This document summarizes the structural analysis and design of a steel beam-column connection. It includes the seismic design parameters, modeling of the structure in SAP2000, analysis of member forces and deflections, and design of the beam, column, and cleat connection for strength and serviceability limits states according to LRFD design code. The selected beam and column sections were verified to meet the strength requirements for flexure, axial compression, and the beam-to-column connection.

Uploaded by

Ahmet Karabulut
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
178 views17 pages

Sap2000 Project

This document summarizes the structural analysis and design of a steel beam-column connection. It includes the seismic design parameters, modeling of the structure in SAP2000, analysis of member forces and deflections, and design of the beam, column, and cleat connection for strength and serviceability limits states according to LRFD design code. The selected beam and column sections were verified to meet the strength requirements for flexure, axial compression, and the beam-to-column connection.

Uploaded by

Ahmet Karabulut
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 17

Columns & Beam Layout Plan

SAP2000 Model
Deflected Shape
Axial Force Diagram (KN)
Shear Force Diagram (KN)
Bending Moment Diagram (KN)
SEISMIC FORCES (ASCE 7-16)
Site parameters
Site class; C
Mapped acceleration parameters (Section 11.4.1)
at short period; SS = 1.50
at 1 sec period; S1 = 0.50
Site coefficientat short period (Table 11.4-1); Fa = 1.000
at 1 sec period (Table 11.4-2); Fv = 1.300
Spectral response acceleration parameters
at short period (Eq. 11.4-1); SMS = Fa  SS = 1.50
at 1 sec period (Eq. 11.4-2); SM1 = Fv  S1 = 0.65

Design spectral acceleration parameters (Sect 11.4.4)


at short period (Eq. 11.4-3); SDS = 2 / 3  SMS = 1.00
at 1 sec period (Eq. 11.4-4); SD1 = 2 / 3  SM1 = 0.43
Seismic design category
Risk category (Table 1.5-1); I

Seismic design category based on short period response acceleration (Table 11.6-1)
D
Seismic design category based on 1 sec period response acceleration (Table 11.6-2)
D
Seismic design category; D
Approximate fundamental period
Height above base to highest level of building; hn = 3.8 m

From Table 12.8-2:


Structure type; Steel moment frame
Building period parameter Ct; Ct = 0.0724
Building period parameter x; x = 0.80

Approximate fundamental period (Eq 12.8-7); Ta = Ct  (hn)x  1sec / (1m)x= 0.211 sec
Building fundamental period (Sect 12.8.2); T = Ta = 0.211 sec
Long-period transition period; TL = 12 sec
Seismic response coefficient
Seismic force-resisting system (Table 12.14-1); C_MOMENT_RESISTING_FRAME_SYSTEMS
1. Steel special moment frames
Response modification factor (Table 12.14-1); R=8
Seismic importance factor (Table 11.5-2); Ie = 1.000
Seismic response coefficient (Sect 12.8.1.1)
Calculated (Eq 12.8-2); Cs_calc = SDS / (R / Ie)= 0.125
Maximum (Eq 12.8-3); Cs_max = SD1 / (T  (R / Ie)) = 0.257
Minimum (Eq 12.8-5); Cs_min = max(0.044  SDS  Ie,0.01) = 0.044
Seismic response coefficient; Cs = 0.125
Seismic base shear (Sect 12.8.1)
Effective seismic weight of the structure; W = 850.0 kN
Seismic response coefficient; Cs = 0.125
Seismic base shear (Eq 12.8-1); V = Cs  W = 106.3 kN
Vertical distribution of seismic forces (Sect 12.8.3)
Vertical distribution factor (Eq 12.8-12); Cvx = wx  hxk / (wi  hik)
Lateral force induced at level i (Eq 12.8-11); Fx = Cvx  V
Vertical force distribution table
Portion of Distribution
Height from effective exponent Vertical Lateral force
Level base to Level i seismic weight related to distribution induced at
(m), hx assigned to building period, factor, Cvx Level i (kN), Fx;
Level i (kN), wx k
1 3.8; 850.000; 1.00; 1.000; 106.250;
;
Beam Design for Flexure
I-SECTION MEMBER DESIGN TO LRFD
Try section - W 360x64
h = d - 2  k = 290.0 mm; tw = 7.7 mm; bf = 203.0 mm; tf = 13.5 mm
 flange = bf_to_2tf =7.54; web = h_to_tw = 37.40
; Specified minimum yield stress; Fy = 345 N/mm2

