0% found this document useful (0 votes)
42 views5 pages

DRDN40: 40A DIN Rail Type Redundancy Module

This document provides information about the DRDN40 40A DIN Rail redundancy module. It has features like supporting 1+1 and N+1 redundancy systems, two input channels and one output, and is suitable for redundancy operation of 12V/24V/48V systems. It can improve overall system reliability when used with a power supply. The module has a wide operating temperature range of -40 to +80°C and narrow width of 55mm.

Uploaded by

Rachid JKINI
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
42 views5 pages

DRDN40: 40A DIN Rail Type Redundancy Module

This document provides information about the DRDN40 40A DIN Rail redundancy module. It has features like supporting 1+1 and N+1 redundancy systems, two input channels and one output, and is suitable for redundancy operation of 12V/24V/48V systems. It can improve overall system reliability when used with a power supply. The module has a wide operating temperature range of -40 to +80°C and narrow width of 55mm.

Uploaded by

Rachid JKINI
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

40A DIN Rail Type Redundancy Module DRDN40

User’s Manual Video



UL62368-1 IEC62368-1 TPTC004

■  ■ 
‧ ‧
‧ ‧
‧ ‧
‧ ‧
‧
‧ >
‧
■ 
‧  
‧

■ 







■ 
 




File Name:DRDN40-SPEC 2022-03-18


40A DIN Rail Type Redundancy Module DRDN40
SPECIFICATION
DRDN40-
MODEL
=12V, 24V, 48V
NUMBER OF INPUT 2 Channels
DC NORMAL VOLTAGE 12Vdc 24Vdc 48Vdc
DC VOLTAGE RANGE 9~14Vdc 19~29Vdc 36~60Vdc
RATED CURRENT 0~40A per input Continuous
INPUT
VOLTAGE DROP (Vin-Vout) (max.) 0.3V
PEAK CURRENT 0~60A per input 5Sec.
EFFICIENCY (Typ.) 98%
INPUT REVERSE CURRENT (max.) 1mA
INPUT REVERSE VOLTAGE (max.) 40Vdc 40Vdc 65Vdc
RATED CURRENT 0~40A, Continuous
PEAK CURRENT (max.) 60A, 5Sec.
OUTPUT
CAPACITANCE(Typ.) 320uF
STANDBY POWER LOSSES(Typ.) 1.5W
OVERLOAD <60A,5Sec. No damage
PROTECTION
SHORT CIRCUIT <60A,5Sec. No damage
REDUNDANCY For 1+1 redundancy ,and support N+1 redundancy
BOTH INPUTS VOLTAGE ALARM <8.5Vor>14.7V(±5%) <18Vor>31V(±5%) <34.2Vor>63V(±5%)
FUNCTION RELAY 30Vdc/1A resistive load
LED STATUS DISPLAY Green LED OK
COOLING Free air convection
WORKING TEMP. Note.2 -40 ~ +80℃ (Refer to "Derating Curve")
WORKING HUMIDITY 5 ~ 95% RH non-condensing
STORAGE TEMP. -40 ~ +85℃
ENVIRONMENT
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 60℃)
VIBRATION Component:10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC61373
OPERATING ALTITUDE Note.3 5000 meters/OVC II
SAFETY STANDARDS IEC62368-1, UL62368-1, EAC TP TC 004 approved
WITHSTAND VOLTAGE IP/OP - Chassis : 0.5KVac ; IP/OP- Relay : 0.5KVac ; Relay - Chassis : 0.5KVac
ISOLATION RESISTANCE IP/OP - Chassis, IP/OP- Relay, Relay - Chassis:>100M Ohms / 500Vdc / 25℃/ 70% RH
Parameter Standard Test Level / Note
Conducted BS EN/EN55032(CISPR32) Class B
EMC EMISSION Radiated BS EN/EN55032(CISPR32) Class B
SAFETY & Voltage Flicker ----- -----
EMC Harmonic Current ----- -----
(Note.4)
BS EN/EN55035, BS EN/EN61000-6-2(BS EN/EN50082-2), BS EN/EN55024
Parameter Standard Test Level / Note
ESD BS EN/EN61000-4-2 Level 4, 15KV air ; Level 3, 8KV contact; criteria A
Radiated BS EN/EN61000-4-3 Level 3, 10V/m ; criteria A
EFT / Burst BS EN/EN61000-4-4 Level 3, 2KV ; criteria A
EMC IMMUNITY
Surge BS EN/EN61000-4-5 Level 3, 1KV/Line-Line ;Level 3, 2KV/Line-Line-Chassis ;criteria A
Conducted BS EN/EN61000-4-6 Level 3, 10V ; criteria A
Magnetic Field BS EN/EN61000-4-8 Level 4, 30A/m ; criteria A
MTBF 1672.9K hrs min. Telcordia SR-332 (Bellcore) ; 499.5K hrs min. MIL-HDBK-217F (25℃)
OTHERS DIMENSION 55*125.2*100mm (W*H*D)
PACKING 0.5Kg;20psc/11Kg/1.49CUFT
℃

