WLB32 Industrial LED Light Bar (AC) : Datasheet

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

WLB32 Industrial LED Light Bar (AC)

Datasheet
Banner’s WLB32 is an ultra-bright LED fixture that features an even light
output for a no glare ‘glow’. Suitable for a variety of environments and
applications, including work stations, machine lighting, control cabinets,
and manufacturing lines, the WLB32 uses advanced LED lighting
technology to provide a high-quality and maintenance free industrial
lighting solution for years.
• Highly energy efficient for overall cost savings
• High/Low/Off switch
• Models with eye shield block side glare
• Daisy chain power to multiple lights
• Motion detection models available
• Metal housing, shatterproof window
• Easy installation with snap clips, or a choice of magnetic or
Model without angle brackets
Motion Detector WLB32 Industrial LED Light Bars are available as cascadable models
Model with Model with Eye that can be "daisy-chained" together for a continuous length of lighting,
Motion Detector Shield and with a minimum of wiring. Each light bar can be turned to high, low, or
Motion Detector off independently of the other lights, upstream or downstream, in the
chain. A double-ended accessory cordset must be used between each
pair of cascading lights.

90 to 264 V ac Models

Models Lighted Length (mm) Connector Lumens


WLB32ZC285PBQMB 285 750
WLB32ZC570PBQMB 570 1500
Custom Quick Disconnect
WLB32ZC850PBQMB 850 2250
WLB32ZC1130PBQMB 1130 3000

The listed models include a U.S. power cable.


• To order model with no power cable, omit the suffix "B" from the model number. For example, WLB32ZC285PBQM. For a
list of other countries' wall plug cables, refer to the Accessories list.
• To order the light without the integral switch, omit the "PB" from the model number. For example, WLB32ZC285QMB.
• To order the light with the integral motion detector, replace the 'PB' from the model number with 'M'. For example,
WLB32ZC285MQMB.
• To order the light with the eye shield, add an 'E' after the length. For example, WLB32ZC285EPBQMB.

Important: Read the following instructions before operating the light. Please download the complete WLB32
Industrial LED Light Bar (AC) technical documentation, available in multiple languages, from
www.bannerengineering.com for details on the proper use, applications, Warnings, and installation instructions
of this device.

Important: Lea el siguiente instructivo antes de operar el luminario. Por favor descargue desde
www.bannerengineering.com toda la documentación técnica de los WLB32 Industrial LED Light Bar (AC),
disponibles en múltiples idiomas, para detalles del uso adecuado, aplicaciones, advertencias, y las
instrucciones de instalación de estos dispositivos.

Important: Lisez les instructions suivantes avant d'utiliser le luminaire. Veuillez télécharger la documentation
technique complète des WLB32 Industrial LED Light Bar (AC) sur notre site www.bannerengineering.com pour
les détails sur leur utilisation correcte, les applications, les notes de sécurité et les instructions de montage.

Original Document 3 December 2019


176314 Rev. K
176314
WLB32 Industrial LED Light Bar (AC)

Installing the WLB32 AC Series Lights

Figure 1. Attaching the Snap Brackets (Step 1) Figure 2. Installing the Cascade Cover (Step 8)

1. Attach the snap brackets to the light.


2. Select a suitable horizontal or vertical dry mounting location.
3. Place the light in the mounting location and mark the positions of the snap bracket mounting holes.
4. Drill the holes and use appropriate screws to secure the snap bracket to the mounting location.
5. Snap the light onto the brackets.
6. When daisy chaining multiple lights, follow steps 1 through 5 to mount additional lights. See the application note in the
Specifications for the maximum allowed lights daisy chained together and maximum allowed cable run when choosing
mounting locations.
7. Connect the daisy chained units together using cascade cordsets (see Accessories).
8. Install the supplied cascade cover over the output connector on the last light in the chain.
9. Plug the power cord from the first light into the wall outlet.

