW220NXF0180ZM UW220NXD0180ZM UW220NFF0180ZM UW220NFD0180ZM
2500A UW225NXF0180ZM UW225NXD0180ZM UW225NFF0180ZM UW225NFD0180ZM
2 50kA * * * *
3200A UW232NXF0180ZM UW232NXD0180ZM UW232NFF0180ZM UW232NFD0180ZM
4000A - UW240NXD0180ZM - UW240NFD0180ZM
3200A UW332NXF0180ZM UW332NXD0180ZM UW332NFF0180ZM UW332NFD0180ZM
4000A 3 50kA UW340NXF0180ZM * UW340NXD0180ZM * UW340NFF0180ZM * UW340NFD0180ZM *
5000A UW350NXF0180ZM UW350NXD0180ZM UW350NFF0180ZM UW350NFD0180ZM
3200A UW332SXF0180ZM UW332SXD0180ZM UW332SFF0180ZM UW332SFD0180ZM
4000A 3 65kA UW340SXF0180ZM * UW340SXD0180ZM * UW340SFF0180ZM * UW340SFD0180ZM *
5000A UW350SXF0180ZM UW350SXD0180ZM UW350SFF0180ZM UW350SFD0180ZM
Note: 1. Above mentioned Cat. No. of ACBs are without Terminal Adaptors. Please consider Terminal Adaptors from below table.
2. Phase-Barriers are mandatory to be used with 800V AC ACBs:
(a) For Draw-out ACBs, Phase-Barriers are provided as standard supply along with ACBs
(b) For Fix ACBs, kindly consider Phase-Barriers from below table
Mechanical Interlock using Bowden Cable (2 meters length) Matrix Smart Card Module CL90705OOOO
Note: Common from 400A to 6300A and can be interlocked between EL Module CL90720OOOO
Fixed / Draw-out / Mixed version
REF Module CL90721OOOO
* Available on request Simulation Kit CL90724OOOO
For Energy Management Communication Software Please contact the nearest branch office
For retrofitting of any ACB to Omega ACB please contact the nearest branch office
Please contact the nearest branch office for Details & product Selection
C-POWER HE Range
630A 800A 1000A 1250A 1600A 2000A 2500A 3200A 4000A 5000A 6300A
CN-CS : E / G 50kA 50kA 50kA 50kA 50kA 50kA
Frame-1
Frame-1 Frame-2
For technical & dimension details please refer product catalogue. 400A ACB also available on request.
Note : Add a Suffix "OOOO" for all the above mentioned cat. nos.
C-POWER S1 3 & 4 Pole Fixed ACBs
Microprocessor Based SR18G Thermal-Magnetic DN1
Breaking
Capacity 3 Pole 4 Pole 3 Pole 4 Pole
Rating Version
Icu=Ics=Icw M.R.P. M.R.P. M.R.P. M.R.P.
(1 sec) Cat. No. (`) Cat. No. (`) Cat. No. (`) Cat. No. (`)
Per Unit Per Unit Per Unit Per Unit
MF SL95561 116600 SL95581 148550 SL95481 111100 SL95501 143050
630A 50kA
EF SL95571 163100 SL95591 195050 SL95491 157600 SL95511 189550
MF SL95562 116600 SL95582 148550 SL95482 111100 SL95502 143050
800A 50kA
EF SL95572 163100 SL95592 195050 SL95492 157600 SL95512 189550
MF SL95563 127340 SL95583 160610 SL95483 121840 SL95503 155110
1000A 50kA
EF SL95573 173840 SL95593 207110 SL95493 168340 SL95513 201610
MF SL95564 146620 SL95584 183290 SL95484 141120 SL95504 177790
1250A 50kA
EF SL95574 193120 SL95594 229790 SL95494 187620 SL95514 224290
MF SL95565 162650 SL95585 209080 SL95485 157150 SL95505 203580
1600A 50kA
EF SL95575 209150 SL95595 255580 SL95495 203650 SL95515 250080
Note : Add a Suffix "OOOO" for all the above mentioned cat. nos.
M.R.P. changes for product customization w.r.t. SR18G ACB M.R.P. M.R.P. (`) Per Unit
Bus - Coupler (w/o protection) Reduce 14200
Microprocessor based SR18G+D (LSING + Current Metering) Add 13000
Microprocessor based SR18Gi+D (LSING + Current metering + ZSI) Add 14500
C-POWER S1 Draw-Out ACBs will have inbuilt - 2NO+2NC Aux contact for MDO & 6NO+6NC Aux contact for EDO breakers, Safety shutter assembly,
Racking handle, Door sealing frame, Push-button cover & Rating error preventor.
C-POWER S1 Fixed ACBs will have inbuilt - 2NO+2NC Aux contact for MF & 6NO+6NC Aux contact for EF breakers, Door sealing frame & Push-button cover.
Electrical version includes 240V AC Shunt trip coil, Closing coil and Motor for electrical charging.
Note: 1 NO Aux contact in manual version & 2NO+2NC in electrical version breakers will be pre-wired with accessories mounted in breaker.
In electrically operated breaker with DN1 release, either earth fault or undervoltage protection can be used.
Note: For higher breaking capacities & 690V AC application please contact the nearest branch office
Add a Suffix "OOOO" for all the above mentioned cat. nos.
C-POWER Draw-Out ACBs will have inbuilt - 6NO+6NC Aux contact, Safety shutter assembly, Racking handle, Door sealing frame, Push-button cover & Rating
Error preventor. Option of horizontal & vertical termination upto 4000A also available. Operation counter for 4000A & above.
EDO version includes 240V AC Shunt trip coil, Closing coil and Motor for electrical charging.
C-POWER Fixed ACBs will have inbuilt - 6NO+6NC Aux contact, Door sealing frame & Push-button cover. Operation counter for 4000A & above.
Note: 1 NO Aux contact in manual version & 2NO+2NC in electrical version breakers will be pre-wired with accessories mounted in breaker.
In electrically operated breaker with DN1 release, either earth fault or undervoltage protection can be used.
Note: Electrical Fixed type breakers are available on request.
# Available on "Made to order" basis. * Available on request
Lockable Trip Push Button kit (3 I/C & 2 B/C) SL91936OOOO 21780 Type EA1 : 240V AC SL92718OBOO 3410
Locking of ACB in Isolated position (LIP) [8301] Type EA1 : 415V AC SL92718ODOO 3410
Locking of ACB in Any position (LAP) [8301] Earth Fault Release ( for DN1) [8538]
Type B SL93147OOOB 4660 Type EF2 (30%, 40%, 50% In) SL91341OOOO 4350
Type BB SL93149OOOB 6010 Microswitch for Voltmetric Releases (2) each SL92703OOOO 2700
Other Accessories [8538] Service Position Microswitch - Right (2) SL93142OOOO 1830
Door Interlock SL93150OOOO 3200 Service Position Microswitch - Left (2) SL93143OOOO 1830
Mechanical Operation Counter* XM80837OOOO 3160 Test or Isolated Position Microswitch - Right (2) SL93144OOOO 1830
Mounting Kit for Front Mounted Counter SL95882OOOO 1120 Test or Isolated Position Microswitch - Left (2) SL93145OOOO 1830
* For mounting the Operation counter, mounting kit “SL95882OOOO” needs to be Note :
ordered separately. Operation Counter inbuilt for rating 4000A to 6300A. a. The Numerical in brackets, against various accessories indicate the SICs
required for wiring purpose in Draw-Out breakers
b. Shunt release requires one set of auxiliary contacts
c. Maximum 24 SICs can be fitted on an ACB. In Electrical ACBs 5 SICs are
prewired for control circuit purpose
M.R.P. Std.
Description Cat. No. (`) Pkg.
Per Unit (Nos.)
CTs for SR18G / SR18G+D / SR18Gi+D [8504]
400 S1 Fix & Draw-out SL01523OOOO 6430 1
630 S1 Fix & Draw-out ST37495OOOO 6430 1
800 C/H/S1 Fix & Draw-out SL01857OOOO 6430 1
1000 C/H/S1 Fix & Draw-out SL01858OOOO 6430 1
1250 C/H/S1 Fix & Draw-out SL90571OOOO 7780 1
1600 C/H/S1 Fix & Draw-out SL90572OOOO 7780 1
2000 C/H Fix & Draw-out SL90565OOOO 8630 1
2000 S1 Draw-out SL93210OOOO 8630 1
2500 C/H Fix & Draw-out
CT SL90566OOOO 8630 1
2500 S1 Draw-out
3200 H2/H1 Draw-out SL01740OOOO 9920 1
4000 H2/H Draw-out SL01739OOOO 11900 1
For External Neutral C.T.s please use the above Cat. No.
