Connection Master
Connection Master
siemens.com
Connection Master:
Your safe way to future-proof
utility communications
The pace of innovation in telecommunications is increasing at breathtaking speed.
What is necessary to keep your utility at the leading edge in this area? How can you
benefit from new, IP-based services – while protecting your existing SDH and PDH
interfaces in running systems?
2
System Overview covering today’s
and tomorrow’s needs
Trunk interfaces: expected. End-to-end circuit provisioning of 64 kbps is a
SDH STM-1/4/16 good example of how efficient NMS is designed to be.
Access interfaces: It can seamlessly interface with any Network Management
• Legacy interfaces e.g. FXS, FXO, E&M, X21, V35,..... System (NMS) via its powerful NorthBound Interface
• Ethernet interface (NBI) over SNMP.
Siemens Multiservice
Manager is PC software
for local management of
Connection Master nodes
and for managing a large
number of nodes in the
network.
3
Application
examples
Multiservice solution
CM offers a multiplexer, a cross-connect,
and a transport device – all in one node
STM-1/4/16
CM
CM
FMX2
CM
E1 loop protection
4
Flexible integration of teleprotection systems (e.g. SWT 3000)
Teleprotection signals can be transmitted via two different transmission routes,
either via digital interfaces (G.703, X.21) or the optical interface C37.94
Power line
SDH network
RS232(SCADA) RS232(SCADA)
Central Central
station station
RS232 RS232 E1 over PDH
n x VC-12 over RS232 RS232
(SCADA) (SCADA) or VC-12 over
STM-1/4/16 (SCADA (SCADA
STM-1/4/16
server) server)
RS232(SCADA) RS232(SCADA)
5
Important technical data
and ordering codes
interfaces ordering code
CU SDH ST32001.01
SFP interfaces 4 x STM-4/16, 4 x STM-1/4 or
4 x STM-4/16, 2 x STM-1/4, 2 x GbE
Ethernet Unit 1000BT, 8 ports ST32002.01
RJ-45 interface 6 x 10/100/1000BASE-T
Full duplex or half duplex
Auto negotiation
4 x PoE
SFP interface 1 x 10/100/1000BASE
1 x 1000BASE
E1/T1 Unit, 8 ports, 75 ohm / 120 ohm ST32003.01 / ST32003.11
E1 G.703/G.704 interface 8 x SMB (ST32003.01)
8 x RJ-45 (ST32003.11)
Data Unit V and X, 4 ports ST32004.01
4-port SSC interface V.28, V.11, V.35, X.21, RS-530, RS-530A
Data Unit G.703/64k, 8 ports ST32004.02
RJ-45 interface 8 x G.703 / 64 kbit/s
Optical Teleprotection Unit, 4 ports ST32004.11
Optical interfaces 8 x ST connector, 4 ports
nx64 kbit/s payload (n = 1…12); multimode fiber;
transmission capacity per port: 64…768 kbit/s
Protocol IEEE C37.94
VF/E&M Unit, 8 ports ST32005.01
8-port SSC interface 8 x 2-wire / 4-wire
Signaling 3 x E and 3 x M per port
FXS Unit, 16 ports ST32005.11
RJ-45 interface 8 connectors, 2 ports/connector
Integrated ring generator 25 Hz / 50 Hz
Signaling R2 / Hot Line
FXO Unit, 16 ports ST32005.21
RJ-45 interface 8 connectors, 2 ports/connector
Advanced DXC Unit ST32010.01
Cross-connect capacity Based on license
Maximum cross-connect capacity: 189 x E1 / VC-12 links
(equivalent to 63 E1 Y loops)
Granularity: 8 kbit/s...nx64 kbit/s, non-blocking
Connection types B ( point-to-point connection supporting condition bit),
Y ( loop protection), C (digital summing), S (VF summing),
M (bit masking)
6
alarm unit, mechanics, and power supply
Alarm Unit ST32011.01
Digital inputs 15 pcs; E&M or TTL; alarm filtering time 10 ms…10 min
Analog inputs 4 pcs; -150 VDC…+150 VDC or 0.0 VDC…4.0 VDC;
alarm filtering time 10 ms…10 min
Alarm outputs 3 pcs; dry loop or ground connection
Subrack 6-Slot ST32009.01
Installation capacity 2…4 tributary units
Subrack 16-Slot ST32009.04
environmental
Environmental specifications
Climatic: 6-slot subrack with fan Operation: EN 300 019-1-3, Class 3.1 (-5 to +50 °C)
Storage: EN 300 019-1-1 Class 1.2 (-25 to +55 °C)
Transport: EN 300 019-1-2 Class 2.3 (-40 to +70 °C)
Climatic: 16-slot subrack with fan Operation: EN 300 019-1-3, Class 3.2 (-5 to +55 °C)
Storage: EN 300 019-1-1 Class 1.2 (-25 to +55 °C)
Transport: EN 300 019-1-2 Class 2.3 (-40 to +70 °C)
EMC EN 300 386 V1.4.1…1.6.1, class B
EN 55022, class B
Safety EN 60950-1
7
Siemens AG
Energy Management
Freyeslebenstr. 1
91058 Erlangen,
Germany
www.siemens.com
The information provided in this brochure contains All product designations may be trademarks or product
descriptions or characteristics of performance which in names of Siemens AG or supplier companies whose use
case of actual use do not always apply as described or by third parties for their own purposes could violate the
which may change as a result of further development of rights of the owners.
the products. An obligation to provide the respective
characteristics shall only exist if expressly agreed in the
terms of contract.