ROOFING & RE-ROOFING SOR 1 SCHEDULE OF RATES ROOFING & RE-ROOFING S/N 1 DESCRIPTION Supply and fix BRC

3315 welded fabric reinforcement to support sisalation paper of roof. Supply and fix wood wool slab to underside of roof. 2 3 25mm thick 50mm thick Supply and lay the following ferrocement secondary roof slabs, reinforced with galvanised fine mesh to reinforced concrete flat roof including all necessary supporting concrete solid blocks, labour and materials for sealing up pipes, etc. 4 5 6 900 x 600 x 20mm thick 600 x 600 x 30mm thick. Supply and lay 3mm thick acrylic polymer modified cementitious coating to roof surfaces and gutter. Apply a complete Waterproofing Membrane System to reinforced concrete flat roof consisting of 6 coats of waterproofing membranes, 1 layer of open woven glass membrane and 1 coat of bituminous aluminium finishing paint; complying with SS133:19 and its latest amendments and in accordance with the manufacturer's instructions Apply a complete Panel Roofing System to roof surfaces consisting of 38mm thick waterproofing cement and sand panel (1:3), 50mm thick Styrofoam insulation board or other approved equivalent and 6 coats of waterproofing membranes, 1 layer of open woven glass membrane and a minimum of 20mm thick waterproofing cement and sand screed (1:3) laid to fall and including all necessary labour and materials for jointing . Supply and fix 22G galvanised steel flashing not exceeding 400mm girth. m2 m2 m2 m2 33.90 21.13 11.50 m2 m2 23.40 32.40 UNIT m2 RATE ($) 2.80

8.50

m2

38.90

5.30

CD11/SOR-Building, Sanitary & Plumbing/Roofing & Re-roofing/(1)/[2009 Edition]

ROOFING & RE-ROOFING SOR 2 SCHEDULE OF RATES ROOFING & RE-ROOFING S/N 10 DESCRIPTION Supply and install 0.6mm thick hot dipped galvanised steel Scantile metal roofing coated with PVF2 Kynar 500 including all necessary fixing accessories and in accordance with manufacturer's instructions. Supply and install ridge/hip tile to Scantile metal roofing including all ridge/hip end capping piece and all necessary fixing accessories. Supply and install 0.53mm thick Speed Deck Hi-Ten colorbond metal roofing including all necessary fixing accessories. Supply and install colorbond ridge capping (type A) to Speed Deck Hi-Ten roofing including all necessary fixing accessories. Supply and install 0.47mm thick colorbond XRW Spandek HiTen metal roofing sheets including all necessary fixing accessories. Supply and install 0.47mm thick colorbond XRW Trimdek Hi-Ten metal roofing sheets including all necessary fixing accessories. Supply and install 0.53mm thick colorbond XRW Kliplok Hi-Ten metal roofing sheets including all necessary fixing accessories. Supply and install 0.65mm thick colorbond XRW Kliplok Hi-Ten metal roofing sheets including all necessary fixing accessories. Supply and install 0.47mm thick colorbond XRW V-Crimp HiTen metal roofing sheets including all necessary fixing accessories. Supply and install 0.60mm thick colorbond XRW standard ridge capping to Kliplok roofing including all necessary fixing accessories. Supply and install 0.60mm thick custom made colorbond XRW flashings/cappings/trims to Kliplok/ Spandek/V-Crimp roofing including all necessary fixing accessories. 20 Not exceeding 100mm m 7.40 UNIT m2 RATE ($) 43.10

11

27.70

12

m2

32.90

13

m m2

21.30

14

32.40

15

m2 m2 m2 m2

28.50

16

37.90

17

43.25

18

29.30

19

12.00

CD11/SOR-Building, Sanitary & Plumbing/Roofing & Re-roofing/(2)/[2009 Edition]

