0% found this document useful (0 votes)
133 views18 pages

mDACS USB-IO User Manual v160

The document provides instructions for using the mDACS software and USB-IO dongle to connect a computer to the RRC3 altimeter and RTx/GPS system to retrieve flight data, update settings, and perform diagnostics. Key steps include installing the USB-IO driver, downloading and running the mDACS application, selecting the correct COM port in the application preferences, and initiating a "Host Mode" connection to upload/download data and settings from the RRC3 and RTx units. The document outlines the various tabs and functions within the mDACS interface.

Uploaded by

Santiago
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
133 views18 pages

mDACS USB-IO User Manual v160

The document provides instructions for using the mDACS software and USB-IO dongle to connect a computer to the RRC3 altimeter and RTx/GPS system to retrieve flight data, update settings, and perform diagnostics. Key steps include installing the USB-IO driver, downloading and running the mDACS application, selecting the correct COM port in the application preferences, and initiating a "Host Mode" connection to upload/download data and settings from the RRC3 and RTx units. The document outlines the various tabs and functions within the mDACS interface.

Uploaded by

Santiago
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 18

 

mDACS/USB‐IO/BTMM User Manual


For use with the RRC3 Altimeter and RTx/GPS System

Revision 1.60 

Missile Works Corporation


PO Box 1725, Lyons CO 80540
www.missileworks.com


 
Revision History 
Rev 1.02 – Original Release with the RRC3 Altimeter. 
Rev 1.60 – Revised for use with RTx/GPS Telematics System, v1.60 RRC3/mDACS updates, and BTMM usage.  

mDACS and the USB‐IO  
The RRC3 altimeter was developed in conjunction with the mDACS (Missile Works Data Acquisition and Configuration 
Software) to provide the Advanced Flyer with the detailed dynamic data captured during your rocket flights.  The Data 
items captured during your RRC3 flight are: 

● 20 Hz Pressure Data 

● 1 Hz Altimeter Temperature 

● 1 Hz Battery Voltage  

● Drogue, Main, and Auxiliary Events 

Using the 20 Hz pressure RRC3 data, mDACS calculates the corresponding rocket altitude and rocket displacement velocity 
for graphing purposes.  The RRC3 keeps the last 15 flights in its onboard memory, and thereafter writes over the oldest 
flight.  You can fly all day and collect data, then upload and save each flight to your Windows PC after the launch.  Each 
flight records up to a maximum of just over 28 minutes.   

The RTx System records up to 7 flights of 68+ minutes of GPS Epoch data files.  This data can be uploaded and exported to 
Google Earth KML file format for import and display.  

Barometric or GPS Flight data is acquired from the RRC3 or RTx/GPS by your Windows PC using the Missile Works USB‐IO 
dongle, or the BTMM Bluetooth Master Module. 

mDACS PC Requirements 
∙ Windows XP, Windows 7 or Windows 8, Windows 10 with .NET 4.0 framework support minimum 
∙ 1024 x 768 pixel minimum recommended display resolution 
∙ USB port  
 
USB‐IO Dongle 
The USB‐IO dongle is pictured below.  You’ll notice that it has 2 status LED for communication activity, a USB cable 
connection, a power slide switch, and the same COM connector used on the RRC3. 

 

 
Installing the USB‐IO Driver  
The USB IO module requires driver support software in order to operate.   

If you have already installed and run the Featherweight FIP software, PerfectFlite DataCap software, or any of the BRB 
tracker support software, you already have the necessary drivers installed for your PC.   

If not, use the following driver installation steps.  Your PC with require an active internet connection. 

Windows Update Installation 
‐ Plug the USB‐IO dongle and USB cable into your computer.  
‐ A “Found New Hardware” dialog box will appear. 
‐ Click this dialog for details. 
 

