Q&T Open Channel Flow Meter Catalog
Q&T Open Channel Flow Meter Catalog
Flow Meter
Overview
It consists of two parts, the ultrasonic level sensor and wall mounted flow
monitor/controller. The ultrasonic level sensor uses the sound wave
reflection principle to detect the liquid level in the weir, and then the
microprocessor calculates the corresponding flow value
automatically using the related formula and characteristics of the channel.
Advantage
01 02 03
Non-contact measurement, High level detection accuracy. The accuracy of change Adapt to a variety of
long service life and simple in level is 1mm. For every 1mm change in the liquid weirs/flumes and simple
maintenance. level, the open channel flow rate changes accordingly. setup for Parshall flumes,
So the flow measurement is more accurate. triangular weirs
(30* /45*/60* /90°/120* )
and rectangular weirs etc.
04 05 06 07
Large screen with Simple programming Excellent anti-interference Rugged IP67 powder
backlight LCD display. and easy operation. capability, low blind area coated aluminum
Displays flow rate in A hand operator is and high sensitivity; The enclosure, Sensor
L/S or M3/h available for easy cable length between protection class IP68.
operation. (If you need) sensor and transmitter
up to 1000m.
08 09 10 11
Chemically resistant Provided Provided 4-20mA Customize solar power supply. Available
probe materials for programmable output and RS485 at remote and non-powered site
maximum application 6 relays at most for serial communication applications. Low power consumption,
flexibility; alarms; (Modbus RTU) . customer can choose optional 12V
operating voltage Transmitter, power
consumption only 2 watts.
01
Ultrasonic Open Channel Flow Meter
Q&T Instrument Co.,Ltd
Application
This PLCM ultrasonic open channel flow meter with a primary device (such as a flume or weir) are a cost effective
solution for managing varying flow rates in unpressurized systems. Typical applications are as below:
Measuring Principle
Using ultrasonic level technology, Open channel flow meters include a non-contacting sensor mounted above
the flume or weir. By measuring the time from transmission of an ultrasonic pulse to receipt of an echo, the
water level or “Head” is accurately measured.
As the electronic flow transmitter knows the installation height H from parameters setting, it can calculate the
level as follows: h = H – d .
Since the speed of sound through air is affected by changes in temperature, the PLCM O.C.M. has integrated
a temperature senor to improve accuracy.
For determined flumes, there is a fixed functional relationship between the instantaneous flow and liquid
level. The formula is Q=h (x). Q means instantaneous flow, h means liquid level in flumes. So the electronic
flow transmitter can calculate the flow rate through determined flumes and the level value.
02
Ultrasonic Open Channel Flow Meter
Q&T Instrument Co.,Ltd
THE
PROBE
BLANK ING
DISTANCE
H SIGN:
H: Installation height
d: Empty value
h h: Level
h=H-d
Blind Zone: The ultrasonic sensor cannot detect echoes at the same time when transmitting ultrasonic waves.
When the probe is very close to the liquid surface, the emitted wave and the echo will overlap and cannot be
distinguished. Within this area there is no explicit/ reliable measurement possible. This is blind zone (Blanking
distance).
During installation, the probe should be a certain distance higher than the maximum liquid level to prevent the liquid
level from entering the blind zone.
Technical Data
03
Ultrasonic Open Channel Flow Meter
Q&T Instrument Co.,Ltd
Resolution 1mm
Dimensions 248H*184W*122D(mm)
Sensors Specification
04
Ultrasonic Open Channel Flow Meter
Q&T Instrument Co.,Ltd
Operation
The open channel flowmeter is used together with various types of weirs/flumes to measure or monitor the total
amount of water. The QTCM meter includes a selection of primary devices with preprogrammed tables to simplify
the setup, including:
● Parshall flumes
● Rectangular Weirs
● V-notch Weirs
0.3m
0.5m~1m 0.5m~1m
05
Ultrasonic Open Channel Flow Meter
Q&T Instrument Co.,Ltd
LCD shown
Remote Control
Keys
Terminal
Wiring
Depending on the power supply and signal output function, the wiring diagram of the instrument is different.
When the MODBUS communication function is provide, the terminal Relay 6 is used for RS485 output.
06
Ultrasonic Open Channel Flow Meter
Q&T Instrument Co.,Ltd
N L
AC85-265V
POWER
The Cable
07
Ultrasonic Open Channel Flow Meter
Q&T Instrument Co.,Ltd
Mounting Dimensions
08
Ultrasonic Open Channel Flow Meter
Q&T Instrument Co.,Ltd
QTCM X X X X X X X X X
DC 24V 0.2 A D
AC 85~265V 0.1A A
ABS/(-40-75)℃/IP68 A
Sensor Material
/Process
Temperature PVC/(-40-75)℃/IP68 B
/Protection Class
PTFE/(-40-75)℃/IP68 C
Thread G
Process Connection
/Material
Flange /PP D
Housing Material
Aluminum / IP67 L
/ Protection Class
M20*1.5 M
Cable Entry
1/2"NPT N
10 m (standard) L10
Cable Length
X cable length (Up to 1000m) LX
09
Q&T Instrument Co.,Ltd