ROOFING & RE-ROOFING SOR 3 SCHEDULE OF RATES ROOFING & RE-ROOFING S/N DESCRIPTION Supply and install 0.60mm thick custom made colorbond XRW flashings/cappings/trims to Kliplok/ Spandek/V-Crimp roofing including all necessary fixing accessories. Contd 21 22 23 24 25 26 27 Exceeding 100mm but not exceeding 200mm Exceeding 200mm but not exceeding 300mm Exceeding 300mm but not exceeding 400mm Exceeding 400mm but not exceeding 500mm girth Exceeding 500mm but not exceeding 600mm girth Exceeding 600mm but not exceeding 700mm girth Supply and lay one layer of 'Parsec Thermo-brite II' double sided reflective roof heat insulation sheet including lapping with 'Parsec Thermo-brite' tape and secured to roof structure by selfdrilling fasteners complete with metal washers and in accordance with manufacturer's instructions. Supply and lay one layer of 'Super Sisalation' double sided reflective roof heat insulation sheet including lapping with PPC 493 reinforced aluminium foil tape and secured to roof structure by self-drilling fasteners complete with metal washers and in accordance with the Manufacturers instructions. Supply and lay one layer of 'Super Brite' double sided reflective roof heat insulation sheet including lapping and secured to roof structure by self-drilling fasteners complete with metal washers and in accordance with manufacturer's instructions. Supply and lay "Heisterholz K 21" semi-glazed shale clay roofing tiles laid on and including 50 x 25mm timber batterns with 125mm head laps and 52mm side laps including all necessary fixing accessories. Extra Over "Heisterholz K 21" semi-glazed shale clay roofing tiles for Right/Left verge tiles. Extra Over "Heisterholz K 21" semi-glazed shale clay roofing tiles for Boarding Plate tiles. Supply and lay "Heisterholz K 21" semi-glazed shale clay roofing Ridge/Hip tiles including cement mortar (1:3) packing. m m m m m m m2 9.15 12.35 15.35 18.00 21.60 26.75 8.20 UNIT RATE ($)

28

m2

5.90

29

m2

5.80

30

m2

71.40

31

38.60

32

12.30

33

58.10

CD11/SOR-Building, Sanitary & Plumbing/Roofing & Re-roofing/(3)/[2009 Edition]

ROOFING & RE-ROOFING SOR 4 SCHEDULE OF RATES ROOFING & RE-ROOFING S/N DESCRIPTION UNIT RATE ($)

34

Extra Over "Heisterholz K 21" semi-glazed shale clay roofing Ridge/Hip tiles for Ridge Start/End tile including cement Mortar (1:3) packing. Supply and lay "Ergoldsbacher" plain unglazed coloured roof tiles (straight cut with rounded corners) in double tiling pattern laid on and including 50 x 25mm timber battens complete with all necessary fixing accessories. Supply and lay "Ergoldsbacher" plain unglazed coloured roof ridge tiles no. 16 including cement mortar (1:3) packing. Extra Over "Ergoldsbacher" plain unglazed coloured roof ridge tiles no. 16 for Ridge Start/End tile including cement mortar (1:3) packing. Extra Over "Ergoldsbacher" plain unglazed coloured roof mortar (1:3) packing. RE-ROOFING

no

47.90

35

m2

119.50

36

63.10

37

no

9.60

38

no

225.00

39

Removal of existing waterproofing bituminous membrane to reinforced concrete flat roof including all necessary machinery for hoisting, transportation and disposal off site. Removal of existing precast concrete secondary roof slabs and supports to reinforced concrete flat roof including all necessary machinery for hoisting, transportation and disposal off site. Hacking existing concrete surface to form keys, remove debris from site, wash and clean surfaces to receive new finishing. Apply 1 coat of approved bonding agent to existing reinforced concrete roof slab. 20mm thick cement and sand (1:3) screed rendering to reinforced concrete roof slab trowelled to a smooth finish. Add to (or deduct from) Item 5 for each 5mm thickness over (or under) 20mm. 20mm thick cement and sand (1:3) screed rendering to skirtings, curbs and returns etc and trowelled to a smooth finish including coved and rounded angles for 0 - 150mm girth.

m2

1.95

40

m2

3.00

41

m2 m2 m2 m2

1.40

42

1.70

43

8.90

44

1.50

45

3.90

CD11/SOR-Building, Sanitary & Plumbing/Roofing & Re-roofing/(4)/[2009 Edition]

ROOFING & RE-ROOFING SOR 5 SCHEDULE OF RATES ROOFING & RE-ROOFING S/N 46 DESCRIPTION 20mm thick cement and sand (1:3) screed rendering to skirtings, curbs and returns etc and trowelled to a smooth finish including coved and rounded angles for 151 - 300mm girth. Add to (or deduct from) Item 7 for each 5mm thickness over (or under) 20mm for 0 - 150mm girth. Add to (or deduct from) Item 8 for each 5mm thickness over (or under) 20mm for 151 - 300mm girth. Extra over for approved waterproofing compound incorporated in the cement and sand screed rendering for 20mm thickness. Extra over for approved waterproofing compound incorporated in the cement and sand screed rendering for each 5mm thickness. Removal of existing cement and sand screed rendering, average 25mm thick, to reinforced concrete flat roof including all necessary machinery for hoisting, transportation and disposal off site. Add to (or deduct from) Item 13 for each 5mm thickness over (or under) 25mm. Supply and fix 0.80mm thick x 150mm girth (twice-bent to edge) aluminium expansion joint cover with V shaped groove in the centre including fixing with stainless steel screws and washers at 150mm c/c. Supply and lay 600 x 600 x 30mm thick ferrocement secondary roof slabs, reinforced with galvanised welded fabric to reinforced concrete flat roof including all necessary supporting concrete solid blocks, labour and materials for jointing. Apply a complete Waterproofing Membrane System to reinforced concrete flat roof consisting of 6 coats of waterproofing membranes, complying with SS133:1987 and its latest amendments, 1 layer of open woven glassfibre membrane and 1 coat of bituminous aluminium finishing paint and in accordance with the manufacturers instructions. Apply a complete Panel Roofing System to roof surfaces consisting of 38mm thick waterproofing cement and sand panel (1:3), 50mm thick Styrofoam insulation board or other approved, and 6 coats of waterproofing membranes, 1 layer of open woven glass membrane and a minimum of 20mm thick waterproofing cement and sand screed (1:3) laid to fall and including all necessary labour and materials for jointing (measured flat on plan). UNIT m RATE ($) 5.90

