Expertise Contracting Company: VLF Cable Testing & Reliability Evaluation of MV Cables

This document is a report on diagnostic tests conducted on medium voltage cables, including DC insulation resistance tests, tan delta tests, VLF withstand tests, and partial discharge tests. It provides test setup details and results for each test, including measured values for insulation resistance, tan delta, test voltages, times, currents, and partial discharge measurements. The report concludes with comments on the analysis and signatures acknowledging the test and analysis.

Uploaded by

Humayun Ahsan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
61 views3 pages

Expertise Contracting Company: VLF Cable Testing & Reliability Evaluation of MV Cables

This document is a report on diagnostic tests conducted on medium voltage cables, including DC insulation resistance tests, tan delta tests, VLF withstand tests, and partial discharge tests. It provides test setup details and results for each test, including measured values for insulation resistance, tan delta, test voltages, times, currents, and partial discharge measurements. The report concludes with comments on the analysis and signatures acknowledging the test and analysis.

Uploaded by

Humayun Ahsan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 3

Expertise Contracting Company

Rev.
Business Unit Document Ref No.: Affectivity Date Page No.
No.
Projects & Engineering FM-DIV01-0034 00 20th Dec. 2015 1 of 11

VLF DIAGNOSTIC TESTS REPORT FOR MV CABLE

VLF CABLE TESTING & RELIABILITY EVALUATION


OF MV CABLES

Date:
Client Project Title
PO ID Equipment Type:
Voltage level Equipment Tag
Size/ Length
Primary station Secondary station
System Voltage Erec. Date
No of Cables End- user

DC Insulation Resistance Test Result at 5 kV


R-G PHASE (GΩ) Y-G PHASE (GΩ) B-G PHASE (GΩ)
Before After Before After Before After
IR 30 secs
IR 1 min
Dielectric Absorption Ratio
Capacitance(nF)

DC Insulation Resistance Test Result at 5 kV


R-Y PHASE (GΩ) Y-B PHASE (GΩ) B-R PHASE (GΩ)
Before After Before After Before After
IR 30 secs
IR 1 min
Dielectric Absorption Ratio
Capacitance(nF)

Tan Delta set-up


Voltage Step 1 = 0.5 U0
Voltage Step 2 = 1.0 U0
Voltage Step 3 = 1.5 U0
No. of measurements per step
Time per measurement

1|Page
Expertise Contracting Company
Rev.
Business Unit Document Ref No.: Affectivity Date Page No.
No.
Projects & Engineering FM-DIV01-0034 00 20th Dec. 2015 2 of 11

VLF DIAGNOSTIC TESTS REPORT FOR MV CABLE

Tan Delta Test (1.2 to 3.6 kV)


R-Phase Y-Phase B-Phase Remarks
Tan delta at 0.5 Uo x 10-3
Tan delta at 1.0 Uo x 10-3
Tan delta at 1.5 Uo x 10-3
Tan delta Stability at 1U0 x 10-3
Delta Tan delta ( 1.5U0 -0.5 U0 ) x 10-3

VLF Withstand Test Result – Overview


R-PHASE
Phase Voltage RMS Waveform Frequency Test Time Current Capacitance Result
Step 1
Step 2
Step 3
Y-PHASE
Phase Voltage RMS Waveform Frequency Test Time Current Capacitance Result
Step 1
Step 2
Step 3
B-PHASE
Phase Voltage RMS Waveform Frequency Test Time Current Capacitance Result
Step 1
Step 2
Step 3

PARTIAL DISCHARGE SET-UP


Inception/Extinction Voltage Steps (kV)
Maximal Measurement Time
Distance Cluster Radius
Minimum no. of events in Distance Cluster
Calibration Level

2|Page
Expertise Contracting Company
Rev.
Business Unit Document Ref No.: Affectivity Date Page No.
No.
Projects & Engineering FM-DIV01-0034 00 20th Dec. 2015 3 of 11

VLF DIAGNOSTIC TESTS REPORT FOR MV CABLE

PARTIAL DISCHARGE TEST RESULTS – OVERVIEW (52-KM-001-R1, Y1, B1)


R PHASE Y PHASE B PHASE
Noise Level (mV)
Cable Length (meters)
Inception Voltage (kV)
Extinction Voltage (kV)
No. of PD events

Average Charge (pC)

Type of Discharges
Location (meters)
Comments

Analysis Comments

Acknowledge by:
Tested & Witnessed By
Analyzed By: Veolia:

Designation: Designation:

Signature: Signature:

3|Page