Operating losses 0.45 W/kVAr 0.45 W/kVAr 0.5 W/kVAr 0.35 W/kVAr 0.35 W/kVAr 0.45 W/kVAr 0.5 W/kVAr 0.45 W/kVAr 0.35 W/kVAr
Peak Inrush current
withstand capability 200 x In 200 x In 250 x In 300 x In 250 x In 350 x In 300 x In 500 x In 500 x In
Number of switching
operations per year 5000 5000 7500 8000 8000 15000 10000 18000 20000
Max. Temperature 55 C
O
55 C O
55 C
O
55 C
O
55 CO
65 C
O
55 C
O
65 C
O
70OC
Operating life 100000 hrs. 100000 hrs. 130000 hrs. 150000 hrs. 150000 hrs. 200000 hrs. 200000 hrs. 300000 hrs. 300000 hrs.
479
Capacitors 5 to 15 440 V
20 to 50 469
M.R.P. Box Series:
kVAr Voltage 5.5 to 15 503
Type (`) LTBCH
Rating (V) 480 V
per kVAr 20 to 27.7 493
3 to 5 606 6.6 to 15 513
7.5 to 15 440 495 525 V
20 to 33.1 501
20 & 25 460
Cylindrical Series: LTCCN 7.5 to 15
480
542 Standard Duty Prime Capacitors
20 to 30 483
kVAr Voltage M.R.P. (`)
7.5 to 15 552 Type
Rating (V) per kVAr
525
20 to 33.1 492
Cylindrical Series: LTCCV 5 to 25 440 V 300
3 to 5 613 5 to 15 808
440 V
7.5 to 15 440 V 501 20 to 50 782
1.3 to 5 656
6.6 to 15 525 V 558
20 to 33.3 507
L T C 3 2 Catalogue Number
kVAr ratings
Capacitor
Series 440 V 480 V 525 V
LTCCF 1, 2, 3, 4, 5, 6 1.2, 2.2, 3.3, 4.4, 5.5 1.3, 2.6, 3.9, 5.3, 6.6
LTBCF 1, 2, 3, 4, 5, 6 - -
LTCCD/LTBCD 7.5, 8.33, 10, 12.5, 15, 20, 25, 30* 11.1, 13.8, 16.6, 22.1, 27.7 13.2, 16.6, 20, 26.5, 30, 33.1
LTCCH 1, 2, 3, 4, 5, 7.5, 10, 12.5, 15, 20, 25, 30 5.5, 11.1, 13.8, 16.6, 22.1, 27.7 6.6, 13.2, 16.6, 20, 26.5, 30, 33.1
LTBCH 1, 2, 3, 4, 5, 7.5, 8.33, 10, 12.5, 15, 20, 25, 30, 50 5.5, 11.1, 15, 20, 25, 27.7 6.6, 13.2, 15, 20, 25, 30, 33.1
LTCCN 3, 4, 5, 7.5, 8.33, 10, 12.5, 15, 20, 25 7.5, 12.5, 15, 20, 25, 30 7.5, 12.5, 15, 20, 25, 30, 33.1
LTCCR 3, 4, 5, 7.5, 8.33, 10, 12.5, 15, 20, 25 1.2, 2.2, 3.3, 4.4, 5.5, 11.1, 15, 20, 25, 27.7 1.3, 2.6, 3.9, 5, 6.6, 13.2, 15, 20, 25, 30, 33.3
LTBCP 5, 7.5, 10, 12.5, 15, 20, 25, 50 5.5, 11.1, 13.8, 16.6, 22.1, 27.7, 55.3 6.6, 13.2, 16.6, 20, 26.5, 30, 33.1, 66.2
LTCCU 5, 7.5, 8.33, 10, 12.5, 15, 20, 25 7.5, 10, 12.5, 15, 20 7.5, 10, 12.5, 15, 20
LTBCU 5, 7.5, 8.33, 10, 12.5, 15, 20, 25, 30, 50 7.5, 10, 12.5, 15, 20, 25, 30 7.5, 12.5, 15, 20, 25, 30, 33.1
kVAr 7% Copper Reactor 7% Aluminium Reactor 14% Copper Reactor 14% Aluminium Reactor
Rating M.R.P. (`) M.R.P. (`) M.R.P. (`) M.R.P. (`)
Cat. No. Cat. No. Cat. No. Cat. No.
Per Unit Per Unit Per Unit Per Unit
1 LTFR0701B2 9185 LTAL0701B2 6665 LTFR1401B2 17855 LTAL1401B2 11000
Last Two Contacts can be programmed for Capacitor Switching / Alarm Function / Fan Control
500
400
300
200 Base load
100
0
10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210
Time in sec.
For For ‘Thyristor + Contactor’ based APFC Panels for performance and economy
Fluctuating load Base load
Features:
• Modular and expandable steps
• CT secondary - 1 A / 5 A Site selectable
• Suitable for LT as well as HT side sensing 2 & 4 Quadrant Operation for sites with / without Solar Plants
• Communicable on Modbus through RS485 Plug-in Module etaCON M Optional Plug-in Modules
5 Step APFC Controller (96 x96) 415V / ETACONM005R 15600 2 Steps Plug-in Module 2 Relays NO ETACONEXP2R 2400
1A/5A
8 Step APFC Controller (144 x144) 110 V ETACONM008R 19400 3 Steps Plug-in Module 3 Relays NO ETACONEXP3R 3500
RS485 Plug-in Module RS485 Plug-in Module ETACONRS485 12000
60 AHF060331D2 AHF060341D2
75 AHF075331D2 AHF075341D2
* Standard CAT. No. Configuration
100 AHF100331D2 AHF100341D2
Contact your nearest sales office for customised solutions:
150 AHF150331D2 On AHF150341D2 On
Customisable Options Available:
200 AHF200331D2 Request AHF200341D2 Request
IP Class : IP20/IP40/IP42
300 AHF300331D2 AHF300341D2
Cable Entry : Bottom / Top / Additional Cable Alley
400 AHF400331D2
Communication : MODBUS RS485 Protocol Available
600 AHF600331D2 -
800 AHF800331D2
Reliable
• Worry free PF management with 4 quadrant PF controller
• Certified for better thermal management as per IEC 61921
• Design verified assemblies of both constructional & permanence
requirements
• Separate section for detuned reactors, capacitors & switchgear
ensures longer life of components & less worry on maintenance
Safety
• Form 3B separation (compartmentalized design for switchgear)
• Bus bars with more clearance than prescribed in standards
• A minimum of IP2X degree of protection even when the doors /
covers in open condition
• Earthing of each and every door and structural members
• Zero stray voltage on doors & covers ensures both operator &
equipment safety
Note : Above mentioned steps are typical recommendations, suitable for most of the industries. For accurate compensation, step size selection may have to be decided
after studying load profile of that industry.
3 Phase Over Current + Earth Fault Relay Single Pole Over Current or
C.T. Rating 1A or 5A, Field Selectable Earth Fault Relay
C.T. Rating 1A or 5A, Not Field Selectable
• IDMT & Definite time characteristics • IDMT and Definite time characteristics
• Last 30 trip data recording with
date and time
• Password Protection
Earth Fault
MC12 MC12
Aux. M.R.P.
Supply Output Device • System Voltage is site selectable -
Model Code Cat. No. (`)
(V) Contacts
Per Unit 110V / 415V AC
24 - 240V 2 NO + 2 NC 51, 51N, MC61ANX2200
MC61AnX 23000
AC/ DC 4 NO 50, 50N MC61ANX4000
MV12
Single Phase Under Voltage or Over Voltage Relay
• System Voltage is site selectable - 110 / 240 / 415V AC
Description Output contacts Reset Contacts Reset Flag Coil Voltage Cat. No. M.R.P. (`) Per Unit
24VDC L1H32DC024X
Description Output contacts Reset Contacts Reset Flag Coil Voltage Cat. No. M.R.P. (`) Per Unit
24VDC A1H40DC024X
M.R.P. M.R.P.