℃℃

NOTE


(as available on http://www.meanwell.com)
※:https://www.meanwell.com/serviceDisclaimer.aspx

File Name:DRDN40-SPEC 2022-03-18


40A DIN Rail Type Redundancy Module DRDN40
Block Diagram
Alarm1 DC OK

control

{ {
+ +
Vin 1

V in - - V out
Vin 2

+ +
control
-
FG

Alarm2 DC OK

DC OK Relay Contact

Contact Ratings (max.) 30V/1A resistive load


Contact Close(DC OK) PSU turns on
Contact Open(DC Fail) PSU turns off / over or under input voltage

Derating Curve Output Derating VS Input Voltage

100 100
90
80
LOAD (%)
LOAD (%)

70
60
50
40 40
30
20
10

-40 -30 -20 -10 0 10 20 40 50 60 70 80 9 12 14


(VERTICAL) 19 24 29
AMBIENT TEMPERATURE (℃) 36 48 60
INPUT VOLTAGE (V)

File Name:DRDN40-SPEC 2022-03-18


40A DIN Rail Type Redundancy Module DRDN40
Typical Application Notes

1. 1+1 Redundancy:
Using 1 more PSU as the redundant unit

AC-DC AC-DC
Power Power
Supply Supply
1 2
40A 40A

Vin 1 Vin 2

DRDN40

Vout 40A
+ -
Load

2. 1+N Redundancy:
Using more PSUs as the redundant units to increase the reliability
AC-DC AC-DC AC-DC AC-DC AC-DC AC-DC
Power Power Power Power Power Power
Supply Supply Supply Supply Supply Supply
1 2 1 2 1 2
40A 40A 40A 40A .............. 40A 40A

Vin 1 Vin 2 Vin1 Vin2 Vin 1 Vin 2

DRDN40 DRDN40 DRDN40

Vout 40A Vout 40A Vout 40A

+ -
Load

3. Single Use:
Connecting only one PSU to one DRDN40 to reduce the stress of the MOSFET and hence increase the reliability
AC- DC AC- DC
Power Power
Supply Supply
40A 40A

Vin 1 Vin 2 Vin 1 Vin 2

DRDN40 DRDN40

Vout 40A Vout 40A

+ -
Load

File Name:DRDN40-SPEC 2022-03-18


40A DIN Rail Type Redundancy Module DRDN40
Mechanical Specification
Case No.923E Unit:mm

Terminal Pin No. Assignment (TB1,TB2,TB3)


Pin No. Assignment
1,2 Alarm1 DC OK
3,4 Alarm2 DC OK
5 FG
6 DC output +V out
7 DC output -V out
Top View

100 55
5 6 7 1 2
TB1
TB3
TB2
34

LED1
LED2
125.2

1 2 3 4
TB4

Side View Side View


Front View

Terminal Pin No. Assignment (TB4)


Pin No. Assignment
1 DC input +V in1
2 DC input -V in1
3 DC input +V in2
4 DC input -V in2

Bottom View

Installation Instruction

This series fits DIN rail TS35/7.5 or TS35/15.


For installation details, please refer to the Instruction manual.
35

ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15


(For reference only. Not included with unit.)

Back View

Installation Manual
Please refer to : http://www.meanwell.com/manual.html

File Name:DRDN40-SPEC 2022-03-18

You might also like