y ELEMKO reserves the right to modify, add or remove any information included in this catalogue, if necessary. Every updated version of the catalogue automatically
cancels all the previous ones.
y Photographs of the products are indicative.
y This catalogue has been compiled only to provide information of our products and their applications and in any case does not form a contract.
y The company assumes no liability for loss or damage which may be caused by incorrect implementation regarding the use of the products included in this catalogue.
y ELEMKO company assumes no responsibility for any misprints in this catalogue.
īȞȦȡȚȓĮ İ IJȘȞ ǼȁǼȂȀȅ Meet ELEMKO
ǿȈȉȅȇǿȀȅ HISTORY
ȉȠ 1973 ȒIJĮȞ IJȠ ȟİțȓȞȘĮ ȚĮȢ İʌȚIJȣȤȘȑȞȘȢ ʌȠȡİȓĮȢ ʌȠȣ ĮțȠȜȠȪșȘıİ Ș Year of 1973 was the start of a
İIJĮȚȡİȓĮ ǼȁǼȂȀȅ, İ țȪȡȚȠ ĮȞIJȚțİȓİȞȩ IJȘȢ IJĮ: successful route for our company
with main object the:
«ȅȜȠțȜȘȡȦȑȞĮ ȈȣıIJȒĮIJĮ ǹȞIJȚțİȡĮȣȞȚțȒȢ ȆȡȠıIJĮıȓĮȢ»
ʌȠȣ ĮijȠȡȠȪȞ: Global Solutions of Lightning
• ȆȡȠıIJĮıȓĮ țĮIJĮıțİȣȫȞ Įʌȩ ȐİıȠ țİȡĮȣȞȚțȩ ʌȜȒȖĮ Protection Covering:
• ȆȡȠıIJĮıȓĮ Įʌȩ ȀȡȠȣıIJȚțȑȢ ȊʌİȡIJȐıİȚȢ ȘȜİțIJȡȚțȫȞ țĮȚ
ȘȜİțIJȡȠȞȚțȫȞ ıȣıIJȘȐIJȦȞ • Protection of structures and buildings against direct
• ȈȣıIJȒĮIJĮ īİȚȫıİȦȞ lightning strike
• Surge Overvoltage Protection of electrical & electronic systems
Ǿ ĮțȡȩȤȡȠȞȘ țĮȚ ȣʌİȪșȣȞȘ İȞĮıȤȩȜȘıȒ IJȘȢ İ IJȠ ĮȞIJȚțİȓİȞȠ ʌȡȩıijİȡİ • Earthing Systems
ıIJȘȞ ǼȁǼȂȀȅ IJİȤȞȠȖȞȦıȓĮ, İʌİȚȡȓĮ țĮȚ İȟİȚįȓțİȣıȘ ʌȐȞȦ ıIJĮ șȑĮIJĮ
ĮıijȐȜİȚĮȢ țĮȚ ʌȡȠıIJĮıȓĮȢ ĮȞșȡȫʌȦȞ, țĮIJĮıțİȣȫȞ țĮȚ İȖțĮIJĮıIJȐıİȦȞ Over the years, ELEMKO has acquired fundamental know-how,
ȣȥȘȜȫȞ ʌȡȠįȚĮȖȡĮijȫȞ țĮȚ ĮʌĮȚIJȒıİȦȞ Įʌȩ IJȚȢ țĮIJĮıIJȡȠijȚțȑȢ ıȣȞȑʌİȚİȢ experience and specialisation in the protection of people, structures
IJȠȣ țİȡĮȣȞȠȪ. and equipment with high specifications and demands against the
catastrophic consequences of lightning.
ȉĮ ȚıȤȣȡȐ ĮȣIJȐ ȩʌȜĮ ıİ ıȣȞįȣĮıȩ İ IJȚȢ ȖİȡȑȢ ȠȚțȠȞȠȚțȑȢ ȕȐıİȚȢ ʌȠȣ ȑȤİȚ
Ș ǼȁǼȂȀȅ, IJȘȞ İȣĮȚıșȘıȓĮ țĮȚ İʌȚȠȞȒ IJȘȢ ıİ șȑĮIJĮ ʌȠȚȩIJȘIJĮȢ, IJȠ All the above strong arms are coupled with strong financial
İȡȐțȚ țĮȚ IJȘȞ ĮȖȐʌȘ IJȦȞ ĮȞșȡȫʌȦȞ ʌȠȣ IJȘ ıIJİȜİȤȫȞȠȣȞ, IJȘ įȚĮȡțȒ fundamental, the sensitivity and insistence on quality, the passion and
İȞȘȑȡȦıȘ ʌȐȞȦ ıİ ȩȜİȢ IJȚȢ İȟİȜȓȟİȚȢ ʌȠȣ ĮijȠȡȠȪȞ IJȠ ĮȞIJȚțİȓİȞȩ IJȘȢ, IJȘ love of the people who staffed, the continuous update on all
ıȣȞİȤȒ İʌȚȩȡijȦıȘ IJȠȣ ʌȡȠıȦʌȚțȠȪ IJȘȢ, IJȘ İIJĮijȠȡȐ IJȦȞ ȖȞȫıİȦȞ țĮȚ developments that concern our matters, the constant training of
İʌİȚȡȚȫȞ IJȘȢ ʌȡȠȢ IJȠȞ IJİȤȞȚțȩ țȩıȠ ȑıĮ Įʌȩ IJĮ ıİȚȞȐȡȚĮ țĮȚ IJĮ IJİȤȞȚțȐ personnel, the transfer of knowledge and experiences to the world
IJȘȢ ȕȚȕȜȓĮ țĮȚ ʌȐȞȦ Įʌ' ȩȜĮ IJȠȞ İʌĮȖȖİȜĮIJȚıȩ țĮȚ IJȠ ıİȕĮıȩ İ IJȠȞ through technical seminars and technical books, leading
ȠʌȠȓȠ ĮȞIJȚİIJȦʌȓȗİȚ IJȠȣȢ ʌİȜȐIJİȢ IJȘȢ, IJȘȞ ȑȤȠȣȞ țĮșȚİȡȫıİȚ ȦȢ ȘȖİIJȚțȒ developments and creating lasting relationships of trust.
İIJĮȚȡİȓĮ ıIJȠȞ țȜȐįȠ IJȘȢ, ȠįȘȖȫȞIJĮȢ IJȚȢ İȟİȜȓȟİȚȢ țĮȚ įȘȚȠȣȡȖȫȞIJĮȢ
ĮțȡȠȤȡȩȞȚİȢ ıȤȑıİȚȢ İʌȚıIJȠıȪȞȘȢ. The company's share capital amounts to 2.930.000€, making
ELEMKO among the most financially powerful companies in
ȉȠ İIJȠȤȚțȩ țİijȐȜĮȚȠ IJȘȢ ǼȁǼȂȀȅ ĮȞȑȡȤİIJĮȚ ıIJĮ 2.930.000 € Europe in our field.
ıȣȖțĮIJĮȜȑȖȠȞIJĮȢ IJȘȞ ȠȚțȠȞȠȚțȐ İIJĮȟȪ IJȦȞ ʌȚȠ įȣȞĮȚțȫȞ İIJĮȚȡİȚȫȞ IJȘȢ
ǼȣȡȫʌȘȢ ıIJȠ ȤȫȡȠ IJȘȢ. ELEMKO's premises of 3.600 sqm in which houses all the services
and activities are 24.067 sqm private land. Specifically, the company
ȅȚ țIJȚȡȚĮțȑȢ İȖțĮIJĮıIJȐıİȚȢ is headquartered in Metamorphosis, in Attica, while in Thiva is the
IJȘȢ ǼȁǼȂȀȅ 3.600 IJ ıIJȚȢ "Research Center for tests and Developments" , which is the largest
ȠʌȠȓİȢ ıIJİȖȐȗȠȞIJĮȚ ȩȜİȢ ȠȚ ELEMKO's investment carried out exclusively by Elemko' s funds.
ȣʌȘȡİıȓİȢ țĮȚ įȡĮıIJȘȡȚȩIJȘIJİȢ Research Center for tests and Developments of our company is one of
IJȘȢ ȕȡȓıțȠȞIJĮȚ ıİ 24.067 IJ the four in all Europe and has been accredited according to standards
ȚįȚȩțIJȘIJȘȢ ȖȘȢ. ȈȣȖțİțȡȚȑȞĮ EN - ISO/ IEC 17025.In Thessaloniki takes place a branch of the
Ș ȑįȡĮ IJȘȢ İIJĮȚȡİȓĮȢ ȕȡȓıțİIJĮȚ company, to serve the needs of our customers in Northern Greece
ıIJȘ ȂİIJĮȩȡijȦıȘ ǹIJIJȚțȒȢ, more directly.
İȞȫ ıIJȘ ĬȒȕĮ ȕȡȓıțİIJĮȚ IJȠ
«ǼȡİȣȞȘIJȚțȩ ȀȑȞIJȡȠ ¨ȠțȚȫȞ
ȀİȡĮȣȞȚțȫȞ ȇİȣȐIJȦȞ țĮȚ GUARANTEE
ȊȥȘȜȫȞ ȉȐıİȦȞ țĮșȫȢ țĮȚ ȆȚıIJȠʌȠȓȘıȘȢ ȈȣıIJȘȐIJȦȞ & ¨ȚĮIJȐȟİȦȞ
ʌȡȠıIJĮıȓĮȢ Įʌȩ țİȡĮȣȞȠȪȢ», ʌȠȣ ĮʌȠIJİȜİȓ IJȘ ıȘĮȞIJȚțȩIJİȡȘ Įʌȩ IJȚȢ ELEMKO's experience for more than 40 years
İʌİȞįȪıİȚȢ IJȘȢ ǼȁǼȂȀȅ Ș ȠʌȠȓĮ ȣȜȠʌȠȚȒșȘțİ ĮʌȠțȜİȚıIJȚțȐ țĮȚ ȩȞȠ Įʌȩ • The scientific and technical knowledge of ELEMKO's staff that
țİijȐȜĮȚĮ IJȘȢ İIJĮȚȡİȓĮȢ. ȉȠ «ǼȡİȣȞȘIJȚțȩ ȀȑȞIJȡȠ ¨ȠțȚȫȞ» IJȘȢ ǼȁǼȂȀȅ have been acquired through continuous training.
İȓȞĮȚ ȑȞĮ Įʌȩ IJĮ IJȑııİȡĮ ıIJȘȞ ǼȣȡȫʌȘ țĮȚ ȑȤİȚ įȚĮʌȚıIJİȣșİȓ ıȪijȦȞĮ İ • The results of the research we carry out at ELEMKO's Testing
IJȚȢ ĮʌĮȚIJȒıİȚȢ IJȠȣ ȆȡȠIJȪʌȠȣ EN - ISO/ IEC 17025. ȈIJȘ ĬİııĮȜȠȞȓțȘ and Certification Research Center
ȕȡȓıțİIJĮȚ ʌĮȡȐȡIJȘĮ IJȘȢ İIJĮȚȡİȓĮȢ, ʌȡȠțİȚȑȞȠȣ ȞĮ İȟȣʌȘȡİIJȠȪȞIJĮȚ ȐİıĮ • ELEMKO's long lasting cooperation with university and
ȠȚ ĮȞȐȖțİȢ IJȦȞ ʌİȜĮIJȫȞ IJȘȢ ıIJȘ Ǻ. ǼȜȜȐįĮ. private research centers in Greece, France, Belgium,
Switzerland, the USA and the UK.
ǼīīȊǾȈǾ • The adoption and strict implementation of European and
International Standards on Lightning Protection Components,
• ȉĮ 40 țĮȚ ʌȜȑȠȞ ȤȡȩȞȚĮ İʌİȚȡȓĮȢ IJȘȢ ǼȁǼȂȀȅ Surge Protection Devices, Earthing
• Ǿ İʌȚıIJȘȠȞȚțȒ țĮȚ IJİȤȞȚțȒ ȖȞȫıȘ IJȠȣ ʌȡȠıȦʌȚțȠȪ IJȘȢ • The adherence to the procedures of the ISO 9001
ǼȁǼȂȀȅ ʌȠȣ ȑȤİȚ ĮʌȠțIJȘșİȓ İ įȚĮȡțȒ İțʌĮȓįİȣıȘ • The accreditation of ELEMKO's laboratory according to
• ȉĮ ĮʌȠIJİȜȑıĮIJĮ IJȘȢ ȑȡİȣȞĮȢ ʌȠȣ įȚİȟȐȖȠȞIJĮȚ ıIJȠ ǼȡİȣȞȘIJȚțȩ Standard EN-ISO/IEC 17025
ȀȑȞIJȡȠ ¨ȠțȚȫȞ țĮȚ ȆȚıIJȠʌȠȓȘıȘȢ IJȘȢ ǼȁǼȂȀȅ
• Ǿ ĮțȡȩȤȡȠȞȘ ıȣȞİȡȖĮıȓĮ IJȘȢ ǼȁǼȂȀȅ İ ǼȡİȣȞȘIJȚțȐ ȀȑȞIJȡĮ
ȆĮȞİʌȚıIJȘȓȦȞ țĮȚ ǼʌȚȤİȚȡȒıİȦȞ IJȘȢ ǼȜȜȐįĮȢ, īĮȜȜȓĮȢ, ǺİȜȖȓȠȣ,
ǼȜȕİIJȓĮȢ, ǾȆǹ țĮȚ ȂİȖȐȜȘȢ ǺȡİIJĮȞȓĮȢ DESIGNS & STUDIES
ȆĮȡȐȜȜȘȜĮ İ:
• ȉȘȞ ȣȚȠșȑIJȘıȘ țĮȚ IJȘȞ ʌȚıIJȒ İijĮȡȠȖȒ IJȦȞ ǼȣȡȦʌĮȧțȫȞ țĮȚ ELEMKO designs and studies
¨ȚİșȞȫȞ ȆȡȠIJȪʌȦȞ ʌȠȣ ĮijȠȡȠȪȞ İȟĮȡIJȒĮIJĮ ǹȞIJȚțİȡĮȣȞȚțȒȢ comply strictly with the current Euro-
ȆȡȠıIJĮıȓĮȢ, įȚĮIJȐȟİȚȢ ȆȡȠıIJĮıȓĮȢ Įʌȩ ȀȡȠȣıIJȚțȑȢ pean and International Standards.
ȊʌİȡIJȐıİȚȢ, īİȚȫıİȚȢ Frequently heralded as pioneering,
• ȉȘȞ IJȒȡȘıȘ IJȦȞ įȚĮįȚțĮıȚȫȞ IJȠȣ ȈȣıIJȒĮIJȠȢ ¨ȚĮȤİȓȡȚıȘȢ with a number of them having been
ȆȠȚȩIJȘIJĮȢ ISO 9001 presented at International scientific
• ȉȘ įȚĮʌȓıIJİȣıȘ IJȠȣ ǼȡȖĮıIJȘȡȓȠȣ IJȘȢ ǼȁǼȂȀȅ ıȪijȦȞĮ İ conferences, they include:
IJȚȢ ĮʌĮȚIJȒıİȚȢ IJȠȣ ȆȡȠIJȪʌȠȣ EN - ISO/IEC 17025 • Protection of common and
ĮʌȠIJİȜȠȪȞ İȖȖȪȘıȘ ȖȚĮ IJȘȞ ʌȠȚȩIJȘIJĮ IJȦȞ ʌĮȡĮȖȩİȞȦȞ ʌȡȠȧȩȞIJȦȞ țĮȚ special structures from lightning such as Wind Farms and
ʌĮȡİȤȠȑȞȦȞ ȣʌȘȡİıȚȫȞ IJȘȢ İIJĮȚȡİȓĮȢ. Photovoltaic installations
ȂǼȁǼȉǼȈ • Surge Overvoltage Protection of electrical and electronic systems
• Surge Overvoltage Protection of telecommunications and
Ǿ ǼȁǼȂȀȅ İțʌȠȞİȓ İȜȑIJİȢ telemetry systems
ĮțȠȜȠȣșȫȞIJĮȢ ĮȣıIJȘȡȐ IJȚȢ • Earthing Systems of common and special structures such as Wind
ĮʌĮȚIJȒıİȚȢ IJȦȞ IJİȜİȣIJĮȓȦȞ Farms and Photovoltaic installations
ȚıȤȣȩȞIJȦȞ ǼȣȡȦʌĮȧțȫȞ țĮȚ • Earthing Systems of Substations according to Standards IEEE std
¨ȚİșȞȫȞ ȆȡȠIJȪʌȦȞ. ȉȑIJȠȚİȢ 80 and IEEEstd 81
İȜȑIJİȢ ȑȤȠȣȞ ĮȞĮțȠȚȞȦșİȓ ıİ • Financial / technical studies of interrelated projects
įȚİșȞȒ İʌȚıIJȘȠȞȚțȐ ıȣȞȑįȡȚĮ, • The drawing up of technical specification of offers
ȑ ȤȠ ȣ Ȟ ȤĮ ȡ Į ț IJ Ș ȡ Ț ı IJ İ ȓ Ȧ Ȣ
ʌȡȦIJȠʌȠȡȚĮțȑȢ țĮȚ ȑȤȠȣȞ
İijĮȡȠıIJİȓ ıİ ʌȜȒșȠȢ ȑȡȖȦȞ, țĮȚ ıİ ʌİȡȚʌIJȫıİȚȢ ȩʌȦȢ: TECHNICAL SUPPORT
• ȆȡȠıIJĮıȓĮȢ Įʌȩ țİȡĮȣȞȠȪȢ țȠȚȞȫȞ țĮȚ İȚįȚțȫȞ țĮIJĮıțİȣȫȞ, ELEMKO’s engineers are always available to help you choose the
ʌȤ ǹȚȠȜȚțȐ țĮȚ ĭȦIJȠȕȠȜIJĮȧțȐ ʌȐȡțĮ. most appropriate technical and financial solution:
• ȆȡȠıIJĮıȓĮȢ Įʌȩ țȡȠȣıIJȚțȑȢ ȣʌİȡIJȐıİȚȢ ȘȜİțIJȡȚțȫȞ țĮȚ
ȘȜİțIJȡȠȞȚțȫȞ ıȣıIJȘȐIJȦȞ. • Behind every telephone call you make
• ȆȡȠıIJĮıȓĮȢ Įʌȩ țȡȠȣıIJȚțȑȢ ȣʌİȡIJȐıİȚȢ IJȘȜİʌȚțȠȚȞȦȞȚĮțȫȞ țĮȚ • At your worksite
IJȘȜİİIJȡȚțȫȞ ıȣıIJȘȐIJȦȞ. • At your facilities
• ȈȣıIJȘȐIJȦȞ ȖİȓȦıȘȢ țȠȚȞȫȞ țĮȚ İȚįȚțȫȞ țĮIJĮıțİȣȫȞ, ʌȤ • In your building
ǹȚȠȜȚțȐ țĮȚ ĭȦIJȠȕȠȜIJĮȧțȐ ʌȐȡțĮ.
