DPS-C

Instrument Clusters
Catalog MSG33-5014/US
Catalog MSG33-5014/US
Technical data DPS-C Instrument Clusters

Application General
The DPS-C is a general purpose display for vehicle Weight 1.2 kg
instrumentation. There is a standard electronic Temperature range
configuration and standard overlay. The end user can - Operating, ambient -20 to +60°C
customize the DPS-C with a custom overlay and custom - Storage, ambient -40 to +85°C
application software. By incorporating the new cluster, a Protection IP69 (front), IP65 (rear)
wide range of industrial vehicles can be operated more Voltage supply 8 - 32 Vdc
efficiently for greater productivity. Current (standby) 1 mA (12V), 2 mA (24V)

Communication
Properties CAN (SAE J1939) 2
Features USB, B-port 1 (via separate cable)
This versatile instrument cluster supports two CAN Outputs
communication channels, as well as USB. The DPS-C Digital out high-side 2
has 18 digital inputs: 4 are active high with wake-up. - Type high-side switch
There are 4 analog inputs, and 2 frequency inputs. For - Max load 2.5 A
outputs the DPS-C has 2 high-side and 2 low-side. The - Max PWM frequency 200 Hz
outputs provide a maximum current of 2.5 A with pulse Digital out low-side 2
width modulation capabilities. Low-side outputs have - Type low-side switch
analog feedback which provides open circuit, short to - Max load 2.5 A
battery, and ground detection. - Max PWM frequency 200 Hz

Reliability Inputs
Voltage inputs 4
The DPS-C cluster is ideal for various industrial and
- Signal range 0 - 5 Vdc
off-road vehicle applications, with five backlit gauges,
- Absolute error 2%
28 positions for LED status indicators (tell-tales) and
Frequency inputs 2
a 3.5”, transflective color LCD, 320 x 240 pixel screen.
- Signal range 5 - 6500 Hz
The robust enclosure is designed to be used in rugged
Digital inputs 18
environments, and has been tested to a suitable mix
- Signal high 2.43 Vdc - VBAT
of standards based on the J1455, ISO, and EP455
- Signal low 0 - 0.80 Vdc
environmental specifications. The connectors are
rugged, environmentally sealed, Molex MX150 type. Ordering part numbers
DPS-C 0971001ECD

2 Parker Hannifin Corporation


Electronic Controls Division
Elk Grove Village, IL 60007 USA
Catalog MSG33-5014/US
Technical data DPS-C Instrument Clusters

Environmental protection

EMI Mechanical environment


J1455 Section 4.13.1, Over-voltage BS EN7691 Section 6.6.1, Random vibration
J1455 Section 4.13.1, Reverse polarity EP455 Section 5.14.2.2, Drop test
J1455 Section 4.13.1, Short circuit
Climate environment
ISO7637 Section 5.6.x, EP455 Section 5.11.x, Transients
IEC 60529 Section 14.2.6, Water IP65 (rear only)
EP455, ISO, J1113-41, EMC emissions
IEC 60529 Section 13.6.8, Water IP69 (front only)
EP455, ISO, J1113-41, EMC susceptibility
IEC 68-2-2 Section 2, High temperature
ESD IEC 68-2-1 Section 2, Low temperature
EP455 Section 5.12, ESD (surface) EP455 Section 5.1.1, Temperature cycle
EP455 Section 5.12, ESD (connectors) J1455 Section 4.1.3.2, Temperature shock
EP455 Section 5.13.2, Humidity soak
Chemical environment EP455 Section 5.13.1, Humidity cycle
MIL_STD 202G M101E-B, Salt spray

257.4 53.3
[10.13”] [2.10”]

172.0
[6.77”]

units=mm
41.6 [inch]
[1.64”]

WARNING - USER RESPONSIBILITY


FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS
CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
• This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide
product or system options for further investigation by users having technical expertise.
• The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components
and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The
user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the
product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distribu-
tors.
• To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or
specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and
sufficient for all applications and reasonably foreseeable uses of the components or systems.

OFFER OF SALE
The items described in this document are hereby offered for sale by Parker-Hannifin Corporation, its subsidiaries or its authorized distributors. This offer
and its acceptance are governed by the provisions stated in the detailed “Offer of Sale” available from your Parker representative or at www.parker.com.

