ML70S Programming

This document provides instructions for entering programming mode on a lift controller and summarizes the programmable parameters. It can be entered by pressing the ENTER button for 2 seconds when the lift is in standby position. The document lists 30 programmable parameters under topics like Language, System Settings, Door Settings, and more. Parameters include lift type, number of floors, car lamp time, parking floor, and other settings. Subprograms can be selected using up and down buttons and parameters can be changed using up and down buttons before storing with ENTER.

Uploaded by

Bojan Drljacha
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
144 views

ML70S Programming

This document provides instructions for entering programming mode on a lift controller and summarizes the programmable parameters. It can be entered by pressing the ENTER button for 2 seconds when the lift is in standby position. The document lists 30 programmable parameters under topics like Language, System Settings, Door Settings, and more. Parameters include lift type, number of floors, car lamp time, parking floor, and other settings. Subprograms can be selected using up and down buttons and parameters can be changed using up and down buttons before storing with ENTER.

Uploaded by

Bojan Drljacha
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

PROGRAMMING (Ver:1.

0x)
 When the lift is stand by position, by pressing ENTER button for 2 seconds, programming
mode starts.

Main Program Sub Program Name

PROGRAM MAIN MENU B.System Settings


A.Language -----------------------------------
>B.System Settings 01:Lift Type
C.Door Settings -> Electrical

Sub Program Names Parameter No Registered Parameter Program Name


Value
When this arrow on screen When this arrow on screen
can be entered to sub program parameter can be changed

 You can choose sub program by using UP and DOWN buttons.


 To exit the programming mode ESC button in the main menu is used, “ENTER to ExitProgram”
is displayed on LCD screen. Press ENTER button and exit the programming mode; to return the
main menu again press ESC button.
 When ENTER button in the main menu is pressed, the sub program which has arrow on the
screen starts. And you can select the sub program with ENTER button again.
 If the program has parameter, an arrow appears at the beginning of the fourth line of
LCD screen. You can change the parameter value by using UP and DOWN buttons. To store the
value, press the ENTER button and return the menu. By pressing the ESC button the registered
value is valid and you can return the sub menu.

PARAMETERS

Program Factory Set Parameters / Explanations

A.Language

A.Language Turkce Turkce, English, PyccKnñ


B.System Settings

01:Lift Type Electrical Electrical


Hydraulic
Gearless
02:Command Type OneBt.TwoWayColl. OneBt.OneWayColl.
(There is one button on the floors in this command type. If
this button connected to which direction, floor calls are
collective at that direction. Car calls are collective in both
directions)
OneBt.TwoWayColl.
(There is one button on the floors in this command type. If
this button connected to which direction, floor calls are
collective in both directions. Car calls are collective in both
directions)
SelectiveCollect
(Car calls are collective in both directions, floor down calls
are collective in down direction, floor up calls are collective
in up direction)
03:Number Of Floor 16 2-32
04:Car Lamp Time 5 seconds 1-20 seconds
(The duration of car lamp ON)
05:Lock Wait Time 15 seconds 5-25 seconds
(After CAM energized waiting time for lock signal)
06:Maximum HighSpeed 15 seconds 10-100 seconds
(Max moving time at high speed between two floors)
07:Maximum Low Speed 10 seconds 5-100 seconds
(Max moving time at low speed)
08:Parking Time 30 seconds 10-100 seconds
(On stand-by, time of moving to park floor)
09:Park Floor Passive Passive, 0,1,..31
(On stand-by, park floor to go)
10:Fire Floor Passive Passive, 0,1,..31
(Target floor when detecting fire warning signal)
11:Stop Delete Calls Passive Passive, Active
(When pressed the stop button if the parameter value is
passive, car calls are kept in the memory and vice versa)
12:Group ID Select Passive Passive
A Panel
B Panel
C Panel
D Panel

13:R-S-T Phase Ctrl Without Sequence Passive


Without Sequence
Sequential (50Hz)
Sequential (60Hz)

14:Motor PTC Control Active Passive, Active

15:Phase AcceptLevel 50 0-100


(It can be controlled phase level sensitivity, when the
parameter value is increased it can be accepted existing
phases if their voltage levels are low)