A dialog  box should similar to the following appear: 

 
Windows Update will automatically locate and install the latest drivers for the FT232R USB UART hardware.  When the 
installation process is complete, you should see a dialog box similar to this: 

Make note of the COM Port Number (the above port example is COM3) 

Manual Driver Installation 
You can download and install the latest FT‐232 drivers or a self‐installing executable from the FTDI page directly: 
(http://www.ftdichip.com/Drivers/VCP.htm).  


 

Installing the mDACS Application Software 
Locate and run the latest mDACS Setup and Installation program from the Missile Works Web Site “Downloads” page 
(http://www.missileworks.com/downloads/).  Download and run the installer directly on your PC, or open and run the 
installer directly in your browser. 

 After you successfully install your mDACS application, you will have a desktop shortcut available to launch the application.  
Double click the shortcut to launch the mDACS app. 

Note: If your PC does not currently have the .NET 4.0 framework support currently installed, the installation program will 
download and install the necessary support.  Click Yes if the installer detects the absence of .NET 4.0 support.  You will need 
to have an internet connection to perform this download and install. 
 

Running mDACS for the first time 

 
The mDACS application is designed to provide a very intuitive and user friendly interface.  All Navigation, and initiation of 
specific mDACS operations are all launched via a single click.   


 
Along the top of the mDACS window, there are 6 Primary Tabs used for navigation, providing access to the following tabbed 
pages:  

RRC3 Viewer       Used to upload, display, and load/save flight data from the RRC3 
RRC3 Simulator     Simulate a flight “virtually” to validate RRC3 performance 
RRC3 Settings        Manage, review, and load/save settings to/from the RRC3 
RRC Diagnostics    Check all operations of the RRC3 (inputs, outputs, baro sensor) 
RTx/GPS Manager    Test, upload, display, and load/save GPS data and settings to the RTx/GPS system 
System Preferences      Setup the mDACS application software to your personal preferences 

Each page also has a “Button Bar” along the left side of the window.  The button operations are specific to each tabbed 
page.  The “Host Connect” and “Host Disconnect” buttons are shared between several pages... these are common 
operations amongst them. 

Along the bottom of the mDACS window is the Status Bar, which displays version data and communication status info. 

The first thing you need to set up in the application is the “COM” port that is assigned to the USB IO dongle you’ll be using 
with the RRC3.  This setting is located on the System Preferences Page.  Be sure your USB‐IO is connected to your PC.   If 
using the BTMM Bluetooth Module, refer to pages 7 & 8 for how to setup the communications properly. 
 

 

 
Click on the Active Comm Port Drop Down box arrow to display the COM ports available.   If you had no drivers previously 
installed, use the same COM port that was assigned during your driver installation process as noted above.  Otherwise, if 
you are already using the PerfectFlite DT2U/DT3U hardware, select the same COM port used in the DataCap software. 

After you have selected the appropriate COM port, your status bar should look like this: 


mDACS System Preferences

The System Preferences items are defined as follows: 
 
Active Comm Port    Establishes the COM port  used to communicate with the RRC3/RTx   
Bluetooth Module    Host or Sim mode communications are done using BTM Bluetooth Module 
 
GPS Data Format    Format of displayed GPS Lat/Lon data in the RTX Data Inspector and Exports 

Altitude Units       
Velocity Unit      These settings control  what units of measure are applied in mDACS 
Temperature Units 
 
GPS Data Format    Set the Lat/Lon, Nav Status, and Time Display format for the RTx/GPS Data 

Default Data  File Folder   Specifies where mDACS reads/writes Settings and Flight Data 
        (defaults to “My Documents”) 
 
Altitude Calculation Method  Use the Standard Atmospheric Model or Geopotential derivations 
        (refer to the “Reference” section for more info on these methods) 
 
Viewer Data Smoothing   Defines the Flight Viewer Altitude/Velocity smoothing operation 

Settings Manager Options  Controls advanced setting visibility and Settings Manager print format 
 
The System Preferences Button Bar provides the following controls: 
Reset App Defaults 
This will restore all the mDACS System Preferences back to defaults, and this will reset the mDACS Windows size and 
position back to original aspects and location. 