Local buckling classification to LRFD B5.1 for x-axis flexure


(I section)
Flange is
COMPACT
Web is
COMPACT
DESIGN FOR FLEXURE (X-AXIS)

Flexure about x-axis - yielding limit state to LRFD F1.1


;;; Plastic moment; Mpx = min( Fy Zx , 1.5 Fy Sx ) = 393.3 kNm
; Design flexural strength; b =0.90; b  Mpx = 354.0 kNm
; Required flexural strength; Mux = 320.0 kNm
Pass -
yielding (x-
axis flexure)

Local buckling under flexure about x-axis ( I and channel sections) to LRFD Appendix F1
; Resistance factor; b = 0.9
Nominal flexural strength for limit state of flange buckling, Mnx_flange:-
Mnx_flange = if( flange < p_flange, Mpx, if(flange < r_flangeMnx_flange_nc, 0.1 kNm)) = 393.3 kNm
Nominal flexural strength for limit state of web buckling, Mnx_web:-
Mnx_web = if( web < p_web, Mpx, if(web < r_webMnx_web_nc, 0.1 kNm)) = 393.3 kNm
Design flexural strength for local buckling; b  min( Mnx_flange, Mnx_web ) = 354.0 kNm
; Required flexural strength; Mux = 320.0 kNm
Pass - local
buckling limit
state

Flexure (x-axis) - summary


;;;; Member is fully braced against lateral-torsional buckling.
Nominal flexural strength; Mnx = min( Mpx, Mnx_flange, Mnx_web ) = 393.30 kNm
Design flexural strength; bMnx = b  Mnx = 353.97 kNm
; Required flexural strength; Mux = 320.00 kNm
Pass - flexural
strength
;
Design of Column for Axial Compression
I-SECTION MEMBER DESIGN TO LRFD
Try section - W 310x60
h = d - 2  k = 251.4 mm; tw = 7.5 mm; bf = 203.0 mm; tf = 13.1 mm
 flange = bf_to_2tf =7.77; web = h_to_tw = 33.60
; Specified minimum yield stress; Fy = 345 N/mm2

Local buckling classification to LRFD B5.1


(I section)
Flange is
NON-
COMPACT
Web is NON-
COMPACT
DESIGN COMPRESSIVE STRENGTH TO LRFD E2
Unbraced lengths; Lx = 4.800 m ; Ly = 4.800 m
Effective length factors; Kx = 1.00 ; Ky = 1.00
Design compressive strength; c =0.85; cPn = c  Pnc = 1103.5 kN
Required compressive strength; Pu = 200.0 kN
Pass -
Compression
Effective
slenderness
ratio does not
exceed 200
BEAM TO COLUMN - CLEAT CONNECTION
Section Details
Column UC 305x305x97;; Gradecolumn = "S275"
Beam UB 533x210x92;; Gradebeam = "S275"
Cleats 2 x RSA 90x90x10;; Gradecleats = "S275"
Bolts M20 (Grade 8.8)