WARNING - California Proposition 65


This product can expose you to chemicals including VINYL CHLORIDE which is known to the State of California to cause cancer.
For more information go to www.P65Warnings.ca.gov

3 Parker Hannifin Corporation


Electronic Controls Division
Elk Grove Village, IL 60007 USA
Parker Motion Systems International Sales Offices
North America Industrial Sales Asia Pacific
Motion Systems Group Central Region Parker Hannifin Shanghai Ltd
Headquarters 1042 Maple Avenue 280 Yunqiao Road,
6035 Parkland Boulevard Unit 331 Jin Qiao Export Processing Zone
Cleveland, OH 44124-4141 USA Lisle, IL 60532 USA Shanghai 201206, China
Tel: 216-896-3000 Tel: 630-964-0796 Tel: 86 21 2899 5000
Fax: 216-896-4031 Great Lakes Region Fax: 86 21 6445 9917
Parker Canada Division 6035 Parkland Boulevard Parker Hannifin Hong Kong Ltd
160 Chisholm Drive Milton Cleveland, OH 44124-4141 USA 8/F, Kin Yip Plaza
Ontario Canada L9T 3G9 Tel: 216-896-2740 9 Cheung Yee Street
Tel: 905-693-3000 Fax: 866-498-7507 Cheung Sha Wan, Hong Kong
Fax: 905-876-1958 Gulf Region Tel: 852 2428 8008
Parker Hannifin de México 20002 Standing Cypress Drive Fax: 852 2425 6896
Industrial Hydraulic Sales Spring, TX 77379 USA Parker Hannifin Korea Ltd
Eje Uno Norte No.100 Tel: 817-473-4431 9F KAMCO Yangjae Tower
Parque Industrial Toluca 2000 Fax: 888-227-9454 949-3 Dogok1-dong, Gangnam-gu
Toluca, Edo, de Mexico CP 50100 Southwest Region Seoul, 135-860, Korea
Tel: 52 722 275 4200 700 S. 4th Avenue Tel: 82 2 559 0400
Fax: 52 722 279 9308 Mansfield, TX 76063 USA Fax: 82 2 556 8187
Parker Hannifin de México Tel: 817-473-9341 Parker Hannifin India Pvt Ltd
Mobile Hydraulic Sales Fax: 817-473-2680 Plot No. EL-26, MIDC
Via de FFCC a Matamoraos 730 Mid Atlantic and Southeast TTC Industrial Area
Apodaca, NL, de Mexico CP 66600 Regions Mahape, Navi Mumbai, 400 709 India
Tel: 52 81 8156 6000 1225 Old Alpharetta Road Tel: 91 22 6513 7081
Fax: 52 81 8156 6068 Suite 290 Fax: 91 22 2768 6841
Alpharetta, GA 30005 USA Parker Hannifin Australia
Europe Tel: 770-619-9767 Parker Hannifin Pty Ltd.
Motion Systems Group Fax: 770-619-9806 9 Carrington Road
Headquarters Midwest Region Castle Hill, NSW 2154, Australia
La Tuilière 6 8145 Lewis Road Tel: 612 9634 7777
1163 Etoy - Switzerland Minneapolis, MN 55427 USA Fax: 612 9842 5111
Tel: 41 21 821 8500 Tel: 763-513-3535
Fax: 41 21 821 8580 Fax: 763-544-3418 Latin America
Northeast Region Parker Hannifin Ind. e Com. Ltda
South Africa P.O. Box 396 Hydraulics Division
Parker Hannifin Africa Pty Ltd Pine Brook, NJ 07058 USA Av. FredericoRitter, 1100
P.O. Box 1153 Tel: 973-227-2565 94930-000 Cachoeirinha RS, Brazil
ZA-Kempton Park 1620, Fax: 973-227-2467 Tel: 55 51 3470 6090
Republic of South Africa Fax: 55 51 3470 9281
Northwest Region
Tel: 27 11 961 0700 6458 North Basin Avenue Parker Hannifin Argentina S.A.I.C.
Fax: 27 11 392 7213 Portland, OR 97217 USA Stephenson 2711
Tel: 503-283-1020 1667-Tortuguitas-Malvinas Argentinas
Mobile Sales Fax: 866-611-7308 Pcia. de Buenos Aires, Argentina
Mobile Sales Organization Tel: 54 3327 44 4129
Pacific Region
and Global Sales Fax: 54 3327 44 4199
8460 Kass Drive
850 Arthur Avenue Buena Park, CA 90621 Pan American Division
Elk Grove Village, IL 60007 USA Tel: 714-228-2510 7400 NW 19th Street, Suite A
Tel: 847-258-6200 Fax: 714-228-2511 Miami, FL 33126 USA
Fax: 847-258-6299 Tel: 305-470-8800
Fax: 305-470-8808
PB-DPS-C-202002-05
© 2011-2020 Parker Hannifin Corporation. All rights reserved. MSG33-5014/US 02/2020

Parker Hannifin Corporation


Electronic Controls Division
850 Arthur Avenue
Elk Grove Village, IL, 60007 USA
phone 800 221 9257
[email protected]
www.parker.com/ecd Your Local Authorized Parker Distributor