Sample Validation Report For Accucharger Usb Chargers
Sample Validation Report For Accucharger Usb Chargers
USB Chargers
Sample 1
SL. No Load Applied Time Input Voltage Input Output Output
(Minutes) (V) current (A) Voltage (V) current (A)
Sample 1 Sample 2
SL. No Input Voltage Output Input Voltage Output
(V) Voltage (V) (V) Voltage (V)
No load
condition Starting
1 6.8 5 6.8 5
voltage
2 12 5.073 12 5.095
3 14 5.078 14 5.101
4 Overvoltage 31.4 5.099 31.4 5.123
When overvoltage test was conducted at 2A load condition, then sample 1 exhibited steady outp
till 18V. After that the turning OFF became more frequent. But the sample was found to functio
Observations during
afterwards too.Whereas when the same test was conducted in sample 2, the USB charger got turn
overvoltage test
OFF after about 19V and the product was found to be damaged(switching IC failed), as it stoppe
functioning after wards.
Observations regarding Both the samples were found to have good constructional quality. The
constructional quality wires appear sturdy and the PCB quality was found to be good too
IMAGES
Heating was observed when the USB charger is kept on with a load of 2A for more than 10 minute
Observations when the temperature is high . When the load or input voltage increases , the automatic cut-off b
off also increases with increase in load or input. Above 2A load, the cuf-off happens for
Sample 1 = 28mV
Ripple voltage
When a high load of 3.4A is provided at 12V ,the output current was measured to be 0.91A fo
Overload conditon
reduced. It was found to be unable to sustain the
Continuous ON test The USB charger was subjected to continous ON test for 15 hours with a load of 1.1A. The charge
observation test and minimal heating was observed.
Features by 1. Over heating protection, 2.Over charge Protection, 3.Short circuit protection, 4.Over voltage pro
manufacturer indicating LED.
n report for AccuCharger
B Chargers
Sample 2
Time Input Voltage Input Output Output
(Minutes) (V) current (A) Voltage (V) current (A)
Sample 2 =20.8mV
current was measured to be 0.91A for sometime and then cut-off happens untill load is
was found to be unable to sustain the load.
hours with a load of 1.1A. The charger was found to be in working condition at the end of
and minimal heating was observed.
a load of 2.4A ,the saturated temperature found on the outer plastic surface was 55 degree
Celsius and it was frequently turning ON and OFF due to temperature cut-off.
a load of 2.4A ,the saturated temperature found on the outer plastic surface was 55 degree
Celsius and it was frequently turning ON and OFF due to temperature cut-off.
t circuit protection, 4.Over voltage protection, 5.Flip cover for dust free, 6.Charger ON