SAUDI ARABIAN STANDARD SASO 2663/2017
AIR CONDITIONERS
MINIMUM ENERGY PERFORMANCE, LABELLING AND TESTING
REQUIREMENTS FOR LOW CAPACITY WINDOW TYPE AND
SINGLE-SPLIT
2
SAUDI ARABIAN STANDARD SASO 2663/2017
1. SCOPE ............................................................................................................................................................... 5
2. NORMATIVE REFERENCES ........................................................................................................................ 5
3. TERMS AND DEFINITIONS ........................................................................................................................... 6
4. MINIMUM ENERGY PERFORMANCE STANDARD (MEPS) .................................................................. 8
4.1 General ........................................................................................................................................................ 8
4.2 Declaration of the rated cooling capacity and heating capacity .......................................................... 9
4.3 Declaration of the rated EER (EERrated) and rated COP (COPrated) .................................................... 9
4.4 Functional requirements related to cooling performances ................................................................... 9
4.5 Heating performances for AC with heating and cooling function ........................................................ 9
4.5.1 General ..................................................................................................................................................... 9
4.5.2 Heating capacity ...................................................................................................................................... 9
4.5.3 Functional performance of the heating function ............................................................................... 10
5. CRITERIA FOR ACCEPTABILITY OF PRODUCTS AT REGISTRATION ........................................... 10
5.1 General ...................................................................................................................................................... 10
5.2 Information about registration of the air-conditioner ........................................................................... 10
5.3 Product using test report to justify the performance ........................................................................... 10
5.3.1 General ............................................................................................................................................... 10
5.3.2. Conditions for the test report .......................................................................................................... 10
5.3.3. Criteria for acceptability .................................................................................................................. 11
6. CRITERIA FOR MARKET SURVEILLANCE ............................................................................................. 11
7. NAME PLATE AND INSTRUCTION SHEET OR MANUAL ......................................................................... 11
7.1 General ...................................................................................................................................................... 11
7.2 Information on the nameplate................................................................................................................. 12
7.3 Instruction sheet ....................................................................................................................................... 12
8. ENERGY RATING CLASSIFICATION ........................................................................................................ 13
8.1 General ...................................................................................................................................................... 13
8.2 Determination of the energy efficiency class ....................................................................................... 13
9. ENERGY LABELLING REQUIREMENTS ..................................................................................................... 13
9.1 Information and Values Contained in the Energy Labels ....................................................................... 13
9.2 Design and placement of the label ........................................................................................................... 14
10. REGISTRATION REQUIREMENTS ......................................................................................................... 17
3
SAUDI ARABIAN STANDARD SASO 2663/2017
This document has been prepared by the Saudi Standards, Metrology and Quality Organization
(SASO) and will supersede the previous standard: SASO 2663:2014 "Energy Labelling and Minimum
Energy Performance Requirements for Air-Conditioners". The standard was updated in order to:
The objective of this document is to provide detailed performance and energy labelling
requirements that air-conditioning appliances need to meet in order to enter the Saudi market.
4
SAUDI ARABIAN STANDARD SASO 2663/2017
1. SCOPE
This standard specifies the Minimum Energy Performance Standard (MEPS) and the energy labelling
requirements for single-package of window type, single split-system non-ducted air conditioners using
air-cooled condensers, single split-system ducted air-conditioners using air-cooled condensers, and
heat pumps using air-cooled condensers or using electric resistance for residential, commercial and
industrial sector as applicable in accordance with SASO standards.
The standard applies to units designed to operate with the following voltages:
The standard covers units with capacities up to and including 65,000 Btu/h (19 kW).
Note: For any additional requirements such as safety, please refer to SASO related standards.
The following units are excluded from the scope of this standard:
a) Units covered by SASO 2874 : 2016 ‘’Air Conditioners – Minimum Energy Performance
Requirements and Testing Requirements’’ standard
b) Evaporative coolers
c) Mobile (windowless) and portable units with exhaust air duct
d) Individual assemblies not constituting a complete refrigeration system such as condensing
units for separate use
e) Models that have been granted exemption by SASO due to specific design for applications
such as air-conditioners that are not intended for human comfort
2. NORMATIVE REFERENCES
The following normative reference standards apply. However, this standard supersedes the below
reference standards in case of conflicting requirements. For dated references, only the edition cited
applies. For undated references, the latest edition of the referenced document (including any
amendments) applies.
SASO GSO ISO 5151 (2010): Non-ducted air conditioners and heat pumps — Testing and
rating for performance
SASO GSO ISO 13253 (2011): Ducted air-conditioners and air to air heat pumps – Testing
and rating for performance
5
SAUDI ARABIAN STANDARD SASO 2663/2017
6
SAUDI ARABIAN STANDARD SASO 2663/2017
7
SAUDI ARABIAN STANDARD SASO 2663/2017
Air conditioner Rated Cooling Capacity (CC) categories at EER Values (Btu/h)/W
appliance type test condition (T1) in Btu/h (or W)
T1 T3
Single package of
Window type – CC ≤ 24,000 (7,050W) 9.80 7.00
category A
Single package of
24,000 (7,050W) < CC
Window type – 9.00 6.20
category B ≤ 65,000 (19,050 W)
8
SAUDI ARABIAN STANDARD SASO 2663/2017
The declaration of the rated heating capacity CHrated shall be expressed (when relevant) in terms of W
at a multiple of 50 W.