• ȈȣıIJȘȐIJȦȞ ȖİȓȦıȘȢ ȊʌȠıIJĮșȫȞ ıȪijȦȞĮ İ IJĮ ʌȡȩIJȣʌĮ Everybody is here to help you.
ǿǼǼǼ std 80, ʌȡȩIJȣʌĮ ǿǼǼǼ std 81.
• ȅȚțȠȞȠȠIJİȤȞȚțȫȞ İȜİIJȫȞ ıȣȞĮijȫȞ ȑȡȖȦȞ.
• ȈȪȞIJĮȟȘȢ IJİȤȞȚțȫȞ ʌȡȠįȚĮȖȡĮijȫȞ ʌȡȠıijȠȡȫȞ. INSPECTION
Ǿ įȚĮıijȐȜȚıȘ IJȘȢ ʌȠȚȩIJȘIJĮȢ IJȦȞ ĮȞȦIJȑȡȦ ȣʌȘȡİıȚȫȞ IJȘȢ ǼȁǼȂȀȅ Applied European and
İȟĮıijĮȜȓȗİIJĮȚ ȑıȦ IJȠȣ ȈȣıIJȒĮIJȠȢ ¨ȚĮȤİȓȡȚıȘȢ ȆȠȚȩIJȘIJĮȢ ISO 9001. International Standards
require the regular
ȉǼȋȃǿȀǾ ȊȆȅȈȉǾȇǿȄǾ inspection of installed
Lightning Protection
ȅȚ ȂȘȤĮȞȚțȠȓ IJȘȢ ǼȁǼȂȀȅ İȓȞĮȚ ʌȐȞIJĮ ʌȡȩșȣȠȚ ȞĮ ıĮȢ ȕȠȘșȒıȠȣȞ Systems (internal and
ȞĮ İʌȚȜȑȟİIJİ IJȘȞ țĮIJĮȜȜȘȜȩIJİȡȘ IJİȤȞȚțȒ țĮȚ ȠȚțȠȞȠȚțȒ ȜȪıȘ: external) and Surge
Protection Systems,
• ȆȓıȦ Įʌȩ țȐșİ IJȘȜİijȦȞȚțȒ ȖȡĮȒ ʌȠȣ țĮȜİȓIJİ. depending on the
• ȈIJȠ ȤȫȡȠ IJȠȣ İȡȖȠIJĮȟȓȠȣ ıĮȢ. required level of protection for the structure, to guarantee their
• ȈIJȚȢ İȖțĮIJĮıIJȐıİȚȢ ıĮȢ. readiness and reliability.
• ȈIJȠ țIJȓȡȚȩ ıĮȢ.
ȀĮȚ ȖİȞȚțȐ ȕȡȓıțȠȞIJĮȚ ȩȜȠȚ İįȫ ȖȚĮ İıȐȢ. The inspection involve checking:
• That the system satisfies applied Standards
ǼȆǿĬǼȇǾȈǾ • That the system components are in good condition and adhere to
existing Standards
ȉĮ ȚıȤȪȠȞIJĮ ǼȣȡȦʌĮȧțȐ țĮȚ ¨ȚİșȞȒ ȆȡȩIJȣʌĮ ĮʌĮȚIJȠȪȞ IJȘȞ İʌȚșİȫȡȘıȘ • That any new parts of the building are covered by the existing
IJȦȞ İȖțĮIJİıIJȘȑȞȦȞ ȈȣıIJȘȐIJȦȞ ǹȞIJȚțİȡĮȣȞȚțȒȢ ȆȡȠıIJĮıȓĮȢ, system
(ǼȟȦIJİȡȚțȠȪ – ǼıȦIJİȡȚțȠȪ ȈȣıIJȒĮIJȠȢ), țĮșȫȢ țĮȚ IJȘȢ İȖțĮIJȐıIJĮıȘȢ • That surge overvoltage protection equipment is in good condition
ȆȡȠıIJĮıȓĮȢ Įʌȩ ȀȡȠȣıIJȚțȑȢ ȊʌİȡIJȐıİȚȢ ıİ IJĮțIJȐ ȤȡȠȞȚțȐ įȚĮıIJȒĮIJĮ, • That new machinery which has been installed is protected against
ĮȞȐȜȠȖĮ İ IJȘȞ ĮʌĮȚIJȠȪİȞȘ ıIJȐșȘ ʌȡȠıIJĮıȓĮȢ IJȘȢ țĮIJĮıțİȣȒȢ, ȑIJıȚ surge overvoltage
ȫıIJİ ȞĮ İȟĮıijĮȜȓȗİIJĮȚ Ș İIJȠȚȩIJȘIJĮ țĮȚ Ș ĮȟȚȠʌȚıIJȓĮ IJȠȣȢ.
Inspections are carried out by ELEMKO’s highly trained engineers
ȅȚ İʌȚșİȦȡȒıİȚȢ ʌİȡȚȜĮȕȐȞȠȣȞ İȜȑȖȤȠȣȢ İȐȞ: and technicians, who have a complete knowledge of the applied
• ȉȠ ȈȪıIJȘĮ ȚțĮȞȠʌȠȚİȓ IJĮ IJİȜİȣIJĮȓĮ ȚıȤȪȠȞIJĮ ȆȡȩIJȣʌĮ. Standards for Lightning Protection Systems and many years of
• ȉĮ İȟĮȡIJȒĮIJĮ IJȠȣ ȈȣıIJȒĮIJȠȢ İȣȡȓıțȠȞIJĮȚ ıİ țĮȜȒ țĮIJȐıIJĮıȘ experience in designing and installing them. They use highly accurate
țĮȚ ȚțĮȞȠʌȠȚȠȪȞ IJĮ ȚıȤȪȠȞIJĮ ȆȡȩIJȣʌĮ. measuring instruments and devices that are regularly calibrated at
• ȃȑİȢ ʌȡȠıșȒțİȢ IJȠȣ țIJȚȡȓȠȣ țĮȜȪʌIJȠȞIJĮȚ Įʌȩ IJȠ ȣʌȐȡȤȠȞ special laboratories.
ȈȪıIJȘĮ.
• ȅȚ įȚĮIJȐȟİȚȢ ʌȡȠıIJĮıȓĮȢ Įʌȩ țȡȠȣıIJȚțȑȢ ȣʌİȡIJȐıİȚȢ ȕȡȓıțȠȞIJĮȚ
ıİ țĮȜȒ țĮIJȐıIJĮıȘ. PROJECT SUPERVISION
• ȃȑĮ ȘȤĮȞȒĮIJĮ ʌȠȣ ȑȤȠȣȞ İȖțĮIJĮıIJĮșİȓ ʌȡȠıIJĮIJİȪȠȞIJĮȚ Įʌȩ
ȣʌİȡIJȐıİȚȢ. Project supervision by ELEMKO means constantly checking that the
ȅȚ İʌȚșİȦȡȒıİȚȢ ʌȡĮȖĮIJȠʌȠȚȠȪȞIJĮȚ Įʌȩ IJȠ ȐȡIJȚĮ İțʌĮȚįİȣȑȞȠ design is properly followed and adhered to, and that the appropriate
ʌȡȠıȦʌȚțȩ IJȘȢ ǼȁǼȂȀȅ, ȂȘȤĮȞȚțȠȪȢ țĮȚ ȉİȤȞȚțȠȪȢ İ ʌȜȒȡȘ ȖȞȫıȘ materials and equipment are used as laid down in European and
IJȦȞ ȚıȤȣȩȞIJȦȞ ȆȡȠIJȪʌȦȞ ȖȚĮ ȈȣıIJȒĮIJĮ ǹȞIJȚțİȡĮȣȞȚțȒȢ ȆȡȠıIJĮıȓĮȢ, International Standards, thus
țĮșȫȢ țĮȚ ĮțȡȠȤȡȩȞȚĮ İʌİȚȡȓĮ ıȤİįȚĮıȠȪ țĮȚ İȖțĮIJȐıIJĮıȒȢ IJȠȣȢ. ensuring the reliability of the
ȅ ȤȡȘıȚȠʌȠȚȠȪİȞȠȢ İȟȠʌȜȚıȩȢ ĮʌȠIJİȜİȓIJĮȚ Įʌȩ ȩȡȖĮȞĮ țĮȚ Lightning Protection System,
ıȣıțİȣȑȢ ȑIJȡȘıȘȢ ȣȥȘȜȒȢ ĮțȡȚȕİȓĮȢ, IJĮ ȠʌȠȓĮ ȕĮșȠȞȠȠȪȞIJĮȚ the Surge Protection System
IJĮțIJȚțȐ ıİ İȚįȚțȐ İȡȖĮıIJȒȡȚĮ įȚĮțȡȓȕȦıȘȢ. and the Earthing Systems.
Project supervision by our
ǼȆǿǺȁǼȌǾ & ȆȇǹīȂǹȉȅīȃȂȅȈȊȃǾ Ǽȇīȃ company guarantees quality,
reliability and durability.
Ǿ İʌȓȕȜİȥȘ ȑȡȖȦȞ Įʌȩ IJȘȞ ǼȁǼȂȀȅ ıȘĮȓȞİȚ ıȣȞİȤȒ ȑȜİȖȤȠ ȖȚĮ ʌȚıIJȒ
İijĮȡȠȖȒ - IJȒȡȘıȘ IJȘȢ İȜȑIJȘȢ țĮȚ IJȘȢ țĮIJĮȜȜȘȜȩIJȘIJĮȢ IJȦȞ
ȤȡȘıȚȠʌȠȚȠȪİȞȦȞ ȣȜȚțȫȞ țĮȚ įȚĮIJȐȟİȦȞ ȩʌȦȢ ĮȣIJȐ ȠȡȓȗȠȞIJĮȚ Įʌȩ IJĮ
ǼȣȡȦʌĮȧțȐ țĮȚ ¨ȚİșȞȒ ȆȡȩIJȣʌĮ, İȟĮıijĮȜȓȗȠȞIJĮȢ ȑIJıȚ IJȘȞ ĮȟȚȠʌȚıIJȓĮ
IJȠȣ İȖțĮșȚıIJȐİȞȠȣ ȈȣıIJȒĮIJȠȢ ǹȞIJȚțİȡĮȣȞȚțȒȢ ȆȡȠıIJĮıȓĮȢ,
ȆȡȠıIJĮıȓĮȢ Įʌȩ ȀȡȠȣıIJȚțȑȢ ȊʌİȡIJȐıİȚȢ țĮȚ ȈȣıIJȘȐIJȦȞ īİȚȫıİȦȞ.
Ǿ İʌȓȕȜİȥȘ ȑȡȖȦȞ Įʌȩ IJȘȞ ǼȁǼȂȀȅ ȑȡȤİIJĮȚ ȞĮ ıijȡĮȖȓıİȚ IJȘȞ
ʌȠȚȩIJȘIJĮ , IJȘȞ ĮȟȚȠʌȚıIJȓĮ țĮȚ IJȘ ĮțȡȠȗȦȓĮ IJȠȣȢ.
A ÁÐÁÃÙÃÏÉ ÊÑÏÕÓÔÉÊÙÍ ÕÐÅÑÔÁÓÅÙÍ SURGE PROTECTIVE DEVICES
ǼȚıĮȖȦȖȒ Introduction
ȈIJȩȤȠȢ IJȠȣ ʌĮȡȩȞIJȠȢ țĮIJĮȜȩȖȠȣ İȓȞĮȚ ȞĮ țĮIJĮıIJİȓ ȑȞĮ ȤȡȒıȚȠ İȡ- The target of the present catalogue is to become a useful tool for every
ȖĮȜİȓȠ ȖȚĮ țȐșİ İȜİIJȘIJȒ, İȖțĮIJĮıIJȐIJȘ țĮȚ İʌȚȕȜȑʌȠȞIJĮ ȑȡȖȠȣ ȖȚĮ IJȘ designer, installer and project supervisor in order to select, install and
ıȦıIJȒ, ĮıijĮȜȒ İʌȚȜȠȖȒ ĮȜȜȐ țĮȚ İijĮȡȠȖȒ ȣȜȚțȫȞ țĮȚ įȚĮIJȐȟİȦȞ use the appropriate product to provide maximum safety and protection
ʌȡȠıIJĮıȓĮȢ Įʌȩ țȡȠȣıIJȚțȑȢ ȣʌİȡIJȐıİȚȢ. against surge overvoltages.
ȅ ʌĮȡȩȞ țĮIJȐȜȠȖȠȢ ĮʌĮȡIJȓȗİIJĮȚ Įʌȩ IJȑııİȡĮ ȑȡȘ, ĮȞĮȜȣIJȚțȐ IJȠ The present catalogue is divided into four main parts, in more detail
țȐșİ ȑȡȠȢ ʌİȡȚȑȤİȚ: each part contain:
ȂȑȡȠȢ A: ǹʌĮȖȦȖȠȓ țȡȠȣıIJȚțȫȞ ȣʌİȡIJȐıİȦȞ İȞİȡȖİȚĮțȫȞ Part A: Surge protective devices SPDs connected to power systems
įȚțIJȪȦȞ Medium voltage surge arresters, industrial type SPDs, low voltage
ǹʌĮȖȦȖȠȓ ȑıȘȢ IJȐıȘȢ, ĮʌĮȖȦȖȠȓ ȕȚȠȘȤĮȞȚțȠȪ IJȪʌȠȣ, ĮʌĮȖȦȖȠȓ SPDs, DC surge protectors
ȤĮȘȜȒȢ IJȐıȘȢ țĮȚ ĮʌĮȖȦȖȠȓ ıȣȞİȤȠȪȢ ȡİȪĮIJȠȢ
Part B: Surge protective devices SPDs connected to information
ȂȑȡȠȢ B: ǹʌĮȖȦȖȠȓ țȡȠȣıIJȚțȫȞ ȣʌİȡIJȐıİȦȞ ıȣıIJȘȐIJȦȞ technology systems
İʌİȟİȡȖĮıȓĮȢ ʌȜȘȡȠijȠȡȚȫȞ SPDs for analogue and digital systems, SPDs for telecommunication
ǹʌĮȖȦȖȠȓ ĮȞĮȜȠȖȚțȫȞ țĮȚ ȥȘijȚĮțȫȞ ıȘȐIJȦȞ, ĮʌĮȖȦȖȠȓ IJȘȜİijȦ- systems, SPDs for RF applications, SPDs for combined protection
ȞȚțȫȞ ıȘȐIJȦȞ, ĮʌĮȖȦȖȠȓ ȣȥȘȜȫȞ ȡĮįȚȠıȣȤȞȠIJȒIJȦȞ țĮȚ ĮʌĮȖȦȖȠȓ
ıȣȞįȣĮıIJȚțȒȢ ʌȡȠıIJĮıȓĮȢ Part C: Equipotential bonding and Isolation Spark Gaps ISGs
Direct equipotential bonding, equipotential bonding through isolation
ȂȑȡȠȢ ī: ǿıȠįȣȞĮȚțȑȢ ıȣȞįȑıİȚȢ țĮȚ ıʌȚȞșȘȡȚıIJȑȢ ĮʌȠȩȞȦıȘȢ spark gaps, explosion proof isolation spark gaps, SPDs inspection
DZİıİȢ ȚıȠįȣȞĮȚțȑȢ ıȣȞįȑıİȚȢ, ıʌȚȞșȘȡȚıIJȑȢ ĮʌȠȩȞȦıȘȢ, ıʌȚȞ- instruments
șȘȡȚıIJȑȢ ĮʌȠȩȞȦıȘȢ ĮȞIJȚİțȡȘțIJȚțȠȪ IJȪʌȠȣ țĮȚ ȩȡȖĮȞĮ İȜȑȖȤȠȣ
ĮʌĮȖȦȖȫȞ Part D: Shielding techniques against electromagnetic fields
Shielded cable trays, shielded panels, electromagnetic shielding
ȂȑȡȠȢ ¨: ȂȑıĮ șȦȡȐțȚıȘȢ ȘȜİțIJȡȠĮȖȞȘIJȚțȫȞ ʌİįȓȦȞ against high AC/DC currents
ĬȦȡĮțȚıȑȞĮ țĮȞȐȜȚĮ, șȦȡĮțȚıȑȞĮ ʌȜĮȓıȚĮ țĮȚ ȘȜİțIJȡȠĮȖȞȘIJȚțȒ
șȦȡȐțȚıȘ țȜİȚıIJȫȞ ȤȫȡȦȞ Įʌȩ ȚıȤȣȡȐ AC/DC ȡİȪĮIJĮ All the products which are described in the present catalogue fulfil the
requirements of the latest editions of the valid European (EN),
ǵȜĮ IJĮ ȣȜȚțȐ țĮȚ ȠȚ įȚĮIJȐȟİȚȢ ʌȠȣ ʌİȡȚȖȡȐijȠȞIJĮȚ ıIJȠȞ ʌĮȡȩȞ International (IEC) and National (ELOT) standards.