Check for Updates 
This utility will check the Missile Works web site for the availability of a newer version of the mDACS application than you 
are currently running.  A working internet connection is required for this.   
 
Connecting mDACS to the RRC3/RTx in Host Mode with USB 
The “Host Mode” connection between mDACS and the RRC3 is the primary means of communication between the unit and 
your PC.  It’s used for all operations except for the “RRC3 Flight Simulator” mode.  Once you have established a Host Mode 
connection to the RRC3, you can upload flight data, download and upload settings, or utilize any of the “Diagnostic Tools” 


 
that are available.  The USB‐IO dongle can also provide logic power to the RRC3 (not the RTx/GPS) in cases where the 
altimeter may not have an existing power source and power switch, or passively when the RRC3 has an external power 
source and switch (when on a sled). 
 
Note: The piezo, pyro outputs, and continuity inputs of the RRC3 require an external battery to operate. 
 
To start a USB Host Mode session using the RRC3 and USB‐IO power source, follow these steps: 

‐ Make all cable connections EXCEPT the blue data cable from the USBIO adapter to the RRC3 
‐ Ensure the USBIO power switch is ON 
‐ Launch the mDACS app, and ensure the USBIO comm port is selected and ready 
‐ Click the Host Connect button in mDACS to start the 20 second connection countdown 
‐ Insert the blue data cable into the RRC3/RTx Comm socket immediately  
‐ RRC3 should boot up and connect up 
 
To start a USB Host Mode session with the RRC3 using an external power source, follow these steps: 

‐ Make all cable connections EXCEPT the blue data cable from the USBIO adapter to the RRC3 
‐ Ensure the USBIO power switch is OFF 
‐ Launch the mDACS app, and ensure the USBIO comm port is selected and ready 
‐ Click the Host Connect button in mDACS to start the 20 second connection countdown 
‐ Power up the RRC3, then insert the blue data cable into the RRC3 Comm socket 
‐ RRC3 should connect up 
 
 When a successful Host Mode connection is made, your Status Bar should look similar to this: 

The mDACS application will attempt to make the Host connection for up to 20 seconds (displaying a countdown timer) 
before it gives up and requires you to intervene.  Here’s what the Connection Failure Dialog looks like: 

Should you fail to establish a Host Mode session, switch off all power sources, double check all your connections, physically 
disconnect and reconnect the USB IO dongle, then restart the connection sequence again as described above. 

Connecting mDACS to the RRC3/RTx in Host Mode with Bluetooth 
The new v1.60 firmware of RRC3 supports the use of the new m3‐BTMM Bluetooth Module to communicate between your 
altimeter unit and your PC (that’s Bluetooth equipped).  You could conceivably install the BTMM module in your rocket and 
perform all mDACS operations wirelessly.  Procedurally, there’s a required sequence of steps you need to perform when 
initially setting up and subsequently using the module.  Follow the ensuing steps in order to take advantage of this wireless 
operation, and note an external battery/power‐source and power switch are required to make this operate. 


 
To Initialize and Define a Bluetooth Connection: 

        ‐ Plug your m3‐BTMM Module into the COMM Connector and power on the RRC3 
        ‐ Navigate to your PC’s “Devices and Printers” control and click “Add a Device” 
        ‐ Your m3‐BTMM should appear as a new device (HC06).  Click on this device to add it (use ID “1234”). 
        ‐ Once added be sure to set the “Serial Port Services” option so the HC06 can be used as a COM Port 
        ‐ Launch mDACS and open the “Preferences” Tab to select the new Bluetooth Com Port that was just assigned. 
        ‐ Once mDACS has initialized and negotiated a Bluetooth Link, the m3‐BTMM module LED will go solid ON. 
        ‐ Finally, click on the Bluetooth Module Check Box to tell mDACS this is a Bluetooth connection. 
        ‐ Close mDACS and finally power off the RRC3 
 