4.3 Declaration of the rated EER (EERrated) and rated COP (COPrated)
Standard values of energy efficiency, whenever published, shall be expressed in multiples of the
nearest 0.05 Btu/(W.h) for the rated EER or 0.05 (W/W) for the rated COP.
- Minimum cooling, freeze-up air blockage and freeze-up drip when relevant
As expressed in SASO GSO ISO 5151 Clause 5.2 to 5.5 or SASO GSO ISO 13253 Clause 6.2 to 6.4.
4.5.1 General
These performances shall be stated only if the heating mode is available.
For air conditioners powered with an electric resistance for the heating mode, cooling and heating
modes shall not operate simultaneously, and the maximum power shall be declared by the
manufacturer.
Note: refer to clause 9 to express the heating information in the energy label.
9
SAUDI ARABIAN STANDARD SASO 2663/2017
The information about registration requirement for energy labelling and MEPS is available in
information center of Saudi Standards, Metrology and Quality Organization (SASO).
An application shall be provided for each model, in accordance with Appendix A, and submitted to the
registration body (see Clause 10).
The test procedure shall correspond to the type of product and relevant testing standard (see Clause 2).
Information about main components (compressor, heat exchanger, motors, blowers, ….) to clearly
identify the model tested and submitted for the application shall be presented.
10
SAUDI ARABIAN STANDARD SASO 2663/2017
Any information related energy performance added showed in any part of the air-
conditioner unit or packaging shall not have any ambiguity or lead to misunderstanding of the perform
ance of the unit.
11
SAUDI ARABIAN STANDARD SASO 2663/2017
Rated current in A.
Rated Input power rating in W or kW.
Rated Heating capacity in W or kW.
Rated Coefficient of Performance (COP) (W/W).
– Refrigerant used and mass of refrigerant charge in kg.
12
SAUDI ARABIAN STANDARD SASO 2663/2017
13
SAUDI ARABIAN STANDARD SASO 2663/2017
Field (h): This field identifies the registration number, the label serial number, and the
standard reference number.
Field (i): This field identifies the legal statement.
In case of Split type Air Conditioners, a label shall be fixed and non-removable on both the indoor and
outdoor units and their packaging.
The label must be 100 mm wide and 170 mm high; if the label shall be printed in a larger format its
contents must remain proportionate.
14
SAUDI AR
RABIAN STA
ANDARD SASO 26663/2017
15
SAUDI AR
RABIAN STA
ANDARD SASO 26663/2017
on of inform
Figure 2 – Positio mation on tthe label
(a)
(b)
((c)
((d)
(e) (gg)
(f)
(i)
(h)
16
SAUDI ARABIAN STANDARD SASO 2663/2017
Applications shall be submitted through the registration system electronically via SASO website. The
applicant shall fulfill all updated requirements of the electronic registration system and any new
requirements, procedures, and regulations required by SASO. A draft of the registration form is
provided in Annex (the final version is the one presented on the SASO website).
17
SAUDI ARABIAN STANDARD SASO 2663/2017
APPENDIX A
APPLICATION FOR REGISTRATION OF
AIR-CONDITIONERS FOR ENERGY LABELLING AND MEPS (informative)
This Appendix presents out the format for submitting an application for registration.
I hereby apply for registration of an electrical appliance/s for the purpose of energy labelling
In the Country of ................... (specify the country in which this application is made)
Contact Person : (Name and Adress and workplace in each sales country)
JobTitle : ……………………………………
1
2
3
18
SAUDI ARABIAN STANDARD SASO 2663/2017
Fan type…………………………………………………..
3- Heat exchanger
Volume and description of the heat exchanger ………….
4- Electric motor efficiency class……………………………
20
SAUDI ARABIAN STANDARD SASO 2663/2017
21
SAUDI ARABIAN STANDARD SASO 2663/2017
PART 5 – PERFORMANCES
ENERGY PERFORMANCE – COOLING – CONDITION T1
COOLING POWER at T1 Rated Effective Power Input
(kW)
Tested Effective Power Input
(kW)
COOLING CAPACITY at T1 Rated Cooling Capacity (Btu/h
and kW)
Tested Cooling Capacity (Btu/h
and kW)
EER at T1 Rated EER (Btu/(h.W))
Tested EER (Btu/(h.W))
Class rating according to Clause 8 ……class (please specify)
ENERGY PERFORMANCE – COOLING – CONDITION T3
COOLING POWER at T3 Rated Effective Power Input
(kW)
Tested Cooling Power Input
(kW)
COOLING CAPACITY at T3 Rated Cooling Capacity (Btu/h
and kW)
Tested Cooling Capacity (Btu/h
and kW)
EER at T3 Rated EER (Btu/(h.W))
Tested EER (Btu/(h.W))
FUNCTIONAL PERFORMANCE – COOLING
Operability at Maximum cooling conditions at Tested Result: Pass or Fail
T3 conditions
Declared
Minimum cooling at T3 conditions Tested Result: Pass or Fail
Declared
Freeze-up drip at T3 conditions (non-ducted Tested Result: Pass or Fail
AC)
Declared
Condensate control and enclosure sweat Tested Result: Pass or Fail
performance Declared
ENERGY PERFORMANCE – HEATING – CONDITION H1 – when relevant
HEATING POWER at H1 Rated Effective Power Input
(kW)
Tested Effective Power Input
(kW)
HEATING CAPACITY at H1 Rated Heating Capacity (kW)
Tested Heating Capacity (kW)
COP at H1 Rated COP (W/W)
22
SAUDI ARABIAN STANDARD SASO 2663/2017