țĮIJȐȜȠȖȠ ȚțĮȞȠʌȠȚȠȪȞ IJȚȢ ĮʌĮȚIJȒıİȚȢ IJȦȞ IJİȜİȣIJĮȓȦȞ İțįȩıİȦȞ IJȦȞ
ȚıȤȪȠȞIJȦȞ ǼȣȡȦʌĮȧțȫȞ (EN), ¨ȚİșȞȫȞ (IEC) țĮȚ ǼșȞȚțȫȞ (Ǽȁȅȉ) The main reason of preparing this catalogue specifically for surge
ʌȡȠIJȪʌȦȞ. protection arrives from the issue of the new European and International
series of standards EN / IEC 62305, which describe the design
Ǿ ĮȞȐȖțȘ ıȪȞIJĮȟȘȢ IJȠȣ İȟİȚįȚțİȣȑȞȠȣ țĮIJĮȜȩȖȠȣ ĮijȠȡȐ ıIJȘȞ ʌȜȒȡȘ requirements for a lightning protection system and in particular the
țȐȜȣȥȘ IJȠȣ țİijĮȜĮȓȠȣ ʌȡȠıIJĮıȓĮ Įʌȩ țȡȠȣıIJȚțȑȢ ȣʌİȡIJȐıİȚȢ, Ș standard EN / IEC 62305 - 4 which outlines the design requirements
ȠʌȠȓĮ Ȓȡșİ İIJȐ Įʌȩ IJȘȞ ȑțįȠıȘ IJȦȞ ȞȑȦȞ ʌȡȠIJȪʌȦȞ ıȤİįȚĮıȠȪ İ- for the internal lightning protection system including surge protection.
ȞȩȢ ȠȜȠțȜȘȡȦȑȞȠȣ ıȣıIJȒĮIJȠȢ ĮȞIJȚțİȡĮȣȞȚțȒȢ ʌȡȠıIJĮıȓĮȢ ıİȚȡȐȢ
Ǽȁȅȉ Ǽȃ 62305 țĮȚ ıȣȖțİțȡȚȑȞĮ IJȠȣ ʌȡȠIJȪʌȠȣ Ǽȁȅȉ Ǽȃ 62305 - 4, In conjunction with the new series of design standards there where
IJȠ ȠʌȠȓȠ șȑIJİȚ ȞȑİȢ ȕȐıİȚȢ ȖȚĮ IJȠ ıȤİįȚĮıȩ IJȠȣ İıȦIJİȡȚțȠȪ ıȣ- made major amendments to the series of standards describing testing
ıIJȒĮIJȠȢ ĮȞIJȚțİȡĮȣȞȚțȒȢ ʌȡȠıIJĮıȓĮȢ țĮȚ IJȘȢ ʌȡȠıIJĮıȓĮȢ Įʌȩ requirements for components and devices that are used in a lightning
țȡȠȣıIJȚțȑȢ ȣʌİȡIJȐıİȚȢ. and surge protection system so that both design and testing standards
are inline with each other.
ȆĮȡȐȜȜȘȜĮ Įȗȓ İ IJĮ ȞȑĮ ʌȡȩIJȣʌĮ ıȤİįȚĮıȠȪ ĮțȠȜȠȪșȘıĮȞ țĮȚ
ȞȑİȢ İțįȩıİȚȢ IJȦȞ ȚıȤȣȩȞIJȦȞ ʌȡȠIJȪʌȦȞ įȠțȚȫȞ ȣȜȚțȫȞ ĮȞIJȚ- In particular there are amendments to the European series of standards
țİȡĮȣȞȚțȒȢ ʌȡȠıIJĮıȓĮȢ ıİȚȡȫȞ Ǽȁȅȉ Ǽȃ 50164 (İȟĮȡIJȒĮIJĮ İȟȦ- EN 50164 (testing requirements for components used in external
IJİȡȚțȠȪ ıȣıIJȒĮIJȠȢ ĮȞIJȚțİȡĮȣȞȚțȒȢ ʌȡȠıIJĮıȓĮȢ țĮȚ ȚıȠįȣȞĮȚțȫȞ lightning protection and equipotential bonding) as well as in EN 61643
ıȣȞįȑıİȦȞ) țĮȚ Ǽȁȅȉ Ǽȃ 61643 (įȚĮIJȐȟİȚȢ ʌȡȠıIJĮıȓĮȢ Įʌȩ series of standards (testing requirements of power and telecom surge
ȣʌİȡIJȐıİȚȢ İȞİȡȖİȚĮțȠȪ țĮȚ IJȘȜİʌȚțȠȚȞȦȞȚĮțȠȪ įȚțIJȪȠȣ) ȫıIJİ ȞĮ protective devices).
ȣʌȐȡȤİȚ ʌȜȒȡȘ İȞĮȡȩȞȚıȘ İIJĮȟȪ ĮʌĮȚIJȒıİȦȞ ıȤİįȚĮıȠȪ țĮȚ
ȣȜȚțȫȞ. ELEMKO SA as always is 100% inline with the new requirements of
the standards and we are ready to perform training and to update all our
Ǿ ǼȁǼȂȀȅ ǹǺǼǼ ʌȚıIJȒ ıIJȚȢ ȣʌȠıȤȑıİȚȢ IJȘȢ ʌȡȠȢ IJȠȣȢ ʌİȜȐIJİȢ IJȘȢ customers to the new standards. Additionally ELEMKO SA has a
İȓȞĮȚ ȑIJȠȚȘ ȞĮ IJȠȣȢ İȞȘİȡȫıİȚ ȖȚĮ IJȚȢ ȞȑİȢ ĮʌĮȚIJȒıİȚȢ țĮȚ IJȚȢ complete range of products fit for every purpose that might be required
ĮȜȜĮȖȑȢ ʌȠȣ ȑȤȠȣȞ ijȑȡİȚ ȠȚ ȞȑİȢ İțįȩıİȚȢ IJȦȞ ʌȡȠIJȪʌȦȞ țĮșȫȢ İʌȓıȘȢ according to the new needs.
įȚĮșȑIJİȚ ʌȜȒȡȘ ȖțȐĮ ĮȟȚȩʌȚıIJȦȞ țĮȚ ʌȠȚȠIJȚțȫȞ ʌȡȠȧȩȞIJȦȞ ȫıIJİ ȞĮ
țĮȜȪȥİȚ ȩȜİȢ IJȚȢ ȞȑİȢ ĮȞȐȖțİȢ. At the technical introduction of the present catalogue the reader can
find useful information regarding the application and selection
ȈIJȘȞ İȚıĮȖȦȖȒ IJȠȣ ʌĮȡȩȞIJȠȢ țĮIJĮȜȩȖȠȣ ȣʌȐȡȤȠȣȞ ȤȡȒıȚİȢ principles of surge protection devices. However for more detailed
ʌȜȘȡȠijȠȡȓİȢ ȖȚĮ IJȘȞ İijĮȡȠȖȒ IJȦȞ įȚĮIJȐȟİȦȞ Įʌȩ țȡȠȣıIJȚțȑȢ information the reader should refer to the European and International
ȣʌİȡIJȐıİȚȢ ĮȜȜȐ ȖȚĮ ʌİȡȚııȩIJİȡİȢ ȜİʌIJȠȑȡİȚİȢ Ƞ ĮȞĮȖȞȫıIJȘȢ ʌȠȡİȓ series of standards EN / IEC 62305.
ȞĮ ĮȞĮijİȡșİȓ ıIJĮ ȚıȤȪȠȞIJĮ ʌȡȩIJȣʌĮ ıİȚȡȐȢ Ǽȁȅȉ Ǽȃ 62305 țĮșȫȢ țĮȚ
Ǽȁȅȉ Ǽȃ 61643. ȆĮȡȐȜȜȘȜĮ Ș ǼȁǼȂȀȅ ǹǺǼǼ ȑıĮ Įʌȩ IJȚȢ Additionally ELEMKO SA has issued technical guides fully updated
IJİȤȞȚțȑȢ İțįȩıİȚȢ IJȘȢ, ȠȚ ȠʌȠȓİȢ ȑȤȠȣȞ İʌĮȞĮțȣțȜȠijȠȡȒıİȚ to the new standards, which translate in a simpler manner the standard
țĮȜȪʌIJȠȞIJĮȢ ȩȜİȢ IJȚȢ ȞȑİȢ ĮʌĮȚIJȒıİȚȢ IJȦȞ ȚıȤȣȩȞIJȦȞ ʌȡȠIJȪʌȦȞ, requirements by giving information on how the user can achieve the
İIJĮijȑȡİȚ ĮʌȜȐ țĮȚ țĮIJĮȞȠȘIJȐ IJȠȞ IJȡȩʌȠ ȣȜȠʌȠȓȘıȘȢ IJȦȞ ĮʌĮȚIJȒıİȦȞ, desired result as well as to how select the appropriate product by
įȓȞȠȞIJĮȢ ʌȠȜȣȐȡȚșĮ ʌĮȡĮįİȓȖĮIJĮ İijĮȡȠȖȒȢ, țĮșȠįȘȖȫȞIJĮȢ IJȠ outlining numerous application examples fitting the needs of design
İȜİIJȘIJȒ, İȖțĮIJĮıIJȐIJȘ țĮȚ İʌȚȕȜȑʌȠȞIJĮ İȞȩȢ ȑȡȖȠȣ ıIJȠ ıȦıIJȩ engineers, installers and project supervisors.
ıȤİįȚĮıȩ țĮȚ ıIJȘ ıȦıIJȒ İʌȚȜȠȖȒ IJȦȞ țĮIJȐȜȜȘȜȦȞ ȣȜȚțȫȞ.
4
ÁÐÁÃÙÃÏÉ ÊÑÏÕÓÔÉÊÙÍ ÕÐÅÑÔÁÓÅÙÍ SURGE PROTECTIVE DEVICES A
ǼȚıĮȖȦȖȒ ıIJȘȞ ʌȡȠıIJĮıȓĮ Įʌȩ țȡȠȣıIJȚțȑȢ ȣʌİȡIJȐıİȚȢ Introduction to surge protection
ȅȚ ȣʌİȡIJȐıİȚȢ ĮȞȐȜȠȖĮ İ IJȘȞ ʌȘȖȒ ʌȠȣ IJȚȢ ʌȡȠțĮȜİȓ ʌȠȡȠȪȞ ȞĮ Overvoltages may be generated out of various sources, which will
ȑȤȠȣȞ įȚĮijȠȡİIJȚțȐ ȤĮȡĮțIJȘȡȚıIJȚțȐ țĮȚ ȞĮ ĮʌĮȚIJȠȪȞ įȚĮijȠȡİIJȚțȩ consequently have different characteristics and therefore they may
IJȡȩʌȠ ĮȞIJȚİIJȫʌȚıȘȢ. Ǿ ǼȚțȩȞĮ 1 ʌĮȡȠȣıȚȐȗİȚ IJȚȢ ʌȜȑȠȞ ıȣȞȘșȚıȑ- require different protection measures. Figure 1 describes the most
ȞİȢ ȠȡijȑȢ ȣʌİȡIJȐıİȦȞ. ȈțȠʌȩȢ IJȦȞ ʌİȡȚııȠIJȑȡȦȞ ʌȡȠȧȩȞIJȦȞ ʌȠȣ common overvoltages. The aim of most of the products that are
ʌİȡȚȖȡȐijȠȞIJĮȚ ıIJȠȞ ʌĮȡȩȞ țĮIJȐȜȠȖȠ İȓȞĮȚ ȞĮ ʌİȡȚȠȡȓȗȠȣȞ IJȘȢ included in the present catalogue is to reduce switching and lightning
ȣʌİȡIJȐıİȚȢ Įʌȩ ȤİȚȡȚıȠȪȢ įȚĮțȠʌIJȫȞ țĮȚ IJȚȢ ȣʌİȡIJȐıİȚȢ Įʌȩ overvoltages. The temporary overvoltages are generated by poor
țİȡĮȣȞȠȪȢ. ȅȚ ȣʌİȡIJȐıİȚȢ İȖȐȜȘȢ įȚȐȡțİȚĮȢ (ms…s) ȠijİȓȜȠȞIJĮȚ quality of the power supply and have long duration (ms…s). They are
ıIJȘȞ ʌȠȚȩIJȘIJĮ ʌĮȡȠȤȒȢ IJȠȣ įȚțIJȪȠȣ țĮȚ ĮȞIJȚİIJȦʌȓȗȠȞIJĮȚ İ generally controlled by voltage stabilizers, UPS etc. The switching and
ıIJĮșİȡȠʌȠȚȘIJȑȢ IJȐıİȦȢ, UPS țIJȜ. ȅȚ ȣʌİȡIJȐıİȚȢ Įʌȩ ȤİȚȡȚıȠȪȢ the lightning overvoltages are known as surge overvoltages and they
įȚĮțȠʌIJȫȞ ȩʌȦȢ țĮȚ Įʌȩ țİȡĮȣȞȠȪȢ ȠȞȠȐȗȠȞIJĮȚ țȡȠȣıIJȚțȑȢ are characterised by short duration (s) and high absolute values (kV).
ȣʌİȡIJȐıİȚȢ țĮșȫȢ ȑȤȠȣȞ ȚțȡȒ įȚȐȡțİȚĮ (s) ĮȜȜȐ İȖȐȜȘ ĮʌȩȜȣIJȘ They can be limited by using surge protective devices. Surge
IJȚȒ (kV) țĮȚ ĮȞIJȚİIJȦʌȓȗȠȞIJĮȚ İ IJȠȣȢ ĮʌĮȖȦȖȠȪȢ țȡȠȣıIJȚțȫȞ overvoltages caused by a lightning discharge are the most destructive
ȣʌİȡIJȐıİȦȞ. ȅȚ ʌȜȑȠȞ țĮIJĮıIJȡȠijȚțȑȢ țĮȚ įȪıțȠȜİȢ ıİ ĮȞIJȚİIJȫʌȚıȘ and they are also the most difficult to be controlled.
İȓȞĮȚ ȠȚ ȣʌİȡIJȐıİȚȢ ȠijİȚȜȩİȞİȢ ıİ țİȡĮȣȞȠȪȢ.
Ǿ ʌIJȫıȘ İȞȩȢ țİȡĮȣȞȠȪ ʌȠȡİȓ ȞĮ ʌȡȠțĮȜȑıİȚ ıȠȕĮȡȑȢ ȗȘȚȑȢ ıİ ȚĮ A lightning strike may cause serious damage to an electrical
ȘȜİțIJȡȠȜȠȖȚțȒ İȖțĮIJȐıIJĮıȘ IJȠ ȑȖİșȠȢ IJȦȞ ȠʌȠȓȦȞ ʌȠȡİȓ ȞĮ İȓȞĮȚ installation, which may lead up to a complete destruction of it as it can
ȠȜȠțȜȘȡȦIJȚțȒ țĮIJĮıIJȡȠijȒ ȩʌȦȢ ijĮȓȞİIJĮȚ ıIJȘȞ ǼȚțȩȞĮ 2. be seen in Figure 2.
One of the main factors responsible for the size of the damage is the
ȉȠ ȑȖİșȠȢ IJȘȢ țĮIJĮıIJȡȠijȒȢ İȟĮȡIJȐIJĮȚ ıİ İȖȐȜȠ ȕĮșȩ Įʌȩ IJȠ peak current and the waveshape of the lightning discharge. Lightning
ȑȖȚıIJȠ ȡİȪĮ țĮȚ IJȘȞ ȠȡijȒ IJȠȣ țİȡĮȣȞȠȪ. ȅ țİȡĮȣȞȩȢ İȓȞĮȚ ȚĮ is a natural current source. The flow of the lightning current generates
ijȣıȚțȒ ʌȘȖȒ ȡİȪĮIJȠȢ IJȠȣ ȠʌȠȓȠȣ Ș ȡȠȒ įȘȚȠȣȡȖİȓ İȓIJİ ȦȚțȐ İȓIJİ mainly either by resistive or inductive coupling the surge overvoltages.
İʌĮȖȦȖȚțȐ țĮIJȐ țȪȡȚȠ ȜȩȖȠ IJȚȢ țȡȠȣıIJȚțȑȢ ȣʌİȡIJȐıİȚȢ.
Lightning strokes as a natural phenomenon can not be identical with
ȀĮșȫȢ ȠȚ țİȡĮȣȞȠȓ İȓȞĮȚ ȑȞĮ ijȣıȚțȩ ijĮȚȞȩİȞȠ įİȞ İȓȞĮȚ ȩȠȚȠȚ each other since the energy and the shape of them may be different each
İIJĮȟȪ IJȠȣȢ țĮșȫȢ Ș İȞȑȡȖİȚĮ țĮȚ Ș ȠȡijȒ IJȠȣȢ țȐșİ ijȠȡȐ ʌȠȡİȓ ȞĮ time.