16:RX Delay Time Passive Passive, 10-5000 ms


(In speed control systems, when limit switch is on, selection
of stripping distance)

17:Inspect.Move Type To Limit Switch To Limit Switch


(In inspection mode, car is moved to up and down limit
switches)
To Exact Floor
(In inspection mode, car is moved to up and down floor
levels)

18:Star-TriangleTime 400 ms Passive, 10-5000 ms


(Selection of star-triangle relay (RT) convert time for
hydraulic lifts)

19:Motor-Valve Time 400 ms Passive, 10-5000 ms


(Motor run time after the valves closed for hydraulic lifts)
20:Hyd. Re-levelling Passive Passive, Active
(If this parameter selected active, it is allowed re-levelling
for hydraulic lifts)
21:Position Reset Passive Passive, Active
(After the power off, when the card is energized, the car is
moved to floor which has down limit bi-stable switch)
22:Maximum Car Calls 8 1-24
(Maximum car calls accepted in the cabin)

23:Stop Function Only Stop Only Stop


(When stop (120) signal is cut, only lift is stopped; no
operation is done about the car calls. End of the floor wait
time, back to the normal working position)
Hold Calls
(When stop (120) signal is cut, all car calls are registered
and lift is stopped. After the stop signal, wait for any car call.
After the car call, registered calls and the new call is collated
and back to the normal working position)
24:Top Less Floor Passive Passive, 1,2,..5
(In doublex working, up direction missing floor number of
one of the lifts)
25:Lower Less Floor Passive Passive, 1,2,..5
(In doublex working, down direction missing floor number of
one of the lifts)
26:Gray Binary Start 0 0,1,..5
(At the up missing floor lifts, selection of the starting number
of gray-code or binary output)
27:Car Call Cancel Passive Passive, Active
(If this parameter is selected active, accepted call by pressing
the button inside the car is canceled by pressing this button
once again)
28:Car Card Select KABIN-R & KABIN-K KABIN-R & KABIN-K
SERI65 & INT65
(Selection of car communication cards)
29:Floor Detection Active M0 Pulse 2 Magnet
M0 Pulse 4 Magnet
M0/M1 Pulse
Encoder
30:OSG/Brake Control Passive Passive, Active
Cancel A3 (Puk:000000)
(At geary machine systems, over speed governor selenoid
control card MLA3 must be used. If it is used for the lifts that
is not suitable to En81-1/2 + A3 standards, to do this
parameter “passive”, ML70S user must declear to our firm
with writings and must accept the responsibility)
31:Elect. Re-levell. Passive Passive, Active
(If needed re-levelling, this parameter is chosen active and
MLKR1 door bridging card must be used)

32:Evacuation Floor Passive Passive, Active


(If panic input detected, floor that the car will be parked)

C.Door Settings

01:A DoorTypeSetting Floor 00 CarDoor (For each floor, A side door type can be set one by one and
can be set at the same time)
02:B DoorTypeSetting Floor 00 NoDoor (For each floor, B side door type can be set one by one and
can be set at the same time)
03:Door A Limit Type Without Limit With Limit, Without Limit
(Limit type selection of A side door mechanism)
04:Door B Limit Type Without Limit With Limit, Without Limit
(Limit type selection of B side door mechanism)
05:Door A Relay Set MLKABINR RA/RK ML70S RA/RK, MLKABIN-R RA/RK, MLKABIN-R ER2/ER1
(Selection of A side door open/close signals that will be
connected to which relays)
06:Door B Relay Set MLKABIN-R ER2/ER1 ML70S RA/RK, MLKABIN-R RA/RK, MLKABIN-R ER2/ER1
(Selection of B side door open/close signals that will be
connected to which relays)
07:Wait AtFloor Time 5 seconds 1-99 seconds
(At full automatic door systems, stay opened time of
automatic door; at only indoor systems, if the door doesn’t
open after the car stopped, selection the time of the next call)
08:PhotocellBlockT. Passive Passive, 1,2,..99 seconds
(Selection the time of cutting photocell signal and starting the
nudging signal)
09:DoorOpenInsp.Time 180 seconds 10-180 seconds
(When the door stayed open, selection the time of warning)
10:CloseButton Delay 2 seconds Passive, 1,2,..20 seconds
(Delay time of close buton detection)
11:Advanced DoorOpen Passive Passive, Active
12:Dir.-OpenD. Style Passive Passive, Active
(If parameter value is passive, when the direction arrows are
on, the same floor call is not imported. If parameter value is
active, when the direction arrows are on and if the same floor
call is come, the automatic door is opened)

