60APU02
60APU02
60APU02
C 05/01
60EPU02
60APU02
Ultrafast Soft Recovery Diode
Features
• Ultrafast Recovery
• 175°C Operating Junction Temperature
trr = 35ns
Benefits
IF(AV) = 60Amp
• Reduced RFI and EMI
• Higher Frequency Operation
VR = 200V
• Reduced Snubbing
• Reduced Parts Count
Description/ Applications
These diodes are optimized to reduce losses and EMI/ RFI in high frequency power conditioning systems.
The softness of the recovery eliminates the need for a snubber in most applications. These devices are ideally suited
for HF welding, power converters and other applications where switching losses are not significant portion of the total
losses.
Case Styles
60EPU02 60APU02
BASE
BASE COMMON
COMMON CATHODE
CATHODE 2
2
1 3
ANODE ANODE
CATHODE ANODE
1 3
www.irf.com 1
60EPU02/ 60APU02
Bulletin PD-20739 rev. C 05/01
- - 2 mA TJ = 150°C, VR = VR Rated
LS Series Inductance - 8.0 - nH Measured lead to lead 5mm from package body
- 28 - TJ = 25°C IF = 60A
VR = 160V
- 50 - TJ = 125°C
diF /dt = 200A/µs
IRRM Peak Recovery Current - 4 - A TJ = 25°C
- 8 - TJ = 125°C
- 220 - TJ = 125°C
2 www.irf.com
60EPU02/ 60APU02
Bulletin PD-20739 rev. C 05/01
1000 1000
T J = 175˚C
100
1
25˚C
0.1
Instantaneous Forward Current - I F (A)
100
0.01
T = 175˚C 0.001
J
0 50 100 150 200
T = 125˚C Reverse Voltage - VR (V)
J
Fig. 2 - Typical Values Of Reverse Current
T = 25˚C Vs. Reverse Voltage
J
10000
Junction Capacitance - C T (pF)
10
T J = 25˚C
1000
100
1 10
0 0.5 1 1.5 2 2.5 1 10 100 1000
Forward Voltage Drop - VFM (V) Reverse Voltage - VR (V)
Fig. 1 - Typical Forward Voltage Drop Characteristics Fig. 3 - Typical Junction Capacitance
Vs. Reverse Voltage
1
Thermal Impedance Z thJC (°C/W)
D = 0.50
D = 0.20
D = 0.10
D = 0.05 PDM
D = 0.02
0.1
D = 0.01 t1
t2
Notes:
Single Pulse
(Thermal Resistance) 1. Duty factor D = t1/ t2
2. Peak Tj = Pdm x ZthJC + Tc
0.01
0.00001 0.0001 0.001 0.01 0.1 1 10
t1, Rectangular Pulse Duration (Seconds)
Fig. 4 - Max. Thermal Impedance Z thJC Characteristics
www.irf.com 3
60EPU02/ 60APU02
Bulletin PD-20739 rev. C 05/01
180 100
Allowable Case Temperature (°C)
170
150
60 D = 0.01
140 DC D = 0.02
D = 0.05
130 40
D = 0.10
Square wave (D = 0.50) D = 0.20
120 80% Rated Vr applied
D = 0.50
20
110 DC
see note (3)
100 0
0 20 40 60 80 100 0 20 40 60 80 100
Average Forward Current - IF(AV) (A) Average Forward Current - IF(AV) (A)
Fig. 5 - Max. Allowable Case Temperature Fig. 6 - Forward Power Loss Characteristics
Vs. Average Forward Current
70 800
40 400
300
30
200
20 Vr = 160V
Tj = 125˚C 100
Tj = 25˚C
10 0
100 1000 100 1000
di F /dt (A/µs ) di F /dt (A/µs )
Fig. 7 - Typical Reverse Recovery time vs. di F /dt Fig. 8 - Typical Stored Charge vs. di F /dt
4 www.irf.com
60EPU02/ 60APU02
Bulletin PD-20739 rev. C 05/01
VR = 200V
0.01 Ω
L = 70µH
D.U.T.
D
di F /dt
dif/dt
ADJUST IRFP250
G
3
trr
IF
ta tb
0
4
Q rr
2
I RRM 0.5 I RRM
di(rec)M/dt 5
0.75 I RRM
1 di fF/dt
/dt
1. diF/dt - Rate of change of current through zero 4. Qrr - Area under curve defined by t rr
crossing and IRRM
t rr x I RRM
2. IRRM - Peak reverse recovery current Q rr =
2
3. trr - Reverse recovery time measured from zero 5. di (rec) M / dt - Peak rate of change of
crossing point of negative going IF to point where current during t b portion of t rr
a line passing through 0.75 IRRM and 0.50 IRRM
extrapolated to zero current
www.irf.com 5
60EPU02/ 60APU02
Bulletin PD-20739 rev. C 05/01
Outline Table
14.80 (0.583) 1 3
Outline Table
3.65 (0.144)
15.90 (0.626) DIA.
5.30 (0.209) 60APU02
3.55 (0.139) 4.70 (0.185) 2.5 (0.098)
3 pins
15.30 (0.602)
1.5 (0.059)
5.70 (0.225)
5.30 (0.208) BASE
COMMON
20.30 (0.800) CATHODE
19.70 (0.775) 2
5.50 (0.217)
4.50 (0.177)
(2 PLCS.)
1 2 3
14.80 (0.583)
14.20 (0.559) 4.30 (0.170)
ANODE ANODE
3.70 (0.145) 1 3
6 www.irf.com
60EPU02/ 60APU02
Bulletin PD-20739 rev. C 05/01
Device Code
60 E P U 02
1 2 3 4 5
IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105
TAC Fax: (310) 252-7309
Visit us at www.irf.com for sales contact information. 05/01
www.irf.com 7