CET
VISUALIZED DIGITAL
PERIOD COUNTER
WITH TWO SET POINTS
LFM42
PROGRAMMABLE DIGITAL VISUALIZATOR OF
ROTATIONS WITH 4 DIGITS, WITH TWO SET
POINTS AND INPUT SUITABLE FOR MONO
DIRCTIONAL COUNTING.
The period counter model LFM42 is used to display and
control, through a relay threshold, rotational or linear
speeds or counting referred to a pre selected time base.
All the common types of controls are available using five
different programmable operations.
It reads signals coming form electromechanical and
logical contacts, proximity switches and encoder.
It finds application like RPM meter, tachometer, speed
meter, productions meter etc.
TECHNICAL FEATURES
• POWER SUPPLY IN ALTERNATE CURRENT : 230 Vac (50 / 60 Hz).
• POWER SUPPLY IN DIRECT CURRENT : 24 Vdc
• POWER SUPPLY TOLERANCE : +10% - 15%.
• ABSORPTION : 2 W - 3 VA.
• OPERATING TEMPERATURE : -5 °C + 55 °C.
• CLIMATIC CONDITIONS : U.R. 95 % a 40 °C (without condensate).
• COUNTER AND TOTALIZER VISUALIZATION : 4 digits, display high 14mm.
• MULTIPLICATION FACTOR OF THE INPULSES IN INPUT : programmable from 1 to 10000.
• DIVISOR FACTOR OF THE INPULSES IN INPUT : programmable from 1 to 10000.
• TIME BASE : Programmable between 1 / 60 / 3600.
• INPUT TYPE : suitable for electromechanical contacts, amplified proximity and
encoder, NPN and PNP
• MAXIMUM COUNT FREQUENCY : up to 25 KHz with Duty Cycle=50%.
• MINIMUM TIME FOR INPULSES COUNT : 0,25 mSec.
• CUT OFF FREQUENCY FOR ELECTROMECHANICAL : about 30 Hz.
INPUTS :
• COMMAND INPUTS : 1 Counter Reset - 1 Count Inhibit.
• OUTPUTS : 2 relays with operating contacts - capacity 2A - 250Vac.
• RESET RELAY : Manual or automatic with excitation time from 0,1 to 99,9 sec.
• AUXILIARY INPUT SUPPLY : 24 Vdc - 80 mA available on terminals.
• PROGRAMMED DATA MEMORY : Static (no battery)
ø YELLOW In programming phase it moves the cursor of the figure towards left of a step, than at the beginning it is
on the right side first one on the. At the end it resumes from the first one to right.
ù YELLOW The key 'UP ARROW' in normal operating phase visualizes the totalizer of impulses.
In programming phase it increases the value of the blinking figure.
ú BLUE The key 'PRG' pressed for 2 sec. allows to enter in the programming phase, visualizing on display
C.0000.
In the programming phase, pressing key 'PRG' impulsively, it exits from the programming phase. The
instrument exits automatically from the programming phase, 60 sec. after the pressure of the last key.
û RED The key 'ENT/RES' in normal phase of counting has the 'RESET' function, with the modalities to it
attributed in the programming phase.
In programming phase it confirms and memorizes the visualized data and passes to the successive
function. If it has arrived to list end it resumes from the beginning.
AC POWER
(input 3-4) 230 VAC Power Supply of the instrument.
24 VDC - 80mA
(input 5 - 6) 24 VDC - 80 mA auxiliary Power Supply that the instrument supply to feed the Encoder and amplified
proximity.
INPUT
(input 7) Input of count adapted for electromechanical and logical contacts, encoder and 3 wires proximity
amplified, configurable in Positive (PNP) and Negative (NPN) logic by the dip switches on the rear.
RESET
(input 8) Input of RESET that executes the reset visualized count showed on display at the moment of its
activation and of the relays depending on the programmed modality under code 020
INHIBIT
(input 9) Input of count inhibition: when activated it blocks the count of the normal counter and the totalizer.
RL2
(input 10 - 11) Output of Relay 2, connected to the operation of the Set Point S2. The Common and Normally Opened
contacts are available.
RL1
(input 12 - 13) Output of Relay 1, connected to the operation of the Set Point S1. The Common and Normally Opened
contacts are available.