CAUTION: To reduce the risk of fire, electric shock, or injury to personnel:


• Use only insulated staples or plastic ties to secure cords;
• Route and secure cords so that they will not be pinched or damaged when the cabinet is pushed to the
wall;
• Position the portable cabinet light with respect to the cabinet so the lamp replacement markings are
able to be read during relamping;
• Do not recess into ceilings or soffits; and
• Do not conceal the cords. The National Electrical Code (NEC) does not permit cords to be concealed
where damage to insulation may go unnoticed. To prevent fire danger, do not run cord behind walls,
ceilings, soffits, or cabinets where it may be inaccessible for examination. Cords should be visually
examined periodically and immediately replaced when any damage is noted.

Specifications
Operating Voltage
90 to 264 V ac (50 or 60 Hz)
Power factor > 0.95 on high setting at 120 V ac
See electrical characteristics on product label
Supply Current

Light Length (mm) Max Current Draw (A) at 90 V ac Typical Current Draw (A)

120 V ac 230 V ac

285 0.125 0.075 0.045


570 0.250 0.150 0.080
850 0.375 0.225 0.115
1130 0.500 0.300 0.150

2 www.bannerengineering.com - Tel: + 1 888 373 6767 P/N 176314 Rev. K


WLB32 Industrial LED Light Bar (AC)

Supply Protection Circuitry Mounting


Protected against transient voltages Snap clips; optional magnetic mount or swivel bracket accessories
available
Light Characteristics
Color: Daylight white Connections
Color temperature (CCT): 5000K (±300K) Integral custom QD (connecting cordset required)
Lumen output: 750 (±5%) per foot, typical at 25 °C (77 °F) Environmental Rating
CRI: 85 typical
IEC IP50
Eye shield reduces lumens by approximately 25%
Vibration and Mechanical Shock
LED Lifetime
Vibration 10-55 Hz 1.0 mm p-p amplitude per IEC60068-2-6
Lumen Maintenance - L70
Shock 15G 11 ms duration, half sine wave per IEC60068-2-27
When operating within specifications, output will decrease less than
30% after 50,000 hours. Operating Temperature
Push Button –25 °C to +45 °C (–13 °F to 113 °F)
II = 100% light intensity Models with Motion Detection: –20 °C to +45 °C (–4 °F to +113 °F)
I = 50% light intensity Storage Temperature
O = Standby –40 °C to +70 °C (–40 °F to +158 °F)
Models with Motion Detection Test Data
Light turns off after approximately 60 seconds without detecting LM-79, LM-80, TM-21
motion.
Range: 12 m; ±45° field of view Application Note
Standby current: 170 µA When connecting cascadable lights in series, do not exceed the
maximum unit limit of 10, regardless of light size, and do not
Construction exceed a maximum wiring distance of 100 m (328 ft)
Anodized aluminum housing; polycarbonate window and end caps;
stainless steel mounting brackets Certifications

Spacing Criterion
Vertical: 1.22
Horizontal: 1.32 E476617

UL Listed UL Recognized
only for for easy
120 V ac, installation in
60 Hz control cabinets

Spacing Criteria (SC)


The spacing criteria is the fixture-spacing-to-mounting-height ratio and aids in laying out a pattern of fixtures. Multiply the spacing
criteria by the mounting height to get the maximum fixture spacing that still provides even illumination (no shadowing between
fixtures).
Luminaire Spacing = SC × Height to Illuminated Plane
The mounting height is the distance from the fixture to the surface you are lighting.

Light Characteristics
Illuminance at a Distance Isolux Pattern Polar Candela Distribution
2 1 0m 1 2
2
180° 170°
Center Beam (lux) Beam Width (m) 230 160°
150°
192 140°
3682 lux 0.4 m 0.7 m
0.17 m 153 130°
1979 lux 0.8 m 1.4 m 1 120°
0.33 m 115
825 lux 1.2 m 2.1 m 110°
0.50 m 77
439 lux 1.6 m 2.8 m
(candela)

38 100°
0.67 m
345 lux 2.0 m 3.5 m
CD

0m 0 90°
0.83 m
223 lux 2.4 m 4.2 m 38 80°
1.00 m
77 70°
Vert. Horiz.
115 60°
Vertical Spread: 101.5° 1 153 50°
Horizontal Spread: 128.8° 192 40°
30°
230 20°
Vertical Angle: 0° 10°
2
Mount height of 1 meter (1 m) 0° Vertical 90° Horizontal

