Description Page#

The Overview of the EDRT - Remote Throttle System 1

The Engine Input Configuration Plug 2

The Dash Crane/Truck Switch & Chassis Harness Connections 3

The ECM Connector Wire Arrangement for Remote Throttle & Set RPM for a Caterpillar Engine 4

The Truck Chassis Remote Neutral Start Wire Arrangement Using Starter Solenoid 5

The Truck Chassis Remote Neutral Start Wire Arrangement Using Key Switch 6

The TPS Wire Arrangement For A Caterpillar 7

The Crane Feed Harness Terminal Strip 8

The Overall Schematic of the System 9

The Remote Throttle Engine & Set RPM Parameters for Caterpillar 10
Engine Parameter Settings

Caterpillar:

RPM Style: Remote Throttle Pedal With One Set Speed


Remote RPM Switch Style: Throttle Pedal Sensor & On/Off Toggle Switch
Engine Manufacture: Caterpillar
Engine Models: 3126,C-10,C-12,C-15,C-16,3406E
ECM Model: Adam I, II & III

Idle Parameters: Idle Vehicle Speed Limit - (Set to Min. 10mph)

Idle RPM Limit - (Set to Max PTO Pump RPM or 1200 rpm)

Idle/PTO RPM Ramp Rate - 1000 (rpm/sec)

Idle/PTO Bump RPM - N/A

Dedicated PTO Parameters: PTO Configuration - Remote Throttle

PTO Top Engine Limit - Set to Max PTO Pump RPM

PTO Engine RPM Set Speed - 0 rpm(Default)

PTO Engine RPM Set Speed A - Set Speed RPM

PTO Engine RPM Set Speed B - 0 rpm(Default)

PTO to Set Speed - No (Default)

PTO Cab Controls RPM Limit - Low Idle

PTO Vehicle Speed Limit - (Set to 100 mph)

Torque Limit - 2500 lb-ft (Default)

PTO Shutdown Time - 0 minutes(Default)

PTO Shutdown Timer Maximum RPM - 2120 rpm (Default)

PTO Activates Cooling Fan - Continuous

Input Selections : Input #2 - set to J1/P1:46


3126 - Input #7 - set to J1/P1:46

Note: Some of these settings may have to be altered according to your customer’s needs. The above settings are