Yarway Cryogenic Desuperheater For LNG Terminal

Download as pdf or txt
Download as pdf or txt
You are on page 1of 13

AT-37/47 Cryogenic DSH

in LNG Applications
PT. Control Systems Arena Para Nusa
Flow Control Group

Emerson Confidential
LNG Overview
• LNG is liquified natural gas, which mainly contains Methane (CH4) with some of Ethane (C2H6).
• Liquified nature gas is only takes 1/600 of the volume in its gaseous state. The liquified conditions
is used facilitate the carriage of nature gas over long distance.

Yarway Cryogenic Injector Targeting Application in Import Terminal Section


Emerson Confidential
LNG Terminal

Emerson Confidential 4
Targeted Applications at LNG Receiving Terminals
2

1 Vapor return to ship cooling 2 Compressor inlet temperature control


• A compressor is used to compress BOG for re-condensation
• When discharging tankers, the diminishing volume
of the tanks need to be compensated to prevent and return to storage tank farm or supply to NG distribute
implosion. pipeline.
• Compressor inlet gas volume is direct function of the gas
• Tank volume compensation by a separate BOG return
line. temperature.
• A lower inlet temperature into the compressor will allow
• BOG return to ship gas temperature, need to be you to use a smaller compressor, with lower power
controlled to prevent explosive type of boil in ship tanks.
consumption.
• The Yarway Cryogenic Injector is required for safe and • The Yarway Cryogenic injector cool down the gas
controlled unloading of the ship LNG tanks. temperature to the extend that the outlet temperature of the
compressor remains without desirable limit.
• The injector should have wide rangeability capacity in
handling wide load range
Emerson Confidential
Results of Poor Performance of Cryogenic Injector
• Vapor return to ship cooling
– Kock-out Drum Level Control Failure
– With liquid accumulation downstream of the Injector, the liquid could fill up the suction drum on the downstream of
the injector. Usually, the suction drum has a level indicator and when liquid arises above a certain level it will
initiate a system trip.

• Compressor inlet temperature control


– Increase compressor energy consumption
– Poor performance injector could cause the gas temp oscillation or higher than design, which lead to excessive
energy consumption for the compressor on the downstream.

Emerson Confidential 6
AT-37/47 Cryogenic Injector Overview (Design Temp -196 deg C)

Liquid
Flange
Vapor
Flange

Optional AT-38/48 in SST construction for temp down to -46 deg C


Emerson Confidential 7
Yarway Sprayhead Nozzle

• A – Orifice, B – Nozzle Body


• ΔP across Orifice results in an
increase in fluid velocity
• The fluid is rotated in the nozzle
chamber before being emitted

The combination of splitting the feed flow, increasing velocity and rotating effect, ensures
that the fluid is injected into the system in a fine symmetrical hollow cone spray
Emerson Confidential 8
Nozzle Type

AT-37/47 has same type of Nozzle as AT-38/48 but materials are SS 304/316
Emerson Confidential 9
Piston (Ring) Materials

PTFE Piston (CL150-CL300)

AluBrz Piston (CL600-CL900)

The Piston Material depends on DSH’s Pressure Rating


Emerson Confidential 10
Packing Option
• Graphite
– Standard Offer
– Spring/Live Load design

• PTFE
– Spring/Live Load design
– No Fire safe design

• Graphite (James Walker / Supagraf Control)


– With long studs and bushings
– Special surface finish on stem required
– FET in accordance with ISO 15848-1

Emerson Confidential 11
Fugitive Emission Test
AT-48 w/ James Walker Graphite Packing AT-37 w/ James Walker Graphite Packing
Test Temp: -50ºC, Cycle: CC1, Leakage Rate: BH Test Temp: -196ºC, Cycle: CC1, Leakage Rate: BH

Emerson Confidential 12
Desuperheater Dimensional Overview
Liq Flange Orientation

Standard
L Dimension
150mm or 200mm

Standard Insertion
A Dimension
14.96’’
T 15.71’’
22.83’’
23.58’’
Or “To be agreed upon”

L A

Standard B Dimension
T Dimension B Max = 1500mm
Options in FF2/OED (To be agreed upon)

Emerson Confidential 13
Cryogenic Test

Cryogenic Test Facilities – Nilai (AP Prime)


Emerson Confidential
Delivery Doc to be shared with Nilai to confirm cryogenic test capacity based on DSH size 15