ML70S Programming
ML70S Programming
0x)
When the lift is stand by position, by pressing ENTER button for 2 seconds, programming
mode starts.
PARAMETERS
A.Language
C.Door Settings
01:A DoorTypeSetting Floor 00 CarDoor (For each floor, A side door type can be set one by one and
can be set at the same time)
02:B DoorTypeSetting Floor 00 NoDoor (For each floor, B side door type can be set one by one and
can be set at the same time)
03:Door A Limit Type Without Limit With Limit, Without Limit
(Limit type selection of A side door mechanism)
04:Door B Limit Type Without Limit With Limit, Without Limit
(Limit type selection of B side door mechanism)
05:Door A Relay Set MLKABINR RA/RK ML70S RA/RK, MLKABIN-R RA/RK, MLKABIN-R ER2/ER1
(Selection of A side door open/close signals that will be
connected to which relays)
06:Door B Relay Set MLKABIN-R ER2/ER1 ML70S RA/RK, MLKABIN-R RA/RK, MLKABIN-R ER2/ER1
(Selection of B side door open/close signals that will be
connected to which relays)
07:Wait AtFloor Time 5 seconds 1-99 seconds
(At full automatic door systems, stay opened time of
automatic door; at only indoor systems, if the door doesn’t
open after the car stopped, selection the time of the next call)
08:PhotocellBlockT. Passive Passive, 1,2,..99 seconds
(Selection the time of cutting photocell signal and starting the
nudging signal)
09:DoorOpenInsp.Time 180 seconds 10-180 seconds
(When the door stayed open, selection the time of warning)
10:CloseButton Delay 2 seconds Passive, 1,2,..20 seconds
(Delay time of close buton detection)
11:Advanced DoorOpen Passive Passive, Active
12:Dir.-OpenD. Style Passive Passive, Active
(If parameter value is passive, when the direction arrows are
on, the same floor call is not imported. If parameter value is
active, when the direction arrows are on and if the same floor
call is come, the automatic door is opened)
D.Display Settings
Assignable Functions
1- Inspection
2- Car Lamp
3- Re-levellingSpeed (Re-levelling speed output at electrical lifts)
4- Ups Contactor (UPS-Inverter contactor at UPS rescue)
5- Gong
6- Hyd.Re-lev. Motor (Lower power motor output at re-levelling in hydraulic lifts)
7- Middle Speed (Output when the target floor is the nearest floor at electrical lifts)
8- Gray-Code M0
9- Gray-Code M1
10- Gray-Code M2
11- Gray-Code M3
12- Gray-Code M4
13- Binary M0
14- Binary M1
15- Binary M2
16- Binary M3
17- Binary M4
18- Nudging (At full automatic door lifts, output at the end of photocell blocking time)
19- At Floor Signal
20- Up Arrow
21- Down Arrow
22- Fault (Inverse) (At normal position, there is always output; at fault position, output is cut off)
23- Overload
24- Out Of Service
25- Lirpomp
26- Middle Speed 2
G.Maintenance Sets
H.Evacuation Sets
I.Shaft Learning
K.Gong Settings
03:Gong Type Single Sound Single Sound (Single sound on up and down direction)
Double Sound (Double sound on up and down direction)
UpSingle,DownDbl. (Up direction single sound, down
direction double sound)
UpDbl.,DownSingle (Up direction double sound, down
direction single sound)
(Selection of gong type on floor cards)