150 lux 75 lux 10 lux


125 lux 50 lux 5 lux
100 lux 25 lux 50% max.
candela

Figure 3. 285 mm Models

P/N 176314 Rev. K www.bannerengineering.com - Tel: + 1 888 373 6767 3


WLB32 Industrial LED Light Bar (AC)

Illuminance at a Distance Isolux Pattern Polar Candela Distribution


2 1 0m 1 2
2
180° 170°
Center Beam (lux) Beam Width (m) 460 160°
150°
4721 lux 0.4 m 0.7 m 383 140°
0.17 m 307 130°
2937 lux 0.8 m 1.4 m 1 120°
0.33 m 230
1359 lux 1.2 m 2.1 m 110°
0.50 m 153
785 lux 1.6 m 2.7 m

(candela)
77 100°
0.67 m
621 lux 2.0 m 3.4 m

CD
0m 0 90°
0.83 m
451 lux 2.4 m 4.1 m 77 80°
1.00 m
153 70°
Vert. Horiz.
230 60°
Vertical Spread: 101.5° 1 307 50°
Horizontal Spread: 128.2°
383 40°
30°
460 20°
Vertical Angle: 0° 10°
2
Mount height of 1 meter (1 m) 0° Vertical 90° Horizontal

300 lux 150 lux 25 lux


250 lux 100 lux 10 lux
200 lux 50 lux 50% max.
candela

Figure 4. 570 mm Models

Illuminance at a Distance Isolux Pattern Polar Candela Distribution


2 1 0m 1 2
2
180° 170°
Center Beam (lux) Beam Width (m) 650 160°
150°
5371 lux 0.4 m 0.7 m 542 140°
0.17 m 433 130°
3470 lux 0.8 m 1.4 m 1 120°
0.33 m 325
1831 lux 1.3 m 2.1 m 110°
0.50 m 217
1103 lux 1.7 m 2.9 m

(candela)
108 100°
0.67 m
899 lux 2.1 m 3.6 m

CD
0m 0 90°
0.83 m
647 lux 2.5 m 4.3 m 108 80°
1.00 m
217 70°
Vert. Horiz.
325 60°
Vertical Spread: 102.7° 1 433 50°
Horizontal Spread: 130.1°
542 40°
30°
650 20°
Vertical Angle: 0° 10°
2
Mount height of 1 meter (1 m) 0° Vertical 90° Horizontal

450 lux 225 lux 25 lux


375 lux 150 lux 10 lux Illuminance at a Distance
300 lux 75 lux 50% max.
candela

Figure 5. 850 mm Models

Illuminance at a Distance Isolux Pattern Polar Candela Distribution


2 1 0m 1 2
2
180° 170°
Center Beam (lux) Beam Width (m) 870 160°
150°
5371 lux 0.4 m 0.7 m 725 140°
0.17 m 580 130°
3639 lux 0.8 m 1.4 m 1 120°
0.33 m 435
2008 lux 1.3 m 2.1 m 110°
0.50 m 290
1274 lux 1.7 m 2.9 m
(candela)

145 100°
0.67 m
1065 lux 2.1 m 3.6 m
CD

0m 0 90°
0.83 m
869 lux 2.5 m 4.3 m 145 80°
1.00 m
290 70°
Vert. Horiz.
435 60°
Vertical Spread: 103.3° 1 580 50°
Horizontal Spread: 129.7°
725 40°
30°
870 20°
Vertical Angle: 0° 10°
2
Mount height of 1 meter (1 m) 0° Vertical 90° Horizontal

600 lux 300 lux 50 lux


500 lux 200 lux 25 lux
400 lux 100 lux 50% max.
candela

Figure 6. 1130 mm Models

4 www.bannerengineering.com - Tel: + 1 888 373 6767 P/N 176314 Rev. K


WLB32 Industrial LED Light Bar (AC)

Illuminance at a Distance Isolux Pattern Polar Candela Distribution


2 1 0m 1 2
2
180° 170°
Center Beam (lux) Beam Width (m) 250 160°
150°
3654 lux 0.4 m 0.4 m 208 140°
0.17 m 167 130°
2024 lux 0.8 m 0.8 m 1 120°
0.33 m 125
813 lux 1.2 m 1.3 m 110°
0.50 m 83
442 lux 1.6 m 1.7 m