Description Cat. No. (`) Description Cat. No. (`)
Per Unit Per Unit
1P LCD Meter 5-30A WM101BC5DL0 1699 3Ph 4 W kWh CT op base mtg 240V, /5A, Acc 0.5s WR301BC3C00 5380
1P LCD Meter 5-30A with BOX WM101BC5DL0BOX 2274 3Ph 4 W kWh Dir base mtg 240V 5- 30 A Acc 1 WR301BC4D20 4507
1P LCD Meter 5-30A with OPTICAL PORT WM101BC5DDH 2333 3Ph 4 W kWh Dir base mtg 240V 10- 40 A Acc 1 WR301BC6D20 4640
1P LCD Meter 5-30A with Optical port + BOX WM101BC5DDHBOX 2907 3Ph 4 W kWh Dir base mtg 240V 10- 60 A Acc 1 WR301BC7D10 5877
1P LCD Meter 10-60A WM101BC7DL0 2010 3Ph 4 W kWh Dir base mtg 240V 20- 100 A Acc 1 WR301BC8D10 8522
1P LCD Meter 10-60A with BOX WM101BC7DL0BOX 2535
1P LCD Meter 10-60A with Optical Port WM101BC7DDH 2570
1P LCD Meter 10-60A with Optical Port + BOX WM101BC7DDHBOX 2956 Trivector Meter Class 0.5s
Model ER300P Class 0.5s (Base Mounting)
• Inform CT/PT ratio while ordering
• DLMS (IS 15959) Protocol meters is
available on request
Trivector Meter Class 1
M.R.P.
whole current meter Description Cat. No. (`)
Per Unit
Model ER300P Class 1 (Base Mounting)
3Ph, 4W TVM 110V ( L-L) 1 A Class 0.5s BM WR300BB1200 25754
3Ph, 4W TVM 110V ( L-L) 5 A Class 0.5s BM WR300BB5200 25754
M.R.P.
Description Cat. No. (`) 3Ph, 4W TVM 240V ( L-N) 5 A Class 0.5s BM WR300BC5200 23735
Per Unit 3Ph, 4W TVM 110V ( L-L) 1 A Class 0.5s BM RS 485 Modbus WR300BB12RS 30905
3Ph, 4W TVM 240 V 10 - 60A BM WR300BC7300 8017 3Ph, 4W TVM 110V ( L-L) 5 A Class 0.5s BM RS 485 Modbus # WR300BB52RS 30905
3Ph, 4W TVM 240 V 10 - 60A BM RS 485 Modbus* WR300BC73RS485 11436 3Ph, 4W TVM 240V ( L-N) 5 A Cl 0.5s BM RS 485 Modbus WR300BC52RS 28482
3Ph, 4W TVM 240 V 10 - 60A BM with WR300BC73BOXH # - available on request only
Hinge type Box 9930
Meter Reading Instrument Net Meters for solar roof top application & solar generation plant
[8471]
ORION (40-200A)$
M.R.P.
Description Cat. No. (`)
Per Unit
Meter Reading Instrument - (16.5 MB) 990MRIXX000 133146
Meter Optical port to USB cable 990PCXXUSB 1594
Combine CT Meter - Thread Through Meter (Meter + CT+ Modem)
$ For more details please contact nearest branch
Energy display
in kWh in its
lifetime#
M.R.P.
Description Cat. No. (`)
Per Unit
3Ph LED Ammeter Cl 1 WL131010OOOO 1395 kWh LED meter Cl 1 WL400010OOOO 2680
3Ph LED Voltmeter Cl 1 WL132010OOOO 1395 kWh LED meter Cl 1 with RS485 WL400011OOOO 3160
LED Freq meter Cl 0.2 WL113040OOOO 925 kWh LED meter Cl 0.5 WL400020OOOO 3395
1Ph LED Ammeter Cl 0.5 WL111020OOOO 1245 kWh LED meter Cl 0.5 with RS485 WL400021OOOO 3870
1Ph LED Voltmeter Cl 0.5 WL112020OOOO 1245 kWh LCD meter Cl 1 WC400010OOOO 3025
3Ph LED Ammeter Cl 0.5 WL131020OOOO 1680 kWh LCD meter Cl 1 with RS485 WC400011OOOO 3510
3Ph LED Voltmeter Cl 0.5 WL132020OOOO 1680 kWh LCD meter Cl 0.5 WC400020OOOO 3750
VAF + PF Meters [9030] # For 415V LL and CT Primary value of 400 and below
VAF + PF meter with RS485, Cl 1 WL411011OOOO 2980 • Push to push mode for variable kWh consumption monitoring
VAF + PF meter, Cl 0.5 WL411020OOOO 2735 • Parameters: 1 Phase - Voltage, Current, kW, kWh
VAF + PF meter with RS485, Cl 0.5 WL411021OOOO 3310 3 Phase - Voltage, Current, kW, kWh + PF, kVA, kVAr, MD
Dualsource LED meter Cl1 WL404010OOOO 4380 MFM 4405 LED meter Cl 0.5S with RS485 WL440531OOOO 7865
WL404021OOOO
5205
6405
Multifunction Meters [9030]
Dualsource LCD meter Cl1 WC404010OOOO 4820 Features
Dualsource LCD meter Cl1 with RS485 WC404011OOOO 5890 • Accuracy Class 1.0, 0.5, 0.5S, 0.2, 0.2S
• Input voltage measurement range 50-520 VAC (P-P)
Dualsource LCD meter Cl0.5 WC404020OOOO 5660
• Aux supply 80-300 VAC/DC
Dualsource LCD meter Cl0.5 with RS485 WC404021OOOO 6795 • CT secondary site selectable 1A / 5A True and
Displacement
• Flush mounting 96 x 96 mm
PF available
• CT/PT site programmable
LCD offers better readability MFM 4410 LED meter Cl 1 with RS485 WL441011OOOO 9165
of parameters
MFM 4410 LED meter Cl 0.5 with RS485 WL441021OOOO 10880
M.R.P. MFM 4410 LED meter Cl 0.2 with RS485 WL441041OOOO 14315
Description Cat. No. (`)
Per Unit MFM 4410 LED meter Cl 0.2S with RS485 WL441051OOOO 18320
MFM 4400 LED meter Cl 1 WL440010OOOO 4220 MFM 4410 LCD meter Cl 1 WC441010OOOO 9425
MFM 4400 LED meter Cl 1 with RS485 WL440011OOOO 5215 MFM 4410 LCD meter Cl 1 with RS485 WC441011OOOO 10595
MFM 4400 LED meter Cl 0.5 with RS485 WL440021OOOO 6165 MFM 4410 LCD meter Cl 0.5 with RS485 WC441021OOOO 12360
MFM 4400 LED meter Cl 0.5S with RS485 WL440031OOOO 6230 MFM 4410 LCD meter Cl 0.5S with RS485 WC441031OOOO 13540
MFM 4400 LCD meter Cl 1 WC440010OOOO 4650 MFM 4410 LCD meter Cl 0.2 with RS485 WC441041OOOO 15890
MFM 4400 LCD meter Cl 1 with RS485 WC440011OOOO 5675 MFM 4410 LCD meter Cl 0.2S with RS485 WC441051OOOO 20005
MFM 4420 LCD meter Cl 1 with RS485 WC442011OOOO 14720 Constant Wh viewing in LCD
MFM even in auto scroll mode.
MFM 4420 LCD meter Cl 0.5 with RS485 WC442021OOOO 16485
LCD offers better readability
MFM 4420 LCD meter Cl 0.5S with RS485 WC442031OOOO 17655 of parameters
4430 Series MFM for IE MFM 5000 LED meter Cl 0.5 with Ethernet WL500022OOOO 38785
Parameters: 2 Relay outputs MFM 5000 LED meter Cl 0.5S with Ethernet WL500032OOOO 39850
for MD Alarm
• All parameters of Model 4420 series MFM 5000 LCD meter Cl 1 with RS485 WC500011OOOO 33800
• Bi-directional (Import-Export)
MFM 5000 LCD meter Cl 1 with Ethernet WC500012OOOO 38255
M.R.P. MFM 5000 LCD meter Cl 0.5 with RS485 WC500021OOOO 35385
Description Cat. No. (`)
Per Unit MFM 5000 LCD meter Cl 0.5S with RS485 WC500031OOOO 36455
MFM 4430 LED meter Cl 1 WL443010OOOO 16590 MFM 5000 LCD meter Cl 0.5 with Ethernet WC500022OOOO 39850
MFM 4430 LED meter Cl 1 with RS485 WL443011OOOO 17660 MFM 5000 LCD meter Cl 0.5S with Ethernet WC500032OOOO 40910
MFM 4430 LED meter Cl 0.5 with RS485 WL443021OOOO 19260 MFM 5000 LCD meter Cl 0.2 with RS485 WC500041OOOO 38575
MFM 4430 LED meter Cl 0.5S with RS485 WL443031OOOO 20330 MFM 5000 LCD meter Cl 0.2S with RS485 WC500051OOOO 42295
MFM 4430 LED meter Cl 0.2 with RS485 WL443041OOOO 22475 MFM 5000 LED meter Cl 1 RS485 2A/O WL500011OBOO 35380
MFM 4430 LED meter Cl 0.2S with RS485 WL443051OOOO 26220 MFM 5000 LED meter Cl 0.5 RS485 2D/I WL500021OOBO 36975
MFM 4430 LCD meter Cl 1 WC443010OOOO 17660 MFM 5000 LED meter Cl 0.5 RS485 4D/O WL500021OOOD 38040
MFM 4430 LCD meter Cl 1 with RS485 WC443011OOOO 18725 MFM 5000 LCD meter Cl 1 RS485 2A/O WC500011OBOO 36450
MFM 4430 LCD meter Cl 0.5 with RS485 WC443021OOOO 20330 MFM 5000 LCD meter Cl 0.5 RS485 2D/I WC500021OOBO 38040
MFM 4430 LCD meter Cl 0.5S with RS485 WC443031OOOO 21400 MFM 5000 LCD meter Cl 0.5 RS485 4D/O WC500021OOOD 39105
MFM 4430 LCD meter Cl 0.2 with RS485 WC443041OOOO 23540 MFM 5000 LCD meter Cl 1 + RS485, 1AO, 1DO WC500011OAOA 36685
MFM 4430 LCD meter Cl 0.2S with RS485 WC443051OOOO 27290
5000 series with Digital outputs are preconfigured for
I - THD% at 8% and True PF at 0.98.
