This document provides material specifications and load capacity information for RoofDek D46 profiled steel roof decking. It includes specifications for decking made of 0.7mm, 0.9mm, and 1.2mm steel or aluminium. Charts show the decking's ultimate properties like moment capacity and section properties. Additional charts provide safe load limits for different spans under imposed or wind suction loads for single, double, or multi-span conditions. Notes provide details on the load calculations and assumptions.

Uploaded by

Qadir Mohideen
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
106 views1 page

RoofDek D46 Load Table

This document provides material specifications and load capacity information for RoofDek D46 profiled steel roof decking. It includes specifications for decking made of 0.7mm, 0.9mm, and 1.2mm steel or aluminium. Charts show the decking's ultimate properties like moment capacity and section properties. Additional charts provide safe load limits for different spans under imposed or wind suction loads for single, double, or multi-span conditions. Notes provide details on the load calculations and assumptions.

Uploaded by

Qadir Mohideen
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

RoofDek D46

0.7mm S220 Colorcoat steelº


0.7mm S280 Interior liner or galvanised steel¹
0.9mm S280 Interior liner or galvanised steel¹
1.2mm S280 Interior liner or galvanised steel¹
0.9mm Rp0,2165 Stucco or coated aluminium²
1.2mm Rp0,2165 Mill finish aluminium³

Ultimate Section Properties to Eurocode


Broad flange in compression Narrow flange in compression 100 mm Bearing on steel beam
Material Design Weight Moment Moment of Moment Moment of
Transverse Resistance Shear Capacity
specification t Capacity Inertia Capacity Inertia
mm kg/m² kNm/m cm4/m kNm/m cm4/m Internal Rw End Rw kN/m
kN/m kN/m
0.7mm Steel S220º 0.64 7.20 2.32 27.61 2.46 29.57 17.72 4.13 34.24
0.7mm Steel S280¹ 0.66 7.20 2.89 28.04 3.12 30.73 21.40 5.02 41.73
0.9mm Steel S280¹ 0.86 9.26 4.13 39.17 4.28 40.04 34.17 8.29 65.91
1.2mm Steel S280¹ 1.16 12.37 6.62 53.98 5.80 53.98 57.79 14.59 88.90
0.9mm Alu 0.2% 165² 0.90 3.21 1.98 36.98 2.13 38.52 14.92 3.64 31.26
1.2mm Alu 0.2% 165³ 1.20 4.28 3.02 50.07 3.10 52.87 24.71 6.27 49.27

Safe Loads (kN/m²) Imposed load - deflection limit span / 200 Wind suction load - deflection limit span / 150
Span SPAN (metres)
Condition 1.00 1.20 1.40 1.60 1.80 2.00 2.20 2.40 2.60 2.80 3.00 3.20 3.40 3.60 3.80 4.00
Single 5.46 4.54 3.89 3.40 3.01 2.71 2.02 1.54 1.20 0.94 - - - - - -
0.7mm Steel

Imposed Double 7.30 6.07 4.90 4.04 3.39 2.89 2.50 2.18 1.92 1.70 1.52 1.36 1.23 1.08 0.91 -
S220º

Multi 6.84 5.69 4.87 4.26 3.78 3.40 2.99 2.61 2.31 1.84 1.49 1.21 1.00 - - -
Single 13.15 9.15 6.73 5.17 4.09 3.32 2.75 2.32 1.88 1.52 - - - - - -
Suction Double 12.43 8.65 6.37 4.88 3.87 3.14 2.61 2.20 1.88 1.63 1.42 1.26 1.12 1.00 0.90 -
Multi 15.53 10.80 7.95 6.09 4.82 3.92 3.25 2.73 2.34 2.02 1.77 1.56 1.39 - - -
Single 6.64 5.53 4.73 4.13 3.67 2.76 2.05 1.57 1.22 0.96 - - - - - -
0.7mm Steel

Imposed Double 8.87 7.39 6.05 5.00 4.21 3.59 3.11 2.72 2.39 2.13 1.90 1.59 1.32 1.10 0.92 -
Multi 8.31 6.92 5.93 5.18 4.60 4.13 3.71 3.02 2.36 1.87 1.51 1.23 1.02 - - -
S280¹