Connection Details
; Bolt eccentricity; abolts = 50 mm
; number of bolt rows; nbolts = 5
; Bolt pitch;; pbolts = 70 mm
; Bolt gauge; gbolts = 110 mm
; End projection; t1 = 10 mm
; Cleat end distance (top & bottom); e1cleats = 40 mm
; Cleat edge distance on beam; e2cleatsbeam = 40 mm
; Cleat edge distance on column; e2cleatscolumn = 40 mm
Cleat length; lcleats = pbolts(nbolts-1)+2e1cleats = 360 mm
; Beam end reaction; Q = 465.0 kN
Check 1 - Essential detailing requirements
; Cleat thickness; tcleats = 10 mm; PASS
; Bolt gauge; gbolts = 110 mm; PASS
; Cleat Length; lcleats = 360 mm
; Cleat length for torsional requirements : PASS;
; Cleats fit between beam fillets : PASS
Check 2 - Shear capacity of bolt group connecting cleats to web of supported beam (taking account
of eccentricity 'a')
;;;; Elastic section modulus of bolt group
Zbolts = nbolts  (nbolts + 1)  pbolts / 6 = 350 mm
Force on outermost bolt due to moment
Fm = Q  abolts / Zbolts = 66.4 kN
Force on bolt due to shear
Fv = Q / nbolts = 93.0 kN
Resultant force on bolt due to direct shear and moment
Fr = (Fv2 + Fm2)= 114.3 kN
Shear capacity of a single bolt in double shear
;2  Psbolts = 183.8 kN
Utilisation factor; Ucheck2shear = Fr / (2  Psbolts) = 0.622
Shear
capacity to
web : PASS
Check 3 - Shear and bearing capacity of cleat connected to supported beam
for shear
;;
pycleats = 275 N/mm2
;; e1acleats = e1cleats = 40 mm
;; Avcleats = 0.9  (2  e1acleats + (nbolts - 1)  pbolts)  tcleats = 3240 mm2
; Avnetcleats = Avcleats - nbolts  Dhbolts  tcleats = 2140 mm2
Effective net area coefficient
Kecleats = 1.20
Plain shear capacity of cleats
PvPcleats = min(0.6  pycleats  Avcleats, 0.7  Kecleats  pycleats  Avnetcleats) = 494.3 kN
Av1cleats = (e1acleats + (nbolts - 1)  pbolts)  tcleats = 3200 mm2
; Ateffcleats = (e2cleatsbeam - 0.5  Dhbolts)  tcleats = 290 mm2
PvBcleats = 0.6  pycleats  Av1cleats + 0.6  Kecleats  pycleats  Ateffcleats = 585.4 kN
Shear capacity of the angle cleat leg; Pvcleats = min (PvPcleats, PvBcleats) = 494.3 kN
;Shear force on angle cleat; Q / 2 = 232.5 kN
Utilisation factor; Ucheck3shear = Q / (2  Pvcleats) = 0.470
Shear capacity of cleats to beam: PASS
for bearing
ecleats = min (e1cleats, e2cleatsbeam) = 40 mm
bearing strength of the cleat
pbscleats = 460 N/mm2
bearing capacity of the leg of the angle cleat per bolt
Pbscleats = min(dbolts  tcleats  pbscleats, 0.5  ecleats  tcleats  pbscleats) = 92.0 kN
;Bearing force on cleat; Fr / 2 = 57.1 kN
Utilisation factor; Ucheck3bearing = Fr / (2  Pbscleats) = 0.621
Bearing capacity of cleats to beam: PASS
Check 4 - shear and bearing capacity of the supported beam
for shear
;;
pybeam = 275 N/mm2
; Distance from top of beam to top hole; etbeam = 90 mm
;;; etabeam = etbeam = 90 mm
; ebbeam = Dbeam - etbeam - (nbolts - 1)  pbolts = 163 mm
; Avbeam = (etabeam + (nbolts - 1)  pbolts + ebbeam)  tbeam = 5384 mm2
; Avnetbeam = Avbeam - nbolts  Dhbolts  tbeam = 4273 mm2
Effective net area coefficient
Kebeam = 1.20
Plain shear capacity of beam
PvPbeam = min(0.6  pybeam  Avbeam, 0.7  Kebeam  pybeam  Avnetbeam) = 888.4 kN
Av1beam = (etabeam + (nbolts - 1)  pbolts)  tbeam = 3737 mm2
;; e3beam = abolts - t1 = 40 mm
Ateffbeam = (e3beam - 0.5  Dhbolts)  tbeam = 293 mm2
Block shear capacity of beam
PvBbeam = 0.6  pybeam  Av1beam + 0.6  Kebeam  pybeam  Ateffbeam = 674.6 kN
Shear capacity of the beam; Pvbeam = min (PvPbeam, PvBbeam) = 674.6 kN
;Shear force on beam; Q = 465.0 kN
Utilisation factor; Ucheck4shear = Q / Pvbeam = 0.689
Shear capacity of beam : PASS
for bearing
bearing strength of the beam
pbsbeam = 460 N/mm2
bearing capacity of the beam per bolt
Pbsbeam = min(dbolts  tbeam  pbsbeam, 0.5  e3beam  tbeam  pbsbeam) = 92.9 kN
;Resultant bearing force on bolts; Fr = 114.3 kN
Utilisation factor; Ucheck4bearing = Fr / Pbsbeam = 1.230
Bearing capacity of beam : FAIL
Check 5 - Shear capacity of bolt group connecting cleats to supporting column
Shear capacity of top pair of bolts
;;;;; Psbolts1 = min(Psbolts, 0.5  e1cleats  tcleats  pbscleats) = 91.9 kN
Shear capacity of other bolts
Psbolts = 91.9 kN
Shear capacity of bolt group - sum of bolt capacities
;Psboltssum = 2  Psbolts1 + 2  (nbolts - 1)  Psbolts = 918.8 kN
;Shear on bolt group; Q = 465.0 kN