įȚĮijȑȡİȚ.
However after long investigation and field measurements it has been
ȂİIJȐ Įʌȩ ʌȠȜȣİIJȒȢ ȑȡİȣȞİȢ țĮȚ țĮIJĮȖȡĮijȑȢ IJȠȣ ijȣıȚțȠȪ ĮȣIJȠȪ accepted to consider the peak lightning current to have a value of
ijĮȚȞȩİȞȠȣ ȦȢ ȑȖȚıIJȘ IJȚȒ İȞȩȢ țİȡĮȣȞȠȪ șİȦȡȠȪȞIJĮȚ IJĮ 200kA İ 200kA and a waveshape of 10/350s [EN / IEC 62305 - 1, 2006].
țȡȠȣıIJȚțȒ țȣĮIJȠȠȡijȒ 10/350s [Ǽȁȅȉ Ǽȃ 62305 - 1, 2006].
5
A ÁÐÁÃÙÃÏÉ ÊÑÏÕÓÔÉÊÙÍ ÕÐÅÑÔÁÓÅÙÍ SURGE PROTECTIVE DEVICES
īİȚIJȠȞȚțȩȢ țİȡĮȣȞȩȢ
Nearby lightning
ǼȚțȩȞĮ 3: ȀĮIJĮıIJȡȠijȑȢ ıİ ȘȜİțIJȡȚțȐ țĮȚ ȘȜİțIJȡȠȞȚțȐ țȣțȜȫĮIJĮ Įʌȩ ȐİıĮ țĮȚ ȑİıĮ țİȡĮȣȞȚțȐ ʌȜȒȖĮIJĮ
Figure 3: Damage to electrical and electronic circuits due to direct and indirect lightning strikes
6
ÁÐÁÃÙÃÏÉ ÊÑÏÕÓÔÉÊÙÍ ÕÐÅÑÔÁÓÅÙÍ SURGE PROTECTIVE DEVICES A
ȀĮIJĮȞȠȒ țİȡĮȣȞȚțȠȪ ȡİȪĮIJȠȢ Distribution of lightning current
ȉȠ ʌȡȩIJȣʌȠ IEC 61643-12 ĮȞĮijȑȡİȚ İȐȞ ȚĮ țĮIJĮıțİȣȒ įİȤIJİȓ ȑȞĮ According to IEC 61643-12 if a structure receives a direct lightning
ȐİıȠ țİȡĮȣȞȚțȩ (ǿ) ʌȜȒȖĮ IJȠ 50% IJȠȣ ȡİȪĮIJȠȢ șĮ İțijȠȡIJȚıIJİȓ strike (ǿ) 50% of the lightning current will discharge through the local
ıIJȘȞ IJȠʌȚțȒ ȖİȓȦıȘ IJȘȢ țĮIJĮıțİȣȒȢ İȞȫ IJȠ ȣʌȩȜȠȚʌȠ 50% (ǿs) șĮ earthing system where as the remaining 50% (ǿs) will discharge
țĮIJĮȞİȘșİȓ ıIJȚȢ ȣʌȩȜȠȚʌİȢ İȚıİȡȤȩİȞİȢ ĮȖȫȖȚİȢ ʌĮȡȠȤȑȢ ȩʌȦȢ through the other incoming conductive services such as metallic water
İIJĮȜȜȚțȠȓ ıȦȜȒȞİȢ ȪįȡİȣıȘȢ, İIJĮȜȜȚțȠȓ ıȦȜȒȞİȢ ijȣıȚțȠȪ ĮİȡȓȠȣ, and gas pipes, electric power supply etc. The percentage of the current
İȞİȡȖİȚĮțȒ ʌĮȡȠȤȒ ț.IJ.Ȝ. ȉȠ ʌȠıȠıIJȩ IJȠȣ țİȡĮȣȞȚțȠȪ ȡİȪĮIJȠȢ ʌȠȣ that will flow through each incoming conductive service (Ii) can be
șĮ ʌİȡȐıİȚ Įʌȩ IJȘȞ țȐșİ ĮȖȫȖȚȘ ʌĮȡȠȤȒ (Ii) ʌȠȡİȓ ȞĮ İțIJȚȘșİȓ ȦȢ calculated Ii = Is / n, where n is the total number of the incoming
Ii = Is /n, ȩʌȠȣ n İȓȞĮȚ IJȠ ʌȜȒșȠȢ IJȦȞ İȚıİȡȤȩİȞȦȞ ĮȖȫȖȚȦȞ ʌĮȡȠȤȫȞ. conductive services.
īȚĮ ʌĮȡȐįİȚȖĮ İȐȞ ȚĮ țĮIJĮıțİȣȒ įȚĮșȑIJİȚ IJȡİȚȢ (n = 3) İȚıİȡȤȩİȞİȢ As an example if a structure has three (n = 3) conductive incoming
ĮȖȫȖȚİȢ ʌĮȡȠȤȑȢ (ȑȞĮ İIJĮȜȜȚțȩ ıȦȜȒȞĮ ȪįȡİȣıȘȢ, ȑȞĮ İIJĮȜȜȚțȩ services (one metallic water pipe, one metallic gas pipe and one power
ıȦȜȒȞĮ ijȣıȚțȠȪ ĮİȡȓȠȣ țĮȚ ȑȞĮ İȞİȡȖİȚĮțȩ țĮȜȫįȚȠ) IJȩIJİ ıİ cable) then in the event of a direct lightning strike on the structure the
ʌİȡȓʌIJȦıȘ ȐİıȠȣ țİȡĮȣȞȚțȠȪ ʌȜȒȖĮIJȠȢ ıIJȘȞ țĮIJĮıțİȣȒ, IJȠ IJȠʌȚțȩ local earthing system will discharge the 50% of the lightning current
ıȪıIJȘĮ ȖİȓȦıȘȢ șĮ İțijȠȡIJȓıİȚ IJȠ 50% IJȠȣ ȡİȪĮIJȠȢ, İȞȫ Ș țȐșİ and the remaining current will be subdivided to the three conductive
ĮȖȫȖȚȘ ʌĮȡȠȤȒ șĮ İțijȠȡIJȓıİȚ IJȠ 16,6% IJȠȣ țİȡĮȣȞȚțȠȪ ȡİȪĮIJȠȢ, incoming services Ii = Is / 3 => Ii = 16.6% (see Figure 4).
Ii = Is / 3 => Ii = 16.6% (ȕȜ. ǼȚțȩȞĮ 4).
In case that one incoming conductive service has more that one
Ȉİ ʌİȡȓʌIJȦıȘ ʌȠȣ Ș ȚĮ İȚıİȡȤȩİȞȘ ĮȖȫȖȚȘ ʌĮȡȠȤȒ ȑȤİȚ conductive lines (i.e. an incoming 3-phase power cable may have four
ʌİȡȚııȩIJİȡİȢ Įʌȩ ȚĮ ĮȖȫȖȚİȢ ȖȡĮȑȢ (ʌ.Ȥ. ȚĮ İȞİȡȖİȚĮțȒ 3ĭ conductors , L1, L2, L3 and ȃ) than the calculation of the distribution of
ĮȖȫȖȚȘ ʌĮȡȠȤȒ ȑȤİȚ ȑȞĮ țĮȜȫįȚȠ İ 4 ĮȖȦȖȠȪȢ, L1, L2, L3 țĮȚ ȃ) IJȩIJİ the lightning current that will flow through each of the conductive lines
Ƞ ȣʌȠȜȠȖȚıȩȢ IJȠȣ țİȡĮȣȞȚțȠȪ ȡİȪĮIJȠȢ ȖȚĮ țȐșİ ĮȖȦȖȩ (ǿv) (ǿv) is given by the division of the percentage of the lightning current
ʌȡȠțȪʌIJİȚ Įʌȩ IJȘ įȚĮȓȡİıȘ IJȠȣ țİȡĮȣȞȚțȠȪ ȡİȪĮIJȠȢ ʌȠȣ șĮ that will flow through conductive service (Ii) with respect to the
İțijȠȡIJȚıIJİȓ Įʌȩ IJȘȞ ĮȖȫȖȚȘ ʌĮȡȠȤȒ (Ii) ȦȢ ʌȡȠȢ IJȠ ʌȜȒșȠȢ IJȦȞ number of the conductive lines of the cable (m), ǿv = Ii / m.
ĮȖȫȖȚȦȞ ȖȡĮȫȞ (m), ǿv = Ii / m.
For example if a structure has only one incoming conductive power
īȚĮ ʌĮȡȐįİȚȖĮ İȐȞ ȚĮ țĮIJĮıțİȣȒ įȚĮșȑIJİȚ ȚĮ ȩȞȠ İȚıİȡȤȩİȞȘ cable (n = 1), which is composed out of four (m = 4) conductors (L1, L2,
İȞİȡȖİȚĮțȒ ʌĮȡȠȤȒ (n = 1) ʌȠȣ ĮʌȠIJİȜİȓIJĮȚ Įʌȩ ȑȞĮ țĮȜȫįȚȠ İ L3 and N) then in the event of a direct lightning strike on the structure
IJȑııİȡİȚȢ (m = 4) ĮȖȦȖȠȪȢ (L1, L2, L3 țĮȚ ȃ) IJȩIJİ ıİ ʌİȡȓʌIJȦıȘ the local earthing system will discharge the 50% of the lightning
ȐİıȠȣ țİȡĮȣȞȚțȠȪ ʌȜȒȖĮIJȠȢ ıIJȘȞ țĮIJĮıțİȣȒ, IJȠ IJȠʌȚțȩ ıȪıIJȘĮ current and the reaming 50% will flow through the power cable. Then
ȖİȓȦıȘȢ șĮ İțijȠȡIJȓıİȚ IJȠ 50% țĮȚ Ș İȞİȡȖİȚĮțȒ ʌĮȡȠȤȒ IJȠ ȐȜȜȠ 50% each conductor of the power cable will discharge the 12,5% of the total
IJȠȣ ȡİȪĮIJȠȢ, IJȩIJİ Ƞ țȐșİ ĮȖȦȖȩȢ IJȠȣ țĮȜȦįȓȠȣ șĮ İțijȠȡIJȓıİȚ IJȠ lightning current , Ii = Is / 1 (n = 1) => Ii = 50% and ǿv = Ii / 4 (m = 4) =>
12,5% IJȠȣ ȠȜȚțȠȪ țİȡĮȣȞȚțȠȪ ȡİȪĮIJȠȢ, Ii = Is / 1 (n = 1) => Ii = 50% ǿv = 12,5% (see Figure 5).
țĮȚ ǿv = Ii / 4 (m = 4) => ǿv = 12,5% (ȕȜ. ǼȚțȩȞĮ 5)
16,6% IJȠȣ ȡİȪĮIJȠȢ ıIJȠ țȐșİ 16,6% of the current will flow
İIJĮȜȜȚțȩ įȓțIJȣȠ ıȦȜȘȞȫıİȦȞ through each pipe network
50% IJȠȣ ȡİȪĮIJȠȢ ıIJȘ IJȠʌȚțȒ ȖİȓȦıȘ
50% of current to local earthing
ǼȚțȩȞĮ 4: ȀĮIJĮİȡȚıȩȢ țİȡĮȣȞȚțȠȪ ȡİȪĮIJȠȢ ıIJĮ İȚıİȡȤȩİȞĮ ĮȖȫȖȚĮ įȓțIJȣĮ ȚĮȢ țĮIJĮıțİȣȒȢ
Figure 4: Lightning current distribution to the incoming conductive lines of a structure
7
A ÁÐÁÃÙÃÏÉ ÊÑÏÕÓÔÉÊÙÍ ÕÐÅÑÔÁÓÅÙÍ SURGE PROTECTIVE DEVICES
4 X 25kA (10/350 )
L1
L2
Substation earthing N
PE
L L L PE
200kA (10/350 s) 100kA (10/350 s) SPD SPD SPD SPD
UC = 275Vac UC = 275Vac U C = 275Vac UC = 255Vac
Up = <1,9kV Up = <1,9kV U p = <1,9kV Up = <4kV
I imp= 25kA (10/350 s) Iimp = 25kA (10/350 s) I imp = 25kA (10/350 s) Iimp = 100kA (10/350 s)
I max= 200kA (8/20 s) Imax = 200kA (8/20 s) I max= 200kA (8/20 s) Imax = 200kA (8/20 s)
T a = <25ns Ta = <25ns T a = <25ns T a = <100ns
68 50 200 T1 + T2 CE 68 50 200 T1 + T2 CE 68 50 200 T1 + T2 CE 68 51 200 T1 + T2 CE
N N N N
ȉȠʌȚțȒ ȖİȓȦıȘ
Local earthing
ǼȚțȩȞĮ 5: ȀĮIJĮİȡȚıȩȢ țİȡĮȣȞȚțȠȪ ȡİȪĮIJȠȢ ıIJȠȣȢ ĮȖȦȖȠȪȢ IJȠȣ İȞİȡȖİȚĮțȠȪ įȚțIJȪȠȣ, IJȠ ȑȖȚıIJȠ țİȡĮȣȞȚțȩ ȡİȪĮ ıȪijȦȞĮ İ IJȠ Ǽȁȅȉ Ǽȃ 62305-1 șİȦȡȠȪȞIJĮȚ
IJĮ 200kA (10/350s)
Figure 5: Lightning current distribution to the electric power conductors, maximum lightning current as per EN 62305-1 is considered 200kA (10/350s)
ǼıȦIJİȡȚțȩ ȈȪıIJȘĮ ǹȞIJȚțİȡĮȣȞȚțȒȢ ȆȡȠıIJĮıȓĮȢ ȈǹȆ Internal Lightning Protection System LPS
ȈțȠʌȩȢ IJȠȣ İıȦIJİȡȚțȠȪ ȈǹȆ İȓȞĮȚ ȞĮ ʌȡȠıIJĮIJİȪıİȚ ĮȞșȡȫʌȠȣȢ țĮȚ The aim of the internal LPS is to protect human life and electrical /
ȘȜİțIJȡȚțȑȢ / ȘȜİțIJȡȠȞȚțȑȢ įȚĮIJȐȟİȚȢ Įʌȩ țȡȠȣıIJȚțȑȢ ȣʌİȡIJȐıİȚȢ ȠȚ electronic installations against surge overvoltages, which are caused
ȠʌȠȓİȢ ȠijİȓȜȠȞIJĮȚ İȓIJİ ıİ ȐİıȠ țİȡĮȣȞȚțȩ ʌȜȒȖĮ İȓIJİ ıİ ȑİıȠ either by direct or indirect lightning strike. As described in the
ʌȜȒȖĮ. ǵʌȦȢ ʌȡȠȕȜȑʌİȚ IJȠ ʌȡȩIJȣʌȠ Ǽȁȅȉ Ǽȃ 62305 - 4, Ƞ ȩȖțȠȢ IJȘȢ European and International standard EN / IEC 62305 - 4 the volume of
țĮIJĮıțİȣȒȢ ʌȠȣ ʌȡȩțİȚIJĮȚ ȞĮ ʌȡȠıIJĮIJİȣșİȓ ȤȦȡȓȗİIJĮȚ ıİ ȗȫȞİȢ the structure that is to be protected against lightning shall be divided
(Lightning Protection Zones LPZ), ıİ ıȣȞȐȡIJȘıȘ țȣȡȓȦȢ IJȘȢ ȑȞIJĮıȘȢ into zones (Lightning Protection Zones LPZ) with respect to reduction
IJȦȞ țİȡĮȣȞȚțȫȞ İʌȚįȡȐıİȦȞ ıIJȠ ȤȫȡȠ țĮȚ țĮIJȐ įİȪIJİȡȠ, IJȘȢ of the electromagnetic effect of the lightning current and on the
įȚȘȜİțIJȡȚțȒȢ ĮȞIJȠȤȒȢ IJȦȞ ȣʌȩ ʌȡȠıIJĮıȓĮ ȘȜİțIJȡȚțȫȞ ıȣıțİȣȫȞ. ȅȚ dielectric strength of the under protection equipment. The basic LPZ
ȕĮıȚțȑȢ LPZ İȓȞĮȚ ȠȚ ĮțȩȜȠȣșİȢ: are the following:
x LPZ 0A: ȈIJȘ ȗȫȞȘ ĮȣIJȒ ĮȞIJȚțİȓİȞĮ ȣʌȩțİȚȞIJĮȚ ıİ ȐİıĮ x LPZ 0A: Equipment installed in this zone will be subjected to full
țİȡĮȣȞȚțȐ ʌȜȒȖĮIJĮ țĮȚ İȓȞĮȚ İțIJİșİȚȑȞĮ ıİ țȡȠȣıIJȚțȑȢ ȣʌİȡIJȐıİȚȢ direct lightning current and electromagnetic effects without any
țĮȚ ȘȜİțIJȡȠĮȖȞȘIJȚțȑȢ İʌȚįȡȐıİȚȢ ȤȦȡȓȢ ĮʌȩıȕİıȘ. reduction measure.
x LPZ 0B: ȈIJȘ ȗȫȞȘ ĮȣIJȒ ĮȞIJȚțİȓİȞĮ įİȞ įȑȤȠȞIJĮȚ ȐİıĮ x LPZ 0B: Equipment installed in this zone will not be subjected to
țİȡĮȣȞȚțȩ ʌȜȒȖĮ İȞȫ İȓȞĮȚ İțIJİșİȚȑȞĮ ıİ țȡȠȣıIJȚțȑȢ ȣʌİȡIJȐıİȚȢ direct lightning current but they will be subjected to full
țĮȚ ȘȜİțIJȡȠĮȖȞȘIJȚțȑȢ İʌȚįȡȐıİȚȢ ȤȦȡȓȢ țĮȚȐ ĮʌȩıȕİıȘ. electromagnetic effects without any reduction measure.
x LPZ 1: ǹȞIJȚțİȓİȞĮ ıIJȘ ȗȫȞȘ ĮȣIJȒ ȣʌȩțİȚȞIJĮȚ ıİ ȚıȤȣȡȑȢ x LPZ 1: Equipment installed in this zone will be subjected to
ȘȜİțIJȡȠĮȖȞȘIJȚțȑȢ İʌȚįȡȐıİȚȢ İȚȦȑȞȘȢ ȑȞIJĮıȘȢ Įʌȩ IJȚȢ partial lightning current and high electromagnetic effects at a reduced
ʌȡȠȘȖȠȪİȞİȢ ȗȫȞİȢ. level than upstream zones.
x LPZ 2…Ȟ: ǹȞIJȚțİȓİȞĮ ıIJȘ ȗȫȞȘ ĮȣIJȒ ȣʌȩțİȚȞIJĮȚ ıİ x LPZ 2…n: Equipment in this zone will be subjected to surge
İȟĮıșİȞȚıȑȞİȢ ȘȜİțIJȡȠĮȖȞȘIJȚțȑȢ İʌȚįȡȐıİȚȢ, ĮȞȐȜȠȖĮ İ IJĮ ȑIJȡĮ currents and low electromagnetic effects depending on the protection
ʌȡȠıIJĮıȓĮȢ ʌȠȣ ȑȤȠȣȞ ʌȡȠȕȜİijșİȓ ıIJȘȞ ʌȡȠȘȖȠȪİȞȘ ȗȫȞȘ. measures that have been taken in upstream zones.