Single 16.70 11.61 8.54 6.55 5.19 4.20 3.17 2.46 1.95 1.58 - - - - - -
Suction Double 15.45 10.74 7.91 6.06 4.80 3.90 3.23 2.72 2.33 2.01 1.76 1.55 1.38 1.24 1.11 -
Multi 19.30 13.42 9.87 7.57 5.99 4.86 4.03 3.39 2.90 2.50 2.19 1.93 1.66 - - -
Single 10.99 9.15 7.83 6.85 5.33 3.86 2.88 2.19 1.71 1.35 1.08 - - - - -
0.9mm Steel

Imposed Double 14.56 11.30 9.07 7.46 6.25 5.32 4.59 3.99 3.51 3.11 2.73 2.23 1.85 1.54 1.30 1.10
Multi 13.75 11.45 9.81 8.57 7.45 6.36 5.50 4.22 3.30 2.62 2.12 1.73 1.43 1.19 1.00 -
S280¹

Single 22.90 15.92 11.71 8.98 7.11 5.47 4.13 3.20 2.54 2.05 1.69 - - - - -
Suction Double 22.11 15.37 11.31 8.67 6.87 5.57 4.62 3.89 3.32 2.87 2.51 2.21 1.97 1.76 1.59 1.44
Multi 27.62 19.20 14.12 10.83 8.57 6.95 5.75 4.85 4.14 3.58 3.10 2.57 2.16 1.83 1.57 -
Single 19.37 16.13 13.81 10.51 7.34 5.32 3.97 3.03 2.36 1.86 1.49 1.21 0.99 - - -
1.2mm Steel

Imposed Double 22.61 17.39 13.84 11.29 9.40 7.96 6.83 5.92 5.18 4.58 3.77 3.08 2.55 2.13 1.79 1.52
Multi 24.23 20.18 16.48 13.50 11.27 9.57 7.59 5.82 4.55 3.62 2.92 2.39 1.97 1.64 1.38 1.16
S280¹

Single 30.99 21.54 15.85 12.15 9.62 7.38 5.57 4.32 3.42 2.77 2.27 1.89 1.60 - - -
Suction Double 35.41 24.61 18.11 13.88 10.98 8.91 7.38 6.21 5.31 4.59 4.01 3.53 3.14 2.81 2.53 2.29
Multi 44.24 30.75 22.61 17.33 13.71 11.12 9.20 7.75 6.35 5.11 4.18 3.46 2.91 2.47 2.12 1.83
Single 4.83 4.02 3.44 2.40 1.67 1.21 - - - - - - - - -
0.9mm Alu 0.2%

Imposed Double 6.45 5.20 4.19 3.46 2.91 2.49 2.15 1.70 1.33 1.06 - - - - - -
Multi 6.04 5.03 4.31 3.77 3.18 2.31 1.73 1.33 1.04 - - - - - - -
165²

Single 11.38 7.91 5.06 3.40 2.40 1.76 - - - - - - - - -


Suction Double 10.60 7.37 5.42 4.15 3.29 2.66 2.21 1.86 1.59 1.37 - - - - - -
Multi 13.24 9.20 6.77 5.19 4.10 3.29 2.48 1.92 1.51 - - - - - - -
Single 8.33 6.93 4.86 3.24 2.27 1.64 1.22 - - - - - - - -
1.2mm Alu 0.2%

Imposed Double 10.54 8.19 6.58 5.41 4.54 3.86 3.01 2.31 1.80 1.44 1.16 0.95 - - - -
Multi 10.41 8.67 7.43 6.16 4.31 3.13 2.34 1.80 1.40 1.11 - - - - - -
165³

Single 16.56 11.01 6.95 4.67 3.29 2.41 1.82 - - - - - - - -


Suction Double 16.13 11.21 8.25 6.32 5.00 4.05 3.36 2.82 2.41 2.08 1.73 1.44 - - - -
Multi 20.16 14.01 10.30 7.89 6.17 4.51 3.40 2.63 2.08 1.67 - - - - - -

NOTES Black figures are stress limited, the load shown is the ultimate load divided by 1.5.
Blue figures are deflection limited.
Red figures show deck length exceeds 12m, these spans need extended end laps.
Mar-16 Calculations are to Eurocode, however additional checks such as fixings are required
T: +44 (0)1244 892 199 A construction line load 1.5 kN/m has been allowed for.
www.tatasteelconstruction.com Deck self weight has been allowed for, so does not have to be included in applied loads