13:Auto.DoorWaitOpen Passive Passive, Active (Puk:000000)


(At full automatic door lifts, selection of waiting the door
opened. This situation is not suitable to En81-1/2 + A3
standards. To do this parameter active, ML70S user must
declear to our firm with writings and must accept the
responsibility)

D.Display Settings

01:FloorDisplay Sets Floor 00 Disp 0 Floor 00-23 Disp 0-19,1A,1b,1c,1d


(Display datas that will be screened on floors are changed)

02:Dir. Arrow Type Type 1 Type 1


Type 2
Type 3
Type 4
(Selection of direction arrow types on MLKAT-D card)
03:Dir.ArrowShiftSp. Normal Normal
Slow
Very Slow
No Shift
Very Fast
Fast
(Selection of direction arrow shift speed on MLKAT-D card)
04:ArticleShiftSpeed Normal Normal
Slow
Very Slow
Very Fast
Fast
(Selection of article shift speed on MLKAT-D card)
05:OUTofSERVICE Apx. No Appendix No Appendix
… (FLOOR =1)
… (FAULT – 2)
(Selection of appendix that will added to (OUT OF
SERVICE) article end on MLKAT-D card)

06:Floor Display Set Passive Passive, Active


E.PrgrammableInputs

(Programmable Inputs Sub Section)

Factory Settings Factory Settings


for Electrical Lifts for Hydraulic Lifts
01:ML70S-EIN1 MLKS10-EXO1 Not Used
02:ML70S-EIN2 MLKS10-EXO2 Not Used
03:ML70S-EIN3 Down Re-levelling Not Used
04:ML70S-EIN4 Up Re-levelling Not Used
05:ML70S-EIN5 Not Used 141 (Fixed)
06:ML70S-EIN6 Fire Fire
07:ML70S-EIN7 Earthquake Earthquake
08:ML70S-EIN8 Not Used Not Used
09:ML70S-EIN9 Not Used Not Used
10:ML70S-EIN10 142 Floor Stopper 142 (Fixed)
11:ML70S-EIN11 M0 Pulse M0 Pulse
12:ML70S-EIN12 M1 Pulse M1 Pulse
13:MLKABIN-R-EIN1 K16 Open Limit-A K16 Open Limit-A
14:MLKABIN-R-EIN2 K19 Close Limit-A K19 Close Limit-A
15:MLKABIN-R-EIN3 Down Re-levelling Not Used
16:MLKABIN-R-EIN4 Up Re-levelling Not Used
17:MLKABIN-R-EIN5 Full Load Full Load
18:MLKABIN-A1-EIN1 Not Used Not Used
19:MLKABIN-A1-EIN2 Not Used Not Used
20:MLKABIN-A2-EIN1 Not Used Not Used
21:MLKABIN-A2-EIN2 Not Used Not Used
22:MLKABIN-B1-EIN1 Not Used Not Used
23:MLKABIN-B2-EIN2 Not Used Not Used
24:MLKABIN-B2-EIN1 Not Used Not Used
25:MLKABIN-B2-EIN2 Not Used Not Used
26..57:MLKATD0..31-A-EIN Not Used Not Used
58..89:MLKATD0..31-B-EIN Not Used Not Used
Assignable Functions

1- MLKS10-EXO1 (MLKS10 communication input 1)


