Triple Combo

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Triple Combo

Triple Combo Tool


String

Scientific Application LEH-MT


(mud temperature)
39.93 m
38.54
The Triple Combo tool string is always run first and EDTC
(telemetry,
acquires most of the basic petrophysical and lithologi- gamma ray) 36.56

cal logs (density, porosity, resistivity, gamma ray). This HNGS


(spectral
35.70

string also measures the borehole width, an impor- gamma ray)


33.52
tant indicator of borehole and log quality.
The porosity, density, and resistivity logs collect petro-
LEH-MT 29.01 m
physical and geotechnical information about the pen- (mud temperature)
28.05
APS 27.60
etrated formations. In sediments, the general trend in (porosity)
EDTC
(telemetry,
26.30
these logs is dominated by increasing consolidation gamma ray) 25.63

with depth. Deviations from this trend are caused

Cumulative length (m)


by lithological change, lithification (cementation), Caliper Caliper

underconsolidation (e.g., high pore-fluid pressure), HLDS 20.87 HLDS 20.51


(density) (density)
or the presence of gas hydrates (hydrate in the pore Knuckle joints
20.11 19.75

Cumulative length (m)


Knuckle joints
space increases resistivity and sonic velocity). The
16.00 15.64
principal advantage of these logs over the equivalent Centralizer Centralizer
core measurements is that the logs record the in- 13.72 13.36
situ property, whereas the cores are expanded and
depressurized and can suffer from end-effects and
biscuiting. HRLA 10.41 HRLA 9.78
(resistivity) (resistivity)

Components 6.35 5.99


Centralizer
The standard Triple Combo logging tool may consist Centralizer
3.67 3.71
of three of the following tools: MSS 2.90
HNGS
(magnetic (spectral
susceptibility,
• Accelerator Porosity Sonde (APS*) deep reading) 0.39
gamma ray)
Tool zero
• Hostile Environment Litho-Density Sonde (HLDS*)
Examples of two different Triple Combo tool
• Hostile Environment Natural Gamma Ray Sonde string configurations (Exp 349).
(HNGS*)/Enhanced Digital Telemetry Cartridge (EDTC-B*)
• High-Resolution Laterolog Array (HRLA*)/Phasor Dual Induction-Spherically Focused Resistivity Tool (DIT*)
• Magnetic Susceptiblility Sonde (MSS-B) (developed by Lamont)

Deployment Notes
APS
An electronic neutron source (mintron) and five detectors provide information for porosity, gas detection, clay
evaluation, improved vertical resolution, and borehole corrections. The APS is typically run with the DIT, HLDS,
and HNGS tools. Tool length is 3.96 m (13 ft).

*®trademark of Schlumberger 10/14


HLDS
The HLDS consists of a 137Cs source and two detectors mounted on a shielded skid that is pressed against the for-
mation. Bulk density and photoelectric formation factor are derived from the spectra measured by the detectors.
The available spectral information from the HLDS is also used for improved log and calibration quality control.
The HLDS is typically run with the HNGS and APS tools. It can be combined with DIT, DLL, and ASI. Tool length
is 3.83 m (12.58 ft).

HNGS
The HNGS utilizes two bismuth germanate (BGO) scintillation detectors to measure the natural gamma ray
radiation of the formation. At least one pass is made with the HNGS past the mudline for correct location of the
mudline itself. Depending on the environment, the HNGS may be run on other tool strings as well. Tool length is
25.88 cm (8.5 ft). The gamma ray log is generally used to depth match between logging runs.

EDTC-B
EDTC-B is a downhole tool that combines two commonly run sensors with a high-speed telemetry downhole
modem that can be used in high-pressure and high-temperature environments. The primary function is to pro-
vide high-speed (>1 Mbps) communications between the wireline tools downhole and the acquisition system at
surface. Additionally, it includes a scintillation gamma ray detector that provides a measurement equivalent to
that of the Scintillation Gamma Ray tool formerly used for for seismic operations. The gamma ray log is generally
used to depth match between logging runs.

HRLA
The HRLA tool provides six resistivity measurements with different depths of investigation (including the bore-
hole, or mud resistivity, and five measurements of formation resistivity with increasing penetration into the
formation). The HRLA is typically deployed on the Triple Combo tool string in high-resistivity environments.
It is compatible with virtually all other tools commonly used on the JOIDES Resolution except the Formation
MicroScanner (FMS), and unlike the bottom-only DIT, it can be run higher in the string should it be necessary to
combine it with a bottom-only tool such as the MSS. Tool length is 7.35 m (24.1 ft).

DIT
The DIT provides measurements of spontaneous potential (SP) and three different resistivity values: IDPH (deep
induction), IMPH (medium induction), and SFLU (shallow spherically focused resistivity). Since the solid constitu-
ents are orders of magnitude more resistive than pore fluids in most rocks, resistivity is controlled mainly by the
conductivity of the pore fluids and by the amount and connectivity of the pore space. Typically the DIT is run
with APS, HLDS, and HNGS. The DIT has an internal temperature measurement that may be useful in high-tem-
perature environments.
MSS-B
MSS-B is a wireline logging tool that measures borehole magnetic susceptibility at two vertical resolutions and
depths of investigation. When run in a Schlumberger tool string, the MSS-B must be run as the bottom tool
below a pressure bulkhead. Most combinations of inline Schlumberger tools can be run above. Tool length
(effective makeup) is 540 cm (212.6 in.).

Triple Combo 2 10/14