0% found this document useful (0 votes)
464 views3 pages

Pile Analysis (As2159) in Accordance With Australian Standard: Piling-Design and Installation Per AS 2159-2009

This document summarizes the analysis of a drilled concrete pile with a 600mm diameter and 3500mm length. It includes details of the pile, soil stratum, design actions, and calculations to check the axial and lateral capacity of the pile. The axial capacity is determined to exceed the factored load. The lateral capacity and deflection are also determined to meet requirements.

Uploaded by

Phranck
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
464 views3 pages

Pile Analysis (As2159) in Accordance With Australian Standard: Piling-Design and Installation Per AS 2159-2009

This document summarizes the analysis of a drilled concrete pile with a 600mm diameter and 3500mm length. It includes details of the pile, soil stratum, design actions, and calculations to check the axial and lateral capacity of the pile. The axial capacity is determined to exceed the factored load. The lateral capacity and deflection are also determined to meet requirements.

Uploaded by

Phranck
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Project Job Ref.

FKA Ventures Section Sheet no./rev.


box ks1234 1
Calc. by Date Chk'd by Date App'd by Date
F 8/17/2022

PILE ANALYSIS (AS2159)


In accordance with Australian Standard: Piling-Design and installation per AS 2159-2009
Tedds calculation version 1.0.01

600 mm

Pile details
Installation method; Drilled; Shape; 600 mm diameter
Length; L = 3500 mm
Material details
Material; Concrete; Concrete strength; f’c = 40 MPa
Concrete in situ strength; fcmi = 43 MPa; Modulus of elasticity; E = 33153 MPa
Geometric properties
Assumed top1.5 x h ineffective; Yes
Bearing area; Ab = 2827.433 cm2; Pile perimeter; Perimpile = 1.88 m
Moment of inertia; I = 636173 cm4; Section modulus; S = 21206 cm3
Project Job Ref.

FKA Ventures Section Sheet no./rev.


box ks1234 2
Calc. by Date Chk'd by Date App'd by Date
F 8/17/2022

Flat,d

7828 mm
Fd

3500 mm
4000 mm

fm,s1 = 0 kN/m2
fb1 = 150 kN/m2

fm,si = Average unit skin friction, compression, f bi = Ultimate unit end bearing

Stratum details
Stratum Geomaterial Thickness, Ultimate unit Average skin Average skin Strength Strength
tstratai bearing, fbi friction, friction, tension, reduction reduction
(mm) (kN/m2) compression, fm,sti factor, factor,
fm,si (kN/m2) comp. tension
(kN/m2) c,g t,g
1 Cohesive 4000 150 0 - 0.5 -

Design action details


Design action, compression; Fc,d = 13.9 kN; Design action, tension; Ft,d = 0 kN
Design action, lateral; Flat,d = 10.3 kN; Service level action, lateral; Flat,ds' = 6.7 kN
Axial resistance
Des. ult. axial bearing resist.; Rb = 42.4 kN; Des. ult. axial friction resist; Rs = 0 kN
Des. ult. geotech. strn. comp.; Rd,ug = 42.4 kN; Geotech strn. reduction factor; c,g = 0.5
Des. geotechnical strn. comp.; Rd,g = 21.2 kN; Fc,d / Rd,g = 0.655
PASS - Design ultimate axial resistance exceeds factored axial load
Lateral analysis properties (Brinch Hansen method)
Pile head fixity; Free; Eccentricity of applied action; eactual = 7828 mm
Lateral action duration; Long-term
Lateral stratum details
n
Overburden pressure, pozSi =   ' t
i 1
i stratai

Stratum Cohesion, Friction angle, Unit weight of soil, Overburden pressure,


ci (kN/m2) i (degrees) i (kN/m ) 3 pozSi (kN/m2)
1 5 30 18 72
Project Job Ref.

FKA Ventures Section Sheet no./rev.


box ks1234 3
Calc. by Date Chk'd by Date App'd by Date
F 8/17/2022

Resisting soil is divided into 10 segments to determine lateral resistance


From iteration, assume depth of point of rotation; X = 2550 mm
Dist from lateral actn to ground; e = eactual = 7828 mm
Sum of moments about point of load application near zero;
Mtr = 0 kNm
Sum of moments about point of rotation;
MX = 583.5 kNm
Ultimate Soil lat resist.; Rd,ug,lat = 56.2 kN
Lateral resistance factor; lat,g = 0.5; Ultimate lateral action capacity; Rd,g,lat = 28.1 kN
Flat,d / Rd,g,lat = 0.366
PASS - Ultimate lateral load capacity exceeds factored lateral load
Lateral deflection
Virtual point of fixity, iteration; Vzf = 0 kN;
zf = 842 mm
Actual deflection at top of pile; Lat = 6.9 mm; Allowable lateral deflection; LatAllow = 20 mm
Lat / LatAllow = 0.345
PASS - Allowable lateral deflection exceeds actual lateral deflection
;