En Quick Start Guide ASIMON Configuration Safety Basic Monitor
En Quick Start Guide ASIMON Configuration Safety Basic Monitor
1 Installation ASIMON360
1.2After
1.2 Nachinstallation
erfolgreicher Installationyou
is completed voncan
1.1 Run the command "Install" from
the "ASIMON360" software and follow start commissioning the hardware or
the screen instructions. directly continue with the device
configuration.
3.1 Start ASIMON360 and select "New workspace" 3.2 The hardware configuration opens. Select the 3.3 Set the local inputs and outputs. An E-STOP 3.4 Enable the global error unlock for the slave 1A
and click on "Create". Safety Basic Monitor (BWU2852). is connected to terminals S11/12/21/22. by selecting the "Service" tab, checking the field
"Global error unlock" and selecting address 1-1A.
Confirm with OK.
3.5 Click on "Add Slave" and select the connected 3.6 Use the menu point "Add Slave" to select 3.7 Go to "Safe outputs" and disable the output 3.8 All devices are now added. Now click on
Light Button Module (BW2528) and and use the ASi Safety 4I/2O Module (BWU2314). 2.14. "OK". ASIMON360 creates a basic
"Standard I/Os" to assign a standard input to the Deactivate all safe inputs except for configuration.
lower and upper button. S11/12/21/22. An E-STOP is connected here.
3.9 Global error unlock and error unlock use the 3.10 Drag the device "1-1A Upper button 3.11 Drag the device "1-3 S11/S12/21/22 E-STOP" of 3.12 Start the commissioning wizard to address
same input. Select in the catalog section the standard input." to the Monitored start on the AS-i safety 4E/2A module (BWU2314) into the the slaves and load the configuration into the
device "1-1A Lower button standard input" and OSSD1 and OSSD3. &-device in OSSD1 and into the &-device in OSSD3. Safety Basic Monitor (BWU2852). Connect the
drag it using drag&drop into the restart in OSSD3. Gateway (BWU2852) and follow the steps in the
commissioning wizard.
3.13 Change the interface of the Safety Basic 3.14 After completing the steps of the 3.15 The ASIMON diagnostics becomes visible. 3.16 Push the E-STOP on the ASi Safety 4I/2O-
Monitor as follows (example): commissioning wizard confirm the protocols You can monitor and test your configuration. Module (BWU2314) and release it again. Initiating
IP-Address:192.168.42.3 and click on "Finish". Operating the upper button activates the monitored the monitored start again restarts the OSSDs.
Subnet mask: 255.255.255.0 start and the safe input switches to green. The
Standard gateway: 192.168.42.4 pressed lower button triggers the error unlock and
the restart.