To start a Host Mode session using a Bluetooth Connection, follow these steps: 

‐ Ensure the m3‐BTMM Module is connected into the COMM Connector of the RRC3 (RRC3 OFF). 
‐ Launch the mDACS app, navigate to the Tab Control you want (Flight Viewer, Setting, Diagnostics, etc.) 
‐ Power up the RRC3 to start the Bluetooth broadcast 
‐ Click the Host Connect button in mDACS to start the 20 second connection countdown 
‐ RRC3 should connect up and operate just like a hardwired session 
 
(NOTE:  The RRC3 altimeter requires the v1.60 firmware in order to use the BTMM with mDACS) 

Uploading RRC3 Flight Data to the RRC3 Viewer 
Presuming you have flown the RRC3 (physically or virtually), flight data will be available to upload to the mDACS Flight 
Viewer.  After establishing a Host Mode connection, click on the “RRC3 Data Upload” button.  The mDACS app will query 
the RRC3 for available data, and then display Upload Manager Dialog form. 

 
 
The Data Upload Manager attempts to pre‐select the most recent flight you’ve made, however you can select any available 
flight from memory.  When the flight you want is selected, click the “Upload Flight” button in the dialog.  The dialog will 
then display the message “Data Upload in Progress”, and you should also see a solid RX status LED until all the flight data 
has been acquired from the RRC3.  When this occurs, the dialog briefly displays a message of “Data Upload Complete”, and 
the RX status LED will go out.  The Dialog then displays a final “Generating Graph Data” message, and when the all the 
calculation processes are finally complete, the Data Upload Manager will close.  

 

RRC3 Viewer
The RRC3 Viewer Page is where all Flight Data is presented in a graphical “Line Series” chart for detailed flight analysis and 
evaluation.    
 
At the upper left of the chart is the Legend.  The units of measure for each item in the legend are established by the System 
Preferences settings.  The 3 Flight Events are also depicted here (Drogue, Main, Aux) for reference.  The events are always 
superimposed on the altitude data series  

The primary Y‐scale on left side of the chart is always altitude. All other chart Y‐scales are located on the right hand side of 
the chart.  The bottom X‐scale of the chart is always displayed with a seconds “timestamp” that represent the specific data 
frames captured by the RRC3 during flight. 
 
Along the bottom of the Chart are 3 Control/Info panels.  From left to right they are: 
 
Graph Controls 
This collection of controls allow you to define the specific  data to display in your chart, along with the ability to replot or 
zoom the chart data.  The zoom buttons are a fixed 120%.  The visibility of data items in the chart also controls which data 
items are included in the Flight Data Inspection Window and the Flight Data Export file. 

In addition to the preset zoom buttons provided, you can select a specific region of the chart for close up inspection.  
Position your mouse pointer in the desired chart region, the press the SHIFT key.  The mouse pointer should change to a 
magnifying glass.  Select and highlight the region to zoom by dragging the mouse pointer.  Once highlighted, release the left 
mouse button and the chart will zoom to the bounds of the highlighted region. 
 
Once a zoom has been activated, the chart will display horizontal and vertical slider bars, and the zooming function can also 
be controlled using your mouse wheel as well. 
 
Flight Summary 
This panel contains several pertinent data items derived from Flight Data upload or the Flight File Load from disk.  It also 
displays the name of the currently Flight File (if applicable).  There’s also a “Note” button that provides access to “Flight 
Notes Editor” where you can add additional comments about this specific flight. 

Cursor 
If you click the “Show Cursor” button, the Chart will display a vertical line along the X‐axis along with the corresponding 
timestamp.  You can use this cursor to select a specific point of interest on the chart.  All the data associated with this time 
stamped data frame are displayed in the cursor panel. 
 
 

   


 
The following is an example of a 2‐stage flight made with the RRC3: 
 

 
The Flight Viewer Button Bar provides the following controls: 
 
RRC3 Host Connect 
Establishes a Host Mode connection with the RRC3. 
 