2- MLKS10-EXO2 (MLKS10 communication input 2)
3- Down Re-levelling (Down re-levelling input)
4- Up Re-levelling (Up re-levelling input)
5- Fire (Fire input)
6- Earthquake (Earthquake input)
7- Driver Fault (Inverter fault input at UPS evacuation)
8- Change Direction (Change direction input at UPS evacuation)
9- StarTriangleStart (Star-Triangle starting input)
10- 819 Limit Switch
11- 820 Limit Switch
12- Overload (Overload contact)
13- Full Load (Full load contact)
14- Fireman (Fireman key input)
15- Panic (Panic button input)
16- Vatman (Vatman key input)
17- K16 Open Limit-A (A door open limit input)
18- K19 Close Limit-A (A door close limit input)
19- Open-B (B door open limit input)
20- Close-B (B door close limit input)
21- K16 Open Limit-B (B door open limit input)
22- K19 Close Limit-B (A door close limit input)
23- Photocell-A (A door photocell input)
24- Photocell-B (B door photocell input)
25- M0 Pulse
26- M1 Pulse
27- JF Levelling Sw.
F.Programm. Outputs
(Programmable Outputs Sub Section)
Factory Settings Factory Settings
for Electrical Lifts for Hydraulic Lifts
01:ML70S-RY Re-levellingSpeed Not Assigned
(Motor-Valve Auxiliary Relay)
02:ML70S-RT Inspection Not Assigned
(It can be set (Star-Triangle Relay)
at KS10 rescue)
03:ML70S-RB Ups Contactor Not Assigned
(When ML65X-EIN4 input is selected Star-Triangle start, relay that is
dropped while there is this input)
04:ML70S-RLIR Lirpomp Lirpomp
05:ML70S-OUT1 Gong Gong
06:ML70S-OUT2 Middle Speed 1 Hyd.Re-lev. Motor
07:ML70S-RA Not Used Not Used
08:ML70S-RK Not Used Not Used
09:MLKABIN-R-EO1 Nudging Nudging
10:MLKABIN-R-RA Fixed ! Fixed !
11:MLKABIN-R-RK Fixed ! Fixed !
12:MLKABIN-R-RE1 Fixed ! Fixed !
13:MLKABIN-R-RE2 Fixed ! Fixed !
14:MLKABIN-K-A1-EO1 Gray-Code M0 Gray-Code M0
15:MLKABIN-K-A1-EO2 Gray-Code M1 Gray-Code M1
16:MLKABIN-K-A1-EO3 Gray-Code M2 Gray-Code M2
17:MLKABIN-K-A1-EO4 Gray-Code M3 Gray-Code M3
18:MLKABIN-K-A1-EO5 Overload Overload
19:MLKABIN-K-A1-EO6 Inspection Inspection
20:MLKABIN-K-A1-EO7 Down Arrow Down Arrow
21:MLKABIN-K-A1-EO8 Up Arrow Up Arrow
22..29: MLKABIN-K-A2-EO1..8 Not Used Not Used
29..37: MLKABIN-K-B1-EO1..8 Not Used Not Used
38..45: MLKABIN-K-B2-EO1..8 Not Used Not Used
45..77:MLKAT-D0..31-A-EO Not Used Not Used
78..A9:MLKAT-D0..31-B-EO Not Used Not Used
B0:MLSERI65-GCx Gray-Code Gray-Code

Assignable Functions

1- Inspection
2- Car Lamp
3- Re-levellingSpeed (Re-levelling speed output at electrical lifts)
4- Ups Contactor (UPS-Inverter contactor at UPS rescue)
5- Gong
6- Hyd.Re-lev. Motor (Lower power motor output at re-levelling in hydraulic lifts)
7- Middle Speed (Output when the target floor is the nearest floor at electrical lifts)
8- Gray-Code M0
9- Gray-Code M1
10- Gray-Code M2
11- Gray-Code M3
12- Gray-Code M4
13- Binary M0
14- Binary M1
15- Binary M2
16- Binary M3
17- Binary M4
18- Nudging (At full automatic door lifts, output at the end of photocell blocking time)
19- At Floor Signal
20- Up Arrow
21- Down Arrow
22- Fault (Inverse) (At normal position, there is always output; at fault position, output is cut off)
23- Overload
24- Out Of Service
25- Lirpomp
26- Middle Speed 2
G.Maintenance Sets

01:Next Maintenance 01.01.2013 (Setting of next maintenance date)

02:At Maint.Date End Only Warn Only Warn


Block The Lift
03:Reset Run Number No Yes, No
(After the maintenance, total run is reset)
04:Delete Faults ? No Yes, No