4440 Series
Meter can be site selected for parameters and values - A THD,
Parameters: V THD, VA, W, under PF, under/over (VLL, A, F) with
• All parameters of 4410 series programmable trip time (1 to 180 sec) to protect the equipments
• Maximum Demand with Real Time Clock (RTC) from electrical abnormalities.
• Events (high-low) with time stamp
M.R.P. Data Log Interval
Description Cat. No. (`)
Per Unit Parameters 15 Min 30 Min 45 Min 60 Min
MFM 4440 LED meter Cl 1 with RS485 WL444011OOOO 14775 No. of Days
1 10230 20460 30690 40920
MFM 4440 LED meter Cl 0.5 with RS485 WL444021OOOO 16610
2 6820 13640 20460 27280
MFM 4440 LED meter Cl 0.2 with RS485 WL444041OOOO 20310
4 4092 8184 12276 16368
MFM 4440 LCD meter Cl 1 with RS485 WC444011OOOO 16005
9 2046 4092 6138 8184
MFM 4440 LCD meter Cl 0.5 with RS485 WC444021OOOO 17845 14 1364 2728 4092 5456
MFM 4440 LCD meter Cl 0.2 with RS485 WC444041OOOO 21540 29 682 1364 2046 2728
• Events (high-low) with time stamp MFM 5010 LED meter Cl 0.5S with RS485 WL501031OOOO 15880
• Individual Harmonics upto 31st. MFM 5010 LED meter Cl 0.2 with RS485 WL501041OOOO 18075
• Block/sliding window site selectable MDC 6000 LED meter Cl 0.5S with RS485 WL600031OOOO 30680
• Running demand, max demand, prediction demand in MDC 6000 LCD meter Cl 1 with RS485 WC600011OOOO 29065
single page window
MDC 6000 LCD meter Cl 0.5S with RS485 WC600031OOOO 31760
• Individual harmonics upto 31st
- OLD
- EB
- OLD
• Parameters: V, A, PF, W, VA, Wh - EB, DG
• Communication: Wired (Modbus RS485) or Wireless (LoRaWAN)
- DG - DG
kWh kWh
• Facility for connection or disconnection of electric supply based on the credit balance
SMPR 3P 1060RS SMPR 3P 1060RS in the meter through relay
• Server maintained at site itself
3Ph 4 Wire Principal Unit: kWh Class 1.0 Ib-10A, In-60A 3Ph 4 Wire Principal Unit: kWh Class 1.0 Ib-10A, In-60A
O O
3 X 240V, 50Hz Ref. Temp: 27 C 1600 impulses/kWh 3 X 240V, 50Hz Ref. Temp: 27 C 1600 impulses/kWh
• Optional
- In RS485 model upto 4DI for water and gas meter
- In LoRaWAN model upto 2DI for water and gas meters
• Wireless postpaid or prepaid metering solutions for large townships on SmartComm
EMS Platform available.
• With LoRaWAN technology, meters upto 1 km approx from LoRa Gateway can be
monitored without Line of sight.
• Prices available on request.
Connect large townships with wireless energy meters on IoT based SmartComm EMS
Network
Server
- OLD
- DG
Ethernet
OR
SMPR 3P 1060RS
3Ph 4 Wire Principal Unit: kWh Class 1.0 Ib-10A, In-60A
Switch
3 X 240V, 50Hz Ref. Temp: 27OC 1600 impulses/kWh
4G
Wireless
LoRa Meter SmartComm EMS
LoRa Gateway -
GPRS Public Static IP
SmartComm EMS
Simple and powerful energy monitoring software with multiple benefits that empowers the user to save money.
Features:
• Glimpse of entire energy consumption in the plant through • Provision to generate multiple report types
dashboard • Specific Energy Consumption (SEC) report
• Quick understanding of energy consumption of today compared • Access to features defined by user levels
to yesterday, this month consumption compared to last month as
• E&A meters preconfigured in the software
well as yoy energy comparison through dashboard.
• Monitor ON, OFF, Trip, Ready to close status of circuit breaker
• Easy navigation through the modules ,
through E&A s UNCO module with on premise solution
• Excel reports with charts
• Control Circuit breaker ON & OFF, provision for breaker On & Trip
• All parameters in the device can be monitored from the software counter, last 20 trips date & time stamp with on premise solution
• Multiple combination of devices and parameters for analysis • Email & SMS notification
Please scan the QR code and fill in the details on the webpage
(www.lntebg.com/ems) to schedule a demo of SmartComm EMS
• SmartComm EMS license ordering is based on number of nodes to get started on your Energy Management journey.
i.e meters / UNCO module to be connected in the system.
Please contact nearest branch office for optimal Energy Monitoring Solution and network architecture with SmartComm EMS software.
Features:
· Built-in RTC for Scheduling · Fire Mode
· Built-in EMC filter as default (C3) · Flow Compensation
· Built-in 4 PID (1 Main & 3 EPID) · Password Protection
· Multiple-Motor Control · Built-in RS485 Communication for HVAC
(1 main motor and 5 auxiliary motors) - BACnet, Modbus-RTU, Metasys N2
· Built-in Payback Counter · Lubrication Control
· Pump Clean Control · Dry Pump Detection
· V/F, Slip Compensation · Global Compliant- UL Plenum Rated, CE
• Complying to IEC 61800 - 3
Standard
High on compactness, • Reduced electrical noise and more
immune to external noise
Higher on functionality
• LTOP-DOP-52 : Easy to
mount on panel door
• Comes with 3 metre cable
• Easy to fix
• Allows quick installation for
side by side mounting
Internally mounted
PLC optional module Digital Points: 6 Nos (NPN/PNP))
Input M.R.P.
Description Cat. No. (`)
Voltage
Per Unit
Nx2000 230V 1Ph Drive 0.20 kW (HD) LTVF-N101P4BAA *
Nx2000 230V 1Ph Drive 0.40 kW (HD) LTVF-N102P4BAA *
Single Phase Nx2000 230V 1Ph Drive 0.75 kW (HD) LTVF-N104P2BAA
230VAC *
Nx2000 230V 1Ph Drive 1.50 kW (HD) LTVF-N107P5BAA *
Nx2000 230V 1Ph Drive 2.20 kW (HD) LTVF-N110P0BAA *
Nx2000+ 230V Drive 0.40kW(HD)/0.75kW(ND) LTVF-N203P1BAA *
Nx2000+ 230V Drive 0.75kW(HD)/1.50kW(ND) LTVF-N206P0BAA *
Nx2000+ 230V Drive 1.50kW(HD)/2.20kW(ND) LTVF-N209P6BAA *
l Range: 0.2 kW to 11 kW Three Phase
230VAC Nx2000+ 230V Drive 2.20kW(HD)/3.70kW(ND) LTVF-N212P0BAA *
l Simplified sensorless vector control
Nx2000+ 230V Drive 4.00kW(HD)/5.50kW(ND) LTVF-N218P0BAA *
l Built-in EMC filter to meet IEC 61800-3
Nx2000+ 230V Drive 5.50kW(HD)/7.50kW(ND) LTVF-N230P0BAA *
l Built-in Potentiometer
Nx2000+ 230V Drive 7.50kW(HD)/11.0kW(ND) LTVF-N240P0BAA *
l DIN Rail mounting for Side-by-Side installation
Nx2000+ 415V Drive 0.40kW(HD)/0.75kW(ND) LTVF-N402P0BAA *
l Built-in PID
Nx2000+ 415V Drive 0.75kW(HD)/1.50kW(ND) LTVF-N403P1BAA *
l Built-in Brake Control
Nx2000+ 415V Drive 1.50kW(HD)/2.20kW(ND) LTVF-N405P1BAA *
l Conformal Coating complying to
Three Phase Nx2000+ 415V Drive 2.20kW(HD)/3.70kW(ND) LTVF-N406P9BAA
IEC 60721-3-3 class 3C3 Avg. 415VAC *
l Built-in RS485 Modbus RTU Nx2000+ 415V Drive 4.00kW(HD)/5.50kW(ND) LTVF-N410P0BAA *
l Interface: Nx2000+ 415V Drive 5.50kW(HD)/7.50kW(ND) LTVF-N416P0BAA *
Nx2000: 5DI, 2DO (R), 2AI (V & V/I), 1AO (V) Nx2000+ 415V Drive 7.50kW(HD)/11.0kW(ND) LTVF-N423P0BAA *
Nx2000+: 5DI, 2DO (R), 2AI (V & I), 1AO (V) Note: * For prices please contact nearest branch office
Smart Series
Input M.R.P.
