Plumbing Layout: General Notes
Plumbing Layout: General Notes
Plumbing Layout: General Notes
GENERAL NOTES:
1. ALL PLUMBING WORKS INCLUDED HEREIN SHALL BE DONE IN
ACCORDANCE WITH THE LATEST PROVISION AND APPROVED EDITION OF
3.00 THE REVISED NATIONAL PLUMBING CODE OF THE PHILIPPINES AND WITH
THE RULES AND REGULATION OF THE LOCAL AGENCY.
1
2. ALL MATERIALS TO BE USED SHALL BE NEW AND APPROVED TYPE FOR
ITS LOCATION AND PURPOSES.
2.00 ROOM 3. ALL SLOPE FOR HORIZONTAL SEWER LINES SHALL MAINTAIN 2 %
ST MINIMUM UNLESS OTHERWISE SPECIFIED.
2500
INLET
0.50 0.50
7.15 3.39
0.50 0.50
0.50
0.50
0.50
0.07
1.50
1500
1500
0.38
1300
100
7.00
DIGESTIVE 7.00
5.69
CHAMBER 8.50
8.50
1.00
LEACHING
OUTLET
CHAMBER
100
2500
0.50 0.50
3.89
1.00 1.00
2500
1
5.40 1.50 1.89 1.50
NTS
ENGINEER : REG. NO. 0156616 PROJECT TITLE / LOCATION : OWNER : SHEET CONTENTS : DRAWN / PLOTTED BY : SHEET NO.
FLOOR PLAN
PTR NO.
AS BUILT PLAN FOR RESIDENTIAL HOUSE APRIL RACHEL G. BALDESTAMON ELEVATIONS
DATE : PL
BRGY. SICSICAN, PUERTO PRINCESA CITY
DATE ISSUED
APPROVED
REVISED BY : 1 1
MASTER PLUMBER PLACE ISSUED PTO. PRINCESA CITY DATE :