ȂȑıĮ ıİ țȐșİ ȗȫȞȘ ȩȜİȢ ȠȚ ıȣıțİȣȑȢ ʌȡȑʌİȚ ȞĮ ȑȤȠȣȞ IJȠ ȓįȚȠ All equipments that are installed in the same zone should be at the same
įȣȞĮȚțȩ. ǹȣIJȩ ʌȠȡİȓ ȞĮ ʌȡĮȖĮIJȠʌȠȚȘșİȓ İijĮȡȩȗȠȞIJĮȢ ȚıȠįȣ- potential. This can be succeeded by applying equipotential bonding to
ȞĮȚțȑȢ ıȣȞįȑıİȚȢ ıİ ȩȜĮ IJĮ ĮȖȫȖȚĮ ȑȡȘ, ıȣʌİȡȚȜĮȕĮȞȠȑȞȠȣ all conductive parts including the reinforcement of the structure, where
țĮȚ IJȠȣ ȠʌȜȚıȠȪ IJȘȢ țĮIJĮıțİȣȒȢ İȐȞ ĮȣIJȩ İȓȞĮȚ İijȚțIJȩ, ıȣȞįȑȠȞIJĮȢ this is possible to be achieved, with respect to earth either by a direct
IJĮ İ IJȘȞ ȖİȓȦıȘ IJȘȢ țĮIJĮıțİȣȒȢ İȓIJİ ȐİıĮ İȓIJİ ȑıȦ ĮʌĮȖȦȖȫȞ. bonding or through a surge protective device.
8
ÁÐÁÃÙÃÏÉ ÊÑÏÕÓÔÉÊÙÍ ÕÐÅÑÔÁÓÅÙÍ SURGE PROTECTIVE DEVICES A
ǽȫȞȘ 0ǹ
ǼțIJİșİȚȑȞĮ ıİ ȐİıȠ țİȡĮȣȞȚțȩ ʌȜȒȖĮ,
10/350s
Zone 0ǹ
Subjected to direct lightning strike
10/350s
ǽȫȞȘ 0Ǻ
ǽȫȞȘ 1 ǽȫȞȘ 2, ǽȫȞȘ 3
ȀİȡĮȣȞȚțȐ ȡİȪĮIJĮ, 10/350s ȀȡȠȣıIJȚțȐ ȡİȪĮIJĮ, 8/20s Zone 0Ǻ
Zone 2, Zone 3
Zone 1
Lightning currents, 10/350s Surge currents, 8/20s
ǽȫȞȘ 0Ǻ
ȆȡȠıIJĮIJİȪȠȞIJĮȚ Įʌȩ ȐİıȠ
țİȡĮȣȞȚțȩ ʌȜȒȖĮ
Zone 0Ǻ
Protected from direct
lightning strike
MAX MIN
DzȞIJĮıȘ ȘȜİțIJȡȠĮȖȞȘIJȚțȠȪ ʌİįȓȠȣ ıIJȠ İıȦIJİȡȚțȩ IJȘȢ țĮIJĮıțİȣȒȢ
Immunity of equipment to the electromagnetic field inside the structure due to lightning
9
A ÁÐÁÃÙÃÏÉ ÊÑÏÕÓÔÉÊÙÍ ÕÐÅÑÔÁÓÅÙÍ SURGE PROTECTIVE DEVICES
ȀĮIJȘȖȠȡȓĮ IV
Category IV
6kV
ȀĮIJȘȖȠȡȓĮ III
Category III
4kV
ȀĮIJȘȖȠȡȓĮ II
Category II
2,5kV
ȀĮIJȘȖȠȡȓĮ I
Category I
1,5kV
ǼȚțȩȞĮ 7: ȀĮIJȘȖȠȡȓİȢ įȚȘȜİțIJȡȚțȒȢ ĮȞIJȠȤȒȢ ıȣıțİȣȫȞ İȖțĮIJİıIJȘȑȞİȢ ıİ įȓțIJȣȠ 230/400V AC ıȪijȦȞĮ İ IJȠ ʌȡȩIJȣʌȠ IEC 60364 - 4 - 44
Figure 7: Overvoltage categories of electrical equipment installed in a 230/400V AC system according to IEC 60364 - 4 - 44
80kV
6kV 2,5kV 1,5kV
CAT III
CAT I
MV
CAT IV CAT II
L L L PE L L L N
PE
N N N N
10
ÁÐÁÃÙÃÏÉ ÊÑÏÕÓÔÉÊÙÍ ÕÐÅÑÔÁÓÅÙÍ SURGE PROTECTIVE DEVICES A
ȀĮIJȘȖȠȡȓİȢ İȞİȡȖİȚĮțȫȞ ĮʌĮȖȦȖȫȞ Categories of power surge protective devices
ȈȪijȦȞĮ İ IJȠ ʌȡȩIJȣʌȠ Ǽȁȅȉ Ǽȃ 61643 - 11 ȠȚ ĮʌĮȖȦȖȠȓ According to the standard EN 61643 - 11 the surge protective devices
İȞİȡȖİȚĮțȫȞ įȚțIJȪȦȞ ȤĮȘȜȒȢ IJȐıİȦȢ ȤȦȡȓȗȠȞIJĮȚ ıİ IJȡİȚȢ which are connected to a low voltage system are separated into three
țĮIJȘȖȠȡȓİȢ. categories.
1Ș Type 1 (T1) - Class I, ʌȡȦIJİȪȠȣıĮ ʌȡȠıIJĮıȓĮ Įʌȩ țİȡĮȣȞȚțȩ 1st Type 1 (T1) - Class I, primary protection against lightning current,
ȡİȪĮ, Iimp (10/350s) Iimp (10/350s)
2 ȉype 2 (T2) - Class II, secondary protection against surge current,
nd
2Ș ȉype 2 (T2) - Class II, įİȣIJİȡİȪȠȣıĮ ʌȡȠıIJĮıȓĮ Įʌȩ țȡȠȣıIJȚțȩ
ȡİȪĮ, Imax (8/20s) Imax (8/20s)
3 ȉype 3 (T3) - Class IǿI, fine protection against surge currents, Isc
Ș rd
3 ȉype 3 (T3) - Class IǿI, ȜİʌIJȒ ʌȡȠıIJĮıȓĮ Įʌȩ țȡȠȣıIJȚțȩ ȡİȪĮ, Isc
(8/20s) țĮȚ țȡȠȣıIJȚțȑȢ ȣʌİȡIJȐıİȚȢ, Uoc (1.2/50s) (8/20s) and surge overvoltages, Uoc (1.2/50s)
ȅȚ ĮʌĮȖȦȖȠȓ ȉ1 İȖțĮșȓıIJĮȞIJĮȚ ıȣȞȒșȦȢ ıIJȘȞ İȓıȠįȠ IJȘȢ T1 surge protective devices are mainly installed at the entry point of
İȖțĮIJȐıIJĮıȘȢ (ʌ.Ȥ. ȖİȞȚțȩȢ ʌȓȞĮțĮȢ ʌĮȡȠȤȒȢ) ıIJĮ ȩȡȚĮ IJȦȞ ȗȦȞȫȞ the electrical installation into a structure (i.e. main switchboard) at the
LPZ 0ǹ - LPZ 1 Ȓ LPZ 0Ǻ - LPZ 1, ʌȡȠıijȑȡȠȞIJĮȢ ʌȡȠıIJĮıȓĮ Įʌȩ borders between LPZ 0ǹ - LPZ 1 or LPZ 0Ǻ - LPZ 1 providing
țİȡĮȣȞȚțȐ ȡİȪĮIJĮ (10/350s) țĮȚ ȑȤȠȞIJĮȢ ıIJȐșȘ ʌȡȠıIJĮıȓĮȢ (Up) protection against lightning currents (10/350s) having a voltage
ȚțȡȩIJİȡȘ Įʌȩ 4kV ʌĮȡȑȤȠȞIJĮȢ ʌȡȠıIJĮıȓĮ ıİ ıȣıțİȣȑȢ țĮIJȘȖȠȡȓĮȢ protection level (Up) lower than 4kV protecting equipment of
III țĮȚ IV (ȕȜ. ǼȚțȩȞĮ 8). overvoltage category III and IV (see Figure 8).
ȅȚ ĮʌĮȖȦȖȠȓ ȉ2 İȖțĮșȓıIJĮȞIJĮȚ ıȣȞȒșȦȢ ıİ įȚȐijȠȡĮ țȠȕȚțȐ ıȘİȓĮ T2 surge protective devices are installed at main node points of the
IJȘȢ İȖțĮIJȐıIJĮıȘȢ (ʌ.Ȥ. ȣʌȠʌȓȞĮțİȢ) ıIJĮ ȩȡȚĮ IJȦȞ ȗȦȞȫȞ LPZ 1 - LPZ 2, electrical installation (i.e. secondary switchboards) at the borders
ʌȡȠıijȑȡȠȞIJĮȢ ʌȡȠıIJĮıȓĮ Įʌȩ țȡȠȣıIJȚțȐ ȡİȪĮIJĮ (8/20s) țĮȚ ȑȤȠȞIJĮȢ between LPZ 1 - LPZ 2, providing protection against surge currents
ıIJȐșȘ ʌȡȠıIJĮıȓĮȢ (Up) ȚțȡȩIJİȡȘ Įʌȩ 2,5kV ʌĮȡȑȤȠȞIJĮȢ ʌȡȠıIJĮıȓĮ (8/20s) having a voltage protection (Up) level lower than 2,5kV
ıİ ıȣıțİȣȑȢ țĮIJȘȖȠȡȓĮȢ II ( ȕȜ. ǼȚțȩȞĮ 8). protecting equipment of overvoltage category II (see Figure 8).
ȅȚ ĮʌĮȖȦȖȠȓ ȉ3 İȖțĮșȓıIJĮȞIJĮȚ ĮȞİȟĮȡIJȒIJȠȣ ȗȫȞȘȢ ĮțȡȚȕȫȢ ʌȡȚȞ Įʌȩ T3 surge protective devices are installed independently of the zone
IJȘȞ İȓıȠįȠ ȚĮȢ İȣĮȓıșȘIJȘȢ ıȣıțİȣȒȢ ʌȠȣ ʌİȡȚȑȤİȚ ȘȜİțIJȡȠȞȚțȐ boundaries. Their installation point is as near as possible to the under
țȣțȜȫĮIJĮ (ʌ.Ȥ. ȘȜİțIJȡȠȞȚțȠȓ ȣʌȠȜȠȖȚıIJȑȢ, PLC țIJȜ), ʌȡȠıijȑȡȠȞIJĮȢ protection equipment which contains electronic circuits (i.e. PC, PLC,
ȜİʌIJȒ ʌȡȠıIJĮıȓĮ Įʌȩ țȡȠȣıIJȚțȐ ȡİȪĮIJĮ (8/20s) țĮȚ ȑȤȠȞIJĮȢ etc) providing fine protection against both surge currents (8/20s) and
ıIJȐșȘ ʌȡȠıIJĮıȓĮȢ (Up) ȚțȡȩIJİȡȘ Įʌȩ 1,5kV ʌĮȡȑȤȠȞIJĮȢ ʌȡȠıIJĮıȓĮ surge voltages having a voltage protection level (Up) lower than 1,5kV
ıİ ıȣıțİȣȑȢ țĮIJȘȖȠȡȓĮȢ I. ǹʌĮȡĮȓIJȘIJȘ ʌȡȠȨʌȩșİıȘ ȖȚĮ IJȘ ıȦıIJȒ protecting equipment of overvoltage category I. T3 surge protective
ȜİȚIJȠȣȡȖȓĮ IJȦȞ ĮʌĮȖȦȖȫȞ ȉ3 İȓȞĮȚ ȞĮ ʌȡȠȘȖȠȪȞIJĮȚ ĮʌĮȖȦȖȠȓ ȉ2 devices should always be installed at least after at least T2 surge
IJȠȣȜȐȤȚıIJȠȞ (ȕȜ. ǼȚțȩȞĮ 8). protector (see Figure 8).
Ǿ ȕĮıȚțȒ įȚĮijȠȡȐ İIJĮȟȪ ĮʌĮȖȦȖȫȞ ȉ1, ȉ2 țĮȚ ȉ3 İȓȞĮȚ ȩIJȚ ȠȚ ȉ1 The basic difference between the T1, T2 and T3 SPDs is that T1 SPDs
ȑȤȠȣȞ IJȘȞ ȚțĮȞȩIJȘIJĮ İțijȩȡIJȚıȘȢ țİȡĮȣȞȚțȫȞ ȡİȣȐIJȦȞ țȣĮIJȠ- are capable to discharge lightning currents of a waveshape 10/350s
ȠȡijȒȢ 10/350s İȞȫ ȠȚ ȉ2 țĮȚ ȉ3 İțijȠȡIJȓȗȠȣȞ ȩȞȠ țȡȠȣıIJȚțȐ instead T2 and T3 are only able to discharge surge currents of a
ȡİȪĮIJĮ țȣĮIJȠȠȡijȒȢ 8/20s. H įȚĮijȠȡȐ IJȦȞ įȪȠ țȣĮIJȠȠȡijȫȞ waveshape of 8/20s. The main difference between the two
ijĮȓȞİIJĮȚ ıIJȘȞ ǼȚțȩȞĮ 9 țĮȚ İȓȞĮȚ ıIJȠ ijȠȡIJȓȠ țĮȚ ıIJȘȞ İȞȑȡȖİȚĮ. waveshapes is illustrated in Figure 9.
90 T1
25kA (10/350s)
80
16 ijȠȡȑȢ ʌȚȠ ȚıȤȣȡȩ
ȇİȪĮ / Current (kA)
60
10/350s
50
T2
40kA (8/20s)
40
30
20
8/20s
10
0
0 250s 500s 750s 1000s 1250s 1500s
ȋȡȩȞȠȢ / Time (s)
ǼȚțȩȞĮ 9: ¨ȚĮijȠȡȑȢ țȣĮIJȠȠȡijȫȞ țİȡĮȣȞȚțȫȞ ȡİȣȐIJȦȞ 10/350s țĮȚ țȡȠȣıIJȚțȫȞ ȡİȣȐIJȦȞ 8/20s
Figure 9: Differences between lightning current waveshape 10/350s and surge current waveshape 8/20s
11
A ÁÐÁÃÙÃÏÉ ÊÑÏÕÓÔÉÊÙÍ ÕÐÅÑÔÁÓÅÙÍ SURGE PROTECTIVE DEVICES
ǼʌȚȜȠȖȒ İȞİȡȖİȚĮțȫȞ ĮʌĮȖȦȖȫȞ țȡȠȣıIJȚțȫȞ ȣʌİȡIJȐıİȦȞ Selection of power surge protective devices
Ǿ İʌȚȜȠȖȒ țĮȚ Ș ĮȞĮȖțĮȚȩIJȘIJĮ İȖțĮIJȐıIJĮıȘȢ ĮʌĮȖȦȖȫȞ țȡȠȣıIJȚțȫȞ The selection and the necessity of installing surge protective devices
ȣʌİȡIJȐıİȦȞ ʌȡȠțȪʌIJİȚ Įʌȩ IJȘȞ İțIJȓȘıȘ țĮȚ IJȘȞ įȚĮȤİȓȡȚıȘ IJȠȣ arrives after performing the risk management according to the
țȚȞįȪȞȠȣ ȩʌȦȢ ʌİȡȚȖȡȐijİȚ IJȠ ʌȡȩIJȣʌȠ Ǽȁȅȉ Ǽȃ 62305 - 2, 2010. standard EN / IEC 62305 - 2, 2010. Due to the careful and detailed
ȁȩȖȦ IJȘȢ ȚįȚĮȓIJİȡȘȢ ĮȞȐȜȣıȘȢ ʌȠȣ ĮʌĮȚIJİȓIJĮȚ ıIJȘ ıȣȞȑȤİȚĮ įȓȞİIJĮȚ study that it is required the following examples just give an indication
ȩȞȠ ȚĮ İȞįİȚțIJȚțȒ İșȠįȠȜȠȖȓĮ İțIJȓȘıȘȢ IJȦȞ ĮʌĮȡĮȓIJȘIJȦȞ of the necessary surge protective devices as well as their installation
ĮʌĮȖȦȖȫȞ țĮșȫȢ İʌȓıȘȢ țĮȚ IJȠȣ ıȘİȓȠȣ İȖțĮIJȐıIJĮıȒȢ IJȠȣȢ. point.