Description Cat. No. (`)
Voltage
Per Unit
Sx2000 VVVF 230V 1Ph Drive 0.40 kW (HD) / 0.75 kW (ND) LTVF-S10003BAA *
Single Phase Sx2000 VVVF 230V 1Ph Drive 0.75 kW (HD) / 1.5 kW (ND) LTVF-S10006BAA *
230Vac LTVF-S10010BAA
Sx2000 VVVF 230V 1Ph Drive 1.5 kW (HD) / 2.20 kW (ND) *
Sx2000 VVVF 230V 1Ph Drive 2.2 kW (HD) / 3.70 kW (ND) LTVF-S10012BAA *
Sx2000 VVVF 230V 3Ph Drive 0.40 kW (HD) / 0.75 kW (ND) LTVF-S20003BAA *
Sx2000 VVVF 230V 3Ph Drive 0.75 kW (HD) / 1.5 kW (ND) LTVF-S20006BAA *
Sx2000 VVVF 230V 3Ph Drive 1.5 kW (HD) / 2.20 kW (ND) LTVF-S20010BAA *
Sx2000 VVVF 230V 3Ph Drive 2.2 kW (HD) / 3.70 kW (ND) LTVF-S20012BAA *
Three Phase
Sx2000 VVVF 230V 3Ph Drive 4.0 kW (HD) / 5.5 kW (ND) LTVF-S20018BAA *
230Vac
Sx2000 VVVF 230V 3Ph Drive 5.5 kW (HD) / 7.5 kW (ND) LTVF-S20030BAA *
Sx2000 VVVF 230V 3Ph Drive 7.5 kW (HD) / 11 kW (ND) LTVF-S20040BAA *
l Range: 0.75kW to 90kW Sx2000 VVVF 230V 3Ph Drive 11 kW (HD) / 15 kW (ND) LTVF-S20056BAA *
l Starting Torque: 150% at 3 Hz for V/F, Sx2000 VVVF 230V 3Ph Drive 15 kW (HD) / 18.5 kW (ND) LTVF-S20069BAA *
200% at 0.5Hz for Sensorless Vector Control Sx2000 VVVF 415V Drive 0.40 kW (HD) / 0.75 kW (ND) LTVF-S40002BAA *
l Built-in Brake Control Sx2000 VVVF 415V Drive 0.75 kW (HD) / 1.50 kW (ND) LTVF-S40003BAA *
l Built-in PLC functionality Sx2000 VVVF 415V Drive 1.50 kW (HD) / 2.20 kW (ND) LTVF-S40005BAA *
l Peer to Peer Communication to share I/O’s Sx2000 VVVF 415V Drive 2.20 kW (HD) / 3.7 kW (ND) LTVF-S40007BAA *
l Conformal Coating complying to IEC Sx2000 VVVF 415V Drive 4.00 kW (HD) / 5.50 kW (ND) LTVF-S40010BAA *
60721-3-3 Class 3C3 Avg. Sx2000 VVVF 415V Drive 5.50 kW (HD) / 7.50 kW (ND) LTVF-S40016BAA *
l Built-in RS485 Modbus RTU Sx2000 VVVF 415V Drive 7.50 kW (HD) / 11.0 kW (ND) LTVF-S40023BAA *
l Component Life Monitor Three Phase Sx2000 VVVF 415V Drive 11.0 kW (HD) / 15.0 kW (ND) LTVF-S40030BAA *
415Vac Sx2000 VVVF 415V Drive 15.0 kW (HD) / 18.5 kW (ND) LTVF-S40038BAA
l Built-in Braking Chopper till 30kW ND *
Sx2000 VVVF 415V Drive 18.5 kW (HD) / 22.0 kW (ND) LTVF-S40044BAA *
l Interface :
Sx2000 VVVF 415V Drive 22.0 kW (HD) / 30.0 kW (ND) LTVF-S40058BAA *
Upto 30kW ND: 7DI, 2DO (R+T),
Sx2000 VVVF 415V Drive 30.0 kW (HD) / 37.0 kW (ND) LTVF-S40075BAA *
2AI (V & V/I), 1AO (V/I)
Sx2000 VVVF 415V Drive 37.0 kW (HD) / 45.0 kW (ND) LTVF-S40091BAA *
From 37kW ND: 7DI, 3DO (2R+T),
Sx2000 VVVF 415V Drive 45.0 kW (HD) / 55.0 kW (ND) LTVF-S40107BAA *
2AI (V & V/I), 2AO (V & V/I)
Sx2000 VVVF 415V Drive 55.0 kW (HD) / 75.0 kW (ND) LTVF-S40142BAA *
Sx2000 VVVF 415V Drive 75.0 kW (HD) / 90.0 kW (ND) LTVF-S40169BAA *
Note:
* For prices please contact nearest branch office
Drives are covered under HS code 8504 40 90 and are charged at 18% GST.
Input M.R.P.
Description Cat. No. (`)
Voltage
Per Unit
Sx2000 VVVF 415V IP66 Drive 0.40 kW (HD) LTVF-S40001XAA *
Sx2000 VVVF 415V IP66 Drive 0.75 kW (HD) LTVF-S40003XAA *
Sx2000 VVVF 415V IP66 Drive 1.50 kW (HD) LTVF-S40004XAA *
Sx2000 VVVF 415V IP66 Drive 2.20 kW (HD) LTVF-S40006XAA *
Sx2000 VVVF 415V IP66 Drive 4.00 kW (HD LTVF-S40009XAA *
Three Phase Sx2000 VVVF 415V IP66 Drive 5.50 kW (HD) LTVF-S40012XAA
415Vac *
Sx2000 VVVF 415V IP66 Drive 7.50 kW (HD) LTVF-S40016XAA *
Sx2000 VVVF 415V IP66 Drive 11.0 kW (HD) LTVF-S40024XAA *
l Range: 0.40 to 22kW (HD)
Sx2000 VVVF 415V IP66 Drive 15.0 kW (HD) LTVF-S40030XAA *
l V/F, Slip Compensation, Sensorless Vector
Sx2000 VVVF 415V IP66 Drive 18.5 kW (HD) LTVF-S40039XAA *
Control
Sx2000 VVVF 415V IP66 Drive 22.0 kW (HD) LTVF-S40045XAA *
l Starting Torque: 150% at 3Hz for V/F, 200% at
0.5Hz for Sensorless Vector Control Note: * For prices please contact nearest branch office
l Conformal Coating complying to IEC 60721-3-3,
l Built-in PID
l Built-in Braking Chopper
l Interface: 5DI, 2DO (R+T), 2AI (V & V/I), 1AO (V/I)
Flexi Series
Input M.R.P.