(candela)
42 100°
0.67 m
345 lux 2.0 m 2.1 m

CD
0m 0 90°
0.83 m
250 lux 2.3 m 2.5 m 42 80°
1.00 m
83 70°
Vert. Horiz.
125 60°
Vertical Spread: 98.7° 1 167 50°
Horizontal Spread: 102.8°
208 40°
30°
250 20°
Vertical Angle: 0° 10°
2
Mount height of 1 meter (1 m) 0° Vertical 90° Horizontal

150 lux 75 lux 10 lux


125 lux 50 lux 5 lux
100 lux 25 lux 50% max.
candela

Figure 7. 285 mm Models with Eye Shields

Illuminance at a Distance Isolux Pattern Polar Candela Distribution


2 1 0m 1 2
2
180° 170°
Center Beam (lux) Beam Width (m) 500 160°
150°
5334 lux 0.3 m 0.4 m 417 140°
0.17 m 333 130°
3313 lux 0.6 m 0.8 m 1 120°
0.33 m 250
1595 lux 0.9 m 1.1 m 110°
0.50 m 167
884 lux 1.2 m 1.5 m

(candela)
83 100°
0.67 m
706 lux 1.5 m 1.9 m

CD
0m 0 90°
0.83 m
484 lux 1.8 m 2.3 m 83 80°
1.00 m
167 70°
Vert. Horiz.
250 60°
Vertical Spread: 83.5° 1 333 50°
Horizontal Spread: 97.0°
417 40°
30°
500 20°
Vertical Angle: 0° 10°
2
Mount height of 1 meter (1 m) 0° Vertical 90° Horizontal

300 lux 150 lux 25 lux


250 lux 100 lux 10 lux
200 lux 50 lux 50% max.
candela

Figure 8. 570 mm Models with Eye Shields

Illuminance at a Distance Isolux Pattern Polar Candela Distribution


2 1 0m 1 2
2
180° 170°
Center Beam (lux) Beam Width (m) 630 160°
150°
5533 lux 0.3 m 0.5 m 525 140°
0.17 m 420 130°
3460 lux 0.6 m 1.0 m 1 120°
0.33 m 315
1815 lux 0.9 m 1.6 m 110°
0.50 m 210
1096 lux 1.2 m 2.1 m
(candela)

105 100°
0.67 m
896 lux 1.4 m 2.6 m
CD

0m 0 90°
0.83 m
623 lux 1.7 m 3.1 m 105 80°
1.00 m
210 70°
Vert. Horiz.
315 60°
Vertical Spread: 81.4° 1 420 50°
Horizontal Spread: 114.2°
525 40°
30°
630 20°
Vertical Angle: 0° 10°
2
Mount height of 1 meter (1 m) 0° Vertical 90° Horizontal

450 lux 225 lux 25 lux


375 lux 150 lux 10 lux
300 lux 75 lux 50% max.
candela

Figure 9. 850 mm Models with Eye Shields

P/N 176314 Rev. K www.bannerengineering.com - Tel: + 1 888 373 6767 5


WLB32 Industrial LED Light Bar (AC)

Illuminance at a Distance Isolux Pattern Polar Candela Distribution


2 1 0m 1 2
2
180° 170°
Center Beam (lux) Beam Width (m) 820 160°
150°
5733 lux 0.3 m 0.6 m 683 140°
0.17 m 547 130°
3904 lux 0.6 m 1.3 m 1 120°
0.33 m 410
2203 lux 0.9 m 1.9 m 110°
0.50 m 273
1390 lux 1.2 m 2.6 m

(candela)
137 100°
0.67 m
1139 lux 1.5 m 3.2 m

CD
0m 0 90°
0.83 m
806 lux 1.8 m 3.8 m 137 80°
1.00 m
273 70°
Vert. Horiz.
410 60°
Vertical Spread: 83.8° 1 547 50°
Horizontal Spread: 124.8°
683 40°
30°
820 20°
Vertical Angle: 0° 10°
2
Mount height of 1 meter (1 m) 0° Vertical 90° Horizontal