LED 2 (FRONTAL) It comes activated to the reaching of the Set Points S2.
---- When the device is switched on and when there are no impulses in its input, the device
visualize 4 horizontal bars.
Pressing the key ù the totalizer of impulses will be visualized for 5 sec.
Toì The totalizer visualizes all the impulses that the instrument counts from its input IN1.
It can be resetted through frontal key RES only or from RESET input when it is visualized on
9999 the display.
Cod GROUP 1 : in order to approach the parameters of group 1, insert code 101 and press
000 ENT
¾Æ F.M. = 4 digits multiplier , programmable from 1 to 10000. This parameter allows to multiply
the number of the input impulses, showing them on the display in an other format. If it
¾¼ F.d. = 4 digits divisor, programmable from 1 to 10000. This parameter allows to divide the
number of the input impulses, showing them on the display in an other format. If it programmed
Cod GROUP 2 : in order to approach the parameters of GROUP 2, insert code 020 and press
000 ENT
½òÇ1 E.i = Delay Time for the excitation of the Relay output1.
This parameter allows to program the delay time of the activation of the Relay output RL1. It’s
programmable between 0 (no delay) and 9,9 sec.
¼òÇ1 d.i = Delay Time for the unexcitation of the Relay output1.
This parameter allows to program the delay time of the unactivation of the Relay output RL1.
It’s programmable between 0 (no delay) and 9,9 sec.
½ïÇ1 E.ii = Delay Time for the excitation of the Relay output2.
This parameter allows to program the delay time of the activation of the Relay output RL2. It’s
programmable between 0 (no delay) and 9,9 sec.
¼ïÇ1 d.ii = Delay Time for the unexcitation of the Relay output1.
This parameter allows to program the delay time of the unactivation of the Relay output RL2.
It’s programmable between 0 (no delay) and 9,9 sec..
rËoí Operation of the RESET Key; this programming enable and disable the RESET working of
the frontal RES key during the operation, as in the following modes:
rËon RS.ou. = executes the RESET of the visualized parameter + the Relay Output
RS.on. = executes the RESET of the visualized parameter
RS.oF. = RESET working of the RES key excluded.
RS.F.t. = executes, at the same time, the RESET of the frequencymeter, of the totalizer and
of the Relay Outputs
¼È 4
obtain counts with various resolutions.
d.p. = 0 Decimal Point excluded; visualization 9999
d.p. = 1 Decimal Point on the second display from right; visualization 999,9
d.p. = 2 Decimal Point on the third party display from right; visualization 99,99
d.p. = 3 Decimal Point on the fourth display from right; visualization 9,999
d.p. = 4 Floating Point.
Cod GROUP 3 : in order to approach the parameters of GROUP 3, insert code 121 and press
000 ENT
UÌ 0 Ut. = Programming of the RESET Input and of the operation of the INHIBIT time.
This programming allows to select the operation of the RESET input and the operation mode
of the Inhibit time.
Ut. = 0 Reset of the visualized value + relay (with inhibit time at the starting)
Ut. = 1 Frequency Reset only + relay (with inhibit time at the starting)
Ut. = 2 Frequency Reset + totalizer (at the same time) + relay (with inhibit time at
the starting)
Ut. = 3 Reset of the visualized value + relay (with inhibit time with the first impulse)
Ut. = 4 Frequency Reset only + relay (with inhibit time with the first impulse).
Ut. = 5 Frequency Reset + totalizer (at the same time) + relay (with inhibit time with the first
impulse).
CE NORMATIVE CONFORMITY
model: LFM42
EN55011
ENV50141
ENV50204
EN61000-4-2
EN61000-4-4
________________________________
Signature
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------
+ - AMPLIFIED PROXIMIT
AND ENCODER - 24 Vdc 7 6 7 5
24 VDC
8 6 9 6 8 5 9 5
OVERALL DIMENSIONS
FRONT SIDE
MORSETTIERA 10
ESTRAIBILE SQUADRETTE DI MAX
96 FISSAGGIO
6325
L1 L2 ENT
48
44x92
PROG
RES
15 115 9
139
44 45
1 2 3 4 5 6 7 8 9 10 11 12 13
93