0% found this document useful (0 votes)
51 views4 pages

METRAmax 2

The METRAmax 2 is a 3-sentence analog multimeter for use in schools and vocational training. It measures voltage from 100mV to 300V, current from 100uA to 3A, and has automatic battery shutdown after 45 minutes. The rugged housing protects the meter from mechanical stress, and safety features include fusible links and inverse parallel diodes to protect against overload.

Uploaded by

Jose Rivera
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
51 views4 pages

METRAmax 2

The METRAmax 2 is a 3-sentence analog multimeter for use in schools and vocational training. It measures voltage from 100mV to 300V, current from 100uA to 3A, and has automatic battery shutdown after 45 minutes. The rugged housing protects the meter from mechanical stress, and safety features include fusible links and inverse parallel diodes to protect against overload.

Uploaded by

Jose Rivera
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

METRAmax 2

Analog Multimeter
3-348-792-03
4/6.16

• Voltage measurement:
0...100/300 mV/1 V=; 0...3 /10 /30 /100 /300 V=/∼
• Current measurement:
0...100 μA/1/10/100 mA/1 /3 A =/∼
• Zero point: selectable on the left or at mid-scale
• Accuracy: Class 2 =/3 ∼

Range of Applications Rugged housing design


The rugged plastic housing and the spring-loaded bearing jewels
• Schools of the moving-coil mechanism protect the meter against damage
• Vocational schools in the case of mechanical stress. The protective rubber cover and
• Craft shops the carrying pouch offer special protection under adverse operat-
ing conditions. Both are available as accessories.
The handheld multimeter METRAmax 2 was developed in coop-
eration with a renowned German manufacturer of educational
Special technical qualities
systems and thus meets the actual demands set in teaching and
vocational training. • „Galvanometer operation“
Thanks to its excellent overload capacity, optional zero setting due to „left“ zero position of the pointer, switchable to „mid-
either at mid-scale or left as well as automatic battery shutdown, scale“
the meter is not only suited for students’ exercises but also for • High, constant input impedance
balancing tasks and service applications. during voltage measurement due to electronic amplifier
• Automatic battery shutdown after 45 minutes
• Expansion of the current measuring range to 10 A
Features by means of accessory shunt

Safe handling
The connection sockets and connection plugs of the measure- Applicable Standards and Regulations
ment cables, which are available as accessory equipment, are
protected against accidental contact. IEC 61010-1/ Safety requirements for electrical equipment for
DIN EN 61010-1/ measurement, control and laboratory use
Range selector switch VDE 0411-1 – General requirements
All measuring ranges and measuring functions can be conve- DIN EN 60529 Test instruments and test methods
niently selected with a clear, central rotary switch. DIN VDE 0470-1 – Degrees of protection provided by enclosures (IP code)
DIN EN 61326-1 Electrical equipment for measurement, control and laboratory
VDE 0843-20-1 use – EMC requirements – Part 1: General requirements

