0% found this document useful (0 votes)
61 views2 pages

CTSE2024

This document describes a two-coat epoxy mastic primer and aliphatic urethane finish coating system. The system can be used on manufacturer's standard finished items and galvanized steel after preparing the surface by hand or power tool cleaning. The system involves applying an epoxy mastic primer in 4-6 mil coats followed by a 2-3 mil aliphatic urethane finish coat. Application is to be according to the manufacturer's instructions.

Uploaded by

Jhonny Rincones
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
61 views2 pages

CTSE2024

This document describes a two-coat epoxy mastic primer and aliphatic urethane finish coating system. The system can be used on manufacturer's standard finished items and galvanized steel after preparing the surface by hand or power tool cleaning. The system involves applying an epoxy mastic primer in 4-6 mil coats followed by a 2-3 mil aliphatic urethane finish coat. Application is to be according to the manufacturer's instructions.

Uploaded by

Jhonny Rincones
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 2

ASSOC.

PIP:
External Coating Systems PIP CTSE2024
CTSE2000

Epoxy Mastic/Urethane PAGE 1 OF 2


EM/UR February 2001

Project:       System Reference No.:       Date:      

Description:
Epoxy mastic primer (EM) with an aliphatic urethane finish (UR).

Surfaces:
Manufacturer’s Standard finished items where abrasive blast cleaning for top-coating is not practical. This system is also
suitable for galvanized steel.

Surface Preparation: Prepare the surface per SSPC SP-2 or -3. Check compatibility by top-coating a small area;
proceed if no lifting of the existing Manufacturer’s Standard finish is observed.

SYSTEM
Coat Type Application Minimum Maximum Shop (S)/
No. Code Generic Type Method* DFT, mils DFT, mils Field (F)
1. - Manufacturer’s Standard - - -      
2. EM Epoxy Mastic S, B, R 4 6      
3. UR Aliphatic Urethane Finish S, B, R 2 3      
Total: 6 9
*Application Method: S=Spray; B=Brush; R=Roller
Notes:
Unless otherwise specified, refer to the coating manufacturer's data sheets for information on the recommended
application temperature range, wet film thickness, approximate coverage in square feet/gallon, pot life, and drying times to
touch, handle, and cure for each coating product.
     
Mixing and Thinning: Mix according to manufacturer’s instructions and SSPC PA-1.

Application: Apply according to manufacturer’s instructions and PIP CTSE1000.

Job Stencil Required: Yes No


Repair:
     
ASSOC. PIP:
External Coating Systems PIP CTSE2024
CTSE2000
Epoxy Mastic/Urethane PAGE 2 OF 2
EM/UR February 2001

Project:       System Reference No.:       Date:      

Coat 1 Coat 2 Coat 3


Manufacturer
Manufacturer’s Standard Epoxy Mastic Urethane
                       
                       
                       
                       
                       
                       
                       
                       
                       
                       
                       
                       
                       
                       
                       
Notes:
     