Sample Validation Report For Accucharger Usb Chargers

This report summarizes test results for two AccuCharger USB charger samples. Sample 1 exhibited steady output up to 18V during overvoltage testing, while Sample 2 shut off after 19V and was damaged. Both samples had good construction quality. Heating was observed at loads over 2A. Sample 1 had a ripple voltage of 28mV and Sample 2 had 20.8mV. Overload and continuous on testing showed the chargers functioned as expected with overheating protection.

Uploaded by

sushma reddy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
31 views6 pages

Sample Validation Report For Accucharger Usb Chargers

This report summarizes test results for two AccuCharger USB charger samples. Sample 1 exhibited steady output up to 18V during overvoltage testing, while Sample 2 shut off after 19V and was damaged. Both samples had good construction quality. Heating was observed at loads over 2A. Sample 1 had a ripple voltage of 28mV and Sample 2 had 20.8mV. Overload and continuous on testing showed the chargers functioned as expected with overheating protection.

Uploaded by

sushma reddy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Sample Validation report for AccuCharg

USB Chargers
Sample 1
SL. No Load Applied Time Input Voltage Input Output Output
(Minutes) (V) current (A) Voltage (V) current (A)

1 0 1.08 4.401 1.95


2 5 12 1.08 4.397 1.93
3 10 1.07 4.414 1.98
2A
4 0 0.89 4.429 1.92
5 5 14 0.92 4.427 1.94
6 10 0.92 4.423 1.93
7 2.35 A NA 12 1.3 4.273 2.35

Sample 1 Sample 2
SL. No Input Voltage Output Input Voltage Output
(V) Voltage (V) (V) Voltage (V)
No load
condition Starting
1 6.8 5 6.8 5
voltage
2 12 5.073 12 5.095
3 14 5.078 14 5.101
4 Overvoltage 31.4 5.099 31.4 5.123

When overvoltage test was conducted at 2A load condition, then sample 1 exhibited steady outp
till 18V. After that the turning OFF became more frequent. But the sample was found to functio
Observations during
afterwards too.Whereas when the same test was conducted in sample 2, the USB charger got turn
overvoltage test
OFF after about 19V and the product was found to be damaged(switching IC failed), as it stoppe
functioning after wards.

Observations regarding Both the samples were found to have good constructional quality. The
constructional quality wires appear sturdy and the PCB quality was found to be good too
IMAGES

Heating was observed when the USB charger is kept on with a load of 2A for more than 10 minute
Observations when the temperature is high . When the load or input voltage increases , the automatic cut-off b
off also increases with increase in load or input. Above 2A load, the cuf-off happens for

Sample 1 = 28mV

Ripple voltage

When a high load of 3.4A is provided at 12V ,the output current was measured to be 0.91A fo
Overload conditon
reduced. It was found to be unable to sustain the

Continuous ON test The USB charger was subjected to continous ON test for 15 hours with a load of 1.1A. The charge
observation test and minimal heating was observed.

Observations regarding At a load of 2.4A ,the saturated temper


temperature rise Celsius and it was frequently tu
Observations regarding At a load of 2.4A ,the saturated temper
temperature rise Celsius and it was frequently tu

Features by 1. Over heating protection, 2.Over charge Protection, 3.Short circuit protection, 4.Over voltage pro
manufacturer indicating LED.
n report for AccuCharger
B Chargers
Sample 2
Time Input Voltage Input Output Output
(Minutes) (V) current (A) Voltage (V) current (A)

0 1.05 4.437 1.98


12
10 1.08 4.426 1.98

0 0.92 4.429 1.97


14
10 0.92 4.435 1.98

NA 12 1.31 4.266 2.39

then sample 1 exhibited steady output


But the sample was found to function
in sample 2, the USB charger got turned
aged(switching IC failed), as it stopped
ds.
a load of 2A for more than 10 minutes. Automatic cut-off for short intervals are happening
age increases , the automatic cut-off becomes more frequent and the time duration of cut-
bove 2A load, the cuf-off happens for like 4,5 seconds for almost every 1,2 minutes

Sample 2 =20.8mV

current was measured to be 0.91A for sometime and then cut-off happens untill load is
was found to be unable to sustain the load.

hours with a load of 1.1A. The charger was found to be in working condition at the end of
and minimal heating was observed.

a load of 2.4A ,the saturated temperature found on the outer plastic surface was 55 degree
Celsius and it was frequently turning ON and OFF due to temperature cut-off.
a load of 2.4A ,the saturated temperature found on the outer plastic surface was 55 degree
Celsius and it was frequently turning ON and OFF due to temperature cut-off.

t circuit protection, 4.Over voltage protection, 5.Flip cover for dust free, 6.Charger ON