47 48 49 50 51

m m m2 m2 m2

1.00 1.40 2.60 1.00 2.60

52 53

m2 m

0.35 13.90

54

m2

28.45

55

m2

7.80

56

m2

42.00

CD11/SOR-Building, Sanitary & Plumbing/Roofing & Re-roofing/(5)/[2009 Edition]

ROOFING & RE-ROOFING SOR 6 SCHEDULE OF RATES ROOFING & RE-ROOFING S/N 57 DESCRIPTION Removal and disposal of existing panel roofing including cement/sand base screed to reinforced concrete flat roof, including all necessary machinery for hoisting, transportation and disposal off site. Provide and construct hot-dipped galvanised steel angle end thrust support for existing pipe and complete with cast-in-situ concrete supports to reinforced concrete flat roof including all necessary fixing and bolting. Supply and lay 50mm thick rigid extruded polystyrene foam insulation board of density min. 32 kg/m3 to roof surface. Repair Seepage and Leaks Supply labour and materials to rake out mortar joints to an even depth of 25mm. Brush out all loose sand and mortar and fill the groove solid to form a continuous sealant:60 61 62 With approved polyurethane sealant With approved polysulphide sealant Extra over item for filling groove / expansion joints solid with and approved backing rod Supply labour and materials to rake out mortar joints at the interface to a depth of 25mm. Brush out loose sand and mortar and fill the groove with polymer modified mortar. Supply labour and materials to form spray/fillet with approved polymer modified cement mortar or non-shrink grout to the correct gradient including hacking if necessary Supply labour and materials to rack out mortar joints between bricks and repointing with polymer modified cement mortar (based on area of brick wall) Apply 2 coats of clear elastomeric waterproof membrane including patching hairline cracks on brick wall with brick colour cement if necessary Apply 2 coats of approved silane/siloxane based water penetrant including patching hairline cracks on brick wall with brick colour cement if necessary m m m 9.70 10.50 1.50 UNIT m2 RATE ($) 6.15

58

no

40.55

59

m2

13.95

63

4.70

64

5.70

65

m2

13.60

66

m2

6.40

67

m2

9.20

CD11/SOR-Building, Sanitary & Plumbing/Roofing & Re-roofing/(6)/[2009 Edition]

ROOFING & RE-ROOFING SOR 7 SCHEDULE OF RATES ROOFING & RE-ROOFING S/N 68 DESCRIPTION Supply labour and materials to repair the plastered wall panels by applying two coats of approved proprietary plaster such as Ventonite, Esai-Plaster and Ready-Cote etc, including hacking, painting to the repaired surface Repair to cracks by hacking U groove on the cracks to 25mm width x 20mm depth. Brush out all loose sand and motor and fill the groove with polymer modified mortar including painting to the repaired surface. Repair to cracks by hacking V groove on the cracks and patch including painting to the repaired surface:70 71 72 With approved polyurethane sealant With approved polysulphide sealant Supply labour and material to repair the hollow and bulging plaster with polymer modified mortar and skimming proprietary material including hacking and painting to the repaired surface Installation of special wall tie to existing brickwall including galvanized mesh sleeve, approved resin, stainless steel wall tie Hack off all existing plastering to walls and prepare surface to receive new finish including removal of debris Hack existing plastered or concrete wall surface to form random keys, clean and wash to receive new finish including removal of debris Spatterdash of cement slurry on existing surface to form keys m m m2 14.70 18.10 27.20 UNIT m2 RATE ($) 18.70

69

7.30

73

no m2 m2

9.10

74

2.90

75

2.10

76

m2

1.00

CD11/SOR-Building, Sanitary & Plumbing/Roofing & Re-roofing/(7)/[2009 Edition]