Photoelectric Smoke Sensors MIX-4010 / MIX-4010-ISO: Features

The document describes the MIX-4010/MIX-4010-ISO photoelectric smoke detector. It has multiple sensitivity settings, connects to the MGC control panel using digital protocol, and can connect up to 240 devices on a single loop. It provides early warning of fires with 360 degree LED visibility and has options for isolated or non-isolated models.

Uploaded by

jelson paul
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
196 views2 pages

Photoelectric Smoke Sensors MIX-4010 / MIX-4010-ISO: Features

The document describes the MIX-4010/MIX-4010-ISO photoelectric smoke detector. It has multiple sensitivity settings, connects to the MGC control panel using digital protocol, and can connect up to 240 devices on a single loop. It provides early warning of fires with 360 degree LED visibility and has options for isolated or non-isolated models.

Uploaded by

jelson paul
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

PHOTOELECTRIC SMOKE SENSORS

MIX-4010 / MIX-4010-ISO

Features
• Any combination of MIX-4000 series devices up to 240
can be connected on a single SLC.
• Different LED colors for Alarms and Troubles.
• Detection of smoke using advanced software algorithms.
• Protection against nuisance alarms caused by dust,
insects or other debris.
• Multiple sensitivity settings.
• Compatible with the full series of MIX-4000 input and
control modules.
• The device can be secured by a unique Anti-Tamper
feature.
• Address is set with the hand-held device programmer
MIX-4010 / MIX-4010-ISO (MIX-4090)
• MODEL OPTION - Built-In short-circuit isolator
(MIX-4010-ISO)

Description Benefits
The MIX-4010/MIX-4010-ISO smoke detector is a hardwired • Open style mounting bases offer easy wiring and low
sensor that continuously monitors the environment to provide pressure locking.
early warning of a fire condition and communicates with the
panel using a fully digital protocol.
• 4” or 6” base options available.
The MIX-4010/MIX-4010-ISO works with an MGC compatible • Remote output can be controlled by the panel.
control panel supporting high rates of information exchange • MIX-4010-ISO is equipped with a bi-directional short-
with reliable and secure bi-directional communication. circuit isolator to protect against wiring faults and loop
The detector is addressed and programmed using the failure.
MIX-4090 hand-held device. Addresses can be selected from
• Low standby current.
a range of 1 -240.
This detector ships with a dust cover to protect the device • Base has detachable tab for labeling device address.
during installation and prior to commissioning. • Leverages interrupts to quickly report alarm conditions to
Two tri-color LEDs on the device provide 360 degrees of fire alarm control panels.
status visibility. • Magnet test option helps with commissioning and
A remote LED indicator can be wired directly to the sensor. maintenance.

CATALOG NUMBER

9501
NOT TO BE USED FOR INSTALLATION PURPOSES.
THIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND
NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY.
Specifications
Normal Operating Voltage 15 to 30VDC Detector LED colors Description
Maximum Alarm Current 3.2mA (LED on) RED (Steady on) ALARM condition
Standby Current 160μA GREEN (Flash) NORMAL condition
Temperature Range 32ºF to 100ºF (0ºC to 37.8ºC) AMBER (Steady on) FAULT condition
Humidity 10% to 93% Non-condensing Sensitivity Level Typical Note
Wiring range on terminals 22 to 12 AWG LEVEL 1 1.75%/FEET Most Sensitive level
Diameter 4.25" LEVEL 2 2.25%/FEET Sensitivity level
Height 1.75" LEVEL 3 2.75%/FEET Sensitivity level
LEVEL 4 3.25%/FEET Least Sensitive Level

Ordering Information
Model Description
MIX-4010 Photoelectric Smoke Detector (Non-Isolated)
MIX-4010-ISO Photoelectric Smoke Detector (with short-circuit isolator)
MIX-4020 Multi-Criteria/Multi-Sensor (Non-Isolated)
MIX-4020-ISO Multi-Criteria/Multi-Sensor (with built-in short circuit isolator)
MIX-4030 Heat Detector (Non-Isolated)
MIX-4030-ISO Heat Detector (with built-in short circuit isolator)
MIX-4090 MIX-4000 Series Addressable Device Programmer
MIX-4001 6" Detector Base
MIX-4002 4" Detector Base

THIS INFORMATION IS FOR MARKETING PURPOSES


ONLY AND NOT INTENDED TO DESCRIBE THE
PRODUCTS TECHNICALLY.
Canada U.S.A.
25 Interchange Way 4575 Witmer Industrial Estates For complete and accurate technical information relating to
performance, installation, testing and certification, refer to technical
Vaughan, Ontario L4K 5W3 Niagara Falls, NY 14305
literature. This document contains intellectual property of Mircom.
Telephone: (905) 660-4655 Toll Free: (888) 660-4655 The information is subject to change by Mircom without notice.
Fax: (905) 660-4113 Fax Toll Free: (888) 660-4113 Mircom does not represent or warrant correctness or completeness.

www.mircom.com CAT. 9501