ȆİȡȓʌIJȦıȘ ǹ: ȀĮIJĮıțİȣȒ ʌȠȣ įȚĮșȑIJİȚ ıȪıIJȘĮ İȟȦIJİȡȚțȒȢ Case A: Structure having an external lightning protection system
ĮȞIJȚțİȡĮȣȞȚțȒȢȠȞʌȡȠıIJĮıȓĮȢ. installed.
ǹʌĮȚIJȠȪȞIJĮȚ: 1 İȖțĮIJȐıIJĮıȘ ĮʌĮȖȦȖȫȞ ȉ1 ıIJȠ ȖİȞȚțȩ ʌȓȞĮțĮ, 2ȠȞ İȖțĮ- Requires: 1st installation of T1 SPDs at the main distribution board, 2nd
IJȐıIJĮıȘ ĮʌĮȖȦȖȫȞ ȉ2 ıİ ȣʌȠʌȓȞĮțİȢ țĮȚ 3ȠȞ İȖțĮIJȐıIJĮıȘ ĮʌĮȖȦȖȫȞ installation of T2 SPDs at secondary distribution boards and 3rd
ȉ3 ʌȡȚȞ IJȘȞ İȓıȠįȠ ȘȜİțIJȡȠȞȚțȫȞ ıȣıțİȣȫȞ (ȕȜ. ǼȚțȩȞĮ 10ǹ). installation of ȉ3 SPDs at the entrance of equipment containing
electronic circuits (see Figure 10A).
ȆİȡȓʌIJȦıȘ Ǻ: ȀĮIJĮıțİȣȒ Ș ȠʌȠȓĮ įİȞ ȑȤİȚ ıȪıIJȘĮ İȟȦIJİȡȚțȒȢ
ĮȞIJȚțİȡĮȣȞȚțȒȢ ʌȡȠıIJĮıȓĮȢ ĮȜȜȐ įȚĮșȑIJİȚ İȚıİȡȤȩİȞĮ ĮȖȫȖȚĮ Case B: Structure not having an external lightning protection system
įȓțIJȣĮ (ʌ.Ȥ. İȞĮȑȡȚĮ ʌĮȡȠȤȒ ¨ǼǾ Ȓ ȅȉǼ) İțIJİșİȚȑȞĮ ıİ ȐİıȠ installed but having incoming conductive services (i.e. overhead
țİȡĮȣȞȚțȩ ʌȜȒȖĮ. ǹʌĮȚIJȠȪȞIJĮȚ: 1ȠȞ İȖțĮIJȐıIJĮıȘ ĮʌĮȖȦȖȫȞ ȉ1 ıIJȠ electric or telecom lines) exposed to direct lightning strike .
ȖİȞȚțȩ ʌȓȞĮțĮ, 2ȠȞ İȖțĮIJȐıIJĮıȘ ĮʌĮȖȦȖȫȞ ȉ2 ıİ ȣʌȠʌȓȞĮțİȢ țĮȚ 3ȠȞ Requires: 1st installation of T1 SPDs at the main distribution board, 2nd
İȖțĮIJȐıIJĮıȘ ĮʌĮȖȦȖȫȞ ȉ3 ʌȡȚȞ IJȘȞ İȓıȠįȠ ȘȜİțIJȡȠȞȚțȫȞ ıȣıțİȣȫȞ installation of T2 SPDs at secondary distribution boards and 3rd
(ȕȜ. ǼȚțȩȞĮ 10Ǻ). installation of ȉ3 SPDs at the entrance of equipment containing
electronic circuits (see Figure 10B).
ȆİȡȓʌIJȦıȘ ī: ȀĮIJĮıțİȣȒ Ș ȠʌȠȓĮ įİȞ ȑȤİȚ ȠȪIJİ ıȪıIJȘĮ İȟȦIJİȡȚțȒȢ
ĮȞIJȚțİȡĮȣȞȚțȒȢ ʌȡȠıIJĮıȓĮȢ ĮȜȜȐ ȠȪIJİ įȚĮșȑIJİȚ İȚıİȡȤȩİȞĮ ĮȖȫȖȚĮ Case C: Structure neither having an external lightning protection
įȓțIJȣĮ İțIJİșİȚȑȞĮ ıİ ȐİıȠ țİȡĮȣȞȚțȩ ʌȜȒȖĮ. ǹʌĮȚIJȠȪȞIJĮȚ: 1ȠȞ system installed or incoming conductive services (i.e. overhead
İȖțĮIJȐıIJĮıȘ ĮʌĮȖȦȖȫȞ ȉ2 ıIJȠ ȖİȞȚțȩ ʌȓȞĮțĮ țĮȚ 2ȠȞ İȖțĮIJȐıIJĮıȘ electric or telecom lines) exposed to direct lightning strike.
ĮʌĮȖȦȖȫȞ ȉ3 ʌȡȚȞ IJȘȞ İȓıȠįȠ ȘȜİțIJȡȠȞȚțȫȞ ıȣıțİȣȫȞ (ȕȜ. Requires: 1st installation of T2 SPDs at the main distribution board, 2nd
ǼȚțȩȞĮ10C). installation of ȉ3 SPDs at the entrance of equipment containing
electronic circuits (see Figure10C).
Ȉİ ȩȜİȢ IJȚȢ ĮȞȦIJȑȡȦ ʌİȡȚʌIJȫıİȚȢ ʌȡȑʌİȚ ȞĮ İțIJȚȘșİȓ Ƞ ĮʌĮȡĮȓIJȘIJȠȢ
ıȣȞIJȠȞȚıȩȢ İIJĮȟȪ IJȦȞ ĮʌĮȖȦȖȫȞ. In all the above case studies co-ordination between the surge protective
devices should be considered.
ȉ1 ȉ2 ȉ3
ȉ3
ȉ3
ǼȚțȩȞĮ 10: ǼʌȚȜȠȖȒ țĮȚ ıȘİȓĮ İȖțĮIJȐıIJĮıȘȢ İȞİȡȖİȚĮțȫȞ ĮʌĮȖȦȖȫȞ țȡȠȣıIJȚțȫȞ ȣʌİȡIJȐıİȦȞ
Figure 10: Selection and installation of power surge protective devices
12
ÁÐÁÃÙÃÏÉ ÊÑÏÕÓÔÉÊÙÍ ÕÐÅÑÔÁÓÅÙÍ SURGE PROTECTIVE DEVICES A
ȈȘİȓĮ İȖțĮIJȐıIJĮıȘȢ İȞİȡȖİȚĮțȫȞ ĮʌĮȖȦȖȫȞ Installation points of power surge protective devices
țȡȠȣıIJȚțȫȞ ȣʌİȡIJȐıİȦȞ
The installation of surge protective devices depends on the electrical
ȉĮ ıȘİȓĮ İȖțĮIJȐıIJĮıȘȢ IJȦȞ ĮʌĮȖȦȖȫȞ țȡȠȣıIJȚțȫȞ ȣʌİȡIJȐıİȦȞ İȟ- installation of the structure as well as on the under protection
ĮȡIJȫȞIJĮȚ Įʌȩ IJȘȞ ȘȜİțIJȡȠȜȠȖȚțȒ İȖțĮIJȐıIJĮıȘ IJȘȢ ȣʌȩ ʌȡȠıIJĮıȓĮ equipment. Due to the careful and detailed study that it is required the
țĮIJĮıțİȣȒȢ țĮșȫȢ țĮȚ Įʌȩ IJȚȢ ȣʌȩ ʌȡȠıIJĮıȓĮ ıȣıțİȣȑȢ IJȘȢ țĮIJĮ- following examples just give an indication of the necessary surge
ıțİȣȒȢ. ȁȩȖȦ IJȘȢ ȚįȚĮȓIJİȡȘȢ ĮȞȐȜȣıȘȢ ʌȠȣ ĮʌĮȚIJİȓIJĮȚ ıIJȘ ıȣȞȑȤİȚĮ protective devices as well as their installation point.
įȓȞİIJĮȚ ȩȞȠ ȚĮ İȞįİȚțIJȚțȒ İșȠįȠȜȠȖȓĮ İțIJȓȘıȘȢ IJȦȞ ĮʌĮȡĮȓIJȘIJȦȞ
ĮʌĮȖȦȖȫȞ țĮșȫȢ İʌȓıȘȢ țĮȚ IJȠȣ ıȘİȓȠȣ İȖțĮIJȐıIJĮıȒȢ IJȠȣȢ. Case A: A structure that contains an electrical installation, which the
total cabling length does not exceed 10m. Then by installing all the
ȆİȡȓʌIJȦıȘ ǹ: Ǿ țĮIJĮıțİȣȒ įȚĮșȑIJİȚ ȚĮ ȘȜİțIJȡȠȜȠȖȚțȒ İȖțĮIJȐ- three types of SPDs, T1 + T2 + T3 in the main distribution panel
ıIJĮıȘ Ș ȠʌȠȓĮ ıȣȞȠȜȚțȐ IJȠ ȑȖȚıIJȠ ȒțȠȢ IJȘȢ țĮȜȦįȓȦıȘȢ įİȞ ȟİ- considering an appropriate co-ordination between them, then no
ʌİȡȞȐ IJĮ 10m. ȉȩIJİ İȖțĮșȚıIJȫȞIJĮȢ ıIJȠ ȖİȞȚțȩ ʌȓȞĮțĮ țĮȚ IJȠȣȢ IJȡİȚȢ additional protection is needed.
IJȪʌȠȣȢ ĮʌĮȖȦȖȫȞ ȉ1 + ȉ2 + ȉ3 İ IJȘȞ ʌȡȠȨʌȩșİıȘ ȩIJȚ İȓȞĮȚ ıȦıIJȐ Case B: A structure that contains an electrical installation, which the
ıȣȞIJȠȞȚıȑȞȠȚ įİȞ ĮʌĮȚIJİȓIJĮȚ İʌȚʌȡȩıșİIJȘ ʌȡȠıIJĮıȓĮ. total cabling length does not exceed 20m. Then by installing T1 + T2
ȆİȡȓʌIJȦıȘ Ǻ: Ǿ țĮIJĮıțİȣȒ įȚĮșȑIJİȚ ȚĮ ȘȜİțIJȡȠȜȠȖȚțȒ İȖțĮIJȐ- SPDs in the main distribution panel and additional T3 SPDs in the
ıIJĮıȘ Ș ȠʌȠȓĮ ıȣȞȠȜȚțȐ IJȠ ȑȖȚıIJȠ ȒțȠȢ IJȘȢ țĮȜȦįȓȦıȘȢ įİȞ ȟİ- secondary distribution panel assuming that the cabling distances
ʌİȡȞȐ IJĮ 20m. ȉȩIJİ İȖțĮșȚıIJȫȞIJĮȢ ıIJȠ ȖİȞȚțȩ ʌȓȞĮțĮ ĮʌĮȖȦȖȩ ȉ1 + between the secondary panel and the electronic equipment does not
ȉ2 țĮȚ ıIJȠȞ ȣʌȠʌȓȞĮțĮ ȉ3 İ IJȘȞ ʌȡȠȨʌȩșİıȘ ȩIJȚ ȠȚ țĮȜȦįȚĮțȑȢ ĮʌȠ- exceed 10m in length then no additional protection is needed.
ıIJȐıİȚȢ Įʌȩ IJȠȞ ȣʌȠʌȓȞĮțĮ ȑȦȢ IJȚȢ ȘȜİțIJȡȠȞȚțȑȢ ıȣıțİȣȑȢ įİȞ ȟİʌİȡ- Case C: A structure that contains an electrical installation, which the
ȞȠȪȞ IJĮ 10m (H/Y & ʌȓȞĮțĮȢ ĮȣIJȠĮIJȚıȠȪ Ǿ/ǽ) įİȞ ĮʌĮȚIJİȓIJĮȚ İʌȚ- total cabling length does exceed 20m assuming that the cabling
ʌȡȩıșİIJȘ ʌȡȠıIJĮıȓĮ. distances between the secondary panel and the electronic equipment
ȆİȡȓʌIJȦıȘ ī: Ǿ țĮIJĮıțİȣȒ įȚĮșȑIJİȚ ȚĮ ȘȜİțIJȡȠȜȠȖȚțȒ İȖțĮIJȐ- does not exceed 10m in length then by installing T1 + T2 SPDs in the
ıIJĮıȘ Ș ȠʌȠȓĮ ıȣȞȠȜȚțȐ IJȠ ȑȖȚıIJȠ ȒțȠȢ IJȘȢ țĮȜȦįȓȦıȘȢ ȟİʌİȡȞȐ main distribution panel and additional T2 + T3 SPDs in the secondary
IJĮ 20m șİȦȡȫȞIJĮȢ ȩIJȚ ȠȚ țĮȜȦįȚĮțȑȢ ĮʌȠıIJȐıİȚȢ Įʌȩ IJȠȞ ȣʌȠʌȓȞĮțĮ distribution panel no additional protection is needed.
ȑȦȢ IJȚȢ ȘȜİțIJȡȠȞȚțȑȢ ıȣıțİȣȑȢ įİȞ ȟİʌİȡȞȠȪȞ IJĮ 10m. ȉȩIJİ İȖțĮșȚ- Case D: A structure that contains an electrical installation, which the
ıIJȫȞIJĮȢ ıIJȠ ȖİȞȚțȩ ʌȓȞĮțĮ ĮʌĮȖȦȖȩ ȉ1 + ȉ2 țĮȚ ıIJȠȞ ȣʌȠʌȓȞĮțĮ ȉ2 + total cabling length does exceed 20m assuming that the cabling
ȉ3 įİȞ ĮʌĮȚIJİȓIJĮȚ İʌȚʌȡȩıșİIJȘ ʌȡȠıIJĮıȓĮ. distances between the secondary panel and the electronic equipment in
13
A ÁÐÁÃÙÃÏÉ ÊÑÏÕÓÔÉÊÙÍ ÕÐÅÑÔÁÓÅÙÍ SURGE PROTECTIVE DEVICES
ȆİȡȓʌIJȦıȘ ¨: Ǿ țĮIJĮıțİȣȒ įȚĮșȑIJİȚ ȚĮ ȘȜİțIJȡȠȜȠȖȚțȒ İȖțĮIJȐıIJĮ- some cases does exceed 10m in length then by installing T1 + T2 SPDs
ıȘ Ș ȠʌȠȓĮ ıȣȞȠȜȚțȐ IJȠ ȑȖȚıIJȠ ȒțȠȢ IJȘȢ țĮȜȦįȓȦıȘȢ ȟİʌİȡȞȐ IJĮ in the main distribution panel, T2 + T3 SPDs in the secondary
20m șİȦȡȫȞIJĮȢ ȩIJȚ ȠȚ țĮȜȦįȚĮțȑȢ ĮʌȠıIJȐıİȚȢ Įʌȩ IJȠȞ ȣʌȠʌȓȞĮțĮ ȑȦȢ distribution panel and additional T3 SPDs in selective electronic
IJȚȢ ȘȜİțIJȡȠȞȚțȑȢ ıȣıțİȣȑȢ ıİ İȡȚțȑȢ ʌİȡȚʌIJȫıİȚȢ ȟİʌİȡȞȠȪȞ IJĮ 10m. equipment, for which the cable length up to the secondary panel does
ȉȩIJİ ıIJȠ ȖİȞȚțȩ ʌȓȞĮțĮ șĮ ʌȡȑʌİȚ ȞĮ İȖțĮIJĮıIJĮșİȓ ĮʌĮȖȦȖȩȢ ȉ1 +ȉ2, exceed the 10m.
ıIJȠȞ ȣʌȠʌȓȞĮțĮ ȉ2+ȉ3 țĮȚ İʌȚʌȡȩıșİIJȠȢ ĮʌĮȖȦȖȩȢ ȉ3 İʌȚȜİțIJȚțȐ ıİ Case E: Ideal protection scheme independent of the cabling distances,
țȐșİ ȘȜİțIJȡȠȞȚțȒ ıȣıțİȣȒ ʌȠȣ ȟİʌİȡȞȐ IJĮ 10m țĮȜȦįȚĮțȒȢ ĮʌȩıIJĮ- in the main distribution panel T1 + T2 SPDs, in the secondary
ıȘȢ Įʌȩ IJȠȞ ȣʌȠʌȓȞĮțĮ. distribution panel T2 SPDs and T3 SPDs next to each electronic
ȆİȡȓʌIJȦıȘ Ǽ: ǿįĮȞȚțȒ ʌȡȠıIJĮıȓĮ ĮȞİȟĮȡIJȒIJȠȣ ĮʌȠıIJȐıİȦȞ, ıIJȠ equipment.