RRC3 Data Upload 
Opens the Flight Data Upload Manager Dialog form, allowing you to upload and graph/save the flight data residing in the 
RRC3 memory 

RRC3 Data Delete 
Opens the Flight Data Deletion Manager Dialog form, allowing you to delete and or all previous flight data residing in the 
RRC3 memory. 

Flight File Save 
Allows you to save the currently displayed Flight Data to file.  This can be what you just uploaded from the RRC3, or a 
previously saved file that you want to load and rename or annotate with comments.  When clicked you’ll see a standard 
Windows “Save Dialog” form.  All RRC3 Flight Flies use the .rff file extension (RRC3 Flight File). 
10 
 
Flight File Load 
Provides the means to load and display a previously saved Flight File (.rff) .  When clicked you’ll see a standard Windows 
“Load Dialog” form.  All flight data is stored in its raw, normalized format, so each file load requires a complete 
regeneration of all the chart data. 

Flight Data Export 
This utility allows you to export the captured Flight Data to a secondary file using a standard Excel .CSV format.  The items 
specifically displayed in the chart are the items that are included in the export.  Time, Altitude and Pressure are always 
exported by default.   

Flight Data Inspect 
This control will open the Flight Data Inspection window in a easily readable row/column format.  The items displayed in 
this window are the items currently shown in the chart.  Time, Altitude and Pressure are always shown by default. 

Flight Log Manager
This utility provides access to the altimeter resident “Flight Log” record that is stored and maintained in the RRC3 memory.  
The primary purpose of the Flight Log data is to support additional data for users that don’t need or don’t want to examine 
the detailed Flight Data obtained by using a PC and the USB‐IO dongle.   
 
The items tracked and saved in the Flight Log provide data from the LAST FLIGHT that goes beyond the “how high” did it go 
question.  In addition there is a small collection of statistical items, that include Total Flights (32767 max), Total Flight Time 
(3276.7 minutes), and Total Ascent Elevation (999,999 ft).  A small collection of Flight Log Data is available to users via the 
DIP Switch/Pushbutton interface, or it is fully accessible via the plug‐in RRC3 LCD Terminal. 

When the Flight Log Manager Form is displayed, click on the “Read Log” button to acquire the Flight Log data.  You can also 
reset the statistical items contained in the Flight Log by clicking on the “Reset Stats” button. 
 
Here’s a sample of the Flight Log Manager Form: 
 

 
11 
 
Host Disconnect 
Terminates the active Host Mode connection session with the RRC3.  The only time you should require the use of this would 
be if you wanted to switch between “Host” and “Sim” connection modes.  If you’re done interacting with the RRC3 using 
mDACS, just shut down the mDACS app. 

RRC3 Settings
The Settings Manager is your portal to reading, writing, saving, and loading of all the settings available in the RRC3.  All of 
the settings and their operations are covered extensively in the RRC3 User Manual, so they won’t be duplicated here.  
 
One can choose to display some, or all of the settings by checking the associated “Show” checkbox in the System 
Preferences.  
 
All the controls on the Settings Manager page are “grayed out” until you load a collection of settings into mDACS.  This can 
be accomplished by loading a settings file from your PC, or by requesting a settings “read” from an RRC3 connected to 
mDACS in Host Mode. 

Here’s a snapshot of the Settings Manager page once loaded with settings data: 
 

12 
 
Note: If you set the Aux Output Controls “OCS” for an operation, you will see a corresponding flow diagram appear in the 
Diagram Group.  Its purpose is to reinforce this OCS Logic Flow visually. 
 
Note: the content of the Flight Telemetry items will change depending on the RRC3 firmware version 

The Settings Manager Button Bar provides the following controls: 
 
RRC3 Host Connect 
Establishes a Host Mode connection with the RRC3. 

RRC3 Setting Read 
Reads all the current settings in the RRC3 memory.. 

