#5067O
CHLORIDE (1 drop = 10 ppm)
COMPONENTS: 3. Add 5 drops R-0630 Chromate Indicator. Swirl to mix. Sample will turn yellow
1 x 5067O Instruction (Fig. 2).
1 x 9198O Sample Tube, Graduated (25 mL) w/ cap & orange dot, plastic
1 x R-0630-C Chromate Indicator, 2 oz, DB
1 x R-0638O-A Phenolphthalein Indicator, .75 oz w/ orange cap, DB 4. Add R-0706 Silver Nitrate Reagent dropwise, swirling and counting after each
1 x R-0687O-C Sulfuric Acid .12N, 2 oz w/ orange cap, DB drop, until color changes from yellow to milky salmon (brick red) (Fig. 3).
1 x R-0706-C Silver Nitrate Reagent, 2 oz, DB
NOTE: A white precipitate will form as R-0706 Silver Nitrate Reagent is added to
TO ORDER REPLACEMENT PARTS AND REAGENTS CALL TOLL-FREE the sample. Do not add enough R-0706 Silver Nitrate Reagent to give a
800-TEST KIT (800-837-8548). brown color. First change from yellow to a milky salmon (brick red) is the Fig. 1
endpoint.
PROCEDURE:
CAREFULLY READ AND FOLLOW PRECAUTIONS ON REAGENT LABELS.
KEEP REAGENTS AWAY FROM CHILDREN. 5. Multiply drops of R-0706 Silver Nitrate Reagent by 10. Record as parts per
million (ppm) chloride (Cl-).
NOTE: When dispensing reagents from dropper bottles, always hold bottle in a
vertical position.
Chloride Test
NOTE: When sulfite content of sample water to be tested exceeds 10 ppm, the
sulfite should be oxidized to prevent interference in test. A 25 mL water
sample is first adjusted to the appropriate pH, then 1 mL (or 25 drops) Fig. 2
of R-0649 Hydrogen Peroxide Solution (sold separately) is added and
thoroughly mixed. Continue with the rest of the procedure.
1. Rinse and fill 25 mL sample tube (#9198O) to 25 mL mark with water to be tested.