The Seaward PV150 Solar Installation Tester allows electrical Why buy the
safety and performance verification of photovoltaic installations PV150?
in a safe and easy-to-use device.
> Easy to use – single key
Transforming the way PV systems are tested, the PV150 combines ground testing and measurement.
continuity, DC operating power and operating current test functions in > Small and compact – hand
a hand-held device. It can also test insulation resistance, open circuit held, rugged and robust
voltage and short circuit current at the push of a button. The unit can also device.
wirelessly capture and record real time irradiance, ambient temperature > Safe test connection – safely
and PV module temperature measurements from the Solar Survey 200R. test energized PV arrays.
> Easy to manage data –
The PV150 has memory to store up to 200 complete test records with USB
on board memory for test
connectivity to enable these to be quickly and easily downloaded to a PC. records with PC download.
Professional test certificates and reports can also be created when used
> Combines PV
with Seaward’s SolarCert software. commissioning tests –
required by IEC 62446.
These are just a few of the reasons we believe you’ll want to invest in our
PV150. > Free online product training
and support.
Technical Specification:
Open Circuit Voltage Measurement (PV Terminals)
Insulation Resistance (Auto Test Sequence, PV Terminals and Red 4mm Terminal)
Test Voltage Open Circuit 250V, 500V, 1000V (as per IEC61557-2)
Test Voltage Specification -0% +20% (open circuit)
Test Voltage @ 1mA >1mA into UN x (1000Ω/V)
Test Current Short Circuit <2mA
Display Range 0.05MΩ - 199MΩ
Insulation Resistance (Auto Test Sequence, PV Terminals and Red 4mm Terminal
Continued...
Measuring Range (EN 61557-2) 0.05MΩ - 199MΩ
Resolution 0.01MΩ maximum
Accuracy 0.05MΩ - 100MΩ ± (5% + 5 digits)
101MΩ - 199MΩ ± (10% + 5 digits)
Visible Warning ≥ 30V AC or DC at inputs
Circuitry Protection Test inhibited if ≥ 30V AC or DC at inputs
Service 388A915
2 year warranty (subject to terms and conditions, available at
www.seawardsolar.com/warranty)