Axcent Cetus x12 Brochure en 0120

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

Patient Monitoring Solutions

www.axcentmedical.com
www.axcentmedical.com
CETUS x12 Patient Monitor
Features
• 12.1” color TFT LCD screen
•YCXGHQTOFKURNC[WRVQNGCF'%)CPCN[UKU
•7UGHWNECNEWNCVKQP
(Hemodynamic, Drug Dose, Oxygenation, Ventilation)
• Pacemaker detection
• ST & arrhythmia analysis
• OxyCRGs screen
• Wired/Wireless CMS, support HL7 protocol to HIS
• SpO2 pulse-tone modulation (Pitch Tone)
•/'95
/QFKƒGF'CTN[9CTPKPI5EQTG 
•)TCRJKECNVCDWNCTVTGPFTGXKGY
JQWTU
• Rechargeable Lithium-Ion Battery (2600 mAh)
˽FRORU7)7/&'VFUHHQZLGHDQG̩DWVFUHHQGHVLJQ HFoQRPLFDQGUHOLDEOH

%QPƒIWTCVKQP'%) 5R1 0+$2 6'/2 24 4'52.KKQPDCVVGT[


1RVKQPCN6QWEJ5ETGGPNGCF'%)/CUKOQ5R1+$2%1'V%1/WNVK)CU$+50/6
VGA, Thermal Recorder, Wired/Wireless CMS

7HFKQLFDO6SHFL̨FDWLRQV

Display RESP
12.1” TFT (touch screen optional) Measurement method: Thoracic electrical
Resolution: 800 x 600 bioimpedance
0WODGTQHVTCEGUYCXGHQTOU Rate: 0 – 150 bpm
Measuring lead: Lead I, II
ECG 9CXGICKP€€€€
Lead type: 3-lead, 5-lead, 12-lead 4GURKTCVQT[KORGFCPEGTCPIGµ
'%)YCXGHQTOEJCPPGNUEJCPPGNU $CUGNKPGKORGFCPEGµ
12 channels Gain: 10 grades
&KURNC[UGPUKVKXKV[OOO8
€  Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s
5 mm/mV (×0.5), 10 mm/mV (×1.0),
20 mm/mV (×2.0) Pulse Rate
9CXGUYGGRURGGFOOUOOU Range: 30~254 bpm
25 mm/s, 50 mm/s Resolution: 1bpm
Bandwidth #EEWTCE[pDRO
PQPOQVKQP
Diagnostic mode: 0.05 Hz~100 Hz pDRO
OQVKQP
Monitor mode: 0.5 Hz~40 Hz 4GHTGUJKPITCVGU
Surgery mode: 1Hz~20Hz
 5VTQPIƒNVGTOQFG*\`*\ TEMP
CMRR >100 dB #EEWTCE[po%QTpo%o(
YKVJQWVRTQDG 
0QVEJ*\PQVEJƒNVGTECPDGUGVVQ Measurement range: 5~50 °C (41~122 °F)
QPQTQHH Channel: Two channels
&KHHGTGPVKCNKPRWVKORGFCPEG /µ Resolution: 0.1 °C
'NGEVTQFGRQNCTK\CVKQPXQNVCIGTCPIGpO8 Parameters: T1,T2 and TD
$CUGNKPGTGEQXGT[VKOGUCHVGTFGƒDTKNNCVKQP
(in monitor and surgery mode)
Calibration signal: 1mV (peak - peak),
CEEWTCE[p

7-lead ECG

www.axcentmedical.com
CETUS x12 Patient Monitor
7HFKQLFDO6SHFL̨FDWLRQV

NIBP SpO2
Measurement method: Automatic oscillome- /GCUWTGOGPVTCPIG
tric method 4GUQNWVKQP
Operating mode: Manual, automatic, #EEWTCE[p
#FWNV2GFKCVTKE 
continuous p
0GQPCVG 
Measurement unit: mmHg/kPa selectable WPURGEKƒGF
Typical measurement time: 20~40 s 4GHTGUJKPI4CVGU
Measurement type: Systolic, Diastolic, Mean
Measurement range (mmHg) Masimo SET® SpO2 (Optional)
4CPIGQH5[UVQNKERTGUUWTG #FWNV  /GCUWTGOGPVTCPIG
Pediatric 40-200 4GUQNWVKQP
 0GQPCVCN  #EEWTCE[p
#FWNV2GFKCVTKE
4CPIGQH&KCUVQNKERTGUUWTG #FWNV  PQPOQVKQPNQYRTGHWUKQP 
Pediatric 10-150 p
0GQPCVG
 0GQPCVCN  PQPOQVKQP 
4CPIGQH/GCPRTGUUWTG #FWNV  p
OQVKQP 
Pediatric 20-165 WPURGEKƒGF
 0GQPCVCN  4GHTGUJKPI4CVGU
Measurement accuracy
Recorder (Optional)
/CZKOWOCXGTCIGGTTQTpOO*I
Built-in, Thermal dot array
/CZKOWOUVCPFCTFFGXKCVKQPOO*I
Horizontal resolution: 16 dots/mm (25 mm/s
Resolution: 1 mmHg
paper speed)
+PVGTXCN
Vertical resolution: 8 dots/mm
240, 480 minutes
Paper speed: 25 mm/s, 50 mm/s
1XGTRTGUUWTGRTQVGEVKQP5QHVYCTGCPF
0WODGTQHYCXGHQTOEJCPPGNU
JCTFYCTGFQWDNGUCHGV[RTQVGEVKQP
%WHHRTGUUWTGTCPIGOO*I
Operation Environment
Power: AC 100-250V, 50/60Hz
Temperature: 5-40 °C
*WOKFKV[
2CVKGPV4CPIG#FWNV2GFKCVTKE0GQPCVG
Battery backup: Standard 2-3 hrs (2.600 mAh),
optional 3-5 hrs (4.800 mAh)
Patient Monitoring Solutions
(QTOQTGKPHQTOCVKQPRNGCUGEQPVCEVWU

aXcent medical GmbH


,QUGH)ȘTTGU2NCV\
56068 Koblenz
Germany
2JQPG 
(CZ 
/CKNKPHQ"CZEGPVOGFKECNEQO

www.axcentmedical.com
AX.MON.01-02EN - Edition 10.2019