ȖİȞȚțȩ ʌȓȞĮțĮ ĮʌĮȖȦȖȩȢ ȉ1+ ȉ2, ıIJȠȞ ȣʌȠʌȓȞĮțĮ ȉ2 țĮȚ ĮʌĮȖȦȖȩȢ ȉ3
ıİ țȐșİ ȘȜİțIJȡȠȞȚțȒ ıȣıțİȣȒ.
14
ÁÐÁÃÙÃÏÉ ÊÑÏÕÓÔÉÊÙÍ ÕÐÅÑÔÁÓÅÙÍ SURGE PROTECTIVE DEVICES A
ǼʌȚȜȠȖȒ IJȘȜİʌȚțȠȚȞȦȞȚĮțȫȞ ĮʌĮȖȦȖȫȞ țȡȠȣıIJȚțȫȞ Selection of data surge protective devices
ȣʌİȡIJȐıİȦȞ
The selection of data surge protective devices depends on the signal
Ǿ İʌȚȜȠȖȒ IJȦȞ IJȘȜİʌȚțȠȚȞȦȞȚĮțȫȞ ĮʌĮȖȦȖȫȞ İȟĮȡIJȐIJĮȚ Įʌȩ IJȠ İȓįȠȢ that the SPD is connected through. In brief the selection criteria are:
IJȠȣ ıȒĮIJȠȢ ʌȠȣ ıȣȞįȑİIJĮȚ o ĮʌĮȖȦȖȩȢ. ȆİȡȚȜȘʌIJȚțȐ IJĮ țȡȚIJȒȡȚĮ
İʌȚȜȠȖȒȢ İȓȞĮȚ: Telecom signals: Type of telecom line (PSTN, ISDN, DSL)
ȉȘȜİijȦȞȚțȐ ıȒĮIJĮ: ǼȓįȠȢ ȖȡĮȒȢ (PSTN, ISDN, DSL), ʌȜȒșȠȢ Analogue and digital signals: Frequency of the signal (Hz), voltage (V)
ȗİȣȖȫȞ. and current (A) of the signal
ǹȞĮȜȠȖȚțȐ țĮȚ ȥȘijȚĮțȐ ıȒĮIJĮ: ȈȣȤȞȩIJȘIJĮ ıȒĮIJȠȢ (Hz), IJȐıȘ (V) High frequency - RF signals: Frequency of the signal (Hz), power of
țĮȚ ȑȞIJĮıȘ (A) ıȒĮIJȠȢ. the signal (W), connector type (N, BNC etc), surge impedance of the
cable (50, 75 etc)
ȊȥȘȜȫȞ ȡĮįȚȠıȣȤȞȠIJȒIJȦȞ: ȈȣȤȞȩIJȘIJĮ ıȒĮIJȠȢ (Hz), ȚıȤȪȢ ıȒĮIJȠȢ
(W), IJİȡĮIJȚțȩȢ ĮțȡȠįȑțIJȘȢ țĮȜȦįȓȠȣ (N, BNC țIJȜ), țȣĮIJȚțȒ
ĮȞIJȓıIJĮıȘ țĮȜȦįȓȠȣ (50, 75 țIJȜ)
GND
L3 L2
E2 E3 E1
EQUIP
LINE
L1
DATA SURGE PROTECTOR
ĬȦȡȐțȚıȘ țĮȜȦįȓȠȣ
Cable Shield
L PE
SPD SPD
UC=275Vac UC=255Vac
In=5kA (8/20s) In=10kA (8/20s) ȆȡȠıIJĮıȓĮ ıȘȐIJȦȞ İIJĮijȠȡȐȢ įİįȠȑȞȦȞ
Imax=10kA (8/20s) Imax=20kA (8/20s)
Up = <1.5kV
Ta = <25ns
Up = <1.3kV
Ta = <100ns
Surge protection of information technology systems
T3 CE T3 CE
10T3 20GT3
N N
ǼȚțȩȞĮ 11: ǼʌȚȜȠȖȒ țĮȚ ıȘİȓĮ İȖțĮIJȐıIJĮıȘȢ IJȘȜİʌȚțȠȚȞȦȞȚĮțȫȞ ĮʌĮȖȦȖȫȞ țȡȠȣıIJȚțȫȞ ȣʌİȡIJȐıİȦȞ
Figure 11: Selection and installation of data surge protective devices
ǼʌȚȜȠȖȒ ĮȖȦȖȫȞ ıȪȞįİıȘȢ ȖȚĮ IJȠȣȢ ĮʌĮȖȦȖȠȪȢ țȡȠȣıIJȚțȫȞ ȣʌİȡIJȐıİȦȞ İȞİȡȖİȚĮțȠȪ įȚțIJȪȠȣ ȕȐıİȚ IJȠȣ Ǽȁȅȉ Ǽȃ 62305-4
Selection of connection conductor diameter of low voltage power surge protective devices according to EN 62305-4
ȉ1 ȉ2 ȉ3
ǼȜȐȤȚıIJȘ įȚĮIJȠȒ ĮȖȦȖȠȪ ıȪȞįİıȘȢ (ȤĮȜțȩȢ)
16 mm2 6 mm2 1,5 mm2
Minimum cross section of conductor (copper)
ȂȑȖȚıIJȘ įȚĮIJȠȒ ĮȖȦȖȠȪ ıȪȞįİıȘȢ1 (ȤĮȜțȩȢ)
35 mm2 35 mm2 35mm2
Maximum cross section of conductor1 (copper)
1 ǹijȠȡȐ ĮʌĮȖȦȖȠȪȢ ǼȁǼȂȀȅ ȖȚĮ İȖțĮIJȐıIJĮıȘ ıİ ȡȐȖĮ DIN - 3
1 For ELEMKO SPDs to be installed on DIN - 3 Rail
Ǿ İʌȚȜȠȖȒ IJȘȢ ĮıijȐȜİȚĮȢ șĮ ʌȡȑʌİȚ ȞĮ ȚțĮȞȠʌȠȚİȓ IJȚȢ ĮʌĮȚIJȒıİȚȢ IJȠȣ ĮʌĮȖȦȖȠȪ ĮȜȜȐ țĮȚ IJȠȣ țĮȜȦįȓȠȣ ıȪȞįİıȘȢ ȩʌȦȢ ȠȡȓȗİȚ IJȠ Ǽȁȅȉ HD 384
The selection of the fuse shall satisfy the requirements for the SPD as well as for the connection conductor according to installation rules of the country that the SPD will be installed
15
A ǺǹȈǿȀǼȈ ȅ¨ǾīǿǼȈ ǼīȀǹȉǹȈȉǹȈǾȈ ǹȆǹīīȃ BASIC INSTALLATION INSTRUCTION OF SPDS
ȂȒțȠȢ țĮȚ ȩįİȣıȘ ĮȖȦȖȠȪ ȖİȓȦıȘȢ ĮʌĮȖȦȖȫȞ Length and path of SPDs earthing conductor
Ǿ İȖțĮIJȐıIJĮıȘ IJȦȞ İȞİȡȖİȚĮțȫȞ ĮʌĮȖȦȖȫȞ ıIJȠ ȖİȞȚțȩ ʌȓȞĮțĮ ʌȡȑʌİȚ The installation of the power SPDs in the distribution panel shall be
ȞĮ ʌȡĮȖĮIJȠʌȠȚİȓIJĮȚ İ ȩıȠ IJȠ įȣȞĮIJȩȞ ȚțȡȩIJİȡĮ ȒțȘ ĮȖȦȖȫȞ, performed with short connection wires. According to EN 62305-4 the
ıȪijȦȞĮ İ IJȠ ʌȡȩIJȣʌȠ Ǽȁȅȉ Ǽȃ 62305- 4. ȉȠ ȚįĮȞȚțȩ ȒțȠȢ ĮȖȦ- appropriate connection wires shall not exceed the 0.5m in length.
ȖȫȞ ȖȚĮ IJȘ ıȪȞįİıȘ IJȦȞ ĮʌĮȖȦȖȫȞ įİȞ șĮ ʌȡȑʌİȚ ȞĮ ȟİʌİȡȞȐ IJȠ Țıȩ Large loops especially by the PE conductor shall be avoided.
ȑIJȡȠ. ǺȡȩȤȠȚ țĮȜȦįȓȦȞ İȖȐȜȠȣ ȒțȠȣȢ țĮȚ ȚįȚĮȓIJİȡĮ IJȠȣ ĮȖȦȖȠȪ Additionally the impression that the earthing conductor of the SPDs
ʌȡȠıIJĮıȓĮȢ ʌȡȑʌİȚ ȞĮ ĮʌȠijİȪȖȠȞIJĮȚ țĮșȫȢ ȣʌȐȡȤİȚ Ș ĮʌȩȜȣIJĮ ȜĮȞ- shall be completely independent from the PE conductor or the
șĮıȑȞȘ ĮȞIJȓȜȘȥȘ ȩIJȚ Ƞ ĮȖȦȖȩȢ ʌȡȠıIJĮıȓĮȢ ʌȠȣ ıȣȞįȑİIJĮȚ ıIJȠȣȢ equipotential bonding bar of the panel is completely wrong.
ĮʌĮȖȦȖȠȪȢ șĮ ʌȡȑʌİȚ ȞĮ ȠįİȪİȚ ĮȞİȟȐȡIJȘIJĮ ıIJȠȞ țȪȡȚȠ ȗȣȖȩ ȖİȓȦıȘȢ,
ʌȡȐȖĮ ʌȠȣ ıȪijȦȞĮ İ IJĮ ȚıȤȪȠȞIJĮ ʌȡȩIJȣʌĮ İȓȞĮȚ ȜȐșȠȢ.
ȆȡȠȢ ȀĮIJĮȞĮȜȫıİȚȢ
To Loads
RCD
8899kWhr
L L L PE
;
SPD SPD SPD SPD
U C = 275Vac U C = 275Vac UC = 275Vac U C = 255Vac
U p = <1,9kV U p = <1,9kV Up = <1,9kV U p = <4kV
I imp = 25kA (10/350s) Iimp = 25kA (10/350 s) Iimp = 25kA (10/350 s) I imp = 100kA (10/350s)
I max = 200kA (8/20s) Imax = 200kA (8/20s) Imax = 200kA (8/20s) Imax = 200kA (8/20 s)
Ta = <25ns Ta = <25ns Ta = <25ns Ta = <100ns
68 50 200 T1 + T2 CE 68 50 200 T1 + T2 CE 68 50 200 T1 + T2 CE 68 51 200 T1 + T2 CE
N N N N
ǼȚțȩȞĮ 12: ǼȖțĮIJȐıIJĮıȘ ĮʌĮȖȦȖȫȞ țȡȠȣıIJȚțȫȞ ȣʌİȡIJȐıİȦȞ ıIJȠ ȖİȞȚțȩ ʌȓȞĮțĮ ȤȡȘıȚȠʌȠȚȫȞIJĮȢ IJȠ ȕȑȜIJȚıIJȠ ȒțȠȢ ĮȖȦȖȫȞ ıȪȞįİıȘȢ țĮȚ țȠȚȞȩ ĮȖȦȖȩ
ʌȡȠıIJĮıȓĮȢ İIJĮȟȪ ĮʌĮȖȦȖȫȞ țĮȚ IJȠʌȚțȠȪ ȗȣȖȠȪ ȖİȓȦıȘȢ ȖİȞȚțȠȪ ʌȓȞĮțĮ ȈȈȉȅ
Figure 12: Installation of power SPDs in the distribution panel by using the minimum required connection wire and having common bonding bar between the PE
conductor and the earthing conductor of the SPDs CORRECT
ȆȡȠȢ ȀĮIJĮȞĮȜȫıİȚȢ
To Loads
RCD
8899kWhr
L L L PE
:
SPD SPD SPD SPD
U C = 275Vac U C = 275Vac UC = 275Vac U C = 255Vac
U p = <1,9kV U p = <1,9kV Up = <1,9kV U p = <4kV
I imp = 25kA (10/350s) Iimp = 25kA (10/350 s) Iimp = 25kA (10/350 s) I imp = 100kA (10/350s)
I max = 200kA (8/20s) Imax = 200kA (8/20s) Imax = 200kA (8/20s) Imax = 200kA (8/20 s)
Ta = <25ns Ta = <25ns Ta = <25ns Ta = <100ns
68 50 200 T1 + T2 CE 68 50 200 T1 + T2 CE 68 50 200 T1 + T2 CE 68 51 200 T1 + T2 CE
N N N N
ǼȚțȩȞĮ 13: ǼȖțĮIJȐıIJĮıȘ ĮʌĮȖȦȖȫȞ țȡȠȣıIJȚțȫȞ ȣʌİȡIJȐıİȦȞ ıIJȠ ȖİȞȚțȩ ʌȓȞĮțĮ ȤȡȘıȚȠʌȠȚȫȞIJĮȢ ĮȞİȟȐȡIJȘIJȠ ĮȖȦȖȩ ʌȡȠıIJĮıȓĮȢ ȖȚĮ IJȠȣȢ ĮʌĮȖȦȖȠȪȢ ȁǹĬȅȈ
Figure 13: Installation of power SPDs in the distribution panel by using long connection wire and independent from the PE conductor WRONG
16
ǺǹȈǿȀǼȈ ȅ¨ǾīǿǼȈ ǼīȀǹȉǹȈȉǹȈǾȈ ǹȆǹīīȃ BASIC INSTALLATION INSTRUCTION OF SPDS A
ȀȠȚȞȩ ıȪıIJȘĮ ȖİȓȦıȘȢ Common earthing system
ȈȪijȦȞĮ İ IJĮ ȞȑĮ İșȞȚțȐ țĮȚ İȣȡȦʌĮȧțȐ ʌȡȩIJȣʌĮ Ǽȁȅȉ Ǽȃ 62305- According to the EN 62305-3 from the lightning and surge protection
3 ȖȚĮ ĮʌȠIJİȜİıĮIJȚțȒ ʌȡȠıIJĮıȓĮ Įʌȩ țȡȠȣıIJȚțȑȢ ȣʌİȡIJȐıİȚȢ, șĮ point of view a common and single integrated earthing system is
ʌȡȑʌİȚ ȚĮ țĮIJĮȞȐȜȦıȘ ȞĮ ȑȤİȚ ȑȞĮ İȞȚĮȓȠ / țȠȚȞȩ ıȪıIJȘĮ ȖİȓȦıȘȢ. preferable and is suitable for all purposes (i.e. safety earthing,
ǹȣIJȩ ıȘĮȓȞİȚ ȩIJȚ İȐȞ ȚĮ țĮIJĮȞȐȜȦıȘ įȚĮșȑIJİȚ ȑȞĮ ıȪıIJȘĮ ȖİȓȦıȘȢ lightning protection earthing, telecommunication earthing).
Įʌȩ IJȘȞ ȘȜİțIJȡȚțȒ ʌĮȡȠȤȒ, ȑȞĮ Įʌȩ IJȘȞ IJȘȜİijȦȞȚțȒ ʌĮȡȠȤȒ țĮȚ Įʌȩ
IJȘȞ ĮȞIJȚțİȡĮȣȞȚțȒ ʌȡȠıIJĮıȓĮ, șĮ ʌȡȑʌİȚ ȞĮ İȓȞĮȚ ȩȜĮ ȚıȠįȣȞĮȚțȐ
ıȣȞįİįİȑȞĮ
???
8899kWhr
;
SURGE PROTECTION
īİȓȦıȘ ¨ǼǾ
īİȓȦıȘ ǹȞIJȚțİȡĮȣȞȚțȒȢ
īİȓȦıȘ ȅȉǼ
OTE
SURGE PROTECTION
Arrester is operational when green
light is on
???
8899kWhr
:
SURGE PROTECTION
īİȓȦıȘ ¨ǼǾ
īİȓȦıȘ ǹȞIJȚțİȡĮȣȞȚțȒȢ
īİȓȦıȘ ȅȉǼ
OTE
SURGE PROTECTION
Arrester is operational when green
light is on
17
A ǺǹȈǿȀǼȈ ȅ¨ǾīǿǼȈ ǼīȀǹȉǹȈȉǹȈǾȈ ǹȆǹīīȃ BASIC INSTALLATION INSTRUCTION OF SPDS
ǹʌȩıIJĮıȘ İIJĮȟȪ ĮʌĮȖȦȖȠȪ țĮȚ ȣʌȩ ʌȡȠıIJĮıȓĮ ıȣıțİȣȒȢ Distance between SPD and under protection equipment
ȈȪijȦȞĮ İ IJĮ ȞȑĮ İșȞȚțȐ țĮȚ İȣȡȦʌĮȧțȐ ʌȡȩIJȣʌĮ Ǽȁȅȉ Ǽȃ 62305- According to EN 62305-4 the efficiency of a surge protective device is
4 ȑȞĮȢ ĮʌĮȖȦȖȩȢ ȖȚĮ ȞĮ ȜİȚIJȠȣȡȖȒıİȚ ĮʌȠIJİȜİıĮIJȚțȐ șĮ ʌȡȑʌİȚ ȞĮ also relevant to the distance between the SPD and the under protection
İȓȞĮȚ țȠȞIJȐ ıIJȘȞ ȣʌȩ ʌȡȠıIJĮıȓĮ ıȣıțİȣȒ. Ȣ ȑȖȚıIJȘ ĮʌȩıIJĮıȘ IJĮ equipment. As a maximum distance the standard defines the 10m. For
ʌȡȩIJȣʌĮ ȠȡȓȗȠȣȞ IJĮ 10 ȑIJȡĮ. ȉȠ ȓįȚȠ ȚıȤȪİȚ țĮȚ ȖȚĮ IJȠȞ ĮȖȦȖȩ a distance longer than 10m then an additional SPD shall be installed.
