Contact: Product Specification - Tripol™ 9010

TriPol 9010 is a liquid antiscalant designed to inhibit scaling from iron, carbonate, sulfate, and fluoride compounds. It has been shown to increase system recovery rates up to 75% or more and extend membrane life by reducing cleaning needs. The product is shipped as a liquid and dosed before RO/NF systems between 2 to 5 ppm based on water quality and desired recovery.

Uploaded by

Carlos Benitez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
120 views1 page

Contact: Product Specification - Tripol™ 9010

TriPol 9010 is a liquid antiscalant designed to inhibit scaling from iron, carbonate, sulfate, and fluoride compounds. It has been shown to increase system recovery rates up to 75% or more and extend membrane life by reducing cleaning needs. The product is shipped as a liquid and dosed before RO/NF systems between 2 to 5 ppm based on water quality and desired recovery.

Uploaded by

Carlos Benitez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

PRODUCT SPECIFICATION – TRIPOL™ 9010

NSF/ANSI Standard 60
10 mg/L

TriPol 9010 is a multi-component liquid antiscalant that was scientifically formulated to provide advanced inhibition of scaling and
fouling due to iron, carbonate, sulfate, and fluoride compounds. These compounds have historically limited system recoveries,

dosages, provides lower operational costs through reduced cleaning requirements, extended membrane life, and increased system
recovery capabilities.

Enhanced carbonate scale control


Superior control of sulfate scales
Enhanced iron dispersant capability

PROVEN PERFORMANCE
With MICRODYN-
system recovery rates increase to 75% and beyond with feed waters that formerly restricted recovery rates due to high carbonate
scaling potential (>2.6 LSI), and above average levels of iron, silica, and phosphate in their system concentrate (at 75% recovery).

APPLICATION
TriPol 9010 is metered into the feed water at a point where turbulent flow will ensure adequate chemical mixing prior to entering
the RO or NF system. This is usually done prior to the cartridge filters and high pressure pump. Dosing rates vary depending on
feed water quality and recovery but normally run between 2 and 5 ppm. For exact dosing for larger systems, contact
MANN+HUMMEL Water & Fluid Solutions Technical Service. TriPol 9010 contains a dispersant and can be used if there is iron or
other metal hydroxides in the feed water.

SATURATION LIMITS
Max. Langlier Saturation Index +2.6* *Indicates levels in the concentrate. Levels may be exceeded on occasion.
Max. CaSO4 Saturation 300%* Contact MICRODYN-NADIR for more information.
Max. SrSO4 Saturation 800%*
Max. BaSO4 Saturation 10,000%*
Silica +120%*

PACKAGING
TriPol 9010 is shipped as a liquid in 5 gallon plastic pails or 55 gallon plastic drums.

SDS INFORMATION
For the most up to date SDS information, please contact MANN+HUMMEL Water & Fluid Solutions Technical Service or visit our
website at www.microdyn-nadir.com.

Contact
Europe Americas Asia
Germany: +49 611 962 6001 USA: +1 805 964 8003 Singapore: +65 6457 7533
Italy: +39 0721 1796201 [email protected] China: +86 10 8413 9860
[email protected] [email protected]

DATE: 07/01/2021