Next PG2 Next K9 PG2 English Installer Guide D-302413
Next PG2 Next K9 PG2 English Installer Guide D-302413
Next PG2 Next K9 PG2 English Installer Guide D-302413
Installation Instructions
NEXT K9-
K9-85 PG2
PowerG, Wireless, PIR /Pet Tolerant Motion Detector
1. INTRODUCTION
The Next PG2 and Next K9-85 PG2 are 2-way, microprocessor-controlled, wireless digital PIR detectors.
The detectors features are as follows: A
• For use with all PowerMaster® control panels (version 10 and higher).
• Combined Fresnel and cylindrical optics, up to 15 meters (49 ft).
• The Next PG2 includes wall creep zone protection.
• In Next PG2 and Next K9-85 PG2, Target Specific Imaging™ (TSI) technology is used for distinction B
between human beings and pets weighing up to 38 kg (85lb).
• Includes a fully supervised PowerG transceiver.
• The advanced True Motion Recognition™ algorithm (patented) allows distinguishing between the true A. LED
motion of an intruder and any other disturbances which may cause false alarms. B. Lens
• Sophisticated frequency domain digital signal processing. Figure 1: External View
• Built-in link quality indicators; no need for the installer to physically approach the control panel thus making
installation faster and easier.
• No vertical adjustment is needed.
• Motion event counter determines whether 1 or 2 consecutive motion events will trigger an alarm.
• Automatic termination of walk-test after 15 minutes.
• Microprocessor-controlled temperature compensation.
• Sealed chamber protects the optical system.
• Front cover and back tamper switches, for improved tamper protection.
• White light protection.
• Notes: 1. The pet immunity feature was not evaluated by UL.
2. For CE installations, the pet immunity was not evaluated by DNV.
3. The pet immunity feature is not evaluated and certified by Applica Test & Certification AS.
2. INSTALLATION
2.1 General Guidance (see Fig. 2)
1. Keep away from heat sources. 1 2 3
2. Do not expose to air drafts.
3. Do not install outdoors.
4. Avoid direct sunshine.
5. Keep wiring away from power cables. 4 5 6
Important! The Next K9-85 PG2 detector is tolerant to 38 kg (85 lb) animals moving on the floor or climbing on
furniture as long as the activity takes place below 1 m (3 ft). Above the 1 m (3 ft) height limit, the detector is tolerant
to 19 kg (42 lb) pets, but the pet immunity will decrease as the pet gets closer to the detector. It is therefore
recommended to select a mounting location that minimizes potential close proximity of animals.
WARNING! To comply with FCC and IC RF exposure compliance requirements, the PIR detector should be located at a distance of at least 20
cm from all persons during normal operation. The antennas used for this product must not be co-located or operated in conjunction with any other
antenna or transmitter
2 4
3
A
1 C D
Notes:
[1] If the detector is already enrolled you can configure the detector parameters via the “Modify Devices” option – see Step 2.
[2] Select the "Device Settings" option and refer to section 2.4 to configure the detector parameters.
Event Counter Here you determine whether an alarm will be activated upon continued motion (low sensitivity) or upon a single
alarm event (high sensitivity)..
Optional settings: LOW sensitive (default) and HIGH sensitive.
•
•
DISARM Activity Here you determine whether or not to set the activity time during disarm.
Optional settings: NOT Active (default), YES – no delay, YES + 5s delay, YES + 15s delay, YES + 30s delay,
YES + 1m delay, YES + 2m delay, YES + 5m delay, YES + 10m delay, YES + 20m delay and YES + 60m
delay.
•
•
1
2
4. SPECIAL COMMENTS
Even the most sophisticated detectors can sometimes be defeated or may fail to warn due to: DC power failure / improper connection,
malicious masking of the lens, tampering with the optical system, decreased sensitivity in ambient temperatures close to that of the human
body and unexpected failure of a component part.
The above list includes the most common reasons for failure to detect intrusion, but is by no means comprehensive. It is therefore
recommended that the detector and the entire alarm system be checked weekly, to ensure proper performance.