RRC3 Setting Write 
Writes all the current settings shown in the Settings Manager to the RRC3 memory. 

Save Settings File 
Writes all the current settings shown in the Settings Manager to a PC “Settings” File.  When clicked you’ll see a standard 
Windows “Save Dialog” form.  All RRC3 Setting Files use the .rsf file extension (RRC3 Settings File). 

Default Settings 
This will override all the current settings shown in the Settings Manager with the default settings used by RRC3.  Note that 
settings are not saved to a file or written to RRC3 memory. 

Print Settings Sheet 
Provides a printed hardcopy of all the settings currently shown in the Settings Manager.  Use this as a reference sheet on 
the field or to validate settings. 

Print Legend Sheet 
This control will open the Legend Sheet Printer Utility.  All the sheets printed here are intended to provide a supplemental 
reference for the setup and programming of all RRC3 settings. 

Host Disconnect 
Terminates the active Host Mode connection session with the RRC3.   


RRC3 Diagnostics
These tools provides a comprehensive means of evaluating the overall performance and operation of the RRC3.  The 
barometric and temperature sensor readings can be checked, and all inputs and outputs to the RRC3 can also be exercised 
and validated. 
 
Some of these tools will require the connection of an external battery to the RRC3 in order to operate and will not function 
if you’re running the RRC3 from the UBS‐IO dongle power.  These tool groups are labeled accordingly, however the specific 
tools requiring a battery are: 

Continuity Monitor ‐ RRC3 battery required for all continuity status. 
Output Controls  ‐ RRC3 battery required for output activation power. 
Voltage Monitor ‐ No battery, no voltage. 

13 
 
All the Diagnostic Tool groups with the exclusion of the “Output Controls” are “Inputs”, and thusly are all processed and 
displayed simultaneously when you run the Manual Monitor  or the Auto Loop Monitor operations on the Diagnostic Tools 
page.  Note that the Auto Loop Monitor runs continuously until you click the Manual Monitor button.   

The Batch Date query provides the means to display the date that the unit was flashed and tested for operations and can 
establish the service life of the RRC3.   

The Output Controls allow you to individually activate each output of the RRC3. 

IMPORTANT:  ALWAYS USE EXTREME CAUTION and ensure that you have NO LIVE PYRO CHARGES attached to RRC3 
when activating this Output test operation.  

Here’s a screenshot of the Diagnostic Tools page: 



RRC3 Flight Simulator 
The Flight Simulator provides a means to fly your altimeter “virtually” on your bench and directly test and observe its 
operation during the course of the simulated flight.  This feature is especially nice to validate the operation of the Aux 
Output when programmed to provide a specific OCS (Output Control Sequence). 

14 
 
In order to run a simulated flight, the RRC3 needs to boot up and establish a “Sim Mode” connection just like a Host Mode 
connection.  Follow the same steps as Host Mode connection, except the only difference is you’ll be using the “Sim 
Connect” button on the Simulator Page.   

The Sim Connect feature is exclusive to the Flight Simulator. 

 
Along the bottom of the page are two panels: 

Simulation Monitor 
The indicators in the Simulation Monitor panel display the real‐time data altitude, velocity and time while the simulation is 
active and in progress.   When the RRC3 has booted up completely and is finally in Launch Detect mode, the Simulation 
Monitor Panel will be enabled. 
 
Simulation Controls 
Operating the Slider Bars allows you to create an Altitude and Velocity profile that will be similar in scope to your 
anticipated flight regime.  Click the “Plot” button at any time to see how your slider settings stack up on the graph.  The 
“POST” checkbox allows you to enable or bypass the RRC3’s POST validation should you not wish to wait for it to complete. 