Utilisation factor; Ucheck5 = Q / Psboltssum = 0.506
Shear
capacity of
bolt group to
column :
PASS
Check 6 - Shear and bearing capacity of cleats connected to supporting column
for shear
;;
pycleats = 275 N/mm2
;; e1acleats = e1cleats = 40 mm
;; Avcleats = 0.9  (2  e1acleats + (nbolts - 1)  pbolts)  tcleats = 3240 mm2
Effective net area coefficient
Kecleats = 1.20
; Avnetcleats = Avcleats - nbolts  Dhbolts  tcleats = 2140 mm2
Plain shear capacity of cleats
PvPcleats = min(0.6  pycleats  Avcleats, 0.7  Kecleats  pycleats  Avnetcleats) = 494.3 kN
Av1cleats = (e1acleats + (nbolts - 1)  pbolts)  tcleats = 3200 mm2
; Ateffcleatscolumn = (e2cleatscolumn - 0.5  Dhbolts)  tcleats = 290 mm2
Block shear capacity of cleats
PvBcleatscolumn = 0.6  pycleats  Av1cleats + 0.6  Kecleats  pycleats  Ateffcleatscolumn = 585.4 kN
Shear capacity of the angle cleat leg; Pvcleatscolumn = min (PvPcleats, PvBcleatscolumn) = 494.3 kN
;Shear force on angle cleat; Q / 2 = 232.5 kN
Utilisation factor; Ucheck6shear = Q / (2  Pvcleatscolumn) = 0.470
Shear capacity of cleats to column: PASS
for bearing
ecleatscolumn = e1cleats = 40 mm
bearing strength of the cleat
pbscleats = 460 N/mm2
For top bolt,
bearing capacity of the leg of the angle cleat per bolt
Pbscleatscolumn1 = min(dbolts  tcleats  pbscleats, 0.5  ecleatscolumn  tcleats  pbscleats) = 92.0 kN
For other bolts,
bearing capacity of the leg of the angle cleat per bolt
Pbscleatscolumn = dbolts  tcleats  pbscleats = 92.0 kN
Capacity of bolt group;
Pbscleatscolumnsum = 2  Pbscleatscolumn1 + 2  (nbolts - 1)  Pbscleatscolumn = 920.0 kN
Bearing force on bolt group; Q = 465.0 kN
Utilisation factor; Ucheck6bearing = Q / Pbscleatscolumnsum = 0.505
Bearing capacity of cleats to column: PASS
Check 7 - Local shear and bearing capacity of column flange
for shear
;; etbeama = etbeam = 90 mm
;;; Avcolumn = (pbolts + (nbolts - 1)  pbolts + etbeama)  Tcolumn = 6776 mm2
; Avnetcolumn = Avcolumn - nbolts  Dhbolts  Tcolumn = 5082 mm2
;
pycolumn = 275 N/mm2
Effective net area coefficient
Kecolumn = 1.20
Pvcolumn = min(0.6  pycolumn  Avcolumn, 0.7  Kecolumn  pycolumn  Avnetcolumn) = 1118.0 kN
;Shear load on column; Q / 2 = 232.5 kN
Utilisation factor; Ucheck7shear = Q / (2  Pvcolumn) = 0.208
Local shear capacity of column web: PASS
for bearing
pbscolumn = 460 N/mm2
Pbscolumn = dbolts  Tcolumn  pbscolumn = 141.7 kN
Q / (2  nbolts) = 46.5 kN
Utilisation factor; Ucheck7bearing = Q / (2  nbolts  Pbscolumn) = 0.328
Local bearing capacity of column web : PASS
Check 8 - Structural integrity - tension capacity of pair of web angle cleats
;Structural integrity tie force; Ftintegrity = 75.0 kN ;;;
eecleats = min(e1cleats, e2cleatscolumn) = 40 mm
; pecleats = min(pbolts, 2  e2cleatscolumn) = 70 mm
;; Lecleats = 2  eecleats + (nbolts - 1)  pecleats - nbolts  Dhbolts = 250 mm
;;; Ptintegritycleats = select(Gradecleats,“S275”, 0.6,”S355”,0.5,”S460”,0.5,”300”,0.6 -
0.1(45/80),”350”,0.5)Lecleatstcleatspycleats = 412.5 kN
Utilisation factor; Ucheck8 = Ftintegrity / Ptintegritycleats = 0.182
Local tension capacity of cleats for structural integrity : PASS
Check 9 - Structural integrity - tension and bearing capacity of beam web
for tension
;;; eebeam = min(e3beam, etbeam) = 40 mm
; pebeam = min(pbolts, 2  e3beam) = 70 mm
;; Effective net length of beam; Lebeam = 2  eebeam + (nbolts - 1)  pebeam - nbolts  Dhbolts
Lebeam = 250 mm
;;Net tension capacity of beam web; Ptintegritybeam = Lebeam  tbeam  pybeam = 694.4 kN
Utilisation factor; Ucheck9tension = Ftintegrity / Ptintegritybeam = 0.108
Tension capacity of beam web for structural integrity : PASS
for bearing
;
pbgbeam = 690 N/mm2
bearing capacity of beam web
;Pbgbeamweb = min(nbolts  dbolts  tbeam  pbgbeam, nbolts / 3  e3beam  tbeam  pbgbeam) = 464.6 kN
Utilisation factor; Ucheck9bearing = Ftintegrity / Pbgbeamweb = 0.161
Bearing capacity of beam web for structural integrity : PASS
Check 10 - Structural integrity - tension capacity of bolts in presence of extreme prying
;; pta = 300 N/mm2
;;Tension capacity of tension bolt group; Ptbolts = 2  nbolts  Atbolts  pta = 735.0 kN
Utilisation factor; Ucheck10 = Ftintegrity / Ptbolts = 0.102
Tension
capacity of
bolt group for
structural
integrity :
PASS