Description Cat. No. (`)
Voltage
Per Unit
Fx2000 VVVF 415V Drive 0.75 kW (HD) / 1.50 kW (ND) LTVF-F40004CAA *
Fx2000 VVVF 415V Drive 1.50 kW (HD) / 2.20 kW (ND) LTVF-F40006CAA *
Fx2000 VVVF 415V Drive 2.20 kW (HD) / 3.70 kW (ND) LTVF-F40008CAA *
Fx2000 VVVF 415V Drive 3.70 kW (HD) / 4.00 kW (ND) LTVF-F40012CAA *
Fx2000 VVVF 415V Drive 5.50 kW (HD) / 7.50 kW (ND) LTVF-F40016CAA *
Fx2000 VVVF 415V Drive 7.50 kW (HD) / 11.0 kW (ND) LTVF-F40024CAA *
Fx2000 VVVF 415V Drive 11.0 kW (HD) / 15.0 kW (ND) LTVF-F40030CAA *
Fx2000 VVVF 415V Drive 15.0 kW (HD) / 18.5 kW (ND) LTVF-F40039CAA *
Fx2000 VVVF 415V Drive 18.5 kW (HD) / 22.0 kW (ND) LTVF-F40045CAA *
Fx2000 VVVF 415V Drive 22.0 kW (HD) / 30.0 kW (ND) LTVF-F40061CAA *
l Range: 0.75kW to 375kW (HD) Fx2000 VVVF 415V Drive 30.0 kW (HD) / 37.0 kW (ND) LTVF-F40075CAA *
l Ideal for Heavy Duty Applications - Crane, Fx2000 VVVF 415V Drive 37.0 kW (HD) / 45.0 kW (ND) LTVF-F40091CAA *
Three Phase
Winder, Textile Application, Plastic extruders Fx2000 VVVF 415V Drive 45.0 kW (HD) / 55.0 kW (ND) LTVF-F40110CAA *
415Vac
l Starting Torque: 250% at 0Hz for Closed Loop Fx2000 VVVF 415V Drive 55.0 kW (HD) / 75.0 kW (ND) LTVF-F40152CAA *
Vector Control Fx2000 VVVF 415V Drive 75.0 kW (HD) / 90.0 kW (ND) LTVF-F40183CAA *
l Overload Capacity: 200% for 3 sec and 150% Fx2000 VVVF 415V Drive 90.0 kW (HD) / 110 kW (ND) LTVF-F40223AAA *
for 1 min Fx2000 VVVF 415V Drive 110 kW (HD) / 132 kW (ND) LTVF-F40264AAA *
Built-in Crane function Fx2000 VVVF 415V Drive 132 kW (HD) / 160 kW (ND) LTVF-F40325AAA
l
*
l Optional Smart PLC Card Fx2000 VVVF 415V Drive 160 kW (HD) / 185 kW (ND) LTVF-F40370AAA *
l Conformal Coating complying to Fx2000 VVVF 415V Drive 185 kW (HD) / 220 kW (ND) LTVF-F40432AAA *
IEC 60721-3-3 Class 3C3 Avg. Fx2000 VVVF 415V Drive 220 kW (HD) / 285 kW (ND) LTVF-F40547AAA *
l Built-in RS485 Modbus RTU Fx2000 VVVF 415V Drive 285 kW (HD) / 315 kW (ND) LTVF-F40613AAA *
l Built-in DC Reactor from 22kW to 220kW HD Fx2000 VVVF 415V Drive 315 kW (HD) / 375 kW (ND) LTVF-F40731AAA *
l Built-in Braking Chopper till 22kW HD Fx2000 VVVF 415V Drive 375 kW (HD) / 450 kW (ND) LTVF-F40877AAA *
l Interface : 8DI, 3DO (2R+1T), 2AI (V & I), Note:
2AO (V & I)
* For prices please contact nearest branch office
Drives are covered under HS code 8504 40 90 and are charged at 18% GST.
V/F, Slip Compensation Hx2000 VVVF 415V Drive 22.0 kW (ND) LTVF-H40045BAA *
l
Built-in RTC for Scheduling Hx2000 VVVF 415V Drive 30.0 kW (ND) LTVF-H40061BAA *
l
l Built-in EMC filter class C3 Hx2000 VVVF 415V Drive 37.0 kW (ND) LTVF-H40075BAA *
l Password Protection Hx2000 VVVF 415V Drive 45.0 kW (ND) LTVF-H40091BAA *
l Multi-motor Control Hx2000 VVVF 415V Drive 55.0 kW (ND) LTVF-H40107BAA *
l Built-in Payback Counter Hx2000 VVVF 415V Drive 75.0 kW (ND) LTVF-H40142BAA *
l Dry Pump Detection Hx2000 VVVF 415V Drive 90.0 kW (ND) LTVF-H40169BAA *
l Built-in 4 PID (1 Main & 3 EPID)
Note: * For prices please contact nearest branch office
l Built-in RS485 Communication, BACnet, Modbus-RTU, Metasys N2
l Global Specification Compliant - CE, UL (Plenum Rated)
l Conformal Coating complying to IEC 60721-3-3, Class 3C2 (3C3 Avg.)
l Interface: 7DI, 6DO (5R+1T), 2AI (V & V/I), 2AO (V & V/I)
Features :
• Inbuilt Real Time Clock (RTC)
• Compact Design - Saves valuable space in panel
• On-board USB provides quick setup and backup
• Extensive voltage range - 200VAC to 525VAC, 380VAC to 690VAC
• IE3 Compatible and 99% energy efficient when running
• Smart cards Analog output Optional features for advanced applications
• Communication options: DeviceNet, Ethernet/IP, Modbus RTU,
Modbus TCP, Profibus, Profinet
Digital Soft Star ters [8504]
l Starts per hour count EMX4i, 940A, Main 200-525Vac, CTR 110-240Vac EMX4i-0940B-511
l Power through function available *
EMX4i, 1070A, Main 200-525Vac, CTR 110-240Vac EMX4i-1070B-511 *
l Scheduling based on RTC
EMX4i, 1230A, Main 200-525Vac, CTR 110-240Vac EMX4i-1230B-511 *
EMX4i, 1250A, Main 200-525Vac, CTR 110-240Vac EMX4i-1250B-511 *
EMX4i, 735A, Main 200-525Vac, CTR 110-240Vac EMX4i-0735C-511 * External bypass
EMX4i, 830A, Main 200-525Vac, CTR 110-240Vac EMX4i-0830C-511 contactor
* (AC1 rating)
EMX4i, 1025A, Main 200-525Vac, CTR 110-240Vac EMX4i-1025C-511 * $ All protections
Ordering Information for EMX4 Soft Starter
EMX4i, 1170A, Main 200-525Vac, CTR 110-240Vac EMX4i-1170C-511 * remain active during
bypass operation
E M X 4 B EMX4i, 1220A, Main 200-525Vac, CTR 110-240Vac EMX4i-1220C-511 *
Keypad
1 = with keypad
Control voltage
C1 = 110~120 VAC or 220~240 VAC
C2 = 24 VAC/VDC
Mains voltage
V5 = 200 ~ 525 VAC
V7 = 380 ~ 600 VAC
Nominal Current Rating
Soft-starter Model
e = EMX4e Soft-starter
We recommend the use of :
i = EMX4i Soft-starter
Note: 1. Line Contactor : This will isolate and protect the soft starter SCR's from any voltage
* For prices please contact nearest branch office transient while it's not in operation.
Soft Starters are covered under HS code 8504 40 90 and are charged 2. Semiconductor fuses : This will protect the starter SCR's during starting and stopping
at 18% GST. states from current transient's and excess I²T.
Optional Modules/Cards for CSX / CSXi / EMX4 • Soft Start / Soft Stop
• Compact
• Complements existing motor protection
• Truly plug & play
• Communication options available
PIC-RC-01 2. Bypass Contactor (For models without built-in bypass) : This will
Remote Keypad Card, EMX4 * bypass and protect the soft starter SCR's while in running state from
Remote Keypad Card & Keypad EMX4 PIC-RC-02 * Current and Voltage transient's.
Remote Keypad with cable & mounting kit, EMX4 PIC-RK-01 * 3. Semiconductor fuses : This will protect the starter SCR's during
starting and stopping states from current transient's and excess I²T.
Smart Control Card Pump Application, EMX4 SCC-PC-01 *
Ground Fault + Ethernet IP Card EMX4 PIC-EI-02 * Note:
EMX3 soft starters will be available till stock lasts
Ground Fault + Modbus RTU Card EMX4 PIC-MB-02 *
* For prices please contact nearest branch office
Ground Fault + Modbus TCP Card EMX4 PIC-MT-02 * Soft Starters are covered under HS code 8504 40 90 and are charged
at 18% GST.
Ground Fault + Profinet Card EMX4 PIC-PN-02 *
Screen gesture
Flick to change screens.
No extra switching button is needed to change screens.
Object gesture
Select the object you want and then swipe and flick it.
Object list
• Logging trend graph • View logging history • View history alarms
Multi-touch
Use multi-touch to protect your system from undesired errors.
FTP Client
• FTP client is an object that can connect to the FTP
sever, display the list of files and directories on the
FTP server, and download the selected file.
• PDF files on an FTP server can be displayed using
a PDF viewer object.
VNC Viewer
• Remotely monitoring PC or HMI using VNC Viewer
is available
- Download VNC server to HMI using XP-Manager.
- Install a universal VNC server on your PC.
(Ultra VNC, Real VNC, etc.)
• Add ‘VNC Viewer’ object to the project screen.
HMI
Features:
• Large Memory: Upto 128MB display data and 1MB back-up memory
• Various Communication Interface: Ethernet / RS-232C / RS-422/485
• USB host and device
• SD memory card interface
• Web server / Data monitoring
• Remote controlling and monitoring
• Presence sensor (within 1m)
Range:
• Sound Output
• Text Display
• 4" ~ 15" TFT color LCD
Note:
* Upgraded version of our s-XT series HMI
** Upgraded version with SD card slot for our existing s-XT series HMI
Note: Standard Pack Quantity for MCB : SP - 12 Nos., DP - 6 Nos., TP - 4 Nos., FP - 3 Nos.
