Melhor: Plumbing Symbols / Legend
Melhor: Plumbing Symbols / Legend
Melhor: Plumbing Symbols / Legend
10
0.10
SOIL I E 10 mm ∅ REBARS spaced
@ 0.15 M BOTH WAYS
ASTE I E
0.10
10 mm ∅ REBARS MH MH MH
DRAINAGE I E spaced @ 0.15 M BOTH
0.50
WAYS 4" ∅ PVC INLET PIPE
SOIL STAC X X
RISER
0.50
0.30
BOOSTER M X X
1.50
1.30
12 mm ∅ REBARS
ATER METER M spaced @ 0.15 M on 3"∅ PVC S - 1000
center (O.C.) OUTLET PIPES
GATE VALVE 10mm ∅ RSB HANDLE
CO CO CO
0.10
CHEC VALVE
LOOR DRAIN 4" ∅ PVC S - 1000
INLET PIPE 4" ∅ PVC OUTLET PIPE
LOOR CLEANO T CLEANO T
DIGESTIVE LEACHING LEACHING
0.10
TRA CHAMBER CHAMBER CHAMBER
GREASE TRA 0.50
CATCH BASIN CB 0.10 0.10 10 mm ∅ VERTICAL BARS
DO NS O T DS
0.10
MH CO CO MH CO MH
4" ∅ PVC INLET PIPE
0.10
1. ALL PLUMBING WORKS INCLUDED HEREIN SHALL BE EXECUTED ACCORDING TO THE 12 mm ∅ REBARS spaced @
10 mm ∅ REBARS spaced
0.15 M on center (O.C.) 4" CONCRETE HOLLOW
PROVISIONS OF THE LAW OF THE LOCAL ENFORCING AUTHORITY. @ 0.15 M BOTH WAYS
0.50
0.30
BLOCK (C.H.B.)
2. COORDINATE THE DRAWINGS WITH OTHER RELATED PLANS AND SPECIFICATIONS. THE
4" ∅ PVC S - 1000 AI R SPAC E AI R S P AC E AI R SPAC E 3" ∅ PVC S-1000 OUTLET PIPE 10mm ∅ BASE BARS
SANITARY ENGINEER SHALL BE NOTIFIED IMMEDIATELY OF ANY DISCREPANCY FOUND INLET PIPE spaced @ 0.15M O.C.
HEREIN.
1.20
10mm ∅ HORIZONTAL BARS spaced @
1.50
3. ALL PIPES SHOULD BE INSTALLED AS INDICATED ON PLANS. ANY RELOCATIONS
EVERY 3 LAYERS OF CHB DIGESTIVE LEACHING LEACHING
CHAMBER CHAMBER CHAMBER
REQUIRED FOR PROPER EXECUTION ON OTHER TRADES SHALL BE WITH PRIOR 12 mm ∅ REBARS 4" ∅ PVC OUTLET PIPE
spaced @ 0.15 M O.C.
APPROVAL OF THE ARCHITECT OR ENGINEER.
4. PROPOSED SANITARY UTILITIES SHALL CONFORM TO THE ACTUAL LOCATION DEPTHS 4" CONCRETE HOLLOW BLOCKS 10 mm ∅ BASE BARS spaced
S LU D G E @ 0.15 M on center (O.C.)
AND INVERT ELEVATIONS OF ALL EXISTING PIPES AND STRUCTURES VERIFIED BY S LU D G E
CHB WALL OR
PARTITION
FAUCET
HANDLE
CAPPED
REFER TO ARCH'L. DWG.
50Ø VENT
LAVATORY
50∅ VENT
20Ø CWL
.85 CM
BRACKET
15∅ CWL
P-TRAP
P-TRAP CLEAN OUT CHB WALL OR
CO
.50
PARTITION
FIN. FLR.LINE
FLOOR FLANGE
PREPARED FROM THE OFFICE OF: PROJECT TITLE: PREPARED BY: SHEET CONTENTS: SHEET NO.
DECENA, VON PHILIP S. VERGERE, JIMBERLY JOICE SURATOS, JOHN MICHAEL SANITARY NOTES
SEPTIC TANK DETAILS
MELHOR URDANETA CITY CENTRAL TERMINAL : PROPOSED PROJECT MANAGER ARCHITECTURAL DESIGNER SITE ENGINEER
CATCH BASIN DETAILS
RAMOS, MARK JEWEL DON E. FERNANDEZ, JOSEPH KONRAD CARAMAT, SUNSHINE
PROJECT ENGINEER STRUCTURAL ENGINEER SAFETY ENGINEER P06
TRANSPORT TERMINAL WITH 3 STOREY COMMERCIAL SPACE SALVADOR, SWEET CARESS SANDOVAL, ARJUN PAUL BUADA, JOHNRHEY B.
CONSTRUCTION COMPANY PLANNING ENGINEER QUANTITY SURVEYOR SAFETY OFFICE
ILUMIN, JAICA MAE BAUTISTA, CHRISTIAN
LOCATION: Brgy. Nancayasan, Urdaneta City, Pangasinan, Philippines QA/ QC ENGINEER PROJECT SCHEDULER