An alarm system should not be regarded as a substitute for insurance. Home and property owners or renters should be prudent enough
to continue insuring their lives and property, even though they are protected by an alarm system.
Visonic Ltd.
M/N: RFD
FCC ID: WP3RFD
IC: 1467-RFD
This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful interference in residential installations. This equipment generates uses
and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to
radio and television reception.
However, there is no guarantee that interference will not occur in a particular installation. If this device does cause such interference, which can
be verified by turning the device off and on, the user is encouraged to eliminate the interference by one or more of the following measures:
– Re-orient or re-locate the receiving antenna.
– Increase the distance between the device and the receiver.
– Connect the device to an outlet on a circuit different from the one that supplies power to the receiver.
– Consult the dealer or an experienced radio/TV technician.
APPENDIX: SPECIFICATIONS
GENERAL 10m
32.8ft
Detector Type Dual element low-noise pyroelectric sensor
90°
Lens Data No. of Curtain Beams / curtains:
Next PG2: 18 far, 18 mid, 10 close. A 5m
16.4ft
Next K9-85 PG2: 18 far, 18 mid, 18 close
Note: Lens – Reflex II PIR, Fresnel type lens With Optical attenuation in the 0
lower part of the lens. Lens material is High Density Polyethylene (HDPE). Part
of Enclosure Cover (Item 1) and snapped to the Enclosure Base (Item 2) by two
5m
tabs and one screw. 16.4ft
Max. Coverage 15 x 15 m, (49 x 49 ft) / 90°
10m
A. HORIZONTAL VIEW 32.8ft
B. VERTICAL VIEW 0 5 10 15 m
16.4 32.8 49.2 ft
C. Next PG2: 0.5-4m, Next K9-85 PG2: 2-4m 2.1 m
Pet Immunity (Next K9-85 PG2 Up to 38 kg (85 lb)
B (6.9 ft)
only) 0
C 5
16.4
10
32.8
15 m
49.2 ft
ELECTRICAL
Fig. 5. Coverage Pattern & Walk-test
Power Supply Type C
Notes:
1. Use only the above battery type.
2. For UL installations use Gold Peak (GP) CR123A only.
Nominal Battery Capacity 1450 mA/h
Battery Life (for typical use) 6 to 8 years
Low Battery Threshold 2.5 V
FUNCTIONAL
True Motion Event Verification 2 remote selections at panel - LOW, HIGH
Alarm Period 2 seconds
WIRELESS
Frequency Band (MHz) Europe and rest of world: 433-434, 868-869 USA: 912-919
Communication Protocol PowerG
Supervision Signaling at 4-min. intervals
Tamper Alert Reported when a tamper event occurs and in any subsequent message, until the tamper switch is restored
MOUNTING
Height 1.8 - 2.4 m (6 - 8 ft). For Next PG2, the recommended height is up to 2.1 m (7 ft)
Installation Options Surface or corner
ACCESSORIES BR-1: Surface mounted swivel bracket, adjustable 30° down and 45° left/45° right.
BR-2: BR-1 with a corner adapter
BR-3: BR-1 with a ceiling adapter
Note: UL did not evaluate the product with the use of the BR brackets
ENVIRONMENTAL
RFI Protection >20 V/m up to 2000 MHz, excluding inband frequencies
Operating Temperatures -10°C to 50°C (14°F to 122°F) indoor
Note: UL tested 0°C to 49°C
Storage Temperatures -20°C to 60°C (-4°F to 140°F)
Humidity Average relative humidity of up to approximately 75% non-condensing. For 30 days per year the relative humidity may vary
between 85 % and 95 % non-condensing
Note: For UL installations, relative humidity is 85%.
PHYSICAL
Size (H x W x D) 94.5 x 63.5 x 53.0 mm (3-11/16 x 2-1/2 x 2-1/16”)
Weight (with battery) 70 g (2.5 oz).
Color White
EMAIL: [email protected]
INTERNET: www.visonic.com
VISONIC LTD. 2015 D-302413 NEXT PG2, NEXT K9-85 PG2 (REV. 7, 6/15) Please see separate Warranty statement