SUMMARY OF RESULTS
Check 2 - Capacity of bolt group connecting cleats to web of supported beam (taking account of
eccentricity 'a')
Shear utilisation factor; Ucheck2shear = 0.622; PASS
Check 3 - Capacity of cleat connected to supported beam
Shear utilisation factor; Ucheck3shear = 0.470; PASS
Bearing utilisation factor; Ucheck3bearing = 0.621; PASS
Check 4 - Capacity of the supported beam
Shear utilisation factor; Ucheck4shear = 0.689; PASS
Check 5 - Capacity of bolt group connecting cleats to supporting column
Shear utilisation factor; Ucheck5 = 0.506; PASS
Check 6 - Capacity of cleats connected to supporting column
Shear utilisation factor; Ucheck6shear = 0.470; PASS
Bearing utilisation factor; Ucheck6bearing = 0.505; PASS
Check 7 - Local capacity of column flange
Shear utilisation factor; Ucheck7shear = 0.208; PASS
Bearing utilisation factor; Ucheck7bearing = 0.328; PASS
Check 8 - Structural integrity - capacity of pair of web angle cleats
Tension utilisation factor; Ucheck8 = 0.182; PASS
Check 9 - Structural integrity - capacity of beam web
Tension utilisation factor; Ucheck9tension = 0.108; PASS
Bearing utilisation factor; Ucheck9bearing = 0.161; PASS
Check 10 - Structural integrity - capacity of bolts in presence of extreme prying
Tension utilisation factor; Ucheck10 = 0.102; PASS