ELSAP11D

This document is a data sheet for designing and fabricating flooded-cell lead-acid batteries for electrical stations. It lists general requirements and specifications for site conditions, cell capacity, battery racks, accessories, shipping, documentation, cables, hydrogen evolution rates, fault currents, and plate design that are needed to size and configure the battery system. Information to be provided by the buyer, bidder, or seller is also indicated.

Uploaded by

Jhonny Rincones
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
103 views1 page

ELSAP11D

This document is a data sheet for designing and fabricating flooded-cell lead-acid batteries for electrical stations. It lists general requirements and specifications for site conditions, cell capacity, battery racks, accessories, shipping, documentation, cables, hydrogen evolution rates, fault currents, and plate design that are needed to size and configure the battery system. Information to be provided by the buyer, bidder, or seller is also indicated.

Uploaded by

Jhonny Rincones
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 1

ASSOC. PIP Data Sheet for Design and Fab.

of Flooded-Cell ELSAP11D
ELSAP11 Lead-Acid Batteries for Electrical Stations PAGE 1

Client       Engineering Org.       Spec. No.      

Project Title       Location       Date      


Project Location       Contract Number       Equip. No.      

Proj. No.       Specifier Name       Tele. No.      


P. O. No.      

Refer to Specification No. ELSAP11 for General Requirements


Applicable State and Local Codes:      

Data Provided by:  Buyer  Bidder with Proposal  Seller after Order

Site Conditions (4.1.1): Plate Alloy (4.2.1):


Altitude       ft. Seismic Zone    Lead-Calcium Lead-Antimony

Ambient Temperature: Max.     F Min.     F Other      

Ampere-Hour Cell Capacity (4.1.6): Battery Rack (4.3.2):


Discharge Rate @ 25 Celsius Single Tier Two-Step Two-Tier
 0.5 Hr      Amp-Hr Maximum Height of Battery Tops      
 1.0 Hr      Amp-Hr Other Accessories (4.4.2):
 5.0 Hr      Amp-Hr      

 8.0 Hr      Amp-Hr      


 Max. Battery Float Voltage (4.1.6):     VDC      

 Design Ambient Temperature (4.1.6):    C Shipping (6.2):

Load Options for Battery Sizing (4.1.7): Ship Cells Filled with Electrolyte
Continuous Amperes:      A for     Minutes Ship Cells Dry-Charged
Load Profile:       Documentation (7.2):
Battery Ampere Capacity at 8-hr Rate:      A Electronic Document Format
Number of Cells (4.1.8): .DXF Other      
Quantity     Manufacturer to Provide:
Nominal Battery Voltage     VDC    Reproducible Plus

Incoming Cables & Connections (4.1.10):    Copies of All Documentation Plus


Quantity    Size          Copies of Operating Manuals

Cable Lugs Terminal Block Notes and Other Requirements:


Hydrogen Evolution (4.1.12):      
 Evolution Rate            

Maximum Fault Current (4.1.13):      


       Amperes      

Plate Design (4.2.1):      


Tubular Pasted Plate      

     
     

     
     

     