H.Evacuation Sets

01:Evacuation Type Evacuate WithKS10 Evacuate WithKS10


Evacuate With UPS
Gearless WithVVVF
(At gearless machine systems, rescue operation with VVVF
motor control)
GearlessWithBrake
(At gearless machine systems, rescue operation with
openning brake only)
02:Evacuation Delay 5 seconds 1-15 seconds
(After the detection of main power is cut, selection of waiting
time to start the rescue operation)
03:EvacuationMaxTime 40 seconds 10-200 seconds
(Selection of maximum movement time at rescue)

04:Evacu.JF MoveTime Passive Passive, 0,1-10,0 seconds


(At rescue operation, after the detection of JF, selection of
needed time to re-levelling)

I.Shaft Learning

01:Learn Shaft No Yes, No


(If this parameter is chosen “Yes”, shaft learning procedure
is started)
02:Hi.SpeedSlowDist. 120 cm 10-500 cm
(Starting distance selection of passing from the high speed to
slow speed to the exact floor)
03:Mid.Spd.SlowDist. 80 cm 10-500 cm
(Starting distance selection of passing from the high speed to
slow speed when going to the nearest floor at high speed
lifts)
04:LowSpeedStopDist. 70 mm 1-200 mm
(While approaching to the target floor, selection of cutting
distance of low speed signal)
05:Dist.ToMidd.Speed 60 cm 1-500 cm
(To give the high speed signal, selection of the nearest floor
minimum distance)
06:Reader Lenght 30 cm
07:817 Position Between 0-1 Floor Between 0-1 Floor
Between 1-2 Floor
(Selection position of 817 lower limit switch)
08:Up Level Correct Floor 01 00mm Floor 01-31, For All -99, 0, 99mm
(Selection of precision levelling adjustment for each floor on
up direction)
09:DownLevel Correct Floor 00 00mm Floor 00-30, For All -99, 0, 99mm
(Selection of precision levelling adjustment for each floor on
down direction)
10:Floor Heights Floor 00= 0mm Floor 00-15, -99, 0, 99mm
(After the shaft learning, tracing the floor heights that
measured)
11:CalculateDistance Passive Passive, Active
(For explanation, please look user manual)
12:SlowingDistance3 50 cm 50-200 cm
(For explanation, please look user manual)
13:Correction Mode Passive Floor 00-15, -99, 0, 99mm
(For explanation, please look user manual)
J.General Settings

01:Factory Sets ? No Yes, No


(All parameter values are changed into factory settings)
02:Clock Setting 00:00 (Setting the clock)
03:Date Setting 01.01.2013 (Setting the date)
04:Auto Tuning No Yes, No
(If this parameter selected YES, at UP and DOWN direction
first movement in inspection mode, OSG/Brake Control input
is not watched during 180 seconds.)
05:DeleteMLKR1Error? No Yes, No
(Stored faults info is deleted about MLKR1 card)
06:Delete UCM Error? No Yes, No
(Stored faults info as a result of UCM is deleted)
07:UCM Up Test No Yes, No
08:UCM Down Test No Yes, No
09:ResetTotalRunNum. No Yes, No
10:Change Password 0000 (Changing password)
11:Cancel Password ? No Yes, No
(Password is cancelled, new value is 0000)
12:SaveToDatakey No Yes, No
13:Read Datakey No Yes, No
99:Version 1.01.00/01.01.2013

K.Gong Settings

01:Car Gong Passive Passive, Active


(Selection of gong outputs on top of the car card passive or
active)

02:Floor Card Gongs Passive Passive, Active


(Selection of gong outputs on floor card passive or active)

03:Gong Type Single Sound Single Sound (Single sound on up and down direction)
Double Sound (Double sound on up and down direction)
UpSingle,DownDbl. (Up direction single sound, down
direction double sound)
UpDbl.,DownSingle (Up direction double sound, down
direction single sound)
(Selection of gong type on floor cards)

04:Gong Ringing Time When Car Stopped When Car Stopped


(Gong signal when the car stopped)
While Car Slowing
(Gong signal when the car is slowing for the next floor)