GMC-I Messtechnik GmbH


METRAmax 2
Analog Multimeter

Characteristic Values Power Supply


Measuring ranges Battery 9 V flat cell battery
IEC 6 L R61 (IEC 6 F 22)
Direct and Internal resistance Direct and Voltage drop automatic battery shutdown after 45 min.
alternating voltage alternating current
100 mV 10 MΩ 100 μA / 55 mV
300 mV 10 MΩ 1 mA / 55 mV Overload Protection
1 V 10 MΩ 10 mA / 55 mV
3V / 10 MΩ 1 MΩ 100 mA / 55 mV Fusible link F 3,15 H/250 V according to
10 V / 10 MΩ 1 MΩ 1 A / 53 mV
DIN VDE 0820 part 22/EN 60127-2
protects the current measuring circuits in
30 V / 10 MΩ 1 MΩ 3 A / 51 mV the case of overload.
100 V / 10 MΩ 1 MΩ The measurement mechanism is protected
300 V / 10 MΩ 1 MΩ by two diodes with inverse-parallel
connection.
Influence quantities and nominal ranges of use
Temperature in the
range of 0 ... +40 ºC ±2%/10 K at Electrical Safety
Frequency for all
measuring ranges ±2.5 % in the range of 30 Hz ... 1.5 kHz Safety class II per IEC 61010-1/DIN EN 61010-1/
±5 % in the range of 1.5 kHz ... 3 kHz VDE 0411-1
Measuring category 300 V CAT III
Nominal voltage 300 V
Display Contamination degree 2
Test voltage 3.7 kV∼
Mechanism Moving-coil mechanism with core magnet
Scale mirror-backed
Scale length black scale: Electromagnetic Compatibility EMC
87 mm in the range of V, A, 0 ... 3/10
red scale: 62 mm Interference emission EN 610326-1:2006 class B
in the range of V, A, -10/-3 ... 0 ... +3/+10 Interference immunity EN 610326-1:2006
EN 610326-2-1:2006

Accuracy at Reference Conditions


Mechanical Design
Class 2 for direct current
Class 3 for alternating current Protection Housing IP 50, Terminals IP 20

Extract from table on the meaning of IP


codes
Reference Conditions IP XY Protection against IP XY Protection against the
(1st digit X) foreign object entry (2nd digit Y) penetration of water
Ambient temperature + 23 °C ±2 K
0 not protected 0 not protected
Position of use horizontal
1 ≥ 50.0 mm dia. 1 vertically falling drops
Frequency 50 ... 60 Hz
vertically falling drops with
2 ≥ 12.5 mm dia. 2
enclosure tilted 15°
Waveshape and its evaluation 3 ≥ 2.5 mm dia. 3 spraying water
A sinosoidal waveshape is used as the basis for the measurement 4 ≥ 1.0 mm dia. 4 splashing water
of alternating quantities. The meters feature one-way rectification, 5 dust protected 5 water jets
are calibrated in RMS values and evaluate the arithmetic mean 6 dust-tight 6 powerful water jets
value.

Dimensions 100 x 140 x 35 mm


Weight approx. 0.3 kg
Ambient Conditions
Storage temperatures –25 ... 65 °C (without battery)
Relative humidity max. 75%, no condensation allowed Standard Equipment
1 multimeter (without cable set)
1 battery
1 operating instructions

2 GMC-I Messtechnik GmbH


METRAmax 2
Analog Multimeter

Accessories
Carrying pouch F841 Protective rubber cover GH19

Protective rubber cover as viewed Protective rubber cover as viewed


from the top from the bottom
Opening at the bottom for with guide rails for fastening the test
mechanical zero point setting probes

Cable set KS 17-ONE Cable set KS 17-2


Dimensional drawing
of the carrying pouch

GMC-I Messtechnik GmbH 3


METRAmax 2
Analog Multimeter

Order Information
Description Type Article Number
Hand-held analog multimeter METRAmax 2 M102A
Carrying pouch F841 Z104A
Protective rubber cover GH19 Z104B
Cable set (1 pair of measurement
cables) 1.2 m, with VDE-GS symbol
600 V CAT III 1 A1),
600 V CAT II 16 A2) KS17-ONE Z110K
Cable set (1 pair of measurement
cables) 1.2 m, with VDE-GS symbol
1000 V CAT III 1 A1),
600 V CAT IV 1 A1),
1000 V CAT II 16 A2) KS17-2 GTY3620034P0002
1)
with safety cap applied
2) without safety cap applied

For additional information concerning accessories please refer to


• the catalog „Measuring Instruments and Testers“
• our website www.gossenmetrawatt.com

Edited in Germany • Subject to change without notice • A pdf version is available on the internet

Phone +49 911 8602-111


GMC-I Messtechnik GmbH Fax +49 911 8602-777
Südwestpark 15 E-Mail [email protected]
90449 Nürnberg • Germany www.gossenmetrawatt.com