15 
 
To run a Flight Simulation: 

‐ Boot up the RRC3 and establish a “Sim Mode” connection  
‐ A Dialog form will appear, advising you the RRC3 is “Initializing” (Click OK) 
‐ Both TX and RX LED’s should start to blink repeatedly 
‐ When the RRC3 is in Launch Detect Mode, the “Start Simulation” button and “Monitor” is enabled 
‐ Click on the “Start Simulation” button to Launch 

Once the RRC3 has “landed” in Simulation Mode, the mDACS software will automatically disconnect from the RRC3.  At this 
point, you can reboot the RRC3 into host mode and upload the captured “Simulated” Flight Data into the Flight Viewer. 
 
The Flight Simulator Button Bar provides the following controls: 
 
RRC3 Sim Connect    Establishes a Sim Mode connection with the RRC3. 
Start Simulation     Launches the Simulation Flight when the RRC3 is ready in Launch Detect Mode 
Sim Disconnect      Terminates the active Sim Mode connection session with the RRC3.   

RTx/GPS Manager

 
16 
 
 
The RTx/GPS Manager Button Bar provides the following controls: 
 
RTx  Host Connect 
Establishes a Host Mode connection with the RTx. 

RTX Setting Read 
Reads all the current settings in the RTX memory.. 

RTX Setting Write 
Writes all the current settings shown in the RTx Settings group to the RTX memory. 

Save RTx File 
Writes all GPS data currently loaded into the RTx Data Inspector to a PC data file for permanent storage and recall purposes.  
When clicked, you’ll see a standard Windows “Save Dialog” form.  All RTx files use the .rtx file extension (RTX data file). 

Load RTx File 
Loads a GPS data file (save previously) into the RTx Data Inspector.  When clicked, you’ll see a standard Windows “Open 
Dialog” form.  

Export RTx Data 
When there’s GPS data loaded into the RTx Data Inspector, you can export this data to one of three different export 
formats, specifically Google Earth KML, Excel CSV, or a simple text format.  You can choose to export all data from the 
Inspector grid, or only the highlighted you selected from the Inspector.  To highlight your GPS data, left‐click on the starting 
row chosen for export.  Scroll down to the last data row for export, and SHIFT left‐click your mouse.  All rows in between 
should highlight in blue. 

RTx Diags Read 
This operation will read the battery voltage data and the state of the DIP switches and PROG button to verify that all these 
RTx inputs are operational.   

RTx Batch Date 
Retrieves the Batch Production Date from the RTX.   

RTx Disconnect 
Terminates the active Host Mode connection session with the RTX.   

 
Connecting mDACS to the RTx/GPS in Host Mode
The RTx/GPS system requires more operating current than the USB‐IO Module can provide, thus in order to run the 
RTx/GPS in host mode, you’ll require and external power source and external power switch for the USB‐IO module or the 
BTMM Bluetooth Module.   

Refer to the previous section for RRC3/RTx connections and operations.

17 
 
Product Warranty
Missile Works Corporation has exercised reasonable care in the design and manufacture of this product and warrants the 
original purchaser that the USBIO is free of defects and that it will operate at a satisfactory level of performance for a 
period of one year from the original date of purchase. If the system fails to operate as specified, then return the unit (or 
units) within the warranty period for repair or replacement (at our discretion). The system must be returned by the original 
purchaser, and be free of modification or any other physical damage which renders the system inoperable. Upon repair or
replacement of the unit, Missile Works Corporation will return the unit postage‐paid to the original purchaser.

Product Disclaimer and Limit of Liability


Because the use and application of this equipment are beyond our control, the purchaser or user agrees to hold harmless 
Missile Works Corporation and their agents from any and all claims, demands, actions, debts, liabilities, judgments, costs, 
and attorney fees arising out of, claimed on account of, or in any manner predicated upon loss or damage to property of, or 
injuries to or the death of any and all persons arising out of the use this equipment. Due to the nature of electronic devices, 
and the application and environments for those devices, the possibility of failure can never be totally ruled out. It is the 
responsibility of the purchaser or user of this equipment to properly test and simulate the actual conditions under which 
the device is intended to be used to ensure the highest degree of reliability and success. 

18 
 