ȖİȓȦıȘȢ IJȠȣ ĮʌĮȖȦȖȠȪ, Ƞ ȠʌȠȓȠȢ șĮ ʌȡȑʌİȚ ȞĮ țĮIJĮȜȒȖİȚ ıIJȘȞ ȣʌȩ The ideal distance is up to 0.5m.
ʌȡȠıIJĮıȓĮ ıȣıțİȣȒ (țȠȚȞȩȢ İ IJȠȞ ĮȖȦȖȩ ʌȡȠıIJĮıȓĮȢ ȇǼ) İ ȩıȠ IJȠ
įȣȞĮIJȩȞ ȚțȡȩIJİȡȠ ȒțȠȢ țĮȜȦįȓȠȣ (0,5m ȚįĮȞȚțȩ ȒțȠȢ)
0.5m
SURGE PROTECTION
;
light is on
ǼȚțȩȞĮ 16: ǹʌȩıIJĮıȘ İIJĮȟȪ ĮʌĮȖȦȖȠȪ țĮȚ ȣʌȩ ʌȡȠıIJĮıȓĮ ıȣıțİȣȒȢ <10m (0,5m ȚįĮȞȚțȩ) ȈȈȉȅ
Figure 16: Distance between SPD and under protection equipment < 10m (0,5m ideal) CORRECT
>10m
SURGE PROTECTION
ǼȚțȩȞĮ 17: ǹʌȩıIJĮıȘ İIJĮȟȪ ĮʌĮȖȦȖȠȪ țĮȚ ȣʌȩ ʌȡȠıIJĮıȓĮ ıȣıțİȣȒȢ > 10m ȁǹĬȅȈ
Figure 17: Distance between SPD and under protection equipment > 10m WRONG
18
ǺǹȈǿȀǼȈ ȅ¨ǾīǿǼȈ ǼīȀǹȉǹȈȉǹȈǾȈ ǹȆǹīīȃ BASIC INSTALLATION INSTRUCTION OF SPDS A
ǼʌȚȜȠȖȒ ĮıijĮȜȚıIJȚțȠȪ ȑıȠȣ ȖȚĮ IJȠȣȢ ĮʌĮȖȦȖȠȪȢ Selection of overcurrent protection of SPDs
țȡȠȣıIJȚțȫȞ ȣʌİȡIJȐıİȦȞ
The use of an overcurrent protection device for the protection of the
Ǿ ȤȡȒıȘ ĮıijĮȜİȚȫȞ ȖȚĮ IJȘȞ ĮȣIJȠʌȡȠıIJĮıȓĮ IJȠȣ ĮʌĮȖȦȖȠȪ ĮȜȜȐ țĮȚ end of life of the SPD as well as for the connection wire is a
ȖȚĮ IJȠȣ țĮȜȦįȓȠȣ ıȪȞįİıȘȢ İȓȞĮȚ ȚĮ ȕĮıȚțȒ ĮʌĮȓIJȘıȘ IJȠȣ ʌȡȩIJȣʌȠȣ requirement even by the installation rules. However the overcurrent
Ǽȁȅȉ HD 384 (țȐșİ ĮȞĮȤȫȡȘıȘ ʌȡȑʌİȚ ȞĮ İȓȞĮȚ ĮıijĮȜȚıȑȞȘ). protection device may limit the efficiency of the SPD since it should
ǹȣIJȩ ȩȦȢ ʌȠȡİȓ ȞĮ İȚȫıİȚ IJȘȞ ĮʌȩįȠıȘ IJȠȣ ĮʌĮȖȦȖȠȪ țĮșȫȢ Ș behave in an appropriate manner when discharging surge currents.
ĮıijĮȜȚıIJȚțȒ įȚȐIJĮȟȘ ʌȠȣ șĮ İʌȚȜİȖİȓ șĮ ʌȡȑʌİȚ ȞĮ ȑȤİȚ țĮȜȒ The best overcurrent device with respect to surge current discharge
ıȣʌİȡȚijȠȡȐ ıIJȠ țȡȠȣıIJȚțȩ ȡİȪĮ ʌȠȣ șĮ IJİșİȓ ȞĮ İțijȠȡIJȓıİȚ. Ǿ capability is the cartridge type fuse since it is constructed by a single
țĮȜȪIJİȡȘ ĮıijĮȜȚıIJȚțȒ įȚȐIJĮȟȘ ȖȚĮ ĮȞIJȠȤȒ ıİ țȡȠȣıIJȚțȐ ȡİȪĮIJĮ wide wire element of rather short length. In contrast the MCBs and the
İȓȞĮȚ Ș IJȘțIJȒ ĮıijȐȜİȚĮ țĮșȫȢ įȚĮșȑIJİȚ Țțȡȩ ȒțȠȢ ıȪȡĮIJȠȢ RCDs, contain internal coils with rather long and thin wires and
İȖȐȜȘȢ įȚĮIJȠȒȢ ıİ ĮȞIJȓșİıȘ İ IJȠȣȢ ȚțȡȠĮȣIJȩĮIJȠȣȢ țĮȚ IJĮ ȡİȜȑ therefore the surge discharge current capability is limited. Especially
ʌȠȣ įȚĮșȑIJȠȣȞ İıȦIJİȡȚțȐ ʌȘȞȓĮ IJĮ ȠʌȠȓĮ ȑȤȠȣȞ İȖȐȜȠ ȒțȠȢ the RCD, which is used for protection against electric shock the
ıȪȡĮIJȠȢ, ȚțȡȒȢ įȚĮIJȠȒȢ țĮȚ įİȞ ʌȠȡȠȪȞ ȞĮ ĮȞIJȑȟȠȣȞ țȡȠȣıIJȚțȐ internal circuitry is of vital importance and it should not be damaged.
ȡİȪĮIJĮ İȖȐȜȘȢ İȞIJȐıİȦȢ. ǼȚįȚțȐ IJȠ ȡİȜȑ IJȠȣ ȠʌȠȓȠȣ Ș ȤȡȒıȘ IJȠȣ Therefore in countries where the use of SPDs (at least for the primary
İȓȞĮȚ ȚįȚĮȓIJİȡĮ ıȘĮȞIJȚțȒ ȖȚĮ IJȘȞ ʌȡȠıIJĮıȓĮ IJȘȢ ĮȞșȡȫʌȚȞȘȢ ȗȦȒȢ ıİ protection in the main distribution panel) before the RCD is allowed by
țĮȓĮ ʌİȡȓʌIJȦıȘ įİȞ șĮ ʌȡȑʌİȚ ȞĮ İȓȞĮȚ İȖțĮIJİıIJȘȑȞȠ ʌȡȚȞ IJȠȣȢ the installation rules may be a good practice. Of course the use of
ĮʌĮȖȦȖȠȪȢ (IJȠȣȜȐȤȚıIJȠȞ ıIJȠ ȖİȞȚțȩ ʌȓȞĮțĮ) țĮșȫȢ IJȠ țȡȠȣıIJȚțȩ MCBs or RCDs as overcurrent protection can not be claimed to be
ȡİȪĮ ʌȠȡİȓ ȞĮ ĮȜȜȠȚȫıİȚ IJĮ ȤĮȡĮțIJȘȡȚıIJȚțȐ IJȠȣ țĮȚ İʌȠȑȞȦȢ IJȘȞ wrong however, where this is allowed by the national electrical
ĮʌȠIJİȜİıĮIJȚțȩIJȘIJȐ IJȠȣ. Ǿ ȤȡȒıȘ ȚțȡȠĮȣIJȩĮIJȦȞ țĮȚ ȡİȜȑ ʌȡȑʌİȚ installation rules, SPDs are advised to be installed before any MCB or
ȞĮ ȖȓȞİIJĮȚ İIJȐ IJȠȣȢ ĮʌĮȖȦȖȠȪȢ țȡȠȣıIJȚțȫȞ ȣʌİȡIJȐıİȦȞ țĮȚ ĮȣIJȩ RCD.
țȣȡȓȦȢ ȖȚĮ IJȘȞ ʌȡȦIJİȪȠȣıĮ ʌȡȠıIJĮıȓĮ ıIJȠ ȖİȞȚțȩ ʌȓȞĮțĮ. ȉĮ
ȤĮȡĮțIJȘȡȚıIJȚțȐ IJȘȢ ĮıijȐȜİȚĮȢ ʌȠȣ șĮ ʌȡȑʌİȚ ȞĮ İʌȚȜİȖİȓ İȟĮȡIJȐIJĮȚ
Įʌȩ IJĮ IJİȤȞȚțȐ ȤĮȡĮțIJȘȡȚıIJȚțȐ IJȠȣ ĮʌĮȖȦȖȠȪ ĮȜȜȐ țĮȚ IJȠȣ țĮȜȦįȓȠȣ
ıȪȞįİıȘȢ.
ȆȡȠȢ ȀĮIJĮȞĮȜȫıİȚȢ
To Loads
RCD
L L L PE
;
SPD SPD SPD SPD
U C = 275Vac U C = 275Vac UC = 275Vac U C = 255Vac
U p = <1,9kV U p = <1,9kV Up = <1,9kV U p = <4kV
I imp = 25kA (10/350s) Iimp = 25kA (10/350s) Iimp = 25kA (10/350 s) I imp = 100kA (10/350s)
I max = 200kA (8/20s) Imax = 200kA (8/20s) Imax = 200kA (8/20s) Imax = 200kA (8/20s)
Ta = <25ns Ta = <25ns Ta = <25ns Ta = <100ns
68 50 200 T1 + T2 CE 68 50 200 T1 + T2 CE 68 50 200 T1 + T2 CE 68 51 200 T1 + T2 CE
N N N N
ǼȚțȩȞĮ 18: ȋȡȒıȘ IJȘțIJȫȞ ĮıijĮȜİȚȫȞ ʌȡȚȞ IJȠȣȢ ĮʌĮȖȦȖȠȪȢ ıIJȠ ȖİȞȚțȩ ʌȓȞĮțĮ ȈȈȉȅ
Figure 18: Use of cartridge type fuses as an overcurrent protection of the SPDs in the main panel CORRECT
RCD
L L L PE L L L PE
:
U p = <1,9kV U p = <1,9kV Up = <1,9kV U p = <4kV U p = <1,9kV U p = <1,9kV Up = <1,9kV U p = <4kV
I imp = 25kA (10/350s) Iimp = 25kA (10/350s) Iimp = 25kA (10/350 s) I imp = 100kA (10/350s) I imp = 25kA (10/350s) Iimp = 25kA (10/350s) Iimp = 25kA (10/350 s) I imp = 100kA (10/350s)
I max = 200kA (8/20s) Imax = 200kA (8/20s) Imax = 200kA (8/20s) Imax = 200kA (8/20s) I max = 200kA (8/20s) Imax = 200kA (8/20s) Imax = 200kA (8/20s) Imax = 200kA (8/20s)
Ta = <25ns
68 50 200 T1 + T2 CE
Ta = <25ns
68 50 200 T1 + T2 CE
Ta = <25ns
68 50 200 T1 + T2 CE
Ta = <100ns
68 51 200 T1 + T2 CE
RCD Ta = <25ns
68 50 200 T1 + T2 CE
Ta = <25ns
68 50 200 T1 + T2 CE
Ta = <25ns
68 50 200 T1 + T2 CE
Ta = <100ns
68 51 200 T1 + T2 CE
N N N N N N N N
ǼȚțȩȞĮ 19: ȋȡȒıȘ ȚțȡȠĮȣIJȩĮIJȦȞ Ȓ ȡİȜȑ ʌȡȚȞ IJȠȣȢ ĮʌĮȖȦȖȠȪȢ ıIJȠ ȖİȞȚțȩ ʌȓȞĮțĮ ¨Ǽȃ ȈȊȃǿȈȉǹȉǹǿ
Figure 19: Use of MCB or RCD as an overcurrent protection of the SPDs in the main panel NOT ADVISED
19
A ǺǹȈǿȀǼȈ ȅ¨ǾīǿǼȈ ǼīȀǹȉǹȈȉǹȈǾȈ ǹȆǹīīȃ BASIC INSTALLATION INSTRUCTION OF SPDS
ȂȒțȠȢ ĮȖȦȖȠȪ ȖİȓȦıȘȢ DATA ĮʌĮȖȦȖȫȞ Length of earthing conductor of DATA SPDs
ȅȚ ĮʌĮȖȦȖȠȓ ʌȠȣ ȤȡȘıȚȠʌȠȚȠȪȞIJĮȚ ȖȚĮ IJȘȞ ʌȡȠıIJĮıȓĮ ıȣıțİȣȫȞ ʌȠȣ The SPDs used for DATA signal equipment shall be connected also to
ȑȤȠȣȞ İȚıİȡȤȩİȞĮ șȦȡĮțȚıȑȞĮ țĮȜȫįȚĮ șĮ ʌȡȑʌİȚ ȞĮ the shield of the DATA cable. Also the DATA SPDs shall be installed at
IJȠʌȠșİIJȠȪȞIJĮȚ ıİ ȚțȡȒ ĮʌȩıIJĮıȘ Įʌȩ IJȘȞ ȣʌȩ ʌȡȠıIJĮıȓĮ ıȣıțİȣȒ a short distance - preferable less than 0.5m with the under protection
(ʌ.Ȥ. PLC) țĮȚ Ș șȦȡȐțȚıȘ IJȠȣ țĮȜȦįȓȠȣ İIJĮijȠȡȐȢ įİįȠȑȞȦȞ șĮ equipment. Also the earthing wire of the SPD shall be short avoiding
ʌȡȑʌİȚ ȞĮ ıȣȞįİșİȓ ıIJȠȞ ĮʌĮȖȦȖȩ. ȉȠ ȚįĮȞȚțȩ ȒțȠȢ țĮȜȦįȓȠȣ unnecessary loops.
İIJĮȟȪ ĮʌĮȖȦȖȠȪ țĮȚ ıȣıțİȣȒȢ įİȞ șĮ ʌȡȑʌİȚ ȞĮ ȣʌİȡȕĮȓȞİȚ IJȠ 0,5
ȑIJȡȠ. ȉȠ ȓįȚȠ ȚıȤȪİȚ țĮȚ ȖȚĮ IJȠȞ ĮȖȦȖȩ IJȘȢ ȖİȓȦıȘȢ IJȠȣ ĮʌĮȖȦȖȠȪ.
GND
L3 L2
E2 E3 E1
EQUIP
LINE
L1
DATA SURGE PROTECTOR
;
Appropriate wire length (<0,5m)
GND
L3 L2
E2 E3 E1
EQUIP
LINE
L1
:
Remaining wire length forming a coil
20
ǼĭǹȇȂȅīǾ ǹȆǹīīȃ ȀȇȅȊȈȉǿȀȃ
ȊȆǼȇȉǹȈǼȃ ȈǼ ȅǿȀǿǹ
APPLICATION OF SPDs IN A
RESIDENTIAL BUILDING
A
2
3
4
1
ȆȡȠıIJĮıȓĮ ȈȘȐIJȦȞ TV
TV Line Protection 3
ȆȡȠıIJĮıȓĮ ȈȘȐIJȦȞ TV
TV Line Protection
64
21
A ǼĭǹȇȂȅīǾ ǹȆǹīīȃ ȀȇȅȊȈȉǿȀȃ
ȊȆǼȇȉǹȈǼȃ ȈǼ ǺǿȅȂǾȋǹȃǿǹ
APPLICATION OF SPDs IN AN
INDUSTRIAL SITE
ȆȡȦIJİȪȠȣıĮ ȆȡȠıIJĮıȓĮ
ǹȞșȡȫʌȦȞ & ǾȂ ǼȟȠʌȜȚıȠȪ/
LV Power Line Primary Protection
3
ȉȠʌȚțȒ ȆȡȠıIJĮıȓĮ ȂȘȤĮȞȫȞ
Fine Protection of Equipment
¨İȣIJİȡİȪȠȣıĮ ȆȡȠıIJĮıȓĮ
2 ǾȂ ǼȟȠʌȜȚıȠȪ/
LV Power Line Secondary Protection
4
ȆȡȠıIJĮıȓĮ Inverter PV
Protection of PV inverter
ȆȡȠıIJĮıȓĮ Ȋ/Ȉ, ȂȑıȘȢ ȉȐıȘȢ
Medium Voltage Protection
ȆȡȠıIJĮıȓĮ DC ȉȡȠijȠįȠIJȚțȫȞ
DC Power supply protection
ȆȡȠıIJĮıȓĮ ıȘȐIJȦȞ PLC
PLC Signal Line Protection
3
1
22
ǼĭǹȇȂȅīǾ ǹȆǹīīȃ ȀȇȅȊȈȉǿȀȃ
ȊȆǼȇȉǹȈǼȃ ȈǼ ȀȉǾȇǿȅ īȇǹĭǼǿȃ
APPLICATION OF SPDs IN AN
OFFICE BUILDING
A
¨İȣIJİȡİȪȠȣıĮ ȆȡȠıIJĮıȓĮ ǾȜİțIJȡȚțȫȞ ȈȣıțİȣȫȞ
Power Line Secondary Protection
4
ȆȡȦIJİȪȠȣıĮ ȆȡȠıIJĮıȓĮ ǹȞșȡȫʌȦȞ
& ǾȂ ǼȟȠʌȜȚıȠȪ
LV Power Line Primary Protection
1
3
3
1
23