0% found this document useful (0 votes)
71 views

Dual Input Monitor Module 6007

The VF6007 dual input monitor module provides monitoring of two contacts, such as a water flow switch and valve supervision, using a single address on the SLC loop. It can monitor up to 127 normally open or normally closed devices and has fast and reliable contact monitoring using VES's Digital Communication Protocol. The module fits in a standard 4" square electrical box and its bi-colored LED indicates module status.

Uploaded by

Vanhalen Blanco
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
71 views

Dual Input Monitor Module 6007

The VF6007 dual input monitor module provides monitoring of two contacts, such as a water flow switch and valve supervision, using a single address on the SLC loop. It can monitor up to 127 normally open or normally closed devices and has fast and reliable contact monitoring using VES's Digital Communication Protocol. The module fits in a standard 4" square electrical box and its bi-colored LED indicates module status.

Uploaded by

Vanhalen Blanco
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Dual Input Monitor Modules

VF6007-00

Standard Features
• Fast, reliable contact monitoring utilizing the VES
DCP (Digital Communications Protocol)
• 127 devices can be used per DCP loop
• Bi-colored indicating LED provides module status
• Dual input contact monitor
• Can be programmed to monitor Normally Open
(NO) or Normally Closed (NC) contacts
• Operates on Class A or Class B SLC loop
• Accepts up to 14 AWG wire
• Mounts to 4” square gang box

VF6007 Application
The VES VF6007 provides installing dealers an economical approach
to monitor devices in the same proximity, such as water flow and valve
supervision on the same interface device.
Technical Specifications
This capability when coupled with VES’s SIA DACT transmission provides
Operating Voltage 17-41 VDC
sub-point reporting for complete annunciation and accurate reporting to
Average Current Consumption 600μA (Typical) responders and users.
Alarm Current 30 mA
Maximum Quantity per Loop 127 VES’s reporting approach is superior in that the capability to accurately
Mounting 4” Square Electrical Box report dissimilar inputs, such as alarm and supervisory are present.
Maximum Humidity up to 90%, non-condensing
UL Ambient Installation
Temperature Range
32º F to 120º F
Operation
The VES Dual Monitor Module (VF6007) is designed for use on the
Dimensions 4.2” W x 4.7” H x 1.4” D
Elite analog addressable system. It provides two independent contact
monitoring circuits while only utilizing one address on the SLC loop.

Up to 127 devices can be placed on a single SLC loop. The device


address is uniquely stored on an onboard EEPROM. The module can be
programmed to monitor normally open (NO) or normally closed (NC)
contact fire alarm and supervisory devices.

The interrupt driven Digital Communication Protocol (DCP) combines


maximum communication reliability and fast response to emergency
conditions.

The module has a single bi-colored LED to


indicate device status. It fits into a standard
4” square or double gang electrical back box.

VES Fire Detection Systems | 620 Allendale Road | King of Prussia, PA 19406 | 800.270.3066 | www.ves-network.com