600 lux 300 lux 50 lux


500 lux 200 lux 25 lux
400 lux 100 lux 50% max.
candela

Figure 10. 1130 mm Models with Eye Shields

Dimensions

L1

Motion Detector and/or Eye Shield Models

L2

Specific to models with shield

Model Models without Motion Detector Models with Motion Detector and/or Eye Shield

L1 L2
WLB32ZC285..QM 298 mm (11.7 in) 368 mm (14.5 in)
WLB32ZC570..QM 580 mm (22.8 in) 650 mm (25.6 in)
WLB32ZC850..QM 862 mm (33.9 in) 932 mm (36.7 in)
WLB32ZC1130..QM 1144 mm (45.0 in) 1214 mm (47.8 in)

6 www.bannerengineering.com - Tel: + 1 888 373 6767 P/N 176314 Rev. K


WLB32 Industrial LED Light Bar (AC)

Accessories
Wall Plug Cordsets

Model Plug Type Countries Wire Gauge Length Dimensions

LQMAC-306 Flying Leads


United States, Canada,
LQMAC-306B NEMA 5-15 grounded (IEC Type B)
Japan, Puerto Rico, Taiwan
LQMAC-306D BS 546 (IEC Type D) India
Germany, France, South
LQMAC-306EF CEE 7/7 (IEC Type E or F) Korea, The Netherlands,
1.8 m (6 ft)
38
Poland, Spain, Turkey
18 AWG
LQMAC-306G BS 1363 (IEC Type G)
United Kingdom, Ireland, 10
Singapore, Vietnam
China, Australia, New
LQMAC-306I AS/NZS 3112 (IEC Type I)
Zealand 18
LQMAC-306N NBR 14136 (IEC Type N) Brazil
United States, Canada,
LQMAC-310B NEMA 5-15 grounded (IEC Type B) 3 m (10 ft)
Japan, Puerto Rico, Taiwan

Continuous Run/Cascade Cordsets

Model Length Style Wire Gauge Dimensions

LQMAEC-3005SS 0.15 m (0.5 ft)


LQMAEC-301SS 0.31 m (1 ft)
38
LQMAEC-303SS 0.91 m (3 ft)
LQMAEC-306SS 1.83 m (6 ft) Male straight/Male straight 18 AWG
10
LQMAEC-312SS 3.66 m (12 ft) 14
38
LQMAEC-320SS 6.1 m (20 ft)
18
LQMAEC-330SS 9.14 m (30 ft) 14

Enclosure Accessories

LMBEDS Switch
• Bracket with plunger switch to power lights when the enclosure is opened
• Refer to datasheet 160672 for more information

Mounting Brackets

LMBWLB32 LMBWLB32-180S
20 12 20
• Replaces the bracket that ships with the • Swivel bracket kit allows 180° of 42
WLB32 light movement
• Stainless steel
• Includes 4 snap clips, 4 screws, and 2 36 36
insulator caps 2X Ø6.5
Ø6.4

P/N 176314 Rev. K www.bannerengineering.com - Tel: + 1 888 373 6767 7


WLB32 Industrial LED Light Bar (AC)

Mounting Brackets

LMBWLB32MAG LMBWLB32U
20 19
• Magnetic mounting bracket for easy • Die cast bracket for rugged applications 41
attachment to steel and iron surfaces • Secured to light with included thumb
screw 18
36 • Clearance hole for 6 mm (1/4 in) button
head screw 20
Ø36

LMBWLB32UT
• Die cast bracket for rugged applications 41
• Secured to light with included thumb
screw 18
• Integral 1/4-20 stud for mounting
20
27

Banner Engineering Corp. Limited Warranty


Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or
replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not
cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO
BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES
RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT,
STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously
manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the
product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will
void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at
any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to:
www.bannerengineering.com.
For patent information, see www.bannerengineering.com/patents.

FCC Part 15 and CAN ICES-3 (B)/NMB-3(B)


This device complies with part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). These limits are
designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the manufacturer.

Mexican Importer
Banner Engineering de Mèxico, S. de R.L. de C.V.
David Alfaro Siqueiros 103 Piso 2 Valle oriente
San Pedro Garza Garcia Nuevo Leòn, C. P. 66269
81 8363.2714

© Banner Engineering Corp. All rights reserved

You might also like