* For details, please contact nearest branch office
Note: Standard Pack Quantity for MCB : SP - 12 Nos., DP - 6 Nos., TP- 4 Nos., FP - 3 Nos.
* For details, please contact nearest branch office
DC MCBs as per IEC 60947-2 [8536]
Rated Voltage:130V DC (for SP), 250V DC (for DP) Rated Voltage: 250V DC (for SP), 500V DC (for DP)
with breaking capacity of 6 kA - BB Series DC MCBs with breaking capacity of 10 kA - BJ Series DC MCBs
Modules M.R.P. Modules M.R.P.
Rating 1 Mod = Cat. No. (`) Rating 1 Mod = Cat. No. (`)
17.5mm Per Unit 17.5mm Per Unit
Single Pole (SP) Single Pole (SP)
0.5A 1 BB10E5DC 630 0.5A 1 BJ10E5DC 770
1A 1 BB1001DC 630 1A 1 BJ1001DC 770
2A 1 BB1002DC 630 2A 1 BJ1002DC 770
3A 1 BB1003DC 630 3A 1 BJ1003DC 770
4A 1 BB1004DC 630 4A 1 BJ1004DC 770
6A 1 BB1006DC 545 6A 1 BJ1006DC 630
10A 1 BB1010DC 545 10A 1 BJ1010DC 630
16A 1 BB1016DC 545 16A 1 BJ1016DC 630
20A 1 BB1020DC 545 20A 1 BJ1020DC 630
25A 1 BB1025DC 545 25A 1 BJ1025DC 630
32A 1 BB1032DC 545 32A 1 BJ1032DC 630
40A 1 BB1040DC 715 40A 1 BJ1040DC 870
50A 1 BB1050DC 715
63A 1 BB1063DC 715
Double Pole (DP) Double Pole (DP)
0.5A 2 BB20E5DC 1345 0.5A 2 BJ20E5DC 1610
1A 2 BB2001DC 1345 1A 2 BJ2001DC 1610
2A 2 BB2002DC 1345 2A 2 BJ2002DC 1610
3A 2 BB2003DC 1345 3A 2 BJ2003DC 1610
4A 2 BB2004DC 1345 4A 2 BJ2004DC 1610
6A 2 BB2006DC 1180 6A 2 BJ2006DC 1360
10A 2 BB2010DC 1180 10A 2 BJ2010DC 1360
16A 2 BB2016DC 1180 16A 2 BJ2016DC 1360
20A 2 BB2020DC 1180 20A 2 BJ2020DC 1360
25A 2 BB2025DC 1180 25A 2 BJ2025DC 1360
32A 2 BB2032DC 1180 32A 2 BJ2032DC 1360
40A 2 BB2040DC 1600 40A 2 BJ2040DC 1935
50A 2 BB2050DC 1600
Note: Standard Pack Quantity for MCB : SP - 12 Nos., DP - 6 Nos.
63A 2 BB2063DC 1600
for Exora MCBs [8538] Auxiliary Contact - 6A , 240V AC, (1NO+1NC), 0.5 Mod BZA11006 845
Shunt Release - 240V AC, 1 Mod BZS00240 2310
Trip Alarm Contact - 6A, 240V AC, (1NO+1NC), 0.5 Mod BZT11006 990
1
Single Pole (SP)
st
Time in 6A 1 AU10Q10063B 315 AU10Q10063C 315
• Conforms to IS/IEC 60898 - 10kA India
• Available in SP, DP, TP, FP, SPN & 10A 1 AU10Q10103B 315 AU10Q10103C 315
TPN version 16A 1 AU10Q10163B 315 AU10Q10163C 315
20A 1 AU10Q10203B 315 AU10Q10203C 315
Isolators [8536]
Range Highlights
• Conforms to IEC 60947-3
• Utilization category AC-22A
• Available in DP, TP and FP versions in 40A, 63A, 80A & 100A ratings
Type-AC Type-Adi
Rating Sensitivity M.R.P. (`) Rating Sensitivity M.R.P. (`)
Module CAT Nos. Module CAT Nos.
Per Unit Per Unit
2P AC 2P Adi
10mA 2 AUF3C200601 4605 30mA 2 AUF3D200603 6100
30mA 2 AUF3C200603 4605 6A 100mA 2 AUF3D200610 6720
6A
100mA 2 AUF3C200610 4705 300mA 2 AUF3D200630 6970
300mA 2 AUF3C200630 4755 30mA 2 AUF3D201003 6100
10mA 2 AUF3C201001 4605 10A 100mA 2 AUF3D201010 6720
30mA 2 AUF3C201003 4605 300mA 2 AUF3D201030 6970
10A
100mA 2 AUF3C201010 4705 30mA 2 AUF3D201603 6100
300mA 2 AUF3C201030 4755 16A 100mA 2 AUF3D201610 6720
10mA 2 AUF3C201601 4605 300mA 2 AUF3D201630 6970
30mA 2 AUF3C201603 4605 30mA 2 AUF3D202003 6100
16A
100mA 2 AUF3C201610 4705 20A 100mA 2 AUF3D202010 6720
300mA 2 AUF3C201630 4755 300mA 2 AUF3D202030 6970
30mA 2 AUF3C202003 4605 30mA 2 AUF3D202503 6100
20A 100mA 2 AUF3C202010 4705 25A 100mA 2 AUF3D202510 6720
300mA 2 AUF3C202030 4755 300mA 2 AUF3D202530 6970
30mA 2 AUF3C202503 4605 30mA 2 AUF3D203203 6100
25A 100mA 2 AUF3C202510 4705 32A 100mA 2 AUF3D203210 6720
300mA 2 AUF3C202530 4755 300mA 2 AUF3D203230 6970
30mA 2 AUF3C203203 4605 30mA 2 AUF3D204003 6100
32A 100mA 2 AUF3C203210 4705 40A 100mA 2 AUF3D204010 6720
300mA 2 AUF3C203230 4755 300mA 2 AUF3D204030 6970
30mA 2 AUF3C204003 4605 30mA 4 AUF3D206303 7440
40A 100mA 2 AUF3C204010 4705 63A 100mA 4 AUF3D206310 7875
300mA 2 AUF3C204030 4755 300mA 4 AUF3D206330 7940
30mA 4 AUF3C206303 5765 4P Adi
63A 100mA 4 AUF3C206310 6115 30mA 7.5 AUF3D401603 6725
300mA 4 AUF3C206330 6165 16A 100mA 7.5 AUF3D401610 7480
4P AC 300mA 7.5 AUF3D401630 7630
30mA 7.5 AUF3C401603 5215 30mA 7.5 AUF3D402003 6725
16A 100mA 7.5 AUF3C401610 5805 20A 100mA 7.5 AUF3D402010 7480
300mA 7.5 AUF3C401630 5920 300mA 7.5 AUF3D402030 7630
30mA 7.5 AUF3C402003 5215 30mA 7.5 AUF3D402503 6725
20A 100mA 7.5 AUF3C402010 5805 25A 100mA 7.5 AUF3D402510 7480
300mA 7.5 AUF3C402030 5920 300mA 7.5 AUF3D402530 7630
30mA 7.5 AUF3C402503 5215 30mA 7.5 AUF3D403203 6940
25A 100mA 7.5 AUF3C402510 5805 32A 100mA 7.5 AUF3D403210 7485
300mA 7.5 AUF3C402530 5920 300mA 7.5 AUF3D403230 7640
30mA 7.5 AUF3C403203 5385 30mA 7.5 AUF3D404003 7045
32A 100mA 7.5 AUF3C403210 5810 40A 100mA 7.5 AUF3D404010 7485
300mA 7.5 AUF3C403230 5935 300mA 7.5 AUF3D404030 7675
30mA 7.5 AUF3C404003 5470 30mA 7.5 AUF3D406303 8440
40A 100mA 7.5 AUF3C404010 5810 63A 100mA 7.5 AUF3D406310 8610
300mA 7.5 AUF3C404030 5955 300mA 7.5 AUF3D406330 8610
30mA 7.5 AUF3C406303 6555 30mA 12 AUF3D408003 24935
63A 100mA 7.5 AUF3C406310 6675 80A 100mA 12 AUF3D408010 25495
300mA 7.5 AUF3C406330 6675 300mA 12 AUF3D408030 25495
30mA 12 AUF3C408003 24935 30mA 12 AUF3D410003 26660
80A 100mA 12 AUF3C408010 25495 100A 100mA 12 AUF3D410010 27295
300mA 12 AUF3C408030 25495 300mA 12 AUF3D410030 27295
30mA 12 AUF3C410003 26660
* For technical details, please contact nearest branch office
100A 100mA 12 AUF3C410010 27295
300mA 12 AUF3C410030 27295
EXORA DBs
IP 30 - Single Door IP 43 - Metal Door IP 43 - Glazed Door IP 30 - Single Door IP 43 - Metal Door IP 43 - Glazed Door
4 way 8 2+2+2 4+4+4 DBHPI004DD 8085 4 way 8 4+4+4 4+4+4 DBPSG004SD 10780
6 way 8 2+2+2 6+6+6 DBHPI006DD 9650 6 way 8 4+4+4 6+6+6 DBPSG006SD 11660
8 way 8 2+2+2 8+8+8 DBHPI008DD 11575 8 way 8 4+4+4 8+8+8 DBPSG008SD 12600
12 way 8 2+2+2 12+12+12 DBHPI012DD 15820 12 way 8 4+4+4 12+12+12 DBPSG012SD 14505
4 way 8 2+2+2 4+4+4 DBHPI00454 18620 6 way 8 4+4+4 6+6+6 DBPSG006DD 13850
6 way 8 2+2+2 6+6+6 DBHPI00654 22185 8 way 8 4+4+4 8+8+8 DBPSG008DD 15450
8 way 8 2+2+2 8+8+8 DBHPI00854 24495 12 way 8 4+4+4 12+12+12 DBPSG012DD 19170
6 way 8 2+2+2 6+6+6 DBTPI006DD 9960 4 way MCCB 4+4+4 4+4+4 DBPGL004SD 15095
8 way 8 2+2+2 8+8+8 DBTPI008DD 12490 6 way MCCB 4+4+4 6+6+6 DBPGL006SD 17375
10 way 8 2+2+2 10+10+10 DBTPI010DD 13095 8 way MCCB 4+4+4 8+8+8 DBPGL008SD 19955
16 way 8 2+2+2 16+16+16 DBTPI016DD 15820 4 way MCCB 4+4+4 4+4+4 DBPGL004DD 16895
12 way MCCB* 2+2+2 12+12+12 DBTPL012DD 14840 6 way MCCB 4+4+4 6+6+6 DBPGL006DD 19320
DB Accessories
Busbar - Fork Type [8538] Blanking Plates [8538]
Highlights Highlights
l Available in Single Pole, Double Pole, Three Pole and l Available in One module and
Four Pole versions Half module
l Material : Copper
M.R.P. Std.
Description Cat. Nos. (`) Pack
Per Unit Qty.
One Module BKP10 25 10
M.R.P. Std. Half Module BKP05 25 10
Description Cat. Nos.. (`) Pack
Per Unit Qty.
SP 13 Mod BSP13 355 5
IP 30 - Single Door IP 43 - Metal Door IP 43 - Glazed Door IP 30 - Single Door IP 43 - Metal Door IP 43 - Glazed Door
* Suitable for 3 Pole & 4 Pole DU100H, DU100D, DU125D, DU125H &
DN0 MCCB as incomer
12 way MCCB 12+12+12 DBVTH012SD 25140 10 A, 2 Pin + SC^ P+N 1 DBMPS110SD 1835
16 way MCCB 16+16+16 DBVTH016SD 30845 20 A, 2 Pin + SC^ P+N 1 DBMPS120SD 1970
IP 43 - Metal Door 20 A, 2 Pin + SC^ P+N 2 DBMPS220SD 2140
4 way MCCB 4+4+4 DBVTH004DD 17070 20 A, 3 Pin + SC^ 3P 3 DBMPS320SD 3625
6 way MCCB 6+6+6 DBVTH006DD 19390 32 A, 3 Pin + SC^ 3P 3 DBMPS332SD 4285
8 way MCCB 8+8+8 DBVTH008DD 21325 32 A, 3 Pin + SC^ 3P 4 DBMPS432SD 4560
12 way MCCB 12+12+12 DBVTH012DD 26555 63 A, 5 Pin + SC^ 3P+N+E 4 DBMPS463SD 15450
16 way MCCB 16+16+16 DBVTH016DD 34685 Plastic Plug & Sockets
IP 30 - Metal Door
M.R.P.
Description No. of Modules Cat. Nos. (`)
Per Unit M.R.P.
Description No. of Pins Cat. Nos. (`)
IP 30 - Metal Door Per Unit
2 way 2 DBENC002SD 745 10 A, 2 Pin + SC^ P+N MPS210S 180
3 way 3 DBENC003SD 745 20 A, 2 Pin + SC^ P+N MPS220S 200
4 way 4 DBENC004SD 745 20 A, 3 Pin + SC^ 3P MPS320S 275
6 way 6 DBENC006SD 1110 32 A, 3 Pin + SC^ 3P MPS332S 465
^ SC-Scraping Earth
Note: Standard pack quantity - 20 nos.
Highlights M.R.P.
No. of Modules
DB Type Description Cat. Nos. (`)
l Distribution Boards equipped with provisions to mount TV / Telephone Incomer + Outgoing Per Unit
splitters
IP 43 - Metal Door
l Available in SPN & TPN DBs
6 way 2 4 DBSPN006DDTV 4090
M.R.P.
Description Cat. Nos. (`)
Per Unit
CEB for SPN DBs
CEB-SPN Double Door, 16 way DBSPN016CB 1515 CEB for VTPN DBs
CEB-VTPN Double Door,
CEB-SPN Double Door, 18 way DBSPN018CB 1565 DBVTMXXXCB 1075
Modular Incomer
CEB for TPN DBs CEB-VTPN Double Door,
DBVTXXXXCB 3830
MCCB Incomer
CEB-TPN Double Door, 4 way DBTPN004CB 1085
CEB for FLEXI DBs
CEB-TPN Double Door, 6 way DBTPN006CB 1525
CEB for Flexi DBs with
CEB-TPN Double Door, 8 way DBTPN008CB 1920 14 Modules per Row DBROWX14CB 1070
CEB-TPN Double Door, 12 way DBTPN012CB 3185 CEB for Flexi DBs with 1300
DBROWX16CB
16 Modules per Row
CEB-TPN Double Door, 16 way DBTPN016CB 3215
CEB for Phase Segregated DBs
CEB-TPE Double Door, 4 way DBTPE004CB 1040
CEB-PSG Double Door, 4 way DBPSG004CB 2815
CEB-TPE Double Door, 6 way DBTPE006CB 1475
CEB-PSG Double Door, 6 way DBPSG006CB 3355
CEB for Horizontal PPI DBs
CEB-PSG Double Door, 8 way DBPSG008CB 3720
CEB-Horz. PPI Double Door, 4 way DBHPI004CB 1610
CEB-PSG Double Door, 12 way DBPSG012CB 4130
CEB-Horz. PPI Double Door, 6 way DBHPI006CB 2005
CEB for Phase Selector DBs
CEB-Horz. PPI Double Door, 8 way DBHPI008CB 2520
CEB-Phase Selector Double Door, 4 way DBPSR004CB 1190
CEB-Horz. PPI Double Door, 12 way DBHPI012CB 3155
CEB-Phase Selector Double Door, 6 way DBPSR006CB 1340
CEB-Horz. PPI Double Door, 16 way DBHPI016CB 3435
CEB-Phase Selector Double Door, 8 way DBPSR008CB 2175
CEB for Tier PPI DBs
CEB-Phase Selector Double Door, 10 way DBPSR010CB 2505
CEB-Tier PPI Double Door, 6 way DBTPI006CB 1450
CEB-Phase Selector Double Door, 12 way DBPSR012CB 2715
CEB-Tier PPI Double Door, 8 way DBTPI008CB 1520
Comprehensive
E&A offers the following services, partnering you
in your maintenance of low voltage distribution products :
• Regular Maintenance
Service Support • Preventive Maintenance Programme
• On Call
• Annual Maintenance Contract
• Product Support for Managing Obsolescence -
Retrofitting & Upgradation of your switchgear products.
Multiple
Brand Agnostic Trainings
, , Vadodara, Delhi & Kolkata
cover:
Low Voltage & Medium Voltage Switchgear
Switchboard Electrical Design
AC Drives & Building Management Solutions 50 Thousand plus
satisfied participants
Protective Relays & Earthing
over digital platform
Power Quality Solutions
Pune Lucknow
L&T Electrical & Automation L&T Electrical & Automation L&T Electrical & Automation
Training Centre Training Centre Training Centre,
T-156 / 157, MIDC, C-6 & 7, UPSIDC, A-25, Imperia Complex, First Floor,
Bhosari, P. O. Sarojininagar